Georgios Sakas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Georgios Sakas has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Evelyn Firle
Fraunhofer Institut Graphische Datenverarbeitung
2 shared publications - Stefan Walter
Medcom GmbH (Germany)
2 shared publications Boris P. Selby
Medcom GmbH (Germany)
1 shared publication- Christian Dold
Department of Cognitive Computing and Medical Imaging, Fraunhofer Gesellschaft, Institute for Computer Graphics, Fraunhoferstr 5, D-64283 Darmstadt, Germany
1 shared publication - Dimos Baltas
Strahlenklinik, Klinikum Offenbach
1 shared publication Dold Christian
Fraunhofer Institute for Computer Graphics, Darmstadt, Germany
1 shared publication
Latest Publications
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6914, 69142U-69142
Reconstruction and registration of multispectral x-ray images for reliable alignment correction in radiation treatment devices
To align patients in radiation devices in six degrees of freedom (DoF), image-guided approaches perform the task of correction computation for the patient position. Digital radiography (DR) images are compared to projections of a CT series to estimate misalignments. A problem is that digital reconstructed radiographs (DRRs) have to be created from the CT to be registered with the DRs. Depending on the X-ray tube energy, detector sensitivity and body part involved, DRRs and DRs may look very different and often cannot be registered. We present a method that reconstructs multi-spectral DRRs for different X-ray settings, which can be registered to real X-ray images. As short rendering times are crucial, multiple spectra of a DRR are generated in one ray-tracing process. We register our multi-spectral DRR with the DR and add a further DoF to find a best match not only for the translations and in-plane rotation, but also the best fitting spectral planes. The results are used to identify patient misalignments and show that higher reliability can be achieved compared to conventional approaches. Misalignments can be identified even if ineligible X-ray settings have been used. As our approach allows application of lower X-ray energies for DR creation, an additional benefit is the reduction of the delivered dose.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6914, 69142U-69142
Reconstruction and registration of multispectral x-ray images for reliable alignment correction in radiation treatment devices
To align patients in radiation devices in six degrees of freedom (DoF), image-guided approaches perform the task of correction computation for the patient position. Digital radiography (DR) images are compared to projections of a CT series to estimate misalignments. A problem is that digital reconstructed radiographs (DRRs) have to be created from the CT to be registered with the DRs. Depending on the X-ray tube energy, detector sensitivity and body part involved, DRRs and DRs may look very different and often cannot be registered. We present a method that reconstructs multi-spectral DRRs for different X-ray settings, which can be registered to real X-ray images. As short rendering times are crucial, multiple spectra of a DRR are generated in one ray-tracing process. We register our multi-spectral DRR with the DR and add a further DoF to find a best match not only for the translations and in-plane rotation, but also the best fitting spectral planes. The results are used to identify patient misalignments and show that higher reliability can be achieved compared to conventional approaches. Misalignments can be identified even if ineligible X-ray settings have been used. As our approach allows application of lower X-ray energies for DR creation, an additional benefit is the reduction of the delivered dose.
- 4 January 2007
- Published by Springer Nature
- p. 445-459
Mobile Tele-Echography Systems — Teleinvivo: A Case Study
- 4 January 2007
- Published by Springer Nature
- p. 445-459
Mobile Tele-Echography Systems — Teleinvivo: A Case Study
- 30 September 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (9) , 1093-1103
Advantages and Limitations of Prospective Head Motion Compensation for MRI Using an Optical Motion Tracking Device
- 30 September 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (9) , 1093-1103
Advantages and Limitations of Prospective Head Motion Compensation for MRI Using an Optical Motion Tracking Device
- 1 January 2004
- Vol. 98, 75-81
The compensation of head motion artifacts using an infrared tracking system and a new algorithm for fMRI.
