Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Serguei N. Lvov has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermodynamic Modeling of Mineral Scaling in High-Temperature and High-Pressure Aqueous Environments

    by Derek M. Hall, Serguei N. Lvov, Isaac K. Gamwo

    Methods of predicting mineral scale formation have evolved over the years from simple empirical fittings to sophisticated computational programs. Though best practices can now solve complex multi-phase, multi-component systems, they are largely restricted to temperatures below 300 °C. This review examines critical gaps in existing mineral scale modeling approaches as well as strategies to overcome them. Above 300 °C, the most widely used model of standard thermodynamic functions for aqueous species fails when fluid densities are below 0.7 g cm−3. This failure occurs due to the model’s reliance on an empirical form of the Born equation which is unable to capture the trends observed in these high temperature, low density regimes. However, new models based on molecular solvent-solute interactions offer a pathway to overcome some of the deficiencies currently limiting high-temperature and high-pressure mineral scale predictions. Examples of the most common scale prediction methods are presented, and their advantages and disadvantages are discussed.


  • Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

    by Timothy S. Duffy, Isaac K. Gamwo, Russell T. Johns, Serguei N. Lvov

    Summary: Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. The Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.


  • Technical Note: Monitoring X65 Steel Internal Corrosion in Humidified N2-Containing H2S Using Membrane-Based Electrochemical Sensors

    by Timothy S. Duffy, Derek M. Hall, Margaret Ziomek-Moroz, Serguei N. Lvov

    This paper will report on a new membrane-based electrochemical sensor that may provide an important utility in monitoring and characterizing internal corrosion of natural gas pipelines. Using this sensor, the corrosion rate of X65 steel exposed to H2S in humidified environments up to 60°C has been measured. Consistent with the authors’ earlier CO2 study, the membrane’s conductivity did not change when exposed to H2S-containing acidic gas. Introducing H2S consistently increased the measured corrosion rate between testing conditions, though corrosion rates were typically less than 2 μm/y. At 30°C, the corrosion rate doubled from 7.3 nm/y to 14 nm/y below a relative humidity of 30%, and it increased by an order of magnitude (0.19 μm/y to 1.9 μm/y) at 55% relative humidity, showing that the influence of H2S on corrosion increases dramatically with greater humidity. Trends with relative humidity match industry expectations: the corrosion rate is low (<0.25 μm/y) without the presence of a condensed aqueous phase, but it increases as the water content of the system increases. The membrane-based electrochemical sensor (MBES) was therefore able to capture relevant corrosion trends, even while the corrosion rates would not have presented a serious threat to any natural gas pipeline. As such, the MBES can be used to detect the onset of emerging corrosion threats before they occur. Field emission scanning electron microscopy and energy-dispersive x-ray spectroscopy confirmed that H2S reacted with the metal covered by the membrane phase, showing evidence of sulfur-rich sites on the X65 surface. In addition, finite element analysis (FEA) confirmed that electrochemical measurements and data analysis techniques could be successfully used for this membrane-based sensor, despite its unconventional cell geometry.


  • Electrochemical impedance spectroscopy and finite element analysis modeling of a 4-electrode humidity sensor for natural gas transportation pipelines

    by Derek M. Hall, Timothy Duffy, Margaret Ziomek-Moroz, Serguei N. Lvov

    Reliable corrosion monitoring of natural gas transmission lines is a major tool providing a foundation for safe management of natural gas infrastructures. Through the development of membrane-based electrochemical sensors which are able to function in low-conductivity gas environments, corrosion monitoring practices can be further strengthened by real-time monitoring of key risk factors such as relative humidity and corrosion rates of corrodible structures. In this work, we demonstrate and validate how a 4-electrode conductivity sensor can provide a means to monitor relative humidity in gases via electrochemical impedance spectroscopy through finite element analysis (FEA). For a relative humidity range of 5%–55%, the impedance response varied from 1 kΩ to 66 kΩ, showing a high sensitivity for gas humidity. To confirm that the measured impedance values reliably interpreted relative humidity, it was found that precise estimation of the sensor’s cell constant was needed. FEA was used to assess how the cell constant depended on the electrode geometry, membrane geometry, and electrode placement within the sensor. Through this approach, assumptions about the characteristic area and length were validated using electrolyte equipotential and current density vector mapping. This reduced possible cell constant uncertainties by 70%. With a cell constant of 14.84 cm−1, obtained via FEA, membrane conductivity values were in good agreement with published data.


  • Advancing Reliability of Membrane-Based Corrosion and Environmental Sensor in Simulated Natural Gas

    by Timothy Duffy, Derek M. Hall, Margaret Ziomek-Moroz, Serguei N. Lvov

    A significant progress was made on developing membrane-based advanced electrochemical sensors (AESs) to improve their consistency, cost, and measurement quality by means of experimentation and finite element analysis. Consistency of the AESs were improved by better characterization of the cell geometry and localized thermocouple installation. Experimental artefacts were reduced by connecting the working and reference electrodes with 50 nF capacitors. Finite element analysis shows that the AESs should incorporate thin, long electrodes with small separations in contact with a thicker membrane to improve measurement quality.

