Venkataraman Dharuman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Venkataraman Dharuman has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Habibulla Imran
Graduate School of Flexible and Printable Electronics, LANL-JBNU Engineering Institute-Korea, Jeonbuk National University, Jeonju, 54896, Republic of Korea
6 shared publicationsPalinci Nagarajan Manikandan
Molecular Electronics Laboratory, Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi 630 003, India; Fedesens Centre for Innovation and Instrumentation, Chennai 600024, India
6 shared publicationsSebastinbaskar Aniu Lincy
Molecular Electronics Laboratory, Department of Bioelectronics and Biosensors, Science Campus, Alagappa University, Karaikudi 630003, Tamil Nadu, India
6 shared publicationsYesurajan Allwin Richard
Molecular Electronics Laboratory, Department of Bioelectronics and Biosensors, Science Campus, Alagappa University, Karaikudi 630003, Tamil Nadu, India
6 shared publicationsMohanlal Bhuvana
Molecular Electronics Laboratory, Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi 630003, India
3 shared publicationsShakkthivel Piraman
Sustainable Energy and Smart Materials Research Lab, Department of Nanoscience and Technology, Alagappa University, Science Campus, Karaikudi – 630 003, India
3 shared publications
Latest Publications
- 26 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (48) , 15492-15505
CVD-grown MXene–CNT nanocomposite-assisted electrochemical immunosensors for label-free and ultra-sensitive monitoring of thyroid-stimulating hormone in artificial serum
A CVD-grown 3D MXene–CNT nanocomposite enables a robust, antifouling electrochemical interface for covalent antibody binding and label-free, ultra-sensitive TSH detection in artificial serum.
- 26 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (48) , 15492-15505
CVD-grown MXene–CNT nanocomposite-assisted electrochemical immunosensors for label-free and ultra-sensitive monitoring of thyroid-stimulating hormone in artificial serum
A CVD-grown 3D MXene–CNT nanocomposite enables a robust, antifouling electrochemical interface for covalent antibody binding and label-free, ultra-sensitive TSH detection in artificial serum.
- 22 September 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 329 (Pt 2) , 147736
Portable and wireless DNA nanosensor for early detection of lung cancer using ultrafast synthesis of 1T-MoS2/liposome-AuNP modified transducer
- 22 September 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 329 (Pt 2) , 147736
Portable and wireless DNA nanosensor for early detection of lung cancer using ultrafast synthesis of 1T-MoS2/liposome-AuNP modified transducer
- Open Access
- 17 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 617
Sensitive and Selective Electrochemical Detection of Hydrogen Peroxide Using a Silver-Incorporated CeO2/Ag2O Nanocomposite
Precision and real-time detection of hydrogen peroxide (H2O2) are essential in pharmaceutical, industrial, and defence sectors due to its strong oxidizing nature. In this study, silver (Ag)-doped CeO2/Ag2O-modified glassy carbon electrode (Ag-CeO2/Ag2O/GCE) has been developed as a non-enzymatic electrochemical sensor for the sensitive and selective detection of H2O2. The synthesized Ag-doped CeO2/Ag2O nanocomposite was characterized using various advanced techniques, including X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), field-emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HR-TEM). Their optical, magnetic, thermal, and chemical properties were further analyzed using UV–vis spectroscopy, electron paramagnetic resonance (EPR), thermogravimetric-differential thermal analysis (TG-DTA), and X-ray photoelectron spectroscopy (XPS). Electrochemical sensing performance was evaluated using cyclic voltammetry and amperometry. The Ag-CeO2/Ag2O/GCE exhibited superior electrocatalytic activity for H2O2, attributed to the increased number of active sites and enhanced electron transfer. The sensor displayed a high sensitivity of 2.728 µA cm−2 µM−1, significantly outperforming the undoped CeO2/GCE (0.0404 µA cm−2 µM−1). The limit of detection (LOD) and limit of quantification (LOQ) were found to be 6.34 µM and 21.1 µM, respectively, within a broad linear detection range of 1 × 10−8 to 0.5 × 10−3 M. The sensor also demonstrated excellent selectivity with minimal interference from common analytes, along with outstanding storage stability, reproducibility, and repeatability. Owing to these attributes, the Ag-CeO2/Ag2O/GCE sensor proved effective for real sample analysis, showcasing its potential as a reliable, non-enzymatic platform for H2O2 detection.
