Emil I. Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emil I. Cohen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
David B. Weinreb
1 shared publicationEric Wilck
1 shared publicationJoshua L. Weintraub
1 shared publicationMichael Marin
1 shared publicationRobert A. Lookstein
1 shared publicationRobert H. Siegelbaum
1 shared publication
Latest Publications
- 28 February 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (3) , 500-503
Time‐resolved MR angiography for the classification of endoleaks after endovascular aneurysm repair
Purpose: To evaluate the utility of time‐resolved MR angiography (TR‐MRA), compared with digital subtraction angiography (DSA), in the classification of endoleaks in patients who have undergone endovascular aneurysm repair (EVAR).Materials and Methods: Thirty‐one patients who had undergone EVAR to repair an abdominal aortic aneurysm were evaluated with both TR‐MRA and DSA to determine endoleak etiology. The patient population consisted of 26 men and 5 women with a mean age of 78.5 years (range, 55–93 years). The mean time interval between TR‐MRA and DSA was 1.5 weeks (range, 1–8 weeks). Endoleaks were classified as type II when enhancement of the external iliac vessels was observed before the appearance of the endoleak; otherwise the endoleak was classified as type I or III. The results of TR‐MRA classification were compared with the reference gold standard, DSA.Results: Agreement between TR‐MRA and DSA regarding endoleak classification occurred in 30 of 31 cases (97%). Discordant classification occurred in a case in which a Type II endoleak was misclassified as a Type III due to failure to visualize a lumbar vessel.Conclusion: TR‐MRA is highly effective in classifying endoleaks following EVAR when compared with DSA. J. Magn. Reson. Imaging 2008;27:500–503.
- 28 February 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (3) , 500-503
Time‐resolved MR angiography for the classification of endoleaks after endovascular aneurysm repair
Purpose: To evaluate the utility of time‐resolved MR angiography (TR‐MRA), compared with digital subtraction angiography (DSA), in the classification of endoleaks in patients who have undergone endovascular aneurysm repair (EVAR).Materials and Methods: Thirty‐one patients who had undergone EVAR to repair an abdominal aortic aneurysm were evaluated with both TR‐MRA and DSA to determine endoleak etiology. The patient population consisted of 26 men and 5 women with a mean age of 78.5 years (range, 55–93 years). The mean time interval between TR‐MRA and DSA was 1.5 weeks (range, 1–8 weeks). Endoleaks were classified as type II when enhancement of the external iliac vessels was observed before the appearance of the endoleak; otherwise the endoleak was classified as type I or III. The results of TR‐MRA classification were compared with the reference gold standard, DSA.Results: Agreement between TR‐MRA and DSA regarding endoleak classification occurred in 30 of 31 cases (97%). Discordant classification occurred in a case in which a Type II endoleak was misclassified as a Type III due to failure to visualize a lumbar vessel.Conclusion: TR‐MRA is highly effective in classifying endoleaks following EVAR when compared with DSA. J. Magn. Reson. Imaging 2008;27:500–503.
- 18 October 2006
- Published by Georg Thieme Verlag KG in Seminars in Liver Disease
- Vol. 26 (4) , 363-372
Hepatic Imaging in the 21st Century
Imaging of the liver has progressed rapidly during the past decade with continued advancement of current ultrasound, computed tomography, and magnetic resonance imaging (MRI). Each modality not only has seen refinement enabling better anatomic characterization of disease but also has received strength from the addition of new techniques to its resources. New contrast agents have become available for all modalities and some agents, particularly for MRI, have opened the way for better functional assessment. MRI continues to see an elaboration of sequences (including spectroscopy and diffusion) that also open imaging to the microscopic structure of disease and normal function. The further development of workstations have improved both analysis and depiction of disease. In the 21st century imaging will continue to shift from a simple source of anatomic information to a more functional problem-solving tool.
- 18 October 2006
- Published by Georg Thieme Verlag KG in Seminars in Liver Disease
- Vol. 26 (4) , 363-372
Hepatic Imaging in the 21st Century
Imaging of the liver has progressed rapidly during the past decade with continued advancement of current ultrasound, computed tomography, and magnetic resonance imaging (MRI). Each modality not only has seen refinement enabling better anatomic characterization of disease but also has received strength from the addition of new techniques to its resources. New contrast agents have become available for all modalities and some agents, particularly for MRI, have opened the way for better functional assessment. MRI continues to see an elaboration of sequences (including spectroscopy and diffusion) that also open imaging to the microscopic structure of disease and normal function. The further development of workstations have improved both analysis and depiction of disease. In the 21st century imaging will continue to shift from a simple source of anatomic information to a more functional problem-solving tool.