Tobias Jungk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Jungk has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
E. Soergel
7 shared publicationsA. Hoffmann
Institute of Physics University of Bonn Wegelerstraße 8 53115 Bonn Germany
3 shared publicationsElisabeth Soergel
Institute of Physics University of Bonn Wegelerstraße 8 53115 Bonn Germany
3 shared publicationsÁ. Hoffmann
3 shared publicationsÁkos Hoffmann
University of Bonn Institute of Physics Wegelerstraße 8, 53115 Bonn, Germany
2 shared publicationsA. Hoffmann.
Institute of Physics University of Bonn Wegelerstraße 8 53115 Bonn Germany
1 shared publication
Latest Publications
- 23 June 2014
- Published by American Physical Society (APS) in Physical Review B
- Vol. 89 (22)
Comment on “Origin of piezoelectric response under a biased scanning probe microscopy tip across aferroelectric domain wall”In this Comment on the paper by S. Lei et al. [Phys. Rev. B 86, 134115 (2012)] we discuss in detail the quality and reliability of the experimental results the authors rely on for their statements. Indeed do we believe that the experimental data do not allow the conclusions drawn by the authors. In order to support our assessment we present our own newly recorded experimental data. Furthermore, we question the validity of the authors' finite element modeling, the outcome of which being, at least partially, contradictory to the experimental results.
- 23 June 2014
- Published by American Physical Society (APS) in Physical Review B
- Vol. 89 (22)
Comment on “Origin of piezoelectric response under a biased scanning probe microscopy tip across aferroelectric domain wall”In this Comment on the paper by S. Lei et al. [Phys. Rev. B 86, 134115 (2012)] we discuss in detail the quality and reliability of the experimental results the authors rely on for their statements. Indeed do we believe that the experimental data do not allow the conclusions drawn by the authors. In order to support our assessment we present our own newly recorded experimental data. Furthermore, we question the validity of the authors' finite element modeling, the outcome of which being, at least partially, contradictory to the experimental results.
- Open Access
Contrast Mechanisms for the Detection of Ferroelectric Domains with Scanning Force Microscopy
We present a full analysis of the contrast mechanisms for the detection of ferroelectric domains on all faces of bulk single crystals using scanning force microscopy exemplified on hexagonally poled lithium niobate. The domain contrast can be attributed to three different mechanisms: i) the thickness change of the sample due to an out-of-plane piezoelectric response (standard piezoresponse force microscopy), ii) the lateral displacement of the sample surface due to an in-plane piezoresponse, and iii) the electrostatic tip-sample interaction at the domain boundaries caused by surface charges on the crystallographic y- and z-faces. A careful analysis of the movement of the cantilever with respect to its orientation relative to the crystallographic axes of the sample allows a clear attribution of the observed domain contrast to the driving forces respectively.
Open AccessContrast Mechanisms for the Detection of Ferroelectric Domains with Scanning Force Microscopy
We present a full analysis of the contrast mechanisms for the detection of ferroelectric domains on all faces of bulk single crystals using scanning force microscopy exemplified on hexagonally poled lithium niobate. The domain contrast can be attributed to three different mechanisms: i) the thickness change of the sample due to an out-of-plane piezoelectric response (standard piezoresponse force microscopy), ii) the lateral displacement of the sample surface due to an in-plane piezoresponse, and iii) the electrostatic tip-sample interaction at the domain boundaries caused by surface charges on the crystallographic y- and z-faces. A careful analysis of the movement of the cantilever with respect to its orientation relative to the crystallographic axes of the sample allows a clear attribution of the observed domain contrast to the driving forces respectively.
- Open Access
Impact of elasticity on the piezoresponse of adjacent ferroelectric domains investigated by scanning force microscopy
As a consequence of elasticity, mechanical deformations of crystals occur on a length scale comparable to their thickness. This is exemplified by applying a homogeneous electric field to a multi-domain ferroelectric crystal: as one domain is expanding the adjacent ones are contracting, leading to clamping at the domain boundaries. The piezomechanically driven surface corrugation of micron-sized domain patterns in thick crystals using large-area top electrodes is thus drastically suppressed, barely accessible by means of piezoresponse force microscopy.
