Mahmoud El Ghazaly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud El Ghazaly has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Talal A. Al-Thomali
2 shared publicationsA. A. Alzahrani
College of Medicine , Taif University , 888 , Taif , Saudi Arabia
1 shared publicationAbdulkadir Aydarous
1 shared publication- Antoaneta Ene
INPOLDE Research Center, Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, Dunarea de Jos University of Galati, 47 Domneasca Street, 800008 Galati, Romania
1 shared publication E. I. Khalil
Zagazig University
1 shared publication- Gharam A. Alharshan
Physics Department, College of Science, Princess Nourah Bint, Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 1 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 8124
An In-Depth Examination of the Natural Radiation and Radioactive Dangers Associated with Regularly Used Medicinal Herbs
The specific activity of U-238 and Th-232, as well as K-40 radionuclides, in twenty-nine investigated medicinal herbs used in Egypt has been measured using a high-purity germanium (HP Ge) detector. The measured values ranged from the BDL to 20.71 ± 1.52 with a mean of 7.25 ± 0.54 (Bq kg−1) for uranium-238, from the BDL to 29.35 ± 1.33 with a mean of 7.78 ± 0.633 (Bq kg−1) for thorium-232, and from 172 ± 5.85 to 1181.2 ± 25.5 with a mean of 471.4 ± 11.33 (Bq kg−1) for potassium-40. Individual herbs with the highest activity levels were found to be 20.71 ± 1.52 (Bq kg−1) for uranium-238 (H4, Thyme herb), 29.35 ± 1.33 (Bq kg−1) for thorium-232 (H20, Cinnamon), and 1181.2 ± 25.5 (Bq kg−1) for potassium-40 (H24, Worm-wood). (AACED) Ingestion-related effective doses over the course of a year of uranium-238 and thorium-232, as well as potassium-40 estimated from measured activity concentrations, are 0.002304 ± 0.00009 (minimum), 0.50869 ± 0.0002 (maximum), and 0.0373 ± 0.0004 (average)(mSv/yr). Radium equivalent activity (Raeq), annual gonadal dose equivalent (AGDE), absorbed gamma dose rate (Doutdoor, Dindoor), gamma representative level index (I), annual effective dose (AEDtotal), external and internal hazard index (Hex, Hin), and excess lifetime cancer risk were determined in medicinal plants (ELCR). The radiological hazards assessment revealed that the investigated plant species have natural radioactivity levels that are well within the internationally recommended limit. This is the first time that the natural radioactivity of therapeutic plants has been measured in Egypt. In addition, no artificial radionuclide (for example, 137Cs) was discovered in any of the samples. Therefore, the current findings are intended to serve as the foundation for establishing a standard safety and guideline for using these therapeutic plants in Egypt.
- 1 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 8124
Open AccessAn In-Depth Examination of the Natural Radiation and Radioactive Dangers Associated with Regularly Used Medicinal Herbs
The specific activity of U-238 and Th-232, as well as K-40 radionuclides, in twenty-nine investigated medicinal herbs used in Egypt has been measured using a high-purity germanium (HP Ge) detector. The measured values ranged from the BDL to 20.71 ± 1.52 with a mean of 7.25 ± 0.54 (Bq kg−1) for uranium-238, from the BDL to 29.35 ± 1.33 with a mean of 7.78 ± 0.633 (Bq kg−1) for thorium-232, and from 172 ± 5.85 to 1181.2 ± 25.5 with a mean of 471.4 ± 11.33 (Bq kg−1) for potassium-40. Individual herbs with the highest activity levels were found to be 20.71 ± 1.52 (Bq kg−1) for uranium-238 (H4, Thyme herb), 29.35 ± 1.33 (Bq kg−1) for thorium-232 (H20, Cinnamon), and 1181.2 ± 25.5 (Bq kg−1) for potassium-40 (H24, Worm-wood). (AACED) Ingestion-related effective doses over the course of a year of uranium-238 and thorium-232, as well as potassium-40 estimated from measured activity concentrations, are 0.002304 ± 0.00009 (minimum), 0.50869 ± 0.0002 (maximum), and 0.0373 ± 0.0004 (average)(mSv/yr). Radium equivalent activity (Raeq), annual gonadal dose equivalent (AGDE), absorbed gamma dose rate (Doutdoor, Dindoor), gamma representative level index (I), annual effective dose (AEDtotal), external and internal hazard index (Hex, Hin), and excess lifetime cancer risk were determined in medicinal plants (ELCR). The radiological hazards assessment revealed that the investigated plant species have natural radioactivity levels that are well within the internationally recommended limit. This is the first time that the natural radioactivity of therapeutic plants has been measured in Egypt. In addition, no artificial radionuclide (for example, 137Cs) was discovered in any of the samples. Therefore, the current findings are intended to serve as the foundation for establishing a standard safety and guideline for using these therapeutic plants in Egypt.
