Brad H. Thompson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brad H. Thompson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
William Stanford
3 shared publications- Eric A. Hoffman
Department of Radiology, University of Iowa, Iowa City, Iowa
1 shared publication Greg Petersen
Univ. of Iowa College of Medicine (United States)
1 shared publicationJehangir K. Tajik
Univ. of Iowa College of Medicine (United States)
1 shared publicationTimmothy J. Reiners
Univ. of Iowa College of Medicine (United States)
1 shared publication- William Stanford
Department of Radiology, University of Iowa College of Medicine, Iowa City, IA 52242
1 shared publication
Latest Publications
- 1 July 2005
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 3 (4) , 681-689
Assessment of cardiac function by electron-beam computed tomography
The measurement of parameters relating to the assessment of cardiac function and morphology are critically important prognostic determinates in patients with known or suspected cardiac disease, such as coronary artery disease and myocardial infarction. Similarly, the measurement of indices, such as ejection fraction and myocardial mass, are key in assessing the efficacy of therapy in patients with valvular, coronary artery and intrinsic myocardial diseases. Electron-beam computed tomography has been proven to be a reliable and accurate modality for measuring a host of parameters relating to cardiac function. This article reviews the unique technologic design of the electron-beam computed tomography scanner and specifically addresses how this technology has enabled electron-beam computed tomography to become the gold standard for the quantification of cardiac function.
- 1 July 2005
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 3 (4) , 681-689
Assessment of cardiac function by electron-beam computed tomography
The measurement of parameters relating to the assessment of cardiac function and morphology are critically important prognostic determinates in patients with known or suspected cardiac disease, such as coronary artery disease and myocardial infarction. Similarly, the measurement of indices, such as ejection fraction and myocardial mass, are key in assessing the efficacy of therapy in patients with valvular, coronary artery and intrinsic myocardial diseases. Electron-beam computed tomography has been proven to be a reliable and accurate modality for measuring a host of parameters relating to cardiac function. This article reviews the unique technologic design of the electron-beam computed tomography scanner and specifically addresses how this technology has enabled electron-beam computed tomography to become the gold standard for the quantification of cardiac function.
- 1 February 2005
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 21 (1) , 39-53
Update on using coronary calcium screening by computed tomography to measure risk for coronary heart disease
Coronary artery disease (CAD) is the number one killer of adults in the United States, claiming one-half million deaths annually. Early detection and prevention strategies clearly remain a top priority for health care providers in order to reduce the high mortality rate of heart disease. As an unequivocal reflection of arteriosclerosis, coronary arterial calcium (CAC) may provide a means to qualitatively assess the overall disease severity and likewise serve as a means to assess risk for CHD. It is known that patients with heavy calcium burdens have more advanced CAD, a concomitantly a higher likelihood of coronary stenoses, and a concomitant higher risk for acute cardiac events. Computed tomography has been shown to be an accurate, non-invasive method to quantify coronary calcification burden in patients. Evidence shows that calcium measurements by CT correlate well with histological plaque analyses, and that CAC measurements accurately reflect disease severity and can be useful to assess individual risk for CHD. The purpose of this article is to summarize the currently available evidence that has attempted to validate CAC screening as a screening exam and risk predictor for coronary heart disease.
- 1 February 2005
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 21 (1) , 39-53
Update on using coronary calcium screening by computed tomography to measure risk for coronary heart disease
Coronary artery disease (CAD) is the number one killer of adults in the United States, claiming one-half million deaths annually. Early detection and prevention strategies clearly remain a top priority for health care providers in order to reduce the high mortality rate of heart disease. As an unequivocal reflection of arteriosclerosis, coronary arterial calcium (CAC) may provide a means to qualitatively assess the overall disease severity and likewise serve as a means to assess risk for CHD. It is known that patients with heavy calcium burdens have more advanced CAD, a concomitantly a higher likelihood of coronary stenoses, and a concomitant higher risk for acute cardiac events. Computed tomography has been shown to be an accurate, non-invasive method to quantify coronary calcification burden in patients. Evidence shows that calcium measurements by CT correlate well with histological plaque analyses, and that CAC measurements accurately reflect disease severity and can be useful to assess individual risk for CHD. The purpose of this article is to summarize the currently available evidence that has attempted to validate CAC screening as a screening exam and risk predictor for coronary heart disease.
