Eisuke Tatsumi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eisuke Tatsumi has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
Yoshiyuki Taenaka
National Cerebral & Cardiovascular Center Research Institute Dept. of Artificial Organs
38 shared publicationsAkihiko Homma
Toin Yokohama University
20 shared publications- Kohji Koshiji
Tokyo University of Science
10 shared publications - Takahiko Yamamoto
Tokyo University of Science
10 shared publications Hisateru Takano
National Cardiovascular Center
9 shared publications- Tomonori Tsukiya
National Cardiovascular Center
9 shared publications
Latest Publications
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H01
Development of a portable pneumatic driver for ventricular assist devices
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1H01
Development of a portable pneumatic driver for ventricular assist devices
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 12 July 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (5) , 1488-1495
Novel Rotational Speed Modulation System Used With Venoarterial Extracorporeal Membrane Oxygenation
- 12 July 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (5) , 1488-1495
Novel Rotational Speed Modulation System Used With Venoarterial Extracorporeal Membrane Oxygenation
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2014, _S0220101-_S0220101-
S0220101 Development of Ventricular Assist Device for Patients with Small Body Weight
The axial flow blood pump was designed to be implanted in the thoracic cavity of the patients with sever heart failure to make a long-term left ventricular bypass. The developed axial flow pump consists of the hydrodynamic bearings that allow non-mechanical contacting levitation the impeller. The present study deals with the in vitro performance of the first prototype of the miniaturized device. The newly designed inlet port attached vertically to the pump body contributed to the downsizing of the pump in the axial dimension (from 121 to 81 mm) with a limited extent of losses in its hydrodynamic performance. The modified pump demonstrated the equivalent hydrodynamic performance to that of the adult device. The hemolytic properties with the new vane were within an acceptable range.
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2014, _S0220101-_S0220101-
S0220101 Development of Ventricular Assist Device for Patients with Small Body Weight
The axial flow blood pump was designed to be implanted in the thoracic cavity of the patients with sever heart failure to make a long-term left ventricular bypass. The developed axial flow pump consists of the hydrodynamic bearings that allow non-mechanical contacting levitation the impeller. The present study deals with the in vitro performance of the first prototype of the miniaturized device. The newly designed inlet port attached vertically to the pump body contributed to the downsizing of the pump in the axial dimension (from 121 to 81 mm) with a limited extent of losses in its hydrodynamic performance. The modified pump demonstrated the equivalent hydrodynamic performance to that of the adult device. The hemolytic properties with the new vane were within an acceptable range.
- 20 December 2012
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 16 (2) , 176-184
In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model
Using simple, safe, and economical in-body tissue engineering, autologous valved conduits (biovalves) with the sinus of Valsalva and without any artificial support materials were developed in animal recipients’ bodies. In this study, the feasibility of the biovalve as an aortic valve was evaluated in a goat model. Biovalves were prepared by 2-month embedding of the molds, assembled using two types of specially designed plastic rods, in the dorsal subcutaneous spaces of goats. One rod had three projections, resembling the protrusions of the sinus of Valsalva. Completely autologous connective tissue biovalves (type VI) with three leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds from both terminals of the harvested implants with complete encapsulation. The biovalve leaflets had appropriate strength and elastic characteristics similar to those of native aortic valves; thus, a robust conduit was formed. Tight valvular coaptation and a sufficient open orifice area were observed in vitro. Biovalves (n = 3) were implanted in the specially designed apico-aortic bypass for 2 months as a pilot study. Postoperative echocardiography showed smooth movement of the leaflets with little regurgitation under systemic circulation (2.6 ± 1.1 l/min). α-SMA–positive cells appeared significantly with rich angiogenesis in the conduit and expanded toward the leaflet tip. At the sinus portions, marked elastic fibers were formed. The luminal surface was covered with thin pseudointima without thrombus formation. Completely autologous biovalves with robust and elastic characteristics satisfied the higher requirements of the systemic circulation in goats for 2 months with the potential for valvular tissue regeneration.
