Walter R. Lempert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Walter R. Lempert has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Igor V. Adamovich
Department of Mechanical and Aerospace Engineering, The Ohio State University 1 , Columbus, Ohio 43210
4 shared publications N. Jiang
The Ohio State University
3 shared publicationsNaibo Jiang
Department of Mechanical Engineering, The Ohio State University, Columbus, Ohio 43201, USA
3 shared publicationsJ. Bruzzese
The Ohio State University
2 shared publicationsJ. W. Rich
Michael A. Chaszeyka Nonequilibrium Thermodynamics Laboratories, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, USA
2 shared publicationsM. Nishihara
Michael A. Chaszeyka Nonequilibrium Thermodynamics Laboratories, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, USA
2 shared publications
Latest Publications
- 21 December 2012
- Published by Springer Nature in Experiments in Fluids
- Vol. 54 (1) , 1-13
Picosecond CARS measurements of nitrogen rotational/translational and vibrational temperature in a nonequilibrium Mach 5 flow
- 21 December 2012
- Published by Springer Nature in Experiments in Fluids
- Vol. 54 (1) , 1-13
Picosecond CARS measurements of nitrogen rotational/translational and vibrational temperature in a nonequilibrium Mach 5 flow
- 15 September 2012
- Published by Springer Nature in Experiments in Fluids
- Vol. 53 (6) , 1637-1646
NO PLIF imaging in the CUBRC 48-inch shock tunnel
- 15 September 2012
- Published by Springer Nature in Experiments in Fluids
- Vol. 53 (6) , 1637-1646
NO PLIF imaging in the CUBRC 48-inch shock tunnel
- 6 October 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (29) , 5688-5694
Diagnostic study of four-wave-mixing-based electric-field measurements in high-pressure nitrogen plasmas
We present the results of a diagnostic study of the use of coherent four wave mixing for in situ measurement of an electric field in air or in nitrogen-containing plasmas. Static electric fields in air at a nominal pressure of and temperature of are detected using vibrational CARS of nitrogen. It is shown that the ratio of the infrared signal to the vibrational CARS signal is equal to approximately at , a factor of approximately 50 less than that predicted assuming equal third-order nonlinear susceptibilities. It is also shown that the spatial resolution of a typical collinear geometry measurement is approximately . Finally, it is shown that achieving sensitivities of the order of requires that the coherent Raman pumping be performed in the highly saturated and Stark broadened regime.- 6 October 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (29) , 5688-5694
Diagnostic study of four-wave-mixing-based electric-field measurements in high-pressure nitrogen plasmas
We present the results of a diagnostic study of the use of coherent four wave mixing for in situ measurement of an electric field in air or in nitrogen-containing plasmas. Static electric fields in air at a nominal pressure of and temperature of are detected using vibrational CARS of nitrogen. It is shown that the ratio of the infrared signal to the vibrational CARS signal is equal to approximately at , a factor of approximately 50 less than that predicted assuming equal third-order nonlinear susceptibilities. It is also shown that the spatial resolution of a typical collinear geometry measurement is approximately . Finally, it is shown that achieving sensitivities of the order of requires that the coherent Raman pumping be performed in the highly saturated and Stark broadened regime.- 14 October 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (4) , A20-A28
MHz-rate nitric oxide planar laser-induced fluorescence imaging in a Mach 10 hypersonic wind tunnel
Nitric oxide planar laser-induced fluorescence (NO PLIF) imaging at repetition rates as high as is demonstrated in the NASA Langley 31 in. Mach 10 hypersonic wind tunnel. Approximately 200 time- correlated image sequences of between 10 and 20 individual frames were obtained over eight days of wind tunnel testing spanning two entries in March and September of 2009. The image sequences presented were obtained from the boundary layer of a flat plate model, in which transition was induced using a variety of different shaped protuberances, including a cylinder and a triangle. The high-speed image sequences captured a variety of laminar and transitional flow phenomena, ranging from mostly laminar flow, typically at a lower Reynolds number and/or in the near wall region of the model, to highly transitional flow in which the temporal evolution and progression of characteristic streak instabilities and/or corkscrew-shaped vortices could be clearly identified.- 14 October 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (4) , A20-A28
MHz-rate nitric oxide planar laser-induced fluorescence imaging in a Mach 10 hypersonic wind tunnel
Nitric oxide planar laser-induced fluorescence (NO PLIF) imaging at repetition rates as high as is demonstrated in the NASA Langley 31 in. Mach 10 hypersonic wind tunnel. Approximately 200 time- correlated image sequences of between 10 and 20 individual frames were obtained over eight days of wind tunnel testing spanning two entries in March and September of 2009. The image sequences presented were obtained from the boundary layer of a flat plate model, in which transition was induced using a variety of different shaped protuberances, including a cylinder and a triangle. The high-speed image sequences captured a variety of laminar and transitional flow phenomena, ranging from mostly laminar flow, typically at a lower Reynolds number and/or in the near wall region of the model, to highly transitional flow in which the temporal evolution and progression of characteristic streak instabilities and/or corkscrew-shaped vortices could be clearly identified.- 18 September 2009
