Michael P. Hlastala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael P. Hlastala has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Joseph C. Anderson
Department of Bioengineering, University of Washington, Seattle, USA
4 shared publications - Karen B. Domino
University of Washington School of Medicine
3 shared publications - Robb W. Glenny
Departments of Medicine and Physiology & Biophysics, University of Washington, Seattle, WA, USA
3 shared publications H Thomas Robertson
2 shared publications- Hung Chang
Division of Thoracic Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan
2 shared publications Jack Hildebrandt
2 shared publications
Latest Publications
- 1 August 2016
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 121 (2) , 367-375
Alcohol breath test: gas exchange issues
The alcohol breath test is reviewed with a focus on gas exchange factors affecting its accuracy. The basis of the alcohol breath test is the assumption that alveolar air reaches the mouth during exhalation with no change in alcohol concentration. Recent investigations have shown that alcohol concentration is altered during its transit to the mouth. The exhaled alcohol concentration is modified by interaction with the mucosa of the pulmonary airways. Exhaled alcohol concentration is not an accurate indicator of alveolar alcohol concentration. Measuring alcohol concentration in the breath is very different process than measuring a blood level from air equilibrated with a blood sample. Airway exchange of alcohol leads to a bias against certain individuals depending on the anatomic and physiologic characteristics. Methodological modifications are proposed to improve the accuracy of the alcohol breath test to become fair to all.
- 1 August 2016
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 121 (2) , 367-375
Alcohol breath test: gas exchange issues
The alcohol breath test is reviewed with a focus on gas exchange factors affecting its accuracy. The basis of the alcohol breath test is the assumption that alveolar air reaches the mouth during exhalation with no change in alcohol concentration. Recent investigations have shown that alcohol concentration is altered during its transit to the mouth. The exhaled alcohol concentration is modified by interaction with the mucosa of the pulmonary airways. Exhaled alcohol concentration is not an accurate indicator of alveolar alcohol concentration. Measuring alcohol concentration in the breath is very different process than measuring a blood level from air equilibrated with a blood sample. Airway exchange of alcohol leads to a bias against certain individuals depending on the anatomic and physiologic characteristics. Methodological modifications are proposed to improve the accuracy of the alcohol breath test to become fair to all.
- Open Access
- 1 March 2013
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 114 (5) , 675-680
Airway exchange of highly soluble gases
Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in the terminal bronchioles to the end-exhaled partial pressure at the mouth. A mathematical model simulated the airway exchange of four gases (methyl isobutyl ketone, acetone, ethanol, and propylene glycol monomethyl ether) that have high water and blood solubility. The impact of solubility on the relative distribution of airway exchange was studied. We conclude that an increase in water solubility shifts the distribution of gas exchange toward the mouth. Of the four gases studied, ethanol had the greatest decrease in partial pressure from the alveolus to the mouth at end exhalation. Single exhalation breath tests are inappropriate for estimating alveolar levels of highly soluble gases, particularly for ethanol.
- 1 March 2013
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 114 (5) , 675-680
Open AccessAirway exchange of highly soluble gases
Highly blood soluble gases exchange with the bronchial circulation in the airways. On inhalation, air absorbs highly soluble gases from the airway mucosa and equilibrates with the blood before reaching the alveoli. Highly soluble gas partial pressure is identical throughout all alveoli. At the end of exhalation the partial pressure of a highly soluble gas decreases from the alveolar level in the terminal bronchioles to the end-exhaled partial pressure at the mouth. A mathematical model simulated the airway exchange of four gases (methyl isobutyl ketone, acetone, ethanol, and propylene glycol monomethyl ether) that have high water and blood solubility. The impact of solubility on the relative distribution of airway exchange was studied. We conclude that an increase in water solubility shifts the distribution of gas exchange toward the mouth. Of the four gases studied, ethanol had the greatest decrease in partial pressure from the alveolus to the mouth at end exhalation. Single exhalation breath tests are inappropriate for estimating alveolar levels of highly soluble gases, particularly for ethanol.
