A. Khalil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. Khalil has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alain Arneodo
Ecole Normale Superieure de Lyon (France)
1 shared publication C. Aponte
1 shared publicationD. Engelman
1 shared publicationE. Atzema
University of Maine
1 shared publicationI. Dickey
1 shared publicationJ. L. Grant
University of Maine
1 shared publication
Latest Publications
- 17 March 2009
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 31 (7) , 775-783
Image analysis of soft-tissue in-growth and attachment into highly porous alumina ceramic foam metals
The detailed quantitative characterization of soft-tissue in-growth into highly porous artificial implants is critical to understanding the biophysical processes that will lead to the best structural scaffolding construct. Previous studies have performed mechanical peel tests and mostly qualitative histological analyses of soft-tissue. The goal of this paper is to report the results obtained from applying two image analysis algorithms to quantify the morphological structure found in histological images of stained soft-tissue in-growth into alumina ceramic foam metal implants using a canine model. Three different pore sizes were used and three different post-operative time points were considered. Using the 2D Wavelet Transform Modulus Maxima method and 2D Fourier Transform analysis, a strong anisotropic signature (directional preference) is detected in early (4-week) histological samples. The direction of preference is towards the center of the implants. The strength of the anisotropy at later time points (8 and 16 weeks) becomes gradually weaker. Our interpretation is that after a short period of time, the main tissue growth activity has been concentrated on filling the artificial implant by growing towards its center. The weaker anisotropic signature found at later time points is interpreted as the tissue growth activity strengthening its structure by growing in more random directions.
- 17 March 2009
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 31 (7) , 775-783
Image analysis of soft-tissue in-growth and attachment into highly porous alumina ceramic foam metals
The detailed quantitative characterization of soft-tissue in-growth into highly porous artificial implants is critical to understanding the biophysical processes that will lead to the best structural scaffolding construct. Previous studies have performed mechanical peel tests and mostly qualitative histological analyses of soft-tissue. The goal of this paper is to report the results obtained from applying two image analysis algorithms to quantify the morphological structure found in histological images of stained soft-tissue in-growth into alumina ceramic foam metal implants using a canine model. Three different pore sizes were used and three different post-operative time points were considered. Using the 2D Wavelet Transform Modulus Maxima method and 2D Fourier Transform analysis, a strong anisotropic signature (directional preference) is detected in early (4-week) histological samples. The direction of preference is towards the center of the implants. The strength of the anisotropy at later time points (8 and 16 weeks) becomes gradually weaker. Our interpretation is that after a short period of time, the main tissue growth activity has been concentrated on filling the artificial implant by growing towards its center. The weaker anisotropic signature found at later time points is interpreted as the tissue growth activity strengthening its structure by growing in more random directions.
- 16 October 2007
- Published by Springer Nature in Chromosome Research
- Vol. 15 (7) , 899-916
Chromosome territories have a highly nonspherical morphology and nonrandom positioning
Interphase chromosomes are organized into discrete chromosome territories (CTs) that may occupy preferred sub-nuclear positions. While chromosome size and gene density appear to influence positioning, the biophysical mechanisms behind CT localization, especially the relationship between morphology and positioning, remain obscure. One reason for this has been the difficulty in imaging, segmenting, and analyzing structures with variable or imprecise boundaries. This prompted us to develop a novel approach, based on the two-dimensional (2D) wavelet-transform modulus maxima (WTMM) method, adapted to perform objective and rigorous CT segmentation from nuclear background. The wavelet transform acts as a mathematical microscope to characterize spatial image information over a continuous range of size scales. This multiresolution nature, combined with full objectivity of the formalism, makes it more accurate than intensity-based segmentation algorithms and more appropriate than manual intervention. Using the WTMM method in combination with numerical simulation models, we show that CTs have a highly nonspherical 3D morphology, that CT positioning is nonrandom, and favors heterologous CT groupings. We discuss potential relationships between morphology, positioning, chromosomal function, and instability.
- 16 October 2007
- Published by Springer Nature in Chromosome Research
- Vol. 15 (7) , 899-916
Chromosome territories have a highly nonspherical morphology and nonrandom positioning
Interphase chromosomes are organized into discrete chromosome territories (CTs) that may occupy preferred sub-nuclear positions. While chromosome size and gene density appear to influence positioning, the biophysical mechanisms behind CT localization, especially the relationship between morphology and positioning, remain obscure. One reason for this has been the difficulty in imaging, segmenting, and analyzing structures with variable or imprecise boundaries. This prompted us to develop a novel approach, based on the two-dimensional (2D) wavelet-transform modulus maxima (WTMM) method, adapted to perform objective and rigorous CT segmentation from nuclear background. The wavelet transform acts as a mathematical microscope to characterize spatial image information over a continuous range of size scales. This multiresolution nature, combined with full objectivity of the formalism, makes it more accurate than intensity-based segmentation algorithms and more appropriate than manual intervention. Using the WTMM method in combination with numerical simulation models, we show that CTs have a highly nonspherical 3D morphology, that CT positioning is nonrandom, and favors heterologous CT groupings. We discuss potential relationships between morphology, positioning, chromosomal function, and instability.