- 20 December 2012
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 16 (2) , 176-184
In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model
Using simple, safe, and economical in-body tissue engineering, autologous valved conduits (biovalves) with the sinus of Valsalva and without any artificial support materials were developed in animal recipients’ bodies. In this study, the feasibility of the biovalve as an aortic valve was evaluated in a goat model. Biovalves were prepared by 2-month embedding of the molds, assembled using two types of specially designed plastic rods, in the dorsal subcutaneous spaces of goats. One rod had three projections, resembling the protrusions of the sinus of Valsalva. Completely autologous connective tissue biovalves (type VI) with three leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds from both terminals of the harvested implants with complete encapsulation. The biovalve leaflets had appropriate strength and elastic characteristics similar to those of native aortic valves; thus, a robust conduit was formed. Tight valvular coaptation and a sufficient open orifice area were observed in vitro. Biovalves (n = 3) were implanted in the specially designed apico-aortic bypass for 2 months as a pilot study. Postoperative echocardiography showed smooth movement of the leaflets with little regurgitation under systemic circulation (2.6 ± 1.1 l/min). α-SMA–positive cells appeared significantly with rich angiogenesis in the conduit and expanded toward the leaflet tip. At the sinus portions, marked elastic fibers were formed. The luminal surface was covered with thin pseudointima without thrombus formation. Completely autologous biovalves with robust and elastic characteristics satisfied the higher requirements of the systemic circulation in goats for 2 months with the potential for valvular tissue regeneration.
- 30 September 2012
- Published by Wiley in Artificial Organs
- Vol. 37 (2) , 136-141
Insufflation of Hydrogen Gas Restrains the Inflammatory Response of Cardiopulmonary Bypass in a Rat Model
Systemic inflammatory responses in patients receiving cardiac surgery with the use of the cardiopulmonary bypass (CPB) significantly contribute to CPB-associated morbidity and mortality. We hypothesized that insufflated hydrogen gas (H₂) would provide systemic anti-inflammatory and anti-apoptotic effects during CPB, therefore reducing proinflammatory cytokine levels. In this study, we examined the protective effect of H₂ on a rat CPB model. Rats were divided into three groups: the sham operation (SHAM) group, received sternotomy only; the CPB group, which was initiated and maintained for 60 min; and the CPB + H₂ group in which H₂ was given via an oxygenator during CPB for 60 min. We collected blood samples before, 20 min, and 60 min after the initiation of CPB. We measured the serum cytokine levels of (tumor necrosis factor-α, interleukin-6, and interleukin-10) and biochemical markers (lactate dehydrogenase, aspartate aminotransferase, and alanine aminotransferase). We also measured the wet-to-dry weight (W/D) ratio of the left lung 60 min after the initiation of CPB. In the CPB group, the cytokine and biochemical marker levels significantly increased 20 min after the CPB initiation and further increased 60 min after the CPB initiation as compared with the SHAM group. In the CPB + H₂ group, however, such increases were significantly suppressed at 60 min after the CPB initiation. Although the W/D ratio in the CPB group significantly increased as compared with that in the SHAM group, such an increase was also suppressed significantly in the CPB + H₂ group. We suggest that H₂ insufflation is a possible new potential therapy for counteracting CPB-induced systemic inflammation.
- 30 September 2012
- Published by Wiley in Artificial Organs
- Vol. 37 (2) , 136-141
Insufflation of Hydrogen Gas Restrains the Inflammatory Response of Cardiopulmonary Bypass in a Rat Model
Systemic inflammatory responses in patients receiving cardiac surgery with the use of the cardiopulmonary bypass (CPB) significantly contribute to CPB-associated morbidity and mortality. We hypothesized that insufflated hydrogen gas (H₂) would provide systemic anti-inflammatory and anti-apoptotic effects during CPB, therefore reducing proinflammatory cytokine levels. In this study, we examined the protective effect of H₂ on a rat CPB model. Rats were divided into three groups: the sham operation (SHAM) group, received sternotomy only; the CPB group, which was initiated and maintained for 60 min; and the CPB + H₂ group in which H₂ was given via an oxygenator during CPB for 60 min. We collected blood samples before, 20 min, and 60 min after the initiation of CPB. We measured the serum cytokine levels of (tumor necrosis factor-α, interleukin-6, and interleukin-10) and biochemical markers (lactate dehydrogenase, aspartate aminotransferase, and alanine aminotransferase). We also measured the wet-to-dry weight (W/D) ratio of the left lung 60 min after the initiation of CPB. In the CPB group, the cytokine and biochemical marker levels significantly increased 20 min after the CPB initiation and further increased 60 min after the CPB initiation as compared with the SHAM group. In the CPB + H₂ group, however, such increases were significantly suppressed at 60 min after the CPB initiation. Although the W/D ratio in the CPB group significantly increased as compared with that in the SHAM group, such an increase was also suppressed significantly in the CPB + H₂ group. We suggest that H₂ insufflation is a possible new potential therapy for counteracting CPB-induced systemic inflammation.