- 1 September 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 138, 81-86
Characterization of Makrofol®DE 1-1 for alpha particle radiography
- 1 September 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 138, 81-86
Characterization of Makrofol®DE 1-1 for alpha particle radiography
- 1 April 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 168 (4) , 316-321
Characterization of photoluminescence spectra from poly allyl diglycol carbonate (CR-39) upon excitation with the ultraviolet radiation of various wavelengths
The induced photoluminescence (PL) from the π-conjugated polymer poly allyl diglycol carbonate (PADC) (CR-39) upon excitation with the ultraviolet radiation of different wavelengths was investigated. The absorption and attenuation coefficients of PADC (CR-39) were recorded using a UV–visible spectrometer. It was found that the absorption and attenuation coefficients of the PADC (CR-39) exhibit a strong dependence on the wavelength of ultraviolet radiation. The PL spectra were measured with a Flormax-4 spectrofluorometer (Horiba). PADC (CR-39) samples were excited by ultraviolet radiation with wavelengths in the range from 260 to 420 nm and the corresponding PL emission bands were recorded. The obtained results show a strong correlation between the PL and the excitation wavelength of ultraviolet radiation. The position of the fluorescence emission band peak was red shifted starting from 300 nm, which was increased with the increase in the excitation wavelength. The PL yield and its band peak height were increased with the increase in the excitation wavelength till 290 nm, thereafter they decreased exponentially with the increase in the ultraviolet radiation wavelength. These new findings should be considered carefully during the use of the PADC (CR-39) in the scientific applications and in using PADC (CR-39) in eyeglasses.
- 1 April 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 168 (4) , 316-321
Characterization of photoluminescence spectra from poly allyl diglycol carbonate (CR-39) upon excitation with the ultraviolet radiation of various wavelengths
The induced photoluminescence (PL) from the π-conjugated polymer poly allyl diglycol carbonate (PADC) (CR-39) upon excitation with the ultraviolet radiation of different wavelengths was investigated. The absorption and attenuation coefficients of PADC (CR-39) were recorded using a UV–visible spectrometer. It was found that the absorption and attenuation coefficients of the PADC (CR-39) exhibit a strong dependence on the wavelength of ultraviolet radiation. The PL spectra were measured with a Flormax-4 spectrofluorometer (Horiba). PADC (CR-39) samples were excited by ultraviolet radiation with wavelengths in the range from 260 to 420 nm and the corresponding PL emission bands were recorded. The obtained results show a strong correlation between the PL and the excitation wavelength of ultraviolet radiation. The position of the fluorescence emission band peak was red shifted starting from 300 nm, which was increased with the increase in the excitation wavelength. The PL yield and its band peak height were increased with the increase in the excitation wavelength till 290 nm, thereafter they decreased exponentially with the increase in the ultraviolet radiation wavelength. These new findings should be considered carefully during the use of the PADC (CR-39) in the scientific applications and in using PADC (CR-39) in eyeglasses.
- 1 February 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 168 (2) , 137-145
Correlation between photoluminescence and optical properties of Makrofol®De 1-1 exposed to high flux of UVC
The correlation between the induced modifications in the photoluminescence spectra and the optical energy band gaps upon exposure to short ultraviolet C (UVC) of 254 nm in the polymers-based solid state nuclear track detector Makrofol® De 1-1 were investigated. Samples of Makrofol® De 1-1 were exposed to UVC radiation of 254 nm for different durations in air, thereafter the UV–visible and photoluminescence spectra were measured. It was found that Makrofol®-De 1-1 shows substantial's modifications in its optical and fluorescence characteristics upon exposure to UVC with a wavelength of 254 nm. UV–visible spectra of UVC irradiated Makrofol® De 1-1 shows continues red shift. Furthermore, a shoulder was observed in the wavelength range from 300 to 330 nm. Both of the red shift and the absorbance at the shoulder increase with the increase in the exposure time which seems to be saturated at prolonged exposure times more than 180 min. Photoluminescence spectra of UVC irradiated Makrofol® De 1-1 show a reasonable modifications upon exposure to UVC with a wavelength of 254 nm. The width at the half height of the band peak and the red shift of the photoluminescence spectra increase with the increase in the exposure time till the exposure time of 180 min, thereafter no significant changes were observed. It is found that the red shift and width of the photoluminescence spectra are correlated with the optical energy band gaps upon UVC irradiation. The peak wavelength as well as the band width of the photoluminescence spectra increases with the decrease in the optical band gaps. This experiment can provide an integrated understanding of utilizing Makrofol® De 1-1 in low linear energy transfer radiation dosimetry by connecting the concepts of photoluminescence, optical band gaps, and carbon clusters.