- 17 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 617
Open AccessSensitive and Selective Electrochemical Detection of Hydrogen Peroxide Using a Silver-Incorporated CeO2/Ag2O Nanocomposite
Precision and real-time detection of hydrogen peroxide (H2O2) are essential in pharmaceutical, industrial, and defence sectors due to its strong oxidizing nature. In this study, silver (Ag)-doped CeO2/Ag2O-modified glassy carbon electrode (Ag-CeO2/Ag2O/GCE) has been developed as a non-enzymatic electrochemical sensor for the sensitive and selective detection of H2O2. The synthesized Ag-doped CeO2/Ag2O nanocomposite was characterized using various advanced techniques, including X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), field-emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HR-TEM). Their optical, magnetic, thermal, and chemical properties were further analyzed using UV–vis spectroscopy, electron paramagnetic resonance (EPR), thermogravimetric-differential thermal analysis (TG-DTA), and X-ray photoelectron spectroscopy (XPS). Electrochemical sensing performance was evaluated using cyclic voltammetry and amperometry. The Ag-CeO2/Ag2O/GCE exhibited superior electrocatalytic activity for H2O2, attributed to the increased number of active sites and enhanced electron transfer. The sensor displayed a high sensitivity of 2.728 µA cm−2 µM−1, significantly outperforming the undoped CeO2/GCE (0.0404 µA cm−2 µM−1). The limit of detection (LOD) and limit of quantification (LOQ) were found to be 6.34 µM and 21.1 µM, respectively, within a broad linear detection range of 1 × 10−8 to 0.5 × 10−3 M. The sensor also demonstrated excellent selectivity with minimal interference from common analytes, along with outstanding storage stability, reproducibility, and repeatability. Owing to these attributes, the Ag-CeO2/Ag2O/GCE sensor proved effective for real sample analysis, showcasing its potential as a reliable, non-enzymatic platform for H2O2 detection.
- 11 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (33) , 16568-16579
Nitrogen and Sulfur Simultaneously Doped Cobalt Oxide-Decorated Hollow Carbon Nanospheres for Electrochemical Detection of Chloramphenicol
- 11 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (33) , 16568-16579
Nitrogen and Sulfur Simultaneously Doped Cobalt Oxide-Decorated Hollow Carbon Nanospheres for Electrochemical Detection of Chloramphenicol
- 3 December 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 163, 108871
In-vitro sensing of traumatic brain tissue by electrochemical impedance for diagnosis and therapeutic
- 3 December 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 163, 108871
In-vitro sensing of traumatic brain tissue by electrochemical impedance for diagnosis and therapeutic
- 21 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 12 (1) , 909-923
Electrochemical investigation of an antipyretic drug in plant extracts and environmental samples at the O-MWCNT/CuO nanostructure modified glassy carbon electrode
Opened multiwalled carbon nanotubes (O-MWCNT) were prepared by unzipping MWCNTs using Hummers' method and decorated with CuO to form a nanohybrid (O-MWCNT/CuO) through a simple co-precipitation technique, aimed at developing a novel electrochemical sensor. The O-MWCNT/CuO composite was used to modify a glassy carbon electrode (GCE) for the sensitive detection of the antipyretic drug acetaminophen (ACT) in various matrices. O-MWCNT/CuO was characterized using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), UV-visible spectroscopy, cyclic voltammetry (CV), linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS), which confirmed the successful formation of the nanocomposite as well as its electrical conductivity and catalytic properties. The sensor demonstrates a wide linear detection range (0.005–1450 μM), with a low detection limit (LOD) of 7.2 nM and excellent sensitivity of 0.019 μA cm−2 μM−1. Additionally, the sensor demonstrated good stability (maintaining performance over 65 cycles) and selectivity in various co-interfering compounds. Notably, the electrochemical sensor was applied for the detection of ACT in environmental water samples, pharmaceutical formulations, human biological fluids, and fenugreek plant extracts, achieving good recovery rates (97.37–100.20%) with relative standard deviations (RSD) ranging from 1.0% to 3.3%, using the standard addition method. The novelty of this work lies in the development of a highly sensitive, stable, and selective GCE-modified sensor for ACT detection, with promising applications in real-world sample analysis.
- 21 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 12 (1) , 909-923
Electrochemical investigation of an antipyretic drug in plant extracts and environmental samples at the O-MWCNT/CuO nanostructure modified glassy carbon electrode
Opened multiwalled carbon nanotubes (O-MWCNT) were prepared by unzipping MWCNTs using Hummers' method and decorated with CuO to form a nanohybrid (O-MWCNT/CuO) through a simple co-precipitation technique, aimed at developing a novel electrochemical sensor. The O-MWCNT/CuO composite was used to modify a glassy carbon electrode (GCE) for the sensitive detection of the antipyretic drug acetaminophen (ACT) in various matrices. O-MWCNT/CuO was characterized using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), UV-visible spectroscopy, cyclic voltammetry (CV), linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS), which confirmed the successful formation of the nanocomposite as well as its electrical conductivity and catalytic properties. The sensor demonstrates a wide linear detection range (0.005–1450 μM), with a low detection limit (LOD) of 7.2 nM and excellent sensitivity of 0.019 μA cm−2 μM−1. Additionally, the sensor demonstrated good stability (maintaining performance over 65 cycles) and selectivity in various co-interfering compounds. Notably, the electrochemical sensor was applied for the detection of ACT in environmental water samples, pharmaceutical formulations, human biological fluids, and fenugreek plant extracts, achieving good recovery rates (97.37–100.20%) with relative standard deviations (RSD) ranging from 1.0% to 3.3%, using the standard addition method. The novelty of this work lies in the development of a highly sensitive, stable, and selective GCE-modified sensor for ACT detection, with promising applications in real-world sample analysis.