- Open Access
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _S021011-1
S021011 Durability Test of Continuous-flow Ventricular Assist Devices under Pulsatile Flow
The durability test for a newly developing axial-flow ventricular assist device (VAD) with hydrodynamic bearings was conducted under pulsatile flow condition for six months to obtain a long-term reliability. A mock circulation was consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance and simple-layout flow paths that were made of polymer or titanium. The VAD was installed behind the diaphragm pump submerged in saline solution. A blood analog fluid was saline added with glycerin whose viscosity coincided with that of blood at the temperature of 37 ℃. The pulsatile flow condition was set within the flow rate range to realize positive flow rate and positive head at the impeller rotational speed obtaining the flow rate of 5 L/min and the pressure of 100 mmHg. The pump characteristics were monitored for flow rate, pressure head, impeller rotational speed, and so on. The mock circulation characteristics were maintained for fluid temperature, fluid density and pulse rate of the diaphragm pump, and so on. The mock circulation realized the pulsatile flow rate to achieve 0±1 L/min at the systolic phase, 9.5±1 L/min at the diastolic phase and 5±1 L/min in average at the pulse rate of 72 bpm. The durability tests were conducted for eight axial-flow VADs. For six months, the experimental conditions have been maintained that were the average flow rate of 4.4 (± 0.2) ± 0.05 (± 0.04) L/min, the diastic flow rate of 0.1 (± 0.1) ± 0.1 (± 0.1) L/min, the systolic flow rate of 10.9 (± 0.2) ± 0.1 (± 0.03) L/min, the average head of 80 (± 3) ± 2 (± 2) mmHg, the pulse rate of 72.1 (± 0.3) ± 0.2 (± 0.1) bpm, the fluid temparature of 37.2 (± 0.2) ± 0.2(± 0.1)℃, the fluid viscosity of 3.2(±0.1)±0.3(±0.1) cP, in which the value in the bracket means individual device differences. The metal components were hardly detected in the working fluids. The long-term durability of the developing axial-flow VAD for six months was confirmed.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _S021011-1
Open AccessS021011 Durability Test of Continuous-flow Ventricular Assist Devices under Pulsatile Flow
The durability test for a newly developing axial-flow ventricular assist device (VAD) with hydrodynamic bearings was conducted under pulsatile flow condition for six months to obtain a long-term reliability. A mock circulation was consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance and simple-layout flow paths that were made of polymer or titanium. The VAD was installed behind the diaphragm pump submerged in saline solution. A blood analog fluid was saline added with glycerin whose viscosity coincided with that of blood at the temperature of 37 ℃. The pulsatile flow condition was set within the flow rate range to realize positive flow rate and positive head at the impeller rotational speed obtaining the flow rate of 5 L/min and the pressure of 100 mmHg. The pump characteristics were monitored for flow rate, pressure head, impeller rotational speed, and so on. The mock circulation characteristics were maintained for fluid temperature, fluid density and pulse rate of the diaphragm pump, and so on. The mock circulation realized the pulsatile flow rate to achieve 0±1 L/min at the systolic phase, 9.5±1 L/min at the diastolic phase and 5±1 L/min in average at the pulse rate of 72 bpm. The durability tests were conducted for eight axial-flow VADs. For six months, the experimental conditions have been maintained that were the average flow rate of 4.4 (± 0.2) ± 0.05 (± 0.04) L/min, the diastic flow rate of 0.1 (± 0.1) ± 0.1 (± 0.1) L/min, the systolic flow rate of 10.9 (± 0.2) ± 0.1 (± 0.03) L/min, the average head of 80 (± 3) ± 2 (± 2) mmHg, the pulse rate of 72.1 (± 0.3) ± 0.2 (± 0.1) bpm, the fluid temparature of 37.2 (± 0.2) ± 0.2(± 0.1)℃, the fluid viscosity of 3.2(±0.1)±0.3(±0.1) cP, in which the value in the bracket means individual device differences. The metal components were hardly detected in the working fluids. The long-term durability of the developing axial-flow VAD for six months was confirmed.
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Fluids engineering conference
- Vol. 2009, 359-360
1109 Development of a Centrifugal Pump with a Two-stage Impeller Designed for Cardiopulmonary Support System
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Fluids engineering conference
- Vol. 2009, 359-360
1109 Development of a Centrifugal Pump with a Two-stage Impeller Designed for Cardiopulmonary Support System
- 31 October 2008
- Published by Elsevier in Diamond and Related Materials
- Vol. 17 (7-10) , 1702-1705
Amorphous hydrogenated carbon (a-C:H) film coating on an inner-wall of cylindrical textile materials by r.f. plasma CVD
- 31 October 2008
- Published by Elsevier in Diamond and Related Materials
- Vol. 17 (7-10) , 1702-1705
Amorphous hydrogenated carbon (a-C:H) film coating on an inner-wall of cylindrical textile materials by r.f. plasma CVD
- 1 August 2008
- Vol. 62 (4) , 235-9
Experimental study of a novel method of cardiopulmonary resuscitation using a combination of percutaneous cardiopulmonary support and liposome-encapsulated hemoglobin (TRM645).
Percutaneous cardiopulmonary support (PCPS) has been applied for cardiopulmonary arrest (CPA). We have developed a novel method of cardiopulmonary resuscitation using PCPS combined with liposome-encapsulated hemoglobin (TRM645) to improve oxygen delivery to vital organs. Ventricular fibrillation was electrically induced to an adult goat for 10 min. Next, PCPS (30 ml/kg/min, V/Q: 1) was performed for 20 min. Then, external defibrillation was attempted and observed for 120 min. The TRM group (n5) was filled with 300 mL of TRM645 for the PCPS circuit. The control group (n5) was filled with the same volume of saline. The delivery of oxygen (DO2) and oxygen consumption (VO2) decreased markedly by PCPS after CPA, compared to the preoperative values. DO2 was kept at a constant level during PCPS in both groups, but VO2 slowly decreased at 5, 10, and 15 min of PCPS in the control groups, demonstrating that systemic oxygen metabolism decreased with time. In contrast, the decreases in VO2 were small in the TRM group at 5, 10, and 15 min of PCPS, demonstrating that TRM645 continuously maintained systemic oxygen consumption even at a low flow rate. AST and LDH in the TRM group were lower than the control. There were significant differences at 120 min after the restoration of spontaneous circulation (p<0.05).
- 1 August 2008
- Vol. 62 (4) , 235-9
Experimental study of a novel method of cardiopulmonary resuscitation using a combination of percutaneous cardiopulmonary support and liposome-encapsulated hemoglobin (TRM645).
Percutaneous cardiopulmonary support (PCPS) has been applied for cardiopulmonary arrest (CPA). We have developed a novel method of cardiopulmonary resuscitation using PCPS combined with liposome-encapsulated hemoglobin (TRM645) to improve oxygen delivery to vital organs. Ventricular fibrillation was electrically induced to an adult goat for 10 min. Next, PCPS (30 ml/kg/min, V/Q: 1) was performed for 20 min. Then, external defibrillation was attempted and observed for 120 min. The TRM group (n5) was filled with 300 mL of TRM645 for the PCPS circuit. The control group (n5) was filled with the same volume of saline. The delivery of oxygen (DO2) and oxygen consumption (VO2) decreased markedly by PCPS after CPA, compared to the preoperative values. DO2 was kept at a constant level during PCPS in both groups, but VO2 slowly decreased at 5, 10, and 15 min of PCPS in the control groups, demonstrating that systemic oxygen metabolism decreased with time. In contrast, the decreases in VO2 were small in the TRM group at 5, 10, and 15 min of PCPS, demonstrating that TRM645 continuously maintained systemic oxygen consumption even at a low flow rate. AST and LDH in the TRM group were lower than the control. There were significant differences at 120 min after the restoration of spontaneous circulation (p<0.05).