- Published by Elsevier in Chemical Physics
- Vol. 363 (1-3) , 24-32
Isotope effect in Boudouard disproportionation reaction in optically pumped CO
- 18 September 2009
- Published by Elsevier in Chemical Physics
- Vol. 363 (1-3) , 24-32
Isotope effect in Boudouard disproportionation reaction in optically pumped CO
- 20 October 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (4) , B23-B31
Advances in generation of high-repetition-rate burst mode laser output
It is demonstrated that the incorporation of variable pulse duration flashlamp power supplies into an Nd:YAG burst mode laser system results in very substantial increases in the realizable energy per pulse, the total pulse train length, and uniformity of the intensity envelope. As an example, trains of 20 pulses at burst frequencies of 50 and are demonstrated with individual pulse energy at of 220 and , respectively. Conversion efficiency to the second- () and third- () harmonic wavelengths of and 35–40%, respectively, is also achieved. Use of the third-harmonic output of the burst mode laser as a pump source for a simple, home built optical parametric oscillator (OPO) produces pulse trains of broadly wavelength tunable output. Sum-frequency mixing of OPO signal output at with residual output from the pump beam is shown to produce uniform bursts of tunable output at , with individual pulse energy of . Time-correlated NO planar laser induced fluorescence (PLIF) image sequences are obtained in a Mach 3 wind tunnel at , representing, to our knowledge, the first demonstration of NO PLIF imaging at repetition rates exceeding tens of hertz.- 20 October 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (4) , B23-B31
Advances in generation of high-repetition-rate burst mode laser output
It is demonstrated that the incorporation of variable pulse duration flashlamp power supplies into an Nd:YAG burst mode laser system results in very substantial increases in the realizable energy per pulse, the total pulse train length, and uniformity of the intensity envelope. As an example, trains of 20 pulses at burst frequencies of 50 and are demonstrated with individual pulse energy at of 220 and , respectively. Conversion efficiency to the second- () and third- () harmonic wavelengths of and 35–40%, respectively, is also achieved. Use of the third-harmonic output of the burst mode laser as a pump source for a simple, home built optical parametric oscillator (OPO) produces pulse trains of broadly wavelength tunable output. Sum-frequency mixing of OPO signal output at with residual output from the pump beam is shown to produce uniform bursts of tunable output at , with individual pulse energy of . Time-correlated NO planar laser induced fluorescence (PLIF) image sequences are obtained in a Mach 3 wind tunnel at , representing, to our knowledge, the first demonstration of NO PLIF imaging at repetition rates exceeding tens of hertz.- 29 September 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (19) , 2236-2238
Ultrahigh-frame-rate nitric oxide planar laser-induced fluorescence imaging
We demonstrate the ability to generate ultrahigh frequency burst sequences of deep UV at by mixing the optical parametric oscillator signal output at with third harmonic at from a pulse burst laser system. We obtained burst sequences with uniform burst envelopes, and the average pulse energy is . Nitric oxide planar laser-induced fluorescence image sequences at ultrahigh frame rates have been obtained.- 29 September 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (19) , 2236-2238
Ultrahigh-frame-rate nitric oxide planar laser-induced fluorescence imaging
We demonstrate the ability to generate ultrahigh frequency burst sequences of deep UV at by mixing the optical parametric oscillator signal output at with third harmonic at from a pulse burst laser system. We obtained burst sequences with uniform burst envelopes, and the average pulse energy is . Nitric oxide planar laser-induced fluorescence image sequences at ultrahigh frame rates have been obtained.- 8 May 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7005
Optimization and scaling of a pulser-sustainer discharge excited oxygen-iodine laser
The paper discusses optimization of gain and output power and scaling of a pulser-sustainer discharge excited oxygen-iodine laser. For this, NO addition to the laser mixture and iodine vapor dissociation in an auxiliary high-voltage, nanosecond pulse duration, repetitively pulsed discharge ("side" discharge) are used. Iodine dissociation fraction generated in the side discharge and measured in the M=3 laser cavity is up to 50%. The experiments showed that additional iodine dissociation generated in the side discharge only moderately increased laser gain, by 10-15%. Parametric gain optimization by varying main discharge pressure, O2 and NO fractions in the flow, I2 flow rate, pulsed discharge frequency, and sustainer discharge power, with the side discharge in operation produced gain up to 0.08 %/cm. Two parameters that critically affect gain are the energy loading per molecule in the discharge and the NO flow rate controlling the O atom concentration in the flow. Operation at the main discharge pressure of 60 torr resulted in significantly higher gain than at 100 torr, 0.080 %/cm vs. 0.043 %/cm, due to high discharge energy loading per molecule at the lower pressure. Laser output power measured at the gain optimized conditions is 1.4 W. Experiments with a scaled-up laser with a large volume pulser-sustainer discharge (10 cm x 10 cm x 2 cm vs. 5 cm x 5 cm x 2 cm) and longer gain path (10 cm vs. 5 cm) demonstrated stable discharge operation at discharge powers up to at least 2.9 kW. Singlet delta yield and gain measurements in the scaled-up laser are underway.