- 3 January 2011
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (1) , 268-269
Author’s Response
- 3 January 2011
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (1) , 268-269
Author’s Response
- 2 November 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (6) , 1665
Author’s Response
- 2 November 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (6) , 1665
Author’s Response
- 1 March 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (2) , 451-456
Paradigm Shift for the Alcohol Breath Test
The alcohol breath test (ABT) has been used for quantification of ethyl alcohol in individuals suspected of driving under the influence for more than 50 years. In this time, there has been little change in the concepts underlying this single breath test. The old model, which assumes that end-exhaled breath alcohol concentration is closely related to alveolar air alcohol concentration, is no longer acceptable. This paper reviews experimental research and mathematical modeling which has evaluated the pulmonary exchange processes for ethyl alcohol. Studies have shown that alcohol exchanges dynamically with the airway tissue both during inspiration and expiration. The airway tissue interaction makes it impossible to deliver air with alveolar alcohol concentration to the mouth. It is concluded that the ABT is dependent on physiological factors that need to be assessed for accurate testing.
- 1 March 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (2) , 451-456
Paradigm Shift for the Alcohol Breath Test
The alcohol breath test (ABT) has been used for quantification of ethyl alcohol in individuals suspected of driving under the influence for more than 50 years. In this time, there has been little change in the concepts underlying this single breath test. The old model, which assumes that end-exhaled breath alcohol concentration is closely related to alveolar air alcohol concentration, is no longer acceptable. This paper reviews experimental research and mathematical modeling which has evaluated the pulmonary exchange processes for ethyl alcohol. Studies have shown that alcohol exchanges dynamically with the airway tissue both during inspiration and expiration. The airway tissue interaction makes it impossible to deliver air with alveolar alcohol concentration to the mouth. It is concluded that the ABT is dependent on physiological factors that need to be assessed for accurate testing.
- 14 December 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 35 (2) , 264-272
The Impact of Breathing Pattern and Lung Size on the Alcohol Breath Test
Highly soluble gases exchange primarily with the bronchial circulation through pulmonary airway tissue. Because of this airway exchange, the assumption that end-exhaled alcohol concentration (EEAC) is equal to alveolar alcohol concentration (AAC) cannot be true. During exhalation, breath alcohol concentration (BrAC) decreases due to uptake of ethanol by the airway tissue. It is therefore impossible to deliver alveolar gas to the mouth during a single exhalation without losing alcohol to the airway mucosa. A consequence of airway alcohol exchange is that EEAC is always less than AAC. In this study, we use a mathematical model of the human lung to determine the influence of subject lung size on the relative reduction of BrAC from AAC. We find that failure to inspire a full inspiration reduces the BrAC at full exhalation, but increases the BrAC at minimum exhalation. In addition, a reduced inhaled volume and can lead to an inability to provide an adequate breath volume. We conclude that alcohol exchange with the airways during the single-exhalation breath test is dependent on lung size of the subject with a bias against subjects with smaller lung size.
- 14 December 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 35 (2) , 264-272
The Impact of Breathing Pattern and Lung Size on the Alcohol Breath Test
Highly soluble gases exchange primarily with the bronchial circulation through pulmonary airway tissue. Because of this airway exchange, the assumption that end-exhaled alcohol concentration (EEAC) is equal to alveolar alcohol concentration (AAC) cannot be true. During exhalation, breath alcohol concentration (BrAC) decreases due to uptake of ethanol by the airway tissue. It is therefore impossible to deliver alveolar gas to the mouth during a single exhalation without losing alcohol to the airway mucosa. A consequence of airway alcohol exchange is that EEAC is always less than AAC. In this study, we use a mathematical model of the human lung to determine the influence of subject lung size on the relative reduction of BrAC from AAC. We find that failure to inspire a full inspiration reduces the BrAC at full exhalation, but increases the BrAC at minimum exhalation. In addition, a reduced inhaled volume and can lead to an inability to provide an adequate breath volume. We conclude that alcohol exchange with the airways during the single-exhalation breath test is dependent on lung size of the subject with a bias against subjects with smaller lung size.
