André Rüffer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
André Rüffer has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Sven Dittrich
Department of Pediatric Cardiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
14 shared publications - Robert Cesnjevar
Department of Cardiac Surgery, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, 91054 Erlangen, Germany
11 shared publications Ariawan Purbojo
From the Departments of Pediatrics and Adolescent Medicine (F.K., A.P.R., A.L.W., A.N., J.W., J.J.), Congenital Heart Surgery (R.C., A.P., F.M.), and Pediatric Cardiology (S.D.), University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Loschgestrasse 15, 91054 Erlangen, Germany; and Section for Congenital and Pediatric Cardiac Surgery, University Heart Center Hamburg, University Hospital Hamburg, Eppendorf, Hamburg, Germany (A.R.).
9 shared publications- Ariawan Purbojo
Department of Paediatric Cardiac Surgery, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
9 shared publications - Frank Münch
Herzchirurgie Erlangen, Sektion Perfusiologie/Kardiotechnik, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
9 shared publications Okan Toka
Department of Pediatric Cardiology, University-Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
6 shared publications
Latest Publications
- 1 August 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (4)
Optimizing Photon-counting CT for Congenital Heart Disease: The Value of Ultrasharp Kernels in Neonates and Infants
Ultrasharp kernel settings and high iterative reconstruction levels improved effective image resolution and diagnostic image quality in photon-counting detector CT for neonates and infants with congenital heart disease, based on both quantitative and visual assessments.
- 1 August 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (4)
Optimizing Photon-counting CT for Congenital Heart Disease: The Value of Ultrasharp Kernels in Neonates and Infants
Ultrasharp kernel settings and high iterative reconstruction levels improved effective image resolution and diagnostic image quality in photon-counting detector CT for neonates and infants with congenital heart disease, based on both quantitative and visual assessments.
- Top Cited Papers
- 1 June 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (5) , 223088
Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience
Background Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing. Purpose To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive. Results Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P < .001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 ± 16.3 vs 29.9 ± 15.3, respectively; P = .007) and CNR (62.0 ± 50.3 vs 37.2 ± 20.8, respectively; P = .001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P = .47). Conclusion At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects. © RSNA, 2023.
- 1 June 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (5) , 223088
Top Cited PapersPhoton-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience
Background Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing. Purpose To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive. Results Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P < .001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 ± 16.3 vs 29.9 ± 15.3, respectively; P = .007) and CNR (62.0 ± 50.3 vs 37.2 ± 20.8, respectively; P = .001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P = .47). Conclusion At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects. © RSNA, 2023.
- 13 April 2023
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 195 (S 01) , S19-S20
Photon-Counting CT (PC-CT) vs. Standard Dual-Source CT (DS-CT) bei Neonaten und Kleinkindern mit kongenitalen Herzfehlern: Erste Erfahrungen bezüglich Bildqualität und Strahlendosis
Zielsetzung Vergleich von Bildqualität und Strahlendosis zwischen PC-CT und DS-CT bei Neugeborenen und Kleinkindern mit angeborenen Herzfehlern. Material und Methoden Prospektive Studie bei Neugeborenen und Kleinkindern mit sonographischem Verdacht auf kongenitalen Herzfehler, die entweder eine kontrastverstärkte PC-CT oder ein DS-CT des Herzens erhielten. Berechnung der effektiven Strahlendosis (eRD) mittels CT-Dosis-Index (CTDI) und Dosis-Längen-Produkt (DLP). SNR und CNR wurden durch standardisierte ROI-Analysen in Aorta descendens und subkutanem Fettgewebe berechnet, zudem SNR- und CNR-Dosis-Verhältnis. Die Bildqualität der CT-Aufnahmen sowie der 3D-Rekonstruktionen wurde von vier unabhängigen Readern anhand einer Likert-Skala semiquantitativ bewertet. Ergebnisse Insgesamt 109 Neugeborene und Kleinkinder (männlich: 57, weiblich: 