  • Open Access

    Effects of CO2 and H2S on Corrosion of Martensitic Steels in Brines at Low Temperature

    by Ruishu Feng, Justin R. Beck, Derek M. Hall, Aysel Buyuksagis, Margaret Ziomek-Moroz, Serguei N. Lvov

    Corrosion studies were conducted for martensitic carbon steels in 5 wt% NaCl brine solutions at 4°C and 10 MPa (1,450 psi). These studies simulated different subsurface environments relevant to Arctic drilling. Here, two high-strength martensitic carbon steels, S-135 and UD-165, were studied in three different environments: (1) a CO2-NaCl-H2O solution with a CO2:H2O molar ratio of 0.312 in the whole system, (2) an H2S-NaCl-H2O solution with an H2S:H2O molar ratio of 3.12 × 10−4, and (3) a CO2-H2S-NaCl-H2O solution with the same acid gas to water ratios as environments 1 and 2. Results from the CO2+H2S mixed environment indicated that sour corrosion mechanism was dominant when the CO2:H2S molar ratio was 1,000. This impact of a small amount of H2S on the corrosion mechanism could be attributed to the specific adsorption of H2S on the steel surface. Electrochemical and mass loss measurements showed a distinct drop in the corrosion rate (CR) by more than one order of magnitude when transitioning from sweet to sour corrosion. This inhibiting effect on CR was attributed to the formation of a protective sulfide thin film. Tafel analyses of the anodic reaction showed that the Bockris mechanism was unlikely in the conditions tested. When comparisons were made between modeled and experimental CRs, good agreement was found in the CO2-only and H2S-only environments, but not in the CO2+H2S environment.


  • Experimental studies and modeling of CO2 solubility in high temperature aqueous CaCl2, MgCl2, Na2SO4, and KCl solutions

    by Haining Zhao, Robert M. Dilmore, Serguei N. Lvov

    The phase equilibria of CO2 and aqueous electrolyte solutions are important to various chemical‐, petroleum‐, and environmental‐related technical applications. CO2 solubility in aqueous CaCl2, MgCl2, Na2SO4, and KCl solutions at a pressure of 15 MPa, the temperatures from 323 to 423 K, and the ionic strength from 1 to 6 mol kg−1 were measured. Based on the measured experimental CO2 solubility, the previous developed fugacity‐activity thermodynamic model for the CO2‐NaCl‐H2O system was extended to account for the effects of different salt species on CO2 solubility in aqueous solutions at temperatures up to 523 K, pressures up to 150 MPa, and salt concentrations up to saturation. Comparisons of different models against literature data reveal a clear improvement of the proposed PSUCO2 model in predicting CO2 solubility in aqueous salt solutions. © 2015 American Institute of Chemical Engineers AIChE J, 61: 2286–2297, 2015


  • Measurement and Modeling of CO2Solubility in Natural and Synthetic Formation Brines for CO2Sequestration

    by Haining Zhao, Robert Dilmore, Douglas E. Allen, Sheila W. Hedges, Yee Soong, Serguei N. Lvov

    CO2 solubility data in the natural formation brine, synthetic formation brine, and synthetic NaCl+CaCl2 brine were collected at the pressures from 100 to 200 bar, temperatures from 323 to 423 K. Experimental results demonstrate that the CO2 solubility in the synthetic formation brines can be reliably represented by that in the synthetic NaCl+CaCl2 brines. We extended our previously developed model (PSUCO2) to calculate CO2 solubility in aqueous mixed-salt solution by using the additivity rule of the Setschenow coefficients of the individual ions (Na+, Ca2+, Mg2+, K+, Cl–, and SO42–). Comparisons with previously published models against the experimental data reveal a clear improvement of the proposed PSUCO2 model. Additionally, the path of the maximum gradient of the CO2 solubility contours divides the P-T diagram into two distinct regions: in Region I, the CO2 solubility in the aqueous phase decreases monotonically in response to increased temperature; in region II, the behavior of the CO2 solubility is the opposite of that in Region I as the temperature increases.


  • Open Access

    Effect of Clamping Pressure and Temperature on the Performance of a CuCl(aq)/HCl(aq) Electrolyzer

    by Sanchit Khurana, Derek M. Hall, Rich S. Schatz, Serguei N. Lvov

    Changes in the performance of a CuCl(aq)/HCl(aq) electrolytic cell are reported as a function of temperature and the compression pressure applied at the end plates during cell assembly. The pressure applied on the end plates effected the contact resistance, and an optimum compression pressure of 6.3 psi (bolt torque: 20 Nm) showed the best performance. Polarization curves and EIS data were taken at 40, 60, and 80°C to observe the changes in ohmic and nonohmic impedance contributions. A significant increase in the cell performance was observed as the temperature was increased from 40 to 80°C.


  • Open Access

    Electrochemical Kinetics of CuCl(aq)/HCl(aq) Electrolyzer for Hydrogen Production via a Cu-Cl Thermochemical Cycle

    by Derek M. Hall, Eric G. LaRow, Rich S. Schatz, Justin R. Beck, Serguei N. Lvov

    An electrochemical kinetics investigation of the CuCl(aq)/HCl(aq) electrolyzer identified methods to significantly reduce the platinum loadings required to achieve a high cell current density of 0.5 A/cm2 at 0.7 V. As the CuCl(aq)/HCl(aq) electrolyzer is a key component of the Cu-Cl thermochemical cycle, the economic viability of the Cu-Cl thermochemical cycle was significantly improved by reducing the loading required to achieve 0.5 A/cm2. Electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) with a rotating disc electrode were employed to investigate the kinetics of the aqueous CuII/CuI chloride complexes reaction on platinum and glassy carbon using a three-electrode cell. It was found that the standard exchange current density of the anodic CuII/CuI electrochemical reaction on platinum, 4–12 A/cm2, was significantly larger than the values reported for the HER cathodic reaction thus far. In addition, SEM was used to observe the effectiveness of different catalyst application techniques. Through SEM observations, and electrochemical data analysis, the amount of platinum used in a laboratory scale CuCl(aq)/HCl(aq) electrolyzer was reduced from 0.8 mg/cm2 applied to both electrodes to 0.4 mg/cm2 on the cathode and zero at the anode while still maintaining a current density of 0.5 A/cm2 at 0.7 V of applied potential difference.