Open AccessImpact of elasticity on the piezoresponse of adjacent ferroelectric domains investigated by scanning force microscopy
As a consequence of elasticity, mechanical deformations of crystals occur on a length scale comparable to their thickness. This is exemplified by applying a homogeneous electric field to a multi-domain ferroelectric crystal: as one domain is expanding the adjacent ones are contracting, leading to clamping at the domain boundaries. The piezomechanically driven surface corrugation of micron-sized domain patterns in thick crystals using large-area top electrodes is thus drastically suppressed, barely accessible by means of piezoresponse force microscopy.
- 15 October 2007
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 102 (8) , 084102
Impact of elasticity on the piezoresponse of adjacent ferroelectric domains investigated by scanning force microscopy
As a consequence of elasticity, mechanical deformations of crystals occur on a length scale comparable to their thickness. This is exemplified by applying a homogeneous electric field to a multidomain ferroelectric crystal: As one domain is expanding, the adjacent ones are contracting, leading to clamping at the domain boundaries. The piezomechanically driven surface corrugation of micron-sized domain patterns in thick crystals using large-area top electrodes is thus drastically suppressed, barely accessible by means of piezoresponse force microscopy.
- 15 October 2007
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 102 (8) , 084102
Impact of elasticity on the piezoresponse of adjacent ferroelectric domains investigated by scanning force microscopy
As a consequence of elasticity, mechanical deformations of crystals occur on a length scale comparable to their thickness. This is exemplified by applying a homogeneous electric field to a multidomain ferroelectric crystal: As one domain is expanding, the adjacent ones are contracting, leading to clamping at the domain boundaries. The piezomechanically driven surface corrugation of micron-sized domain patterns in thick crystals using large-area top electrodes is thus drastically suppressed, barely accessible by means of piezoresponse force microscopy.
- 14 July 2007
- Published by Wiley in Journal of Microscopy
- Vol. 227 (1) , 72-78
Consequences of the background in piezoresponse force microscopy on the imaging of ferroelectric domain structures
Summary: The interpretation of ferroelectric domain images obtained with a piezoresponse force microscope (PFM) is discussed. The influence of an inherent experimental background on the domain contrast in PFM images (enhancement, nulling, inversion) as well as on the shape and the location of the domain boundaries are described. We present experimental results to evidence our analysis of the influence of the background on the domain contrast in PFM images.
- 14 July 2007
- Published by Wiley in Journal of Microscopy
- Vol. 227 (1) , 72-78
Consequences of the background in piezoresponse force microscopy on the imaging of ferroelectric domain structures
Summary: The interpretation of ferroelectric domain images obtained with a piezoresponse force microscope (PFM) is discussed. The influence of an inherent experimental background on the domain contrast in PFM images (enhancement, nulling, inversion) as well as on the shape and the location of the domain boundaries are described. We present experimental results to evidence our analysis of the influence of the background on the domain contrast in PFM images.
- Open Access
Consequences of the background in piezoresponse force microscopy on the imaging of ferroelectric domain structures
The interpretation of ferroelectric domain images obtained with piezoresponse force microscopy (PFM) is discussed. The influences of an inherent experimental background on the domain contrast in PFM images (enhancement, nulling, inversion) as well as on the shape and the location of the domain boundaries are described. We present experimental results to evidence our analysis of the influence of the background on the domain contrast in PFM images.
Open AccessConsequences of the background in piezoresponse force microscopy on the imaging of ferroelectric domain structures
The interpretation of ferroelectric domain images obtained with piezoresponse force microscopy (PFM) is discussed. The influences of an inherent experimental background on the domain contrast in PFM images (enhancement, nulling, inversion) as well as on the shape and the location of the domain boundaries are described. We present experimental results to evidence our analysis of the influence of the background on the domain contrast in PFM images.