52, mittleres Alter: 167,5 Tage±209,6 Tage, mittlere Größe: 60 cm±11,8, mittleres Gewicht: 5,5 kg±2,8) erhielten entweder ein kontrastverstärktes PC-CT (n=25) oder DS-CT (n=84) des Herzens. Eine mindestens diagnostische Bildqualität wurde in 24/25 (96%) der PC-CT- gegenüber 71/84 (84,5%) der DS-CT erzielt. Die mittlere Gesamtwertung der Bildqualität lag bei PC-CT signifikant höher als bei DS-CT (4,17 vs. 3,16; p<0,001). Die Bildqualität wurde von 37,5% vs. 4% als "ausgezeichnet", in 43,8% vs. 32,3% als "gut", in 17,2% vs. 40,3% als "mäßig", in 1,6% vs. 21% als "eingeschränkt" und in 0% vs. 1,6% als "schlecht/nicht diagnostisch" bewertet. SNR und CNR waren bei PC-CT signifikant höher als bei DS-CT: 46,3±16,3 vs. 29,9±15,3 und 62,0±50,3 vs. 37,2±20,8 (p=0,003 und p=0,032) (95% CI: -27,1 – 5,78). SNR- und CNR-Dosis-Verhältnis waren signifikant höher in PC-CT vs. DS-CT, mit 106,4±51,4 vs. 76,2±45,5 (p=0,045) und 191,9±161,2 vs. 103,1±84,2, p=0,042. Mittleres DLP und eRD waren bei PC-CT gering, aber nicht signifikant niedriger als bei DS-CT (14,34±6,63 vs. 16,14±9,26; 95% CI: -4,4-5,11, p=0,366 und 0,459 mSv±0,23 vs. 0,516 mSv±0,3 (95% CI: -0,46 – 0,558 mSv, p=0,470. Schlussfolgerungen PC-CT bietet im Vergleich zur konventionellen DS-CT bei Neugeborenen mit kongenitalen Herzfehlern ein deutlich höheres SNR und CNR und damit eine höhere Bildqualität bei einer zeitgleich geringfügig geringeren Strahlenbelastung. Article published online: 13 April 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- 13 April 2023
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 195 (S 01) , S19-S20
Photon-Counting CT (PC-CT) vs. Standard Dual-Source CT (DS-CT) bei Neonaten und Kleinkindern mit kongenitalen Herzfehlern: Erste Erfahrungen bezüglich Bildqualität und Strahlendosis
Zielsetzung Vergleich von Bildqualität und Strahlendosis zwischen PC-CT und DS-CT bei Neugeborenen und Kleinkindern mit angeborenen Herzfehlern. Material und Methoden Prospektive Studie bei Neugeborenen und Kleinkindern mit sonographischem Verdacht auf kongenitalen Herzfehler, die entweder eine kontrastverstärkte PC-CT oder ein DS-CT des Herzens erhielten. Berechnung der effektiven Strahlendosis (eRD) mittels CT-Dosis-Index (CTDI) und Dosis-Längen-Produkt (DLP). SNR und CNR wurden durch standardisierte ROI-Analysen in Aorta descendens und subkutanem Fettgewebe berechnet, zudem SNR- und CNR-Dosis-Verhältnis. Die Bildqualität der CT-Aufnahmen sowie der 3D-Rekonstruktionen wurde von vier unabhängigen Readern anhand einer Likert-Skala semiquantitativ bewertet. Ergebnisse Insgesamt 109 Neugeborene und Kleinkinder (männlich: 57, weiblich: 52, mittleres Alter: 167,5 Tage±209,6 Tage, mittlere Größe: 60 cm±11,8, mittleres Gewicht: 5,5 kg±2,8) erhielten entweder ein kontrastverstärktes PC-CT (n=25) oder DS-CT (n=84) des Herzens. Eine mindestens diagnostische Bildqualität wurde in 24/25 (96%) der PC-CT- gegenüber 71/84 (84,5%) der DS-CT erzielt. Die mittlere Gesamtwertung der Bildqualität lag bei PC-CT signifikant höher als bei DS-CT (4,17 vs. 3,16; p<0,001). Die Bildqualität wurde von 37,5% vs. 4% als "ausgezeichnet", in 43,8% vs. 32,3% als "gut", in 17,2% vs. 40,3% als "mäßig", in 1,6% vs. 21% als "eingeschränkt" und in 0% vs. 1,6% als "schlecht/nicht diagnostisch" bewertet. SNR und CNR waren bei PC-CT signifikant höher als bei DS-CT: 46,3±16,3 vs. 29,9±15,3 und 62,0±50,3 vs. 37,2±20,8 (p=0,003 und p=0,032) (95% CI: -27,1 – 5,78). SNR- und CNR-Dosis-Verhältnis waren signifikant höher in PC-CT vs. DS-CT, mit 106,4±51,4 vs. 76,2±45,5 (p=0,045) und 191,9±161,2 vs. 103,1±84,2, p=0,042. Mittleres DLP und eRD waren bei PC-CT gering, aber nicht signifikant niedriger als bei DS-CT (14,34±6,63 vs. 16,14±9,26; 95% CI: -4,4-5,11, p=0,366 und 0,459 mSv±0,23 vs. 0,516 mSv±0,3 (95% CI: -0,46 – 0,558 mSv, p=0,470. Schlussfolgerungen PC-CT bietet im Vergleich zur konventionellen DS-CT bei Neugeborenen mit kongenitalen Herzfehlern ein deutlich höheres SNR und CNR und damit eine höhere Bildqualität bei einer zeitgleich geringfügig geringeren Strahlenbelastung. Article published online: 13 April 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 July 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (1) , 164-173
Transfontanellar Contrast-enhanced US for Intraoperative Imaging of Cerebral Perfusion during Neonatal Arterial Switch Operation
Transfontanellar contrast-enhanced US enables intraoperative imaging and quantification of cerebral perfusion during neonatal heart surgery. Background Brain injury and subsequent neurodevelopmental disorders are major determinants for later-life outcomes in neonates with transposition of the great arteries (TGA). Purpose To quantitativ...
