George A. Levin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
George A. Levin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Paul N. Barnes
Air Force Res. Lab., Wright-Patterson AFB, OH, USA
7 shared publications - Naoyuki Amemiya
Kyoto University
3 shared publications P. Mozola
3 shared publicationsJ. Kvitkovic
Inst. of Electr. Eng., Slovak Acad. of Sci., Bratislava
2 shared publicationsK. Yoda
Yokohama National University Faculty of Engineering 79-5 Tokiwadai, Hodogaya, Yokohama 240-8501, Japan
2 shared publicationsM. Polak
Inst. of Electr. Eng., Slovak Acad. of Sci., Bratislava
2 shared publications
Latest Publications
- 20 January 2011
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 24 (3)
The effects of superconductor–stabilizer interfacial resistance on quenching of a pancake coil made out of coated conductor
- 20 January 2011
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 24 (3)
The effects of superconductor–stabilizer interfacial resistance on quenching of a pancake coil made out of coated conductor
- 1 January 2010
- Published by AIP Publishing
THE EFFECT OF A FILAMENT INTERRUPTION ON CURRENT-VOLTAGE CURVES AND CRITICAL CURRENTS OF FILAMENTARY YBCO TAPES WITH SUPERCONDUCTING BRIDGES
The interruption of a filament in filamentary YBCOconductors reduces the critical current of the tape along the whole length of the tape. Multiply connected filamentary YBCOsuperconducting tapes were previously proposed as a means to allow current sharing between filaments in case of such interruption. To study the efficiency of such architecture, we studied the I‐V curves and critical currents of model filamentary YBCO tapes with 10 filaments ∼1 mm wide, which were interconnected by several superconducting bridges. The effect of a break in one or more filaments on the I‐V curves, n‐factor, and critical current of the model tape was measured and reported. The effect of the contact arrangements on the current distribution in the filaments of the tape was also studied.
- 1 January 2010
- Published by AIP Publishing
THE EFFECT OF A FILAMENT INTERRUPTION ON CURRENT-VOLTAGE CURVES AND CRITICAL CURRENTS OF FILAMENTARY YBCO TAPES WITH SUPERCONDUCTING BRIDGES
The interruption of a filament in filamentary YBCOconductors reduces the critical current of the tape along the whole length of the tape. Multiply connected filamentary YBCOsuperconducting tapes were previously proposed as a means to allow current sharing between filaments in case of such interruption. To study the efficiency of such architecture, we studied the I‐V curves and critical currents of model filamentary YBCO tapes with 10 filaments ∼1 mm wide, which were interconnected by several superconducting bridges. The effect of a break in one or more filaments on the I‐V curves, n‐factor, and critical current of the model tape was measured and reported. The effect of the contact arrangements on the current distribution in the filaments of the tape was also studied.
- Open Access
- 23 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2504-2507
Stability and Normal Zone Propagation Speed in YBCO Coated Conductors With Increased Interfacial Resistance
We will discuss how stability and speed of normal zone propagation in YBCO-coated conductors is affected by interfacial resistance between the superconducting film and the stabilizer. Our numerical simulation has shown that the increased interfacial resistance substantially increases speed of normal zone propagation and decreases the stability margins. Optimization of the value of the resistance may lead to a better compromise between stability and quench protection requirements than what is found in currently manufactured coated conductors.
- 23 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 2504-2507
Open AccessStability and Normal Zone Propagation Speed in YBCO Coated Conductors With Increased Interfacial Resistance
We will discuss how stability and speed of normal zone propagation in YBCO-coated conductors is affected by interfacial resistance between the superconducting film and the stabilizer. Our numerical simulation has shown that the increased interfacial resistance substantially increases speed of normal zone propagation and decreases the stability margins. Optimization of the value of the resistance may lead to a better compromise between stability and quench protection requirements than what is found in currently manufactured coated conductors.
- 3 September 2008
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 21 (11)
Dynamic investigation of the transport current in YBa2Cu3O7−δthin films
- 3 September 2008
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 21 (11)
Dynamic investigation of the transport current in YBa2Cu3O7−δthin films
- 11 August 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (6) , 062504
Persistent current in coils made out of second generation high temperature superconductor wire.