- 30 April 2006
- Vol. 49 (2) , 74-82
Ventilation and perfusion distribution during altered PEEP in the left lung in the left lateral decubitus posture with unchanged tidal volume in dogs.
Previous studies in anesthetized humans positioned in the left lateral decubitus (LLD) posture have shown that unilateral positive end-expiratory pressure (PEEP) to the dependent lung produce a more even ventilation distribution and improves gas exchange. Unilateral PEEP to the dependent lung may offer special advantages during LLD surgery by reducing the alveolar-to-arterial oxygen pressure difference {(A-a)PO2 or venous admixture} in patients with thoracic trauma or unilateral lung injury. We measured the effects of unilateral PEEP on regional distribution of blood flow (Q) and ventilation (V(A)) using fluorescent microspheres in pentobarbital anesthetized and air ventilation dogs in left lateral decubitus posture with synchronous lung inflation. Tidal volume to left and right lung is maintained constant to permit the effect on gas exchange to be examined. The addition of unilateral PEEP to the left lung increased its FRC with no change in left-right blood flow distribution or venous admixture. The overall lung V(A)/Q distribution remained relatively constant with increasing unilateral PEEP. Bilateral PEEP disproportionately increased FRC in the right lung but again produced no significant changes in venous admixture or V(A)/Q distribution. We conclude that the reduced dependent lung blood flow observed without PEEP occurs secondary to a reduction in lung volume. When tidal volume is maintained, unilateral PEEP increases dependent lung volume with little effect of perfusion distribution maintaining gas exchange.
- 30 April 2006
- Vol. 49 (2) , 74-82
Ventilation and perfusion distribution during altered PEEP in the left lung in the left lateral decubitus posture with unchanged tidal volume in dogs.
Previous studies in anesthetized humans positioned in the left lateral decubitus (LLD) posture have shown that unilateral positive end-expiratory pressure (PEEP) to the dependent lung produce a more even ventilation distribution and improves gas exchange. Unilateral PEEP to the dependent lung may offer special advantages during LLD surgery by reducing the alveolar-to-arterial oxygen pressure difference {(A-a)PO2 or venous admixture} in patients with thoracic trauma or unilateral lung injury. We measured the effects of unilateral PEEP on regional distribution of blood flow (Q) and ventilation (V(A)) using fluorescent microspheres in pentobarbital anesthetized and air ventilation dogs in left lateral decubitus posture with synchronous lung inflation. Tidal volume to left and right lung is maintained constant to permit the effect on gas exchange to be examined. The addition of unilateral PEEP to the left lung increased its FRC with no change in left-right blood flow distribution or venous admixture. The overall lung V(A)/Q distribution remained relatively constant with increasing unilateral PEEP. Bilateral PEEP disproportionately increased FRC in the right lung but again produced no significant changes in venous admixture or V(A)/Q distribution. We conclude that the reduced dependent lung blood flow observed without PEEP occurs secondary to a reduction in lung volume. When tidal volume is maintained, unilateral PEEP increases dependent lung volume with little effect of perfusion distribution maintaining gas exchange.
- 30 April 2006
- Vol. 49 (2) , 83-95
Redistribution of blood flow and lung volume between lungs in lateral decubitus postures during unilateral atelectasis and PEEP.
The effect of left lung atelectasis on the regional distribution of blood flow (Q), ventilation (V(A)) and gas exchange on the right lung ventilated with 100% O2 was studied in anesthetized dogs in the lateral decubitus posture. Q and V(A) were measured in 1.7 ml lung volume pieces using injected and aerosolized fluorescent microspheres, respectively. Hypoxic pulmonary vasoconstriction (HPV) in the atelectatic lung shifted flow to the ventilated lung. The increased flow in the ventilated lung ensured adequate gas exchange, compensating for the hypoxemia due to shunt contributed by the atelectatic lung. Left lung atelectasis caused a compensatory increase in the ventilated lung FRC that was smaller in the right (RLD) than left (LLD) lateral posture, the effect of lung compression by the atelectatic lung and mediastinal contents in the RLD posture. The O2 deficit measured by (A-a)DO2 increased with left lung atelectasis and was exacerbated in the LLD posture by 10 cm H2O PEEP, a result of increased shunt caused by a shift in Q from the ventilated to the atelectatic lung. The PEEP-induced O2 deficit was eliminated with inversion to the RLD posture.