- 1 July 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (1) , 164-173
Transfontanellar Contrast-enhanced US for Intraoperative Imaging of Cerebral Perfusion during Neonatal Arterial Switch Operation
Transfontanellar contrast-enhanced US enables intraoperative imaging and quantification of cerebral perfusion during neonatal heart surgery. Background Brain injury and subsequent neurodevelopmental disorders are major determinants for later-life outcomes in neonates with transposition of the great arteries (TGA). Purpose To quantitativ...
- Open Access
- 12 February 2019
- Published by Springer Nature in BMC Pediatrics
- Vol. 19 (1) , 1-11
First experience with Tolvaptan for the treatment of neonates and infants with capillary leak syndrome after cardiac surgery
Postoperative fluid management in critically ill neonates and infants with capillary leak syndrome (CLS) and extensive volume overload after cardiac surgery on cardiopulmonary bypass is challenging. CLS is often resistant to conventional diuretic therapy, aggravating the course of weaning from invasive ventilation, increasing length of stay on ICU and morbidity and mortality. Tolvaptan (TLV, vasopressin type 2 receptor antagonist) was used as an additive diuretic in neonates and infants with CLS after cardiac surgery. Retrospective analysis of 25 patients with CLS including preoperative and postoperative parameters was performed. Multivariate regression analysis was performed to identify predictors for TLV response. Multivariate analysis identified urinary output during 24 h after TLV administration and mean blood pressure (BP) on day 2 of TLV treatment as predictors for TLV response (AUC = 0.956). Responder showed greater weight reduction (p < 0.0001), earlier weaning from ventilator during TLV (p = 0.0421) and shorter time in the ICU after TLV treatment (p = 0.0155). Serum sodium and serum osmolality increased significantly over time in all patients treated with TLV. In neonates and infants with diuretic-refractory CLS after cardiac surgery, additional aquaretic therapy with TLV showed an increase in urinary output and reduction in bodyweight in patients classified as TLV responder. Increase in urinary output and mean BP on day 2 of treatment were strong predictors for TLV response.
- 12 February 2019
- Published by Springer Nature in BMC Pediatrics
- Vol. 19 (1) , 1-11
Open AccessFirst experience with Tolvaptan for the treatment of neonates and infants with capillary leak syndrome after cardiac surgery
Postoperative fluid management in critically ill neonates and infants with capillary leak syndrome (CLS) and extensive volume overload after cardiac surgery on cardiopulmonary bypass is challenging. CLS is often resistant to conventional diuretic therapy, aggravating the course of weaning from invasive ventilation, increasing length of stay on ICU and morbidity and mortality. Tolvaptan (TLV, vasopressin type 2 receptor antagonist) was used as an additive diuretic in neonates and infants with CLS after cardiac surgery. Retrospective analysis of 25 patients with CLS including preoperative and postoperative parameters was performed. Multivariate regression analysis was performed to identify predictors for TLV response. Multivariate analysis identified urinary output during 24 h after TLV administration and mean blood pressure (BP) on day 2 of TLV treatment as predictors for TLV response (AUC = 0.956). Responder showed greater weight reduction (p < 0.0001), earlier weaning from ventilator during TLV (p = 0.0421) and shorter time in the ICU after TLV treatment (p = 0.0155). Serum sodium and serum osmolality increased significantly over time in all patients treated with TLV. In neonates and infants with diuretic-refractory CLS after cardiac surgery, additional aquaretic therapy with TLV showed an increase in urinary output and reduction in bodyweight in patients classified as TLV responder. Increase in urinary output and mean BP on day 2 of treatment were strong predictors for TLV response.