We aim to provide a next generation Magnetic Resonance Imaging (MRI) technology with an integrated solution for reducing motion artifacts in brain imaging applications. New developments in the field of MRI are revolutionizing the diagnostic capabilities e.g. of functional (fMRI) of the technique. Unfortunately, motion artifacts are eminent problems in cerebral MRI images, especially in difficult patient populations (e.g. chronic pain, children, neonates). Patient motion artifacts are present in 2D sequences, but are extremely detrimental in multi-slice 3D sequences often employed in fMRI. The problem of motion compensation in MRI technology deals with: Identification of the source as well as pattern of motion. Obtaining a mathematical model of motion that can be used to identify and then compensate the motion effects. Optimizing the image acquisition sequence in order to minimize, or even eliminate, the effect of motion. We propose a method to obtain a quantitative measure of the movement of the head between different data acquisition points in both MRI, and functional MRI examination.
- 1 January 2004
- Vol. 98, 75-81
The compensation of head motion artifacts using an infrared tracking system and a new algorithm for fMRI.
We aim to provide a next generation Magnetic Resonance Imaging (MRI) technology with an integrated solution for reducing motion artifacts in brain imaging applications. New developments in the field of MRI are revolutionizing the diagnostic capabilities e.g. of functional (fMRI) of the technique. Unfortunately, motion artifacts are eminent problems in cerebral MRI images, especially in difficult patient populations (e.g. chronic pain, children, neonates). Patient motion artifacts are present in 2D sequences, but are extremely detrimental in multi-slice 3D sequences often employed in fMRI. The problem of motion compensation in MRI technology deals with: Identification of the source as well as pattern of motion. Obtaining a mathematical model of motion that can be used to identify and then compensate the motion effects. Optimizing the image acquisition sequence in order to minimize, or even eliminate, the effect of motion. We propose a method to obtain a quantitative measure of the movement of the head between different data acquisition points in both MRI, and functional MRI examination.
- 1 January 2001
- Published by Springer Nature
- p. 351-362
EXOMIO: A 3D Simulator for External Beam Radiotherapy
- 1 January 2001
- Published by Springer Nature
- p. 351-362
EXOMIO: A 3D Simulator for External Beam Radiotherapy
- 1 August 1993
- Published by Springer Nature in The Visual Computer
- Vol. 9 (8) , 425-438
Interactive volume rendering of large fields
- 1 August 1993
- Published by Springer Nature in The Visual Computer
- Vol. 9 (8) , 425-438
Interactive volume rendering of large fields
- 1 August 1993
- Published by Wiley in Computer Graphics Forum
- Vol. 12 (3) , 329-338
Pseudo‐Satellitefilm Using Fractal Clouds to Enhance Animated Weather Forecasting
We have developed a system enabling the National German Meteorological Office to generate pseudo‐satellite images and video sequences based on their weather forecasting simulation data. With our system meteorologists can visualize the past and the current weather situation, evaluate their simulation results, and produce animated weather forecast videos broadcasted by several television stations. Realistic images are generated by interpolating the extremely coarse weather simulation data grid and enhancing the result using fractal clouds. It also enables the meteorologists to interactively change the forecast data in order to compensate the lack of accuracy or the known errors in their simulation models. Our system TRITON enables the visualization of complex weather simulations in a more natural way by presenting an intuitively understandable forecast.
- 1 August 1993
- Published by Wiley in Computer Graphics Forum
- Vol. 12 (3) , 329-338
Pseudo‐Satellitefilm Using Fractal Clouds to Enhance Animated Weather Forecasting
We have developed a system enabling the National German Meteorological Office to generate pseudo‐satellite images and video sequences based on their weather forecasting simulation data. With our system meteorologists can visualize the past and the current weather situation, evaluate their simulation results, and produce animated weather forecast videos broadcasted by several television stations. Realistic images are generated by interpolating the extremely coarse weather simulation data grid and enhancing the result using fractal clouds. It also enables the meteorologists to interactively change the forecast data in order to compensate the lack of accuracy or the known errors in their simulation models. Our system TRITON enables the visualization of complex weather simulations in a more natural way by presenting an intuitively understandable forecast.
- 1 May 1992
- Published by Wiley in Computer Graphics Forum
- Vol. 11 (3) , 107-117
A Functional Approach to the Visual Simulation of Gaseous Turbulence
- 1 May 1992
- Published by Wiley in Computer Graphics Forum
- Vol. 11 (3) , 107-117
A Functional Approach to the Visual Simulation of Gaseous Turbulence