We report the results of an experimental study of a persistent coil made out of coated conductors. The magnitude of the persistent current and the rate of decay were investigated. Two distinct modes of relaxation are evident—one is flux creep and the other, which is much faster, is of less obvious origin. Our conclusion is that the persistent current in such a coil can be large enough and decay slowly enough so that coated conductors can be used to make persistent coils for variety of applications.- 11 August 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (6) , 062504
Persistent current in coils made out of second generation high temperature superconductor wire.
We report the results of an experimental study of a persistent coil made out of coated conductors. The magnitude of the persistent current and the rate of decay were investigated. Two distinct modes of relaxation are evident—one is flux creep and the other, which is much faster, is of less obvious origin. Our conclusion is that the persistent current in such a coil can be large enough and decay slowly enough so that coated conductors can be used to make persistent coils for variety of applications.- 6 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 1240-1244
Properties of an Experimental Coil Wound With YBCO Coated Conductor Carrying an AC Current With Frequencies up to 864 Hz
To study the properties of coils made out of the second generation superconducting wire, we designed, manufactured and tested an experimental double pancake coil wound with 4.2 meters of a 4 mm wide, copper stabilized YBCO coated conductor. The critical current of a short sample was 53 A at 77 K in self-field. The critical current of the single pancake coil based on the 1 V/cm criterion for the average electric field was approximately 30 A. The critical current of the complete double pancake was about 23 A. Using micro Hall probes, we measured the radial magnetic field component at the edges of the coil. The results clearly indicated the strong influence of the magnetization currents on the magnitude and distribution of the radial field component. AC losses in the coil were measured at frequencies of 54 Hz, 108 Hz, 216 Hz, 432 Hz and 864 Hz. At the critical current (16.2 A) and frequency 432 Hz the coil losses were 0.9 W. The magnetic measurements showed that the tape in the winding is exposed to a very inhomogeneous magnetic field. The experimental results of the field distribution in the winding were compared with the existing theoretical models.
- 6 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 1240-1244
Properties of an Experimental Coil Wound With YBCO Coated Conductor Carrying an AC Current With Frequencies up to 864 Hz
To study the properties of coils made out of the second generation superconducting wire, we designed, manufactured and tested an experimental double pancake coil wound with 4.2 meters of a 4 mm wide, copper stabilized YBCO coated conductor. The critical current of a short sample was 53 A at 77 K in self-field. The critical current of the single pancake coil based on the 1 V/cm criterion for the average electric field was approximately 30 A. The critical current of the complete double pancake was about 23 A. Using micro Hall probes, we measured the radial magnetic field component at the edges of the coil. The results clearly indicated the strong influence of the magnetization currents on the magnitude and distribution of the radial field component. AC losses in the coil were measured at frequencies of 54 Hz, 108 Hz, 216 Hz, 432 Hz and 864 Hz. At the critical current (16.2 A) and frequency 432 Hz the coil losses were 0.9 W. The magnetic measurements showed that the tape in the winding is exposed to a very inhomogeneous magnetic field. The experimental results of the field distribution in the winding were compared with the existing theoretical models.
- 6 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 1597-1600
Current Distribution in the Winding of a Superconducting Coil
The current distribution in a HTS coil winding which uses a wide superconducting tape reflects the history of the current sourcing, the local inhomogeneity and especially the local distribution of the radial component of the magnetic field inside the winding. We measured the radial component of the magnetic field in a rectangular frame around the winding cross-section using a thin Hall probe. From the mapped data of radial component, the current distribution in the cross-section of the winding was determined using an inverse calculation relating the known mapped data and unknown distribution of the current's circumferential component in the coil. The Tikhonov method of regularization was applied in the calculation. The exact current distribution in the winding cross-section was approximated by a dense mesh of discrete points. The results are expressed for different coil currents during a gradual ramping up and down.