- 29 August 2018
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 33 (1) , 72-78
Kinderherzchirurgische Aortenbogenoperation
- 29 August 2018
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 33 (1) , 72-78
Kinderherzchirurgische Aortenbogenoperation
- Open Access
- 6 April 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 27 (4) , 591-597
Systemic-to-pulmonary artery shunting using heparin-bonded grafts
Systemic-to-pulmonary artery shunting remains an important palliative procedure in the staged management of complex congenital heart defects. The use of heparin-bonded polytetrafluoroethylene shunts (HBPSs) should enhance graft patency. This study aimed to review the single-centre experience using HBPS in the context of congenital cardiac surgery. The records of 51 patients treated using HBPS between 2010 and 2016 were retrospectively reviewed. The median age and weight of the patients were 8 (range 3–83) days and 3.2 (range 1.8–5.7) kg, respectively. Selected shunt size was 3.5 mm in all patients. Fourteen (27.5%) patients were planned for future biventricular repair and 37 (72.5%) patients underwent univentricular pathway. Shunt modifications included central aortopulmonary shunts (n = 35; 68.6%) and modified Blalock–Taussig shunts (n = 16; 31.4%). Shunt patency and survival until estimated 2nd procedure were calculated using the Kaplan–Meier method. Shunt patency was 90 ± 4% after a median duration of 133 (range 0–315) days. Early mortality (30 days) was 3.9% (n = 2). Another 3 patients died during their hospital stay. All the deceased patients had univentricular morphology, and the cause of death was not shunt related in all patients. Five patients developed subtotal HBPS thrombosis intraoperatively (n = 3), early postoperatively after 3 days (n = 1, 1.9%) or late after 41 days (n = 1, 1.9%). Treatment of those patients comprised right ventricular outflow tract opening (n = 2, 3.9%) or new shunting (n = 3, 5.9%). Elective shunt takedown was performed during corrective surgery (n = 10, 19.6%), bidirectional Glenn (n = 25, 49%) or shunt replacement (n = 5, 9.8%). At the end of follow-up, 1 (1.9%) patient had still an HBPS in situ. The survival rate until planned 2nd procedure was 87 ± 6% in univentricular patients and 100% in biventricular patients (P = 0.17). The use of HBPS in the context of palliative heart surgery is safe and seems to warrant a long-term patency of systemic-to-pulmonary shunts. However, by acting on only 1 site of Virchow’s triad, shunt thrombosis, occurring predominantly early, cannot be totally excluded.
- 6 April 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 27 (4) , 591-597
Open AccessSystemic-to-pulmonary artery shunting using heparin-bonded grafts
Systemic-to-pulmonary artery shunting remains an important palliative procedure in the staged management of complex congenital heart defects. The use of heparin-bonded polytetrafluoroethylene shunts (HBPSs) should enhance graft patency. This study aimed to review the single-centre experience using HBPS in the context of congenital cardiac surgery. The records of 51 patients treated using HBPS between 2010 and 2016 were retrospectively reviewed. The median age and weight of the patients were 8 (range 3–83) days and 3.2 (range 1.8–5.7) kg, respectively. Selected shunt size was 3.5 mm in all patients. Fourteen (27.5%) patients were planned for future biventricular repair and 37 (72.5%) patients underwent univentricular pathway. Shunt modifications included central aortopulmonary shunts (n = 35; 68.6%) and modified Blalock–Taussig shunts (n = 16; 31.4%). Shunt patency and survival until estimated 2nd procedure were calculated using the Kaplan–Meier method. Shunt patency was 90 ± 4% after a median duration of 133 (range 0–315) days. Early mortality (30 days) was 3.9% (n = 2). Another 3 patients died during their hospital stay. All the deceased patients had univentricular morphology, and the cause of death was not shunt related in all patients. Five patients developed subtotal HBPS thrombosis intraoperatively (n = 3), early postoperatively after 3 days (n = 1, 1.9%) or late after 41 days (n = 1, 1.9%). Treatment of those patients comprised right ventricular outflow tract opening (n = 2, 3.9%) or new shunting (n = 3, 5.9%). Elective shunt takedown was performed during corrective surgery (n = 10, 19.6%), bidirectional Glenn (n = 25, 49%) or shunt replacement (n = 5, 9.8%). At the end of follow-up, 1 (1.9%) patient had still an HBPS in situ. The survival rate until planned 2nd procedure was 87 ± 6% in univentricular patients and 100% in biventricular patients (P = 0.17). The use of HBPS in the context of palliative heart surgery is safe and seems to warrant a long-term patency of systemic-to-pulmonary shunts. However, by acting on only 1 site of Virchow’s triad, shunt thrombosis, occurring predominantly early, cannot be totally excluded.
