JPJesus Djalma Pécora

Jesus Djalma Pécora

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jesus Djalma Pécora has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Alexandre Capelli

    University of São Paulo Faculty of Dentistry of Ribeirão Preto Department of Restorative Dentistry

    6 shared publications
  • Juliana Machado Barroso

    University of São Paulo Faculty of Dentistry of Ribeirão Preto Department of Restorative Dentistry

    4 shared publications
  • Carlos Estrela

    Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil

    3 shared publications
  • D. M. Z. Guerisoli

    Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil

    3 shared publications
  • Danilo M. Zanello Guerisoli

    University of São Paulo, Brazil

    3 shared publications
  • Júlio César Emboava Spanó

    University of São Paulo Faculty of Dentistry of Ribeirão Preto Department of Restorative Dentistry

    2 shared publications

Latest Publications

  • Open Access

    Detection of Organochlorine Compounds Formed During the Contact of Sodium Hypochlorite with Dentin and Dental Pulp

    by Tiago Gilioli Varise, Carlos Estrela, Débora Fernandes Costa Guedes, Manoel Damião Sousa-Neto, Jesus Djalma Pécora

    This study used gas chromatography-mass spectrometry (GC-MS) to detect the products formed during the contact of sodium hypochlorite (NaOCl) with bovine pulp and dentin. For analysis of the products formed in the volatile phase, 11 mg of bovine pulp tissue were placed in contact with 0.5%, 2.5% and 5.25% NaOCl until complete tissue dissolution occurred. The solid phase microextraction (SPME) fiber was exposed inside the container through the cover membrane and immediately injected into the GC-MS system. 30 mg of the of dentin were kept in contact with NaOCl, and then the SPME fiber was exposed inside the container through the cover membrane for adsorption of the products and injected into the GC-MS system. The same protocol was used for the aqueous phase. For analysis of the volatile compounds, the final solution was extracted using pure ethyl ether. The suspended particulate phase of the mixture was aspirated, and ether was separated from the aqueous phase of the solution. The ether containing the products that resulted from the chemical interaction of dentin and pulp with the NaOCl was filtered and then injected into the GC-MS system for analysis of the aqueous phase. The aqueous and volatile phases of both dentin and pulp showed the formation of chloroform, hexachloroethane, dichloromethylbenzene and benzaldehyde. In conclusion, organochlorine compounds are generated during the contact of dentin and pulp with NaOCl at concentrations of 0.5%, 2.5% and 5.25%.


  • Open Access

    Detection of Root Canal Isthmuses in Molars by Map-Reading Dynamic using CBCT images

    by Jesus Djalma Pecora, Carlos Estrela, Mike Reis Bueno, Olavo Cesar Porto, Ana Helena Goncalves Alencar, Manoel Damiao Sousa-Neto, Cyntia Rodrigues de Araujo Estrela

    The aim of this study was to detect root isthmuses in maxillary and mandibular molars and evaluate their frequencies using map-reading dynamics in CBCT images. Two hundred extracted human maxillary and mandibular molars were used in ex vivo assay. A consecutive sample of two hundred maxillary and mandibular molars (first and second) was selected from CBCT exams. The isthmuses were detected from the pulp orifice to the apex and were recorded according to their beginning and their end, into categories: 1. begin and end in cervical third; 2. beginning in cervical third and end in middle third; 3. beginning in cervical third and end in apical third; 4. beginning and end in middle third; 5. begin in middle third and end in apical third; 6. beginning and end in apical third; 7. no isthmus. The scans were obtained in different planes with map-reading in axial slices of 0.5 mm/0.5 mm involved the coronal to apical direction. The frequencies of isthmus were analyzed according to the level of root and evaluated by Chi-square test. The level of significance was set at α=0.05. The presence of isthmus detected in maxillary molars was 86% in ex vivo assay and 62% in vivo assay, whereas in mandibular molars was observed 70% in ex vivo assay and 72% in vivo assay. The frequency of isthmus was high in both study models. The map-reading dynamics in CBCT images was found to be precise to detect the localization of isthmus.