- 1 February 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 168 (2) , 137-145
Correlation between photoluminescence and optical properties of Makrofol®De 1-1 exposed to high flux of UVC
The correlation between the induced modifications in the photoluminescence spectra and the optical energy band gaps upon exposure to short ultraviolet C (UVC) of 254 nm in the polymers-based solid state nuclear track detector Makrofol® De 1-1 were investigated. Samples of Makrofol® De 1-1 were exposed to UVC radiation of 254 nm for different durations in air, thereafter the UV–visible and photoluminescence spectra were measured. It was found that Makrofol®-De 1-1 shows substantial's modifications in its optical and fluorescence characteristics upon exposure to UVC with a wavelength of 254 nm. UV–visible spectra of UVC irradiated Makrofol® De 1-1 shows continues red shift. Furthermore, a shoulder was observed in the wavelength range from 300 to 330 nm. Both of the red shift and the absorbance at the shoulder increase with the increase in the exposure time which seems to be saturated at prolonged exposure times more than 180 min. Photoluminescence spectra of UVC irradiated Makrofol® De 1-1 show a reasonable modifications upon exposure to UVC with a wavelength of 254 nm. The width at the half height of the band peak and the red shift of the photoluminescence spectra increase with the increase in the exposure time till the exposure time of 180 min, thereafter no significant changes were observed. It is found that the red shift and width of the photoluminescence spectra are correlated with the optical energy band gaps upon UVC irradiation. The peak wavelength as well as the band width of the photoluminescence spectra increases with the decrease in the optical band gaps. This experiment can provide an integrated understanding of utilizing Makrofol® De 1-1 in low linear energy transfer radiation dosimetry by connecting the concepts of photoluminescence, optical band gaps, and carbon clusters.
- 23 January 2013
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 62 (1) , 73-78
On the correlation between the photoluminescence and the optical properties of a thermally-annealed CR-39 polymer-based solid-state nuclear track detector
The induced modifications in the photoluminescence spectra and the optical properties, as well as the correlation between them, of CR-39 polymer-based solid-state nuclear track detectors were investigated after thermal annealing. CR-39 samples were thermally annealed for two hours at different temperatures higher than the glass transition temperature. A linear relationship between the relative mass loss of the CR-39 detector and the annealing temperature was found. The photoluminescence intensity of the pristine CR-39 detector was studied at different excitation wavelengths, where an isosbestic point was observed at 350 nm, which was used as an excitation wavelength. The photoluminescence increased with increasing annealing temperature until temperatures of 200 °C; thereafter, it decreased at temperatures of 220 and 250 °C. Moreover, the wavelength of the photoluminescence emission band was subjected to a red shift that increased with increasing annealing temperature. The optical band gaps, direct and indirect band gaps, were obtained from the optical absorption spectra by using a UV-visible spectrophotometer. The direct and indirect band gaps were found to decrease with increasing annealing temperature. A correlation between the photoluminescence peak wavelength and the optical band gaps was found. The spectral peaks red shifted as both of the optical band gaps decreased. We concluded that the reduction in the optical band gaps for both the direct and the indirect band gaps caused the red shift in the photoluminescence peak of the CR-39 detector.
- 23 January 2013
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 62 (1) , 73-78
On the correlation between the photoluminescence and the optical properties of a thermally-annealed CR-39 polymer-based solid-state nuclear track detector
The induced modifications in the photoluminescence spectra and the optical properties, as well as the correlation between them, of CR-39 polymer-based solid-state nuclear track detectors were investigated after thermal annealing. CR-39 samples were thermally annealed for two hours at different temperatures higher than the glass transition temperature. A linear relationship between the relative mass loss of the CR-39 detector and the annealing temperature was found. The photoluminescence intensity of the pristine CR-39 detector was studied at different excitation wavelengths, where an isosbestic point was observed at 350 nm, which was used as an excitation wavelength. The photoluminescence increased with increasing annealing temperature until temperatures of 200 °C; thereafter, it decreased at temperatures of 220 and 250 °C. Moreover, the wavelength of the photoluminescence emission band was subjected to a red shift that increased with increasing annealing temperature. The optical band gaps, direct and indirect band gaps, were obtained from the optical absorption spectra by using a UV-visible spectrophotometer. The direct and indirect band gaps were found to decrease with increasing annealing temperature. A correlation between the photoluminescence peak wavelength and the optical band gaps was found. The spectral peaks red shifted as both of the optical band gaps decreased. We concluded that the reduction in the optical band gaps for both the direct and the indirect band gaps caused the red shift in the photoluminescence peak of the CR-39 detector.