- 1 January 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 103 (1) , 178-185
Comparable Cerebral Blood Flow in Both Hemispheres During Regional Cerebral Perfusion in Infant Aortic Arch Surgery
- 1 January 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 103 (1) , 178-185
Comparable Cerebral Blood Flow in Both Hemispheres During Regional Cerebral Perfusion in Infant Aortic Arch Surgery
- Open Access
- 22 August 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (6) , 933-939
Performance of stented biological valves for right ventricular outflow tract reconstruction
This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19–27), 22.8 years (range 5–77) and 62.0 kg (range 14–110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79–97], 81% (CI 64–91) and 60% (CI 40–78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation.
- 22 August 2016
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 23 (6) , 933-939
Open AccessPerformance of stented biological valves for right ventricular outflow tract reconstruction
This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19–27), 22.8 years (range 5–77) and 62.0 kg (range 14–110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79–97], 81% (CI 64–91) and 60% (CI 40–78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation.
- Open Access
- 1 July 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (4) , 482-490
Pediatric Extracorporeal Life Support Using a Third Generation Diagonal Pump
This study reports a single-centre experience of the Medos Deltastream diagonal-pump (DP3) for extracorporeal cardiac, pulmonary, or combined support in a single-center pediatric cohort. Twenty-seven consecutive patients with 28 runs of the DP3 between January 2013 and June 2014 were included for analysis. Median patient age, weight, and duration of support were 278 days (range: 0 days–14.2 years), 7.2 kg (range: 2.5–39 kg), and 8 days (range: 2–69 days). Midline sternotomy (n = 20, 71.4%) or cervical approaches (n = 8, 28.6%) were used for cannulation. The DP3 was employed for either veno-arterial extracorporeal life support (ECLS, n = 16), veno-venous extracorporeal membrane oxygenation (ECMO, n = 5), or ventricular assist devices (right ventricular assist device [RVAD], n = 1; left ventricular assist device [LVAD], n = 1; and univentricular assist device [UNIVAD], n = 5). Three patients initially supported with ECLS were switched to UNIVAD and one patient with UNIVAD was changed to ECLS. Required flow for neonates (n = 8) ranged between 0.2 and 0.75 L/min. Irreversible pump damage occurred in one patient during deairing after air block. Successful weaning, 30 day and hospital survival were 89.3% (n = 25), 85.7% (n = 24), and 71.4% (n = 20). All patients on UNIVAD, who did not require further extracorporeal respiratory assist, survived. In conclusion, the DP3 can be used for individual patient demands and adapted to their most suitable method of support. Meticulous flow adjustments render this pump highly effective for extracorporeal support particularly in pediatric patients.
- 1 July 2016
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 62 (4) , 482-490
Open AccessPediatric Extracorporeal Life Support Using a Third Generation Diagonal Pump
This study reports a single-centre experience of the Medos Deltastream diagonal-pump (DP3) for extracorporeal cardiac, pulmonary, or combined support in a single-center pediatric cohort. Twenty-seven consecutive patients with 28 runs of the DP3 between January 2013 and June 2014 were included for analysis. Median patient age, weight, and duration of support were 278 days (range: 0 days–14.2 years), 7.2 kg (range: 2.5–39 kg), and 8 days (range: 2–69 days). Midline sternotomy (n = 20, 71.4%) or cervical approaches (n = 8, 28.6%) were used for cannulation. The DP3 was employed for either veno-arterial extracorporeal life support (ECLS, n = 16), veno-venous extracorporeal membrane oxygenation (ECMO, n = 5), or ventricular assist devices (right ventricular assist device [RVAD], n = 1; left ventricular assist device [LVAD], n = 1; and univentricular assist device [UNIVAD], n = 5). Three patients initially supported with ECLS were switched to UNIVAD and one patient with UNIVAD was changed to ECLS. Required flow for neonates (n = 8) ranged between 0.2 and 0.75 L/min. Irreversible pump damage occurred in one patient during deairing after air block. Successful weaning, 30 day and hospital survival were 89.3% (n = 25), 85.7% (n = 24), and 71.4% (n = 20). All patients on UNIVAD, who did not require further extracorporeal respiratory assist, survived. In conclusion, the DP3 can be used for individual patient demands and adapted to their most suitable method of support. Meticulous flow adjustments render this pump highly effective for extracorporeal support particularly in pediatric patients.