- 1 February 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (2) , 027517
Ca-MOF-Polymer Modified Thin-Film Electrode for Detection of Toxic Cadmium (Cd2+) in Biofluid and Environmental Fluid
Competitive adsorption of Cd2+ on the cell leads different diseases like kidney damage and osteoporosis. It is crucial for Cd2+ intake that ambient and biofluid supplies of Cd2+ be contained. For this, Calcium based Metal Organic Framework (Ca-MOF) was developed by hydrothermal methods using bidendate 1,4-benzene dicarboxylic acid (BDC) and Calcium derived from biowaste chicken egg shells. Lower binding efficiency of Cd2+ with the undoped MOF is improved by complexing it with polyaniline (PANI) to generate Ca-MOF-PANI which provide amine functional groups. These are characterized by Cyclic Voltammetry (CV), Ultra-violet Visible (UV–vis) spectroscopy, Scanning and transmission electron microscopy (SEM and TEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR) spectroscopy. Electrochemical sensing showed an irreversible oxidation peak for Cd2+ at −0.75 V. The Ca-MOF-PANI showed higher Cd2+ sensing than the CaCO3, Ca-MOF and PANI modified electrodes and confirmed by UV–vis studies. The sensor showed lowest detection limit (LOD) of 138 nM (25.3 ppb) with linearity range 0.1–2000 μM, respectively, high selectivity in presence of potential interferences, good reproducibility, stability, and repeatability features. Real sample analysis using urine and water samples indicates good signal recoveries ranged from 93.0% to 112.0%.
- 1 February 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (2) , 027517
Ca-MOF-Polymer Modified Thin-Film Electrode for Detection of Toxic Cadmium (Cd2+) in Biofluid and Environmental Fluid
Competitive adsorption of Cd2+ on the cell leads different diseases like kidney damage and osteoporosis. It is crucial for Cd2+ intake that ambient and biofluid supplies of Cd2+ be contained. For this, Calcium based Metal Organic Framework (Ca-MOF) was developed by hydrothermal methods using bidendate 1,4-benzene dicarboxylic acid (BDC) and Calcium derived from biowaste chicken egg shells. Lower binding efficiency of Cd2+ with the undoped MOF is improved by complexing it with polyaniline (PANI) to generate Ca-MOF-PANI which provide amine functional groups. These are characterized by Cyclic Voltammetry (CV), Ultra-violet Visible (UV–vis) spectroscopy, Scanning and transmission electron microscopy (SEM and TEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR) spectroscopy. Electrochemical sensing showed an irreversible oxidation peak for Cd2+ at −0.75 V. The Ca-MOF-PANI showed higher Cd2+ sensing than the CaCO3, Ca-MOF and PANI modified electrodes and confirmed by UV–vis studies. The sensor showed lowest detection limit (LOD) of 138 nM (25.3 ppb) with linearity range 0.1–2000 μM, respectively, high selectivity in presence of potential interferences, good reproducibility, stability, and repeatability features. Real sample analysis using urine and water samples indicates good signal recoveries ranged from 93.0% to 112.0%.
- 31 August 2023
- Published by Springer Nature
- p. 763-788
Carbon Nanodots-Based Electrodes in Biomolecular Screening and Analysis
- 31 August 2023
- Published by Springer Nature
- p. 763-788
Carbon Nanodots-Based Electrodes in Biomolecular Screening and Analysis
- 7 January 2023
- Published by Elsevier in Bioelectrochemistry
- Vol. 150, 108371
Label-free electrochemical detection of cancer biomarkers DNA and anti-p53 at tin oxide quantum dot-gold-DNA nanoparticle modified electrode
- 7 January 2023
- Published by Elsevier in Bioelectrochemistry
- Vol. 150, 108371
Label-free electrochemical detection of cancer biomarkers DNA and anti-p53 at tin oxide quantum dot-gold-DNA nanoparticle modified electrode
- 23 October 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 219, 114849
Streptavidin Fe2O3-gold nanoparticles functionalized theranostic liposome for antibiotic resistant bacteria and biotin sensing
- 23 October 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 219, 114849
Streptavidin Fe2O3-gold nanoparticles functionalized theranostic liposome for antibiotic resistant bacteria and biotin sensing