- 30 April 2006
- Vol. 49 (2) , 83-95
Redistribution of blood flow and lung volume between lungs in lateral decubitus postures during unilateral atelectasis and PEEP.
The effect of left lung atelectasis on the regional distribution of blood flow (Q), ventilation (V(A)) and gas exchange on the right lung ventilated with 100% O2 was studied in anesthetized dogs in the lateral decubitus posture. Q and V(A) were measured in 1.7 ml lung volume pieces using injected and aerosolized fluorescent microspheres, respectively. Hypoxic pulmonary vasoconstriction (HPV) in the atelectatic lung shifted flow to the ventilated lung. The increased flow in the ventilated lung ensured adequate gas exchange, compensating for the hypoxemia due to shunt contributed by the atelectatic lung. Left lung atelectasis caused a compensatory increase in the ventilated lung FRC that was smaller in the right (RLD) than left (LLD) lateral posture, the effect of lung compression by the atelectatic lung and mediastinal contents in the RLD posture. The O2 deficit measured by (A-a)DO2 increased with left lung atelectasis and was exacerbated in the LLD posture by 10 cm H2O PEEP, a result of increased shunt caused by a shift in Q from the ventilated to the atelectatic lung. The PEEP-induced O2 deficit was eliminated with inversion to the RLD posture.
- Open Access
- 1 July 2005
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 99 (1) , 363-370
Regional hypoxic pulmonary vasoconstriction in prone pigs
Hypoxic pulmonary vasoconstriction (HPV) is known to affect regional pulmonary blood flow distribution. It is unknown whether lungs with well-matched ventilation (V̇)/perfusion (Q̇) have regional differences in the HPV response. Five prone pigs were anesthetized and mechanically ventilated (positive end-expiratory pressure = 2 cmH2O). Two hypoxic preconditions [inspired oxygen fraction (FiO2) = 0.13] were completed to stabilize the animal's hypoxic response. Regional pulmonary blood Q̇ and V̇ distribution was determined at various FiO2 (0.21, 0.15, 0.13, 0.11, 0.09) using the fluorescent microsphere technique. Q̇ and V̇ in the lungs were quantified within 2-cm3 lung pieces. Pieces were grouped, or clustered, based on the changes in blood flow when subjected to increasing hypoxia. Unique patterns of Q̇ response to hypoxia were seen within and across animals. The three main patterns (clusters) showed little initial difference in V̇/Q̇ matching at room air where the mean V̇/Q̇ range was 0.92–1.06. The clusters were spatially located in cranial, central, and caudal portions of the lung. With decreasing FiO2, blood flow shifted from the cranial to caudal regions. We determined that pulmonary blood flow changes, caused by HPV, produced distinct response patterns that were seen in similar regions across our prone porcine model.
- 1 July 2005
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 99 (1) , 363-370
Open AccessRegional hypoxic pulmonary vasoconstriction in prone pigs
Hypoxic pulmonary vasoconstriction (HPV) is known to affect regional pulmonary blood flow distribution. It is unknown whether lungs with well-matched ventilation (V̇)/perfusion (Q̇) have regional differences in the HPV response. Five prone pigs were anesthetized and mechanically ventilated (positive end-expiratory pressure = 2 cmH2O). Two hypoxic preconditions [inspired oxygen fraction (FiO2) = 0.13] were completed to stabilize the animal's hypoxic response. Regional pulmonary blood Q̇ and V̇ distribution was determined at various FiO2 (0.21, 0.15, 0.13, 0.11, 0.09) using the fluorescent microsphere technique. Q̇ and V̇ in the lungs were quantified within 2-cm3 lung pieces. Pieces were grouped, or clustered, based on the changes in blood flow when subjected to increasing hypoxia. Unique patterns of Q̇ response to hypoxia were seen within and across animals. The three main patterns (clusters) showed little initial difference in V̇/Q̇ matching at room air where the mean V̇/Q̇ range was 0.92–1.06. The clusters were spatially located in cranial, central, and caudal portions of the lung. With decreasing FiO2, blood flow shifted from the cranial to caudal regions. We determined that pulmonary blood flow changes, caused by HPV, produced distinct response patterns that were seen in similar regions across our prone porcine model.