- 10 August 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 61 (3) , 336-341
Comparison between different models for alpha-particle range determination and a new approach to CR-39 detector
- 10 August 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 61 (3) , 336-341
Comparison between different models for alpha-particle range determination and a new approach to CR-39 detector
- 14 April 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 60 (7) , 1043-1048
Study of the optical properties and the carbonaceous clusters in thermally-annealed CR-39 and Makrofol-E polymer-based solid-state nuclear track detectors
- 14 April 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 60 (7) , 1043-1048
Study of the optical properties and the carbonaceous clusters in thermally-annealed CR-39 and Makrofol-E polymer-based solid-state nuclear track detectors
- 13 April 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (6) , 421-427
On alpha particle spectroscopy based on the over-etched track length in PADC (CR-39 detector)
In the current work, alpha particle spectroscopy is investigated experimentally by utilizing the over-etched track lengths in the CR-39 detector. CR-39 samples were exposed perpendicularly to alpha particles emitted from 241Am with an energy ranging from 0.5 to 5.5 MeV. CR-39 samples were etched in 6.25 N NaOH at (70±0.5)°C for different durations. The track diameter and track length were measured under an optical microscope. The results show that, the energy-over-etched track length calibration curve is monotonic, in other words, the over-etched track length is a monotonic function in alpha particle energy. On the other hand, the energy-diameter calibration curve is degenerated, i.e. alpha track diameter is non-monotonic function in alpha particle energy. These results suggest that the CR-39 detector could be used as a wide range alpha particles spectrometer using an energy-over-etched track length calibration curve.
- 13 April 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (6) , 421-427
On alpha particle spectroscopy based on the over-etched track length in PADC (CR-39 detector)
In the current work, alpha particle spectroscopy is investigated experimentally by utilizing the over-etched track lengths in the CR-39 detector. CR-39 samples were exposed perpendicularly to alpha particles emitted from 241Am with an energy ranging from 0.5 to 5.5 MeV. CR-39 samples were etched in 6.25 N NaOH at (70±0.5)°C for different durations. The track diameter and track length were measured under an optical microscope. The results show that, the energy-over-etched track length calibration curve is monotonic, in other words, the over-etched track length is a monotonic function in alpha particle energy. On the other hand, the energy-diameter calibration curve is degenerated, i.e. alpha track diameter is non-monotonic function in alpha particle energy. These results suggest that the CR-39 detector could be used as a wide range alpha particles spectrometer using an energy-over-etched track length calibration curve.
- 1 February 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (2) , 141-148
Modifications of the optical properties in Makrofol-E SSNTD exposed to ultraviolet radiation of different wavelengths
The induced modifications of the optical properties in UV-irradiated Makrofol-E with different wavelengths were investigated. Makrofol-E samples were irradiated by UV of wavelengths 254, 302, and 365 nm for different durations. It was found that Makrofol-E shows substantial modifications in its optical characteristics upon exposure to UV of wavelengths 302 and 254 nm, but no modifications were observed at 365 nm. UV-irradiated Makrofol-E with wavelengths 254 and 302 nm exhibits shoulder bands at 297 nm in UV–visible spectra. For an exposure time less than 20 h, the band absorbance strengths depend on the exposure time and approximately increases linearly, but for prolonged exposure times, the band absorbance strengths become almost saturated. The optical energy band gaps obtained from the direct and indirect allowed transition in K-space. Both of them decrease with the increase in exposure time for wavelengths of 254 and 302 nm. Urbach's energy increases with increase in the exposure time for both wavelengths of 254 and 302 nm. The number of carbon atoms in a cluster increases with the increase in the exposure time.
- 1 February 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (2) , 141-148
Modifications of the optical properties in Makrofol-E SSNTD exposed to ultraviolet radiation of different wavelengths
The induced modifications of the optical properties in UV-irradiated Makrofol-E with different wavelengths were investigated. Makrofol-E samples were irradiated by UV of wavelengths 254, 302, and 365 nm for different durations. It was found that Makrofol-E shows substantial modifications in its optical characteristics upon exposure to UV of wavelengths 302 and 254 nm, but no modifications were observed at 365 nm. UV-irradiated Makrofol-E with wavelengths 254 and 302 nm exhibits shoulder bands at 297 nm in UV–visible spectra. For an exposure time less than 20 h, the band absorbance strengths depend on the exposure time and approximately increases linearly, but for prolonged exposure times, the band absorbance strengths become almost saturated. The optical energy band gaps obtained from the direct and indirect allowed transition in K-space. Both of them decrease with the increase in exposure time for wavelengths of 254 and 302 nm. Urbach's energy increases with increase in the exposure time for both wavelengths of 254 and 302 nm. The number of carbon atoms in a cluster increases with the increase in the exposure time.