- 8 May 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7005
Optimization and scaling of a pulser-sustainer discharge excited oxygen-iodine laser
The paper discusses optimization of gain and output power and scaling of a pulser-sustainer discharge excited oxygen-iodine laser. For this, NO addition to the laser mixture and iodine vapor dissociation in an auxiliary high-voltage, nanosecond pulse duration, repetitively pulsed discharge ("side" discharge) are used. Iodine dissociation fraction generated in the side discharge and measured in the M=3 laser cavity is up to 50%. The experiments showed that additional iodine dissociation generated in the side discharge only moderately increased laser gain, by 10-15%. Parametric gain optimization by varying main discharge pressure, O2 and NO fractions in the flow, I2 flow rate, pulsed discharge frequency, and sustainer discharge power, with the side discharge in operation produced gain up to 0.08 %/cm. Two parameters that critically affect gain are the energy loading per molecule in the discharge and the NO flow rate controlling the O atom concentration in the flow. Operation at the main discharge pressure of 60 torr resulted in significantly higher gain than at 100 torr, 0.080 %/cm vs. 0.043 %/cm, due to high discharge energy loading per molecule at the lower pressure. Laser output power measured at the gain optimized conditions is 1.4 W. Experiments with a scaled-up laser with a large volume pulser-sustainer discharge (10 cm x 10 cm x 2 cm vs. 5 cm x 5 cm x 2 cm) and longer gain path (10 cm vs. 5 cm) demonstrated stable discharge operation at discharge powers up to at least 2.9 kW. Singlet delta yield and gain measurements in the scaled-up laser are underway.
- 21 April 2006
- Published by Elsevier in Chemical Physics
- Vol. 323 (2-3) , 532-544
Stimulated Raman scattering measurements of V–V transfer in oxygen
- 21 April 2006
- Published by Elsevier in Chemical Physics
- Vol. 323 (2-3) , 532-544
Stimulated Raman scattering measurements of V–V transfer in oxygen
- 20 July 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (21) , 4320-4326
Enhancement of spectral purity of injection-seeded titanium:sapphire laser by cavity locking and stimulated Brillouin scattering.
We report improvements to and better characterization of the spectral purity of a diode laser injection-seeded, cavity-locked titanium:sapphire laser that serves as the source for a previously reported rubidium vapor spectrally filtered Thomson scattering apparatus at 780.24 nm. In a detailed set of measurements the spectral purity P of the laser, defined as the ratio of the narrowband component of the laser output to the total output, has been studied as a function of frequency mismatch between the seed laser frequency and the central frequency of the unseeded cavity. It is found that spectral purity exceeding 0.999 can be obtained for a seed-cavity mismatch as high as ±0.25 nm, corresponding to approximately 950 cavity longitudinal-mode spacings and as high as ∼0.9999 for a cavity-seed mismatch in the range ±0.10 nm (380 mode spacings). It is also shown that the addition of an external-cavity stimulated Brillouin-scattering phase-conjugate mirror increases both the spectral purity, to a minimum of 0.99999, and the cavity-seed mismatch range, to ±0.25 nm, for which this maximum effective purity is obtained.
- 20 July 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (21) , 4320-4326
Enhancement of spectral purity of injection-seeded titanium:sapphire laser by cavity locking and stimulated Brillouin scattering.
We report improvements to and better characterization of the spectral purity of a diode laser injection-seeded, cavity-locked titanium:sapphire laser that serves as the source for a previously reported rubidium vapor spectrally filtered Thomson scattering apparatus at 780.24 nm. In a detailed set of measurements the spectral purity P of the laser, defined as the ratio of the narrowband component of the laser output to the total output, has been studied as a function of frequency mismatch between the seed laser frequency and the central frequency of the unseeded cavity. It is found that spectral purity exceeding 0.999 can be obtained for a seed-cavity mismatch as high as ±0.25 nm, corresponding to approximately 950 cavity longitudinal-mode spacings and as high as ∼0.9999 for a cavity-seed mismatch in the range ±0.10 nm (380 mode spacings). It is also shown that the addition of an external-cavity stimulated Brillouin-scattering phase-conjugate mirror increases both the spectral purity, to a minimum of 0.99999, and the cavity-seed mismatch range, to ±0.25 nm, for which this maximum effective purity is obtained.