- Open Access
Impact of the tip radius on the lateral resolution in piezoresponse force microscopy
We present a quantitative investigation of the impact of tip radius as well as sample type and thickness on the lateral resolution in piezoresponse force microscopy (PFM) investigating bulk single crystals. The observed linear dependence of the width of the domain wall on the tip radius as well as the independence of the lateral resolution on the specific crystal-type are validated by a simple theoretical model. Using a Ti-Pt-coated tip with a nominal radius of 15 nm the so far highest lateral resolution in bulk crystals of only 17 nm was obtained.
Open AccessImpact of the tip radius on the lateral resolution in piezoresponse force microscopy
We present a quantitative investigation of the impact of tip radius as well as sample type and thickness on the lateral resolution in piezoresponse force microscopy (PFM) investigating bulk single crystals. The observed linear dependence of the width of the domain wall on the tip radius as well as the independence of the lateral resolution on the specific crystal-type are validated by a simple theoretical model. Using a Ti-Pt-coated tip with a nominal radius of 15 nm the so far highest lateral resolution in bulk crystals of only 17 nm was obtained.
- Open Access
Limitations for the determination of piezoelectric constants with piezoresponse force microscopy
At first sight piezoresponse force microscopy (PFM) seems an ideal technique for the determination of piezoelectric coefficients (PCs), thus making use of its ultra-high vertical resolution (<0.1 pm/V). Christman et al. \cite{Chr98} first used PFM for this purpose. Their measurements, however, yielded only reasonable results of unsatisfactory accuracy, amongst others caused by an incorrect calibration of the setup. In this contribution a reliable calibration procedure is given followed by a careful analysis of the encounted difficulties determining PCs with PFM. We point out different approaches for their solution and expose why, without an extensive effort, those difficulties can not be circumvented.
Open AccessLimitations for the determination of piezoelectric constants with piezoresponse force microscopy
At first sight piezoresponse force microscopy (PFM) seems an ideal technique for the determination of piezoelectric coefficients (PCs), thus making use of its ultra-high vertical resolution (<0.1 pm/V). Christman et al. \cite{Chr98} first used PFM for this purpose. Their measurements, however, yielded only reasonable results of unsatisfactory accuracy, amongst others caused by an incorrect calibration of the setup. In this contribution a reliable calibration procedure is given followed by a careful analysis of the encounted difficulties determining PCs with PFM. We point out different approaches for their solution and expose why, without an extensive effort, those difficulties can not be circumvented.
- 8 December 2006
- Published by Springer Nature in Applied Physics A
- Vol. 86 (3) , 353-355
Influence of the inhomogeneous field at the tip on quantitative piezoresponse force microscopy
- 8 December 2006
- Published by Springer Nature in Applied Physics A
- Vol. 86 (3) , 353-355
Influence of the inhomogeneous field at the tip on quantitative piezoresponse force microscopy
- 24 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (4) , 042901
Detection mechanism for ferroelectric domain boundaries with lateral force microscopy
The contrast mechanism for the visualization of ferroelectric domain boundaries with lateral force microscopy is generally assumed to be caused by mechanical deformation of the sample due to the converse piezoelectric effect. We show, however, that electrostatic interactions between the charged tip and the electric fields arising from the surface polarization charges dominate the contrast mechanism. This explanation is sustained by quantitative analysis of the measured forces as well as by comparative measurements on lithium niobate and potassium titanyl phosphate.
- 24 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (4) , 042901
Detection mechanism for ferroelectric domain boundaries with lateral force microscopy
The contrast mechanism for the visualization of ferroelectric domain boundaries with lateral force microscopy is generally assumed to be caused by mechanical deformation of the sample due to the converse piezoelectric effect. We show, however, that electrostatic interactions between the charged tip and the electric fields arising from the surface polarization charges dominate the contrast mechanism. This explanation is sustained by quantitative analysis of the measured forces as well as by comparative measurements on lithium niobate and potassium titanyl phosphate.