- Open Access
- 1 May 2004
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 96 (5) , 1589-1599
Spatial distribution of hypoxic pulmonary vasoconstriction in the supine pig
Hypoxic pulmonary vasoconstriction (HPV) serves to maintain optimal gas exchange by decreasing perfusion to hypoxic regions. However, global hypoxia and nonuniform HPV may result in overperfusion of poorly constricted regions leading to local edema seen in high-altitude pulmonary edema. To quantify the spatial distribution of HPV and its response to regional Po2 (PrO2) among small lung regions, five pigs were anesthetized and mechanically ventilated in the supine posture. The animals were ventilated with an inspired O2 fraction (FiO2) of 0.50 and 0.21 and then (in random order) 0.15, 0.12, and 0.09. Regional blood flow (Q̇) and alveolar ventilation (V̇a) were measured by using intravenous infusion of 15 μm and inhalation of 1-μm fluorescent microspheres, respectively. PrO2 was calculated for each piece at each FiO2. Lung pieces differed in their Q̇ response to hypoxia in a manner related to their initial V̇a/Q̇ with FiO2 = 0.21. Reducing FiO2 < 0.15 decreased Q̇ to the initially high V̇a/Q̇ (higher PrO2) regions and forced Q̇ into the low V̇a/Q̇ (dorsal-caudal) regions. Resistance increased in most lung pieces as PrO2 decreased, reaching a maximum resistance when PrO2 is between 40 and 50 Torr. Local resistance decreased at Pro2 < 40 Torr. Pieces were statistically clustered with respect to their relative Q̇ response pattern to each FiO2. Some clusters were shown to be spatially organized. We conclude that HPV is spatially heterogeneous. The heterogeneity of Q̇ response may be related, in part, to the heterogeneity of baseline V̇a/Q̇.
- 1 May 2004
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 96 (5) , 1589-1599
Open AccessSpatial distribution of hypoxic pulmonary vasoconstriction in the supine pig
Hypoxic pulmonary vasoconstriction (HPV) serves to maintain optimal gas exchange by decreasing perfusion to hypoxic regions. However, global hypoxia and nonuniform HPV may result in overperfusion of poorly constricted regions leading to local edema seen in high-altitude pulmonary edema. To quantify the spatial distribution of HPV and its response to regional Po2 (PrO2) among small lung regions, five pigs were anesthetized and mechanically ventilated in the supine posture. The animals were ventilated with an inspired O2 fraction (FiO2) of 0.50 and 0.21 and then (in random order) 0.15, 0.12, and 0.09. Regional blood flow (Q̇) and alveolar ventilation (V̇a) were measured by using intravenous infusion of 15 μm and inhalation of 1-μm fluorescent microspheres, respectively. PrO2 was calculated for each piece at each FiO2. Lung pieces differed in their Q̇ response to hypoxia in a manner related to their initial V̇a/Q̇ with FiO2 = 0.21. Reducing FiO2 < 0.15 decreased Q̇ to the initially high V̇a/Q̇ (higher PrO2) regions and forced Q̇ into the low V̇a/Q̇ (dorsal-caudal) regions. Resistance increased in most lung pieces as PrO2 decreased, reaching a maximum resistance when PrO2 is between 40 and 50 Torr. Local resistance decreased at Pro2 < 40 Torr. Pieces were statistically clustered with respect to their relative Q̇ response pattern to each FiO2. Some clusters were shown to be spatially organized. We conclude that HPV is spatially heterogeneous. The heterogeneity of Q̇ response may be related, in part, to the heterogeneity of baseline V̇a/Q̇.