- 6 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 18 (2) , 1597-1600
Current Distribution in the Winding of a Superconducting Coil
The current distribution in a HTS coil winding which uses a wide superconducting tape reflects the history of the current sourcing, the local inhomogeneity and especially the local distribution of the radial component of the magnetic field inside the winding. We measured the radial component of the magnetic field in a rectangular frame around the winding cross-section using a thin Hall probe. From the mapped data of radial component, the current distribution in the cross-section of the winding was determined using an inverse calculation relating the known mapped data and unknown distribution of the current's circumferential component in the coil. The Tikhonov method of regularization was applied in the calculation. The exact current distribution in the winding cross-section was approximated by a dense mesh of discrete points. The results are expressed for different coil currents during a gradual ramping up and down.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 3148-3150
Low ac Loss Multifilament Coated Conductors
We report the magnetization losses in an experimental multifilament coated conductor. A 4 mm wide and 10 cm long YBCO coated conductor was subdivided into eight 0.5 mm wide filaments by laser ablation and subjected to post-ablation treatment. As the result, the hysteresis loss was reduced, as expected, in proportion to the width of the filaments. However, the coupling losses were reduced dramatically, and became practically negligible, in the range of a sweep rate up to 20 T/s. This represents a drastic improvement on previous multifilament conductors in which often the coupling losses became equal to the hysteresis loss at a sweep rate as low as 3-4 T/s. These results demonstrate that there is an effective and practical way to suppress coupling losses in coated multifilament conductors.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 3148-3150
Low ac Loss Multifilament Coated Conductors
We report the magnetization losses in an experimental multifilament coated conductor. A 4 mm wide and 10 cm long YBCO coated conductor was subdivided into eight 0.5 mm wide filaments by laser ablation and subjected to post-ablation treatment. As the result, the hysteresis loss was reduced, as expected, in proportion to the width of the filaments. However, the coupling losses were reduced dramatically, and became practically negligible, in the range of a sweep rate up to 20 T/s. This represents a drastic improvement on previous multifilament conductors in which often the coupling losses became equal to the hysteresis loss at a sweep rate as low as 3-4 T/s. These results demonstrate that there is an effective and practical way to suppress coupling losses in coated multifilament conductors.
- 3 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (1)
Multifilament YBa2Cu3O6+x-coated conductors with minimized coupling losses
We report an experimental approach to making multifilament coated conductors with low losses in applied time-varying magnetic field. Previously, the multifilament conductors obtained for that purpose by laser ablation suffered from high coupling losses. Here we report how this problem can be solved. When the substrate metal in the grooves segregating the filaments is exposed to oxygen, it forms high resistivity oxides that electrically insulate the stripes from each other and from the substrate. As the result, the coupling loss has become negligible over the entire range of tested parameters (magnetic field amplitudes and frequencies ).- 3 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (1)
Multifilament YBa2Cu3O6+x-coated conductors with minimized coupling losses
We report an experimental approach to making multifilament coated conductors with low losses in applied time-varying magnetic field. Previously, the multifilament conductors obtained for that purpose by laser ablation suffered from high coupling losses. Here we report how this problem can be solved. When the substrate metal in the grooves segregating the filaments is exposed to oxygen, it forms high resistivity oxides that electrically insulate the stripes from each other and from the substrate. As the result, the coupling loss has become negligible over the entire range of tested parameters (magnetic field amplitudes and frequencies ).- 10 February 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 86 (7) , 072509
Magnetization losses in multifilament coated superconductors
We report the results of a study of the magnetization losses in experimental multifilament, as well as control (uniform) coated superconductors exposed to time-varying magnetic fields of various frequencies. Both the hysteresis loss, proportional to the sweep rate of the applied magnetic field, and the coupling loss, proportional to the square of the sweep rate, have been observed. A scaling is found that allows us to quantify each of these contributions and extrapolate the results of the experiment beyond the envelope of accessible field amplitude and frequency. The combined loss in the multifilament conductor is reduced by about 90% in comparison with the uniform conductor at full field penetration at a sweep rate as high as 3 T/s.
- 10 February 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 86 (7) , 072509
Magnetization losses in multifilament coated superconductors
We report the results of a study of the magnetization losses in experimental multifilament, as well as control (uniform) coated superconductors exposed to time-varying magnetic fields of various frequencies. Both the hysteresis loss, proportional to the sweep rate of the applied magnetic field, and the coupling loss, proportional to the square of the sweep rate, have been observed. A scaling is found that allows us to quantify each of these contributions and extrapolate the results of the experiment beyond the envelope of accessible field amplitude and frequency. The combined loss in the multifilament conductor is reduced by about 90% in comparison with the uniform conductor at full field penetration at a sweep rate as high as 3 T/s.