  • Water flow on erbium:yttrium–aluminum–garnet laser irradiation: effects on dental tissues

    by Vivian Colucci, Flávia Lucisano Botelho Do Amaral, Jesus Djalma Pécora, Regina Guenka Palma-Dibb, Silmara Aparecida Milori Corona

    Since lasers were introduced in dentistry, there has been considerable advancement in technology. Several wavelengths have been investigated as substitutes for high-speed air turbine. Owing to its high absorbability in water and hydroxyapatite, the erbium:yttrium–aluminum–garnet (Er:YAG) laser has been of great interest among dental practitioners and scientists. In spite of its great potential for hard tissue ablation, Er:YAG laser effectiveness and safety is directly related to an adequate setting of the working patterns. It is assumed that the ablation rate is influenced by certain conditions, such as water content of the target tissue, and laser parameters. It has been shown that Er:YAG irradiation with water coolant attenuates temperature rise and, hence, minimizes the risk of thermally induced pulp injury. It also increases ablation efficiency and enhances adhesion to the lased dental tissue. The aim of this review was to obtain insights into the ablation process and to discuss the effects of water flow on dental tissue ablation using Er:YAG laser.


  • Open Access

    Influence of cervical preflaring on apical file size determination in maxillary lateral incisors

    by Guilherme Siqueira Ibelli, Juliana Machado Barroso, Alexandre Capelli, Júlio César Emboava Spanó, Jesus Djalma Pécora

    The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in maxillary lateral incisors. Forty human lateral incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL (WL) was set 1 mm short of the apical foramen. Four groups (n=10) were formed at random, according to the type of cervical preflaring performed. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle root canal thirds. Group 2 had the cervical and middle root canal thirds enlarged with nickel-titanium Orifice Opener instruments. Group 3 had the cervical and middle root canal thirds enlarged with Gates-Glidden drills. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle root canal thirds of group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were recorded (in mm) for each sample. Significant differences were found between the groups regarding the anatomical diameter at the WL and the first file to bind the canal (p = 0.01). The major discrepancy was found when no preflaring was performed (0.1882 mm average). Canals preflared with Orifice Opener instruments (0.0485 mm average) and Gates-Glidden drills (0.1074 mm average) also showed great discrepancy. The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.0119 mm average). Instrument binding technique for determining anatomical diameter at WL was not accurate. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role on determination of the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.


  • Open Access

    Evaluation of apical microleakage of teeth sealed with four different root canal sealers

    by Fábio Dultra, Juliana Machado Barroso, Laise Daniela Carrasco, Alexandre Capelli, Danilo M. Zanello Guerisoli, Jesus Djalma Pécora

    OBJECTIVES: to compare the apical sealing ability of four root canal sealers. MATERIAL AND METHODS: forty extracted human maxillary canines were instrumented 1 mm short of the anatomical apex and randomly assigned to four groups (n=10), according to the root canal sealer used for obturation: Endofill, AH Plus, EndoREZ and Epiphany. Root canals were obturated with gutta-percha points, except for the Epiphany group, in which resin points (Resilon) were used. The teeth were immersed in India ink for seven days and clarified using methyl salicylate. The extent of apical dye penetration was measured with a measuroscope in all aspects of the canal. RESULTS: AH Plus (0.02 mm ± 0.07), Epiphany (0.00 mm ± 0.00) and EndoREZ (0.32 mm ± 0.62) did not differ statistically to each other (p>0.01). EndoFill presented the highest dye penetration mean (0.83 mm ± 0.73) and was statistically different from the other sealers (p<0.01). CONCLUSION: the resin-based root canal sealers presented lesser apical microleakage than the zinc oxide and eugenol based sealer. No statistical differences were observed among resin based sealers.


  • LLLT in treating dentinary hypersensitivity: new concepts

    by Jr. Aldo Brugnera, Fatima Zanin, Thereza Christinna Ladalardo, Antonio Pinheiro, Jesus Djalma Pecora

    Dental hypersensitivity has been studied for several years and it is reported as a strikingly painful condition originating from the exposition of dentinal tubuli . The exposed area is subjected to several kinds of stimuli, resulting in a rapid sharp acute pain. LLLT has been shown to have antiinflammatory, analgesic and cellular effects in both hyperemia and inflammation of the dental pulp. Our previous histological study showed that irradiated animals presented an increased production of dentine and shutting of dentinal tubuli. On the other hand, non-irradiated subjects still showed signals of intense inflammatory reaction and even necrosis at the same experimental times. Irradiated teeth did not show cell degeneration. The LLLT was shown to be efficient in the stimulation of odontoblast cells, producing reparative dentin and closing dentin tubuli. Our clinical studies with 660nm, 790nm and 830nm diode laser, and the total dose per tooth of 4J/cm was shown effective in treating dentinal hypersensitivity as it quickly reduces pain and maintains a prolonged painless status in 91.27 % to 97% of the cases. In a recent study our team observed that significant levels of dentinal desensitization were only found in patients belonging to the 25-35 age group. In conclusion, the results demonstrated indeed that LLLT, when based on the use of correct irradiations parameters is effective in treating hypersensitivity, but the age of patients is one of the factors that may alter the success of treatment due to dentinal sclerosis, which makes the penetration of light more difficult.

