DADaniel Arvidsson

Daniel Arvidsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Arvidsson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Physical activity, sports participation and aerobic fitness in children who have undergone surgery for congenital heart defects

    by D Arvidsson, F Slinde, L Hulthén, J Sunnegårdh

    Aim:  To investigate physical activity, sports participation and aerobic fitness in children who have undergone surgery for congenital heart defects.Subjects and methods:  Children who had undergone surgery for congenital heart defects and healthy controls in the Gothenburg area were invited to participate in the study. All participants were aged 9–11 or 14–16 years. The activity monitor ActiReg was used to assess physical activity. Participants were interviewed about their participation in sports and performed a maximal exercise test on a bicycle with measured oxygen uptake.Results:  A total of 32 and 25 patients, and 61 and 45 controls, in the two age‐groups were included, respectively. The patients had a wide range of severity of congenital heart defects. The physical activity level was similar in the patients and the controls. The rