A. Tomioka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
A. Tomioka has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
H. Hayashi
Kyushu Electric Power Co., Inc., Fukuoka, Japan
7 shared publicationsH. Okamoto
Kyushu Electric Power Co., Inc., Fukuoka, Japan
5 shared publicationsY. Gosho
Kyushu Electric Power Co., Inc., Fukuoka, Japan
5 shared publicationsM. Konno
Fuji Electric Co., Ltd., Chiba, Japan
4 shared publicationsT. Izumi
International Superconductivity Technology Center, Tokyo, Japan
4 shared publicationsK. Tanabe
International Superconductivity Technology Center, 10-13, Shinonome 1-chome, Koto-ku, Tokyo 135-0062, Japan
3 shared publications
Latest Publications
- 11 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 5500104
Development of REBCO Superconducting Transformers With a Current Limiting Function
We designed and fabricated a 10 kVA single-phase transformer with RE 1 Ba 2 Cu 3 O 7-δ (REBCO, RE:Rare Earth, Y, Gd, etc.) superconducting tapes. It had a 4-winding structure at the beginning. In this study, we removed the auxiliary windings and made a test as a general 2-winding transformer. Making repeated short circuit tests, we further investigated the response of the REBCO superconducting windings against a fault excess current. Although the short circuit current decayed satisfactorily, the whole of the REBCO superconducting windings did not shift to normal state even if the short circuit current exceeded the critical current all over the length of REBCO tapes. The induced normal resistance depended on the primary voltage. To study the phenomena, we derived the basic equations and made numerical simulations taking into account of flux-flow state, in which the equivalent resistance and generated heat are much smaller than those in normal state, and also the dependences of the critical current on temperature, applied magnetic field and the applied field angle to the tape face. It was clarified that short circuit current was limited not only by normal resistance but also by flux-flow one. The introduction of the concept of flux-flow state made it possible to quantitatively explain the behavior of the REBCO superconducting transformer at a sudden short circuit.
- 11 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 5500104
Development of REBCO Superconducting Transformers With a Current Limiting Function
We designed and fabricated a 10 kVA single-phase transformer with RE 1 Ba 2 Cu 3 O 7-δ (REBCO, RE:Rare Earth, Y, Gd, etc.) superconducting tapes. It had a 4-winding structure at the beginning. In this study, we removed the auxiliary windings and made a test as a general 2-winding transformer. Making repeated short circuit tests, we further investigated the response of the REBCO superconducting windings against a fault excess current. Although the short circuit current decayed satisfactorily, the whole of the REBCO superconducting windings did not shift to normal state even if the short circuit current exceeded the critical current all over the length of REBCO tapes. The induced normal resistance depended on the primary voltage. To study the phenomena, we derived the basic equations and made numerical simulations taking into account of flux-flow state, in which the equivalent resistance and generated heat are much smaller than those in normal state, and also the dependences of the critical current on temperature, applied magnetic field and the applied field angle to the tape face. It was clarified that short circuit current was limited not only by normal resistance but also by flux-flow one. The introduction of the concept of flux-flow state made it possible to quantitatively explain the behavior of the REBCO superconducting transformer at a sudden short circuit.
- 3 March 2012
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 484, 239-241
The short-circuit test results of 6.9kV/2.3kV 400kVA-class YBCO model transformer with fault current limiting function
- 3 March 2012
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 484, 239-241
The short-circuit test results of 6.9kV/2.3kV 400kVA-class YBCO model transformer with fault current limiting function
- 30 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1367-1373
AC over-current test results of YBCO conductor for YBCO power transformer with fault current limiting function
- 30 November 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1367-1373
AC over-current test results of YBCO conductor for YBCO power transformer with fault current limiting function
- 14 May 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1374-1378
The short-circuit test results of 6.9kV/2.3kV 400kVA-class YBCO model transformer
- 14 May 2011
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 471 (21-22) , 1374-1378
The short-circuit test results of 6.9kV/2.3kV 400kVA-class YBCO model transformer
- 11 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1405-1408
Development of a REBCO Superconducting Transformer With Current Limiting Function
A single-phase 10 kVA transformer was designed and fabricated with RE1Ba2Cu30O7-δ (REBCO, RE: Rare Earth) superconducting tapes to quantitatively investigate the transition phenomenon of REBCO superconducting tapes to normal state due to a fault excess current. The voltage ratio was 1:1 and the rated voltage was 393 V. It had four windings. The primary and secondary windings had auxiliary windings in addition to main ones respectively. The main and auxiliary windings were connected in parallel in the both sides. The addition of the auxiliary windings made it possible to observe the induced normal resistances in the respective main ones individually. First usual performance tests were carried out and a stable operation as designed was confirmed. In steady state almost all of the current flowed in the main windings due to the small leakage reactance between them. At a sudden short-circuit test, the main windings quenched due to excess current over the critical current and the current was reduced to one fortieth as compared with the case of no current limiting function. It was clarified the whole of the main windings did not shift to normal state though the current exceeded the critical current all over the length and the induced normal zone was almost proportional to the primary voltage.
- 11 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1405-1408
Development of a REBCO Superconducting Transformer With Current Limiting Function
A single-phase 10 kVA transformer was designed and fabricated with RE1Ba2Cu30O7-δ (REBCO, RE: Rare Earth) superconducting tapes to quantitatively investigate the transition phenomenon of REBCO superconducting tapes to normal state due to a fault excess current. The voltage ratio was 1:1 and the rated voltage was 393 V. It had four windings. The primary and secondary windings had auxiliary windings in addition to main ones respectively. The main and auxiliary windings were connected in parallel in the both sides. The addition of the auxiliary windings made it possible to observe the induced normal resistances in the respective main ones individually. First usual performance tests were carried out and a stable operation as designed was confirmed. In steady state almost all of the current flowed in the main windings due to the small leakage reactance between them. At a sudden short-circuit test, the main windings quenched due to excess current over the critical current and the current was reduced to one fortieth as compared with the case of no current limiting function. It was clarified the whole of the main windings did not shift to normal state though the current exceeded the critical current all over the length and the induced normal zone was almost proportional to the primary voltage.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1927-1930
Tests of Superconducting Traction Transformer for Railway Rolling Stock
We have been developing a lightweight and high-efficiency superconducting traction transformer for railway rolling stock. We designed and fabricated a prototype superconducting traction transformer of a floor-mount type for Shinkansen rolling stock. In this study, we present test results such as type test, system test and vibration test. We performed the type test in accordance with JIS, E5007. In this test, we measured the basic electrical characteristics. In the system test, we tested the transformer with a dynamic simulator for rolling stock, as a converter connected at secondary winding, and verified the operating characteristics. We performed vibration tests in accordance with JIS, E4031, vibrating the transformer on a shaking table with three-dimensional movement. As a result, we could verify that the transformer satisfied the requirement almost exactly as initially planned.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1927-1930
Tests of Superconducting Traction Transformer for Railway Rolling Stock
We have been developing a lightweight and high-efficiency superconducting traction transformer for railway rolling stock. We designed and fabricated a prototype superconducting traction transformer of a floor-mount type for Shinkansen rolling stock. In this study, we present test results such as type test, system test and vibration test. We performed the type test in accordance with JIS, E5007. In this test, we measured the basic electrical characteristics. In the system test, we tested the transformer with a dynamic simulator for rolling stock, as a converter connected at secondary winding, and verified the operating characteristics. We performed vibration tests in accordance with JIS, E4031, vibrating the transformer on a shaking table with three-dimensional movement. As a result, we could verify that the transformer satisfied the requirement almost exactly as initially planned.
- 1 June 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 7 (2) , 684-687
Development of HTS current leads for 1 kWh/1 MW module type SMES system. I. Design study
- 1 June 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 7 (2) , 684-687
Development of HTS current leads for 1 kWh/1 MW module type SMES system. I. Design study