- 24 May 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (6) , 720-733
Imaging of coronary calcification by computed tomography
As an unequivocal biomarker for arteriosclerosis, the presence of coronary calcium serves as a qualitative reflection of the severity of coronary artery disease (CAD). Greater calcium burdens correlate with more advanced disease, a higher likelihood of coronary stenoses, and a higher risk for coronary heart disease (CHD). Empirically, the quantification of coronary calcium not only provides an accurate reflection of disease severity, but also has great potential as a screening tool for CHD. Computed tomography (CT) has been shown to be capable of providing accurate, noninvasive measurements of coronary calcification. Evidence shows that calcium measurements by CT correlate well with histological plaque analyses, and that calcium burdens accurately reflect disease severity and can be used to assess individual risk for CHD. The purpose of this review article is to examine the accumulated evidence that has attempted to validate CT as a diagnostic tool for CAD and as a screening exam for CHD. J. Magn. Reson. Imaging 2004;19:720–733.
- 24 May 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (6) , 720-733
Imaging of coronary calcification by computed tomography
As an unequivocal biomarker for arteriosclerosis, the presence of coronary calcium serves as a qualitative reflection of the severity of coronary artery disease (CAD). Greater calcium burdens correlate with more advanced disease, a higher likelihood of coronary stenoses, and a higher risk for coronary heart disease (CHD). Empirically, the quantification of coronary calcium not only provides an accurate reflection of disease severity, but also has great potential as a screening tool for CHD. Computed tomography (CT) has been shown to be capable of providing accurate, noninvasive measurements of coronary calcification. Evidence shows that calcium measurements by CT correlate well with histological plaque analyses, and that calcium burdens accurately reflect disease severity and can be used to assess individual risk for CHD. The purpose of this review article is to examine the accumulated evidence that has attempted to validate CT as a diagnostic tool for CAD and as a screening exam for CHD. J. Magn. Reson. Imaging 2004;19:720–733.
- 24 May 1995
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2433, 26-37
Perfusion deficit versus anatomic visualization in detection of pulmonary emboli via electron-beam CT: validation in swine
We present here our initial findings regarding the utility of functional x-ray CT imaging in determining the presence of pulmonary emboli. Recently, x-ray CT has been reported to be a promising technique in detecting pulmonary emboli through direct visualization of the clot as a filling defect of the reconstructed vascular lumen with CT scanning occurring during i.v. contrast drip. To determine whether functional imaging via the dynamic mode of electron beam CT might add to the sensitivity and specificity of pulmonary emboli diagnosis through the visualization of pulmonary parenchymal blood flow and its associated temporal parameters, we scanned 32 pigs and report here our findings on 17 pigs evaluated to date. Findings to date show that the evaluation of flow deficits detected via electron beam CT with a small 2-3 sec. bolus contrast injection has the potential to provide improvement in embolus detection over visual inspection of this section CT/continuous infusion contrast where the viewer is looking for unenhanced regions in the pulmonary arteries.
- 24 May 1995
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2433, 26-37
Perfusion deficit versus anatomic visualization in detection of pulmonary emboli via electron-beam CT: validation in swine
We present here our initial findings regarding the utility of functional x-ray CT imaging in determining the presence of pulmonary emboli. Recently, x-ray CT has been reported to be a promising technique in detecting pulmonary emboli through direct visualization of the clot as a filling defect of the reconstructed vascular lumen with CT scanning occurring during i.v. contrast drip. To determine whether functional imaging via the dynamic mode of electron beam CT might add to the sensitivity and specificity of pulmonary emboli diagnosis through the visualization of pulmonary parenchymal blood flow and its associated temporal parameters, we scanned 32 pigs and report here our findings on 17 pigs evaluated to date. Findings to date show that the evaluation of flow deficits detected via electron beam CT with a small 2-3 sec. bolus contrast injection has the potential to provide improvement in embolus detection over visual inspection of this section CT/continuous infusion contrast where the viewer is looking for unenhanced regions in the pulmonary arteries.