  • Open Access

    Shock of paradigms on the instrumentation of curved root canals

    by Jesus Djalma Pécora, Alexandre Capelli

    This paper makes a practical analysis about the paradigm on the instrumentation of curved root canals. In Endodontics, a paradigm has been created. Theories and techniques for instrumentation of curved root canals state that the use of a #25 file in the apical portion fulfills all the requirements for cleaning and shaping of the root canal system. Every scientific theory or paradigm should be continuously opened to modifications or refutation. The existence of extremely flexible instruments fabricated from metal alloys, methods for accurate determination of the real anatomic diameter and achievement of optimal shaping and cleaning of the apical portion created new theories and a new paradigm on the instrumentation of curved root canals. Therefore, this new insight will gradually modify the mentality of researchers and clinicians, but will still be open to further investigations and theories.


  • Influence of cervical preflaring on apical file size determination

    by J. D. Pecora, A. Capelli, D. M. Z. Guerisoli, J. C. E. Spanó, C. Estrela

    Aim To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Methodology Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Results Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P < 0.01, 95% confidence interval). The major discrepancy was found when no preflaring was performed (0.151 mm average). The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.016 mm average). Gates-Glidden drills and Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). Conclusions The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.


  • Open Access

    Influence of gutta-percha points on the filling of simulated lateral canals

    by Juliana Machado Barroso, Laise Daniela Carrasco, Alexandre Capelli, Danilo Mathias Zanello Guerisoli, Paulo César Saquy, Jesus Djalma Pécora

    The aim of this study was to investigate, in vitro, the percentage of filling of simulated lateral canals in teeth obturated with TP medium and standardized gutta-percha points. Twenty human mandibular canines were prepared with LA Axxess (SybronEndo) and K³ Endo rotary system (SybronEndo) up to a #50 file, according to the Free Tip Preparation Technique. During instrumentation, the root canals were alternately irrigated with 1% sodium hypochlorite and 17% EDTA. Six artificial lateral canals were prepared at the apical third of each tooth. Then, the teeth were assigned to two groups (n=10): Group 1 - filled with TP medium master gutta-percha points (Dentsply, Mailleffer); Group 2 - filled with standardized master gutta-percha points (Dentsply, Mailleffer). Root canal filling was complemented with AH Plus sealer (Dentsply, Mailleffer) and accessory gutta-percha points (Dentsply, Mailleffer), according to the classic technique. The teeth were radiographed and the images obtained were digitized. Linear measurements of the percentage of filling of the artificial lateral canals in each group were accomplished on the Image Tool 2.02 software. Statistical analysis of the data using Mann-Whitney U non-parametric test evidenced significant difference (p<0.01) between the experimental groups. The group obturated with TP medium points yielded higher percentage of filling of the lateral canals. It may be concluded that the use of master gutta-percha points with larger taper resulted in better filling of the simulated lateral canals, as compared to the use of standardized master gutta-percha points.


  • Open Access

    Influence of cervical preflaring on determination of apical file size in maxillary premolars: SEM analysis

    by Juliana Machado Barroso, Danilo M. Zanello Guerisoli, Alexandre Capelli, Paulo César Saquy, Jesus Djalma Pécora

    The purpose of this study was to investigate the influence of cervical preflaring on the determination of the first file that binds at working length (WL) in buccal roots of maxillary premolars. Five groups (n=10) were formed at random and, after standard access cavities, the WL was determined 1 mm short from the apex. In group 1, the initial apical file was inserted without preflaring of cervical and middle thirds of the root canals. In groups 2 to 5, the cervical and middle thirds were enlarged with sizes 90 and 110 Gates-Glidden drills, K³ Orifice Opener instruments, ProTaper instruments and LA Axxess burs, respectively. Canals were sized manually with K-files, starting with #08 K-files inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the instrument was recorded. Transversal sections of the WL regions were examined under scanning electron microscopy and the discrepancies between the canal diameter and first file to bind at the WL were assessed. Significant differences (p0.05) between their results (83.2 µm and 73.6 µm, respectively). The discrepancy for ProTaper instruments was 35.4 µm on average. In conclusion, the instrument binding technique for determination of the anatomical diameter at the WL was not precise. Preflaring of the cervical and middle thirds improved the determination of the anatomical diameter at the WL, and the type of instrument played a major role. Canals preflared with LA Axxess burs showed a more accurate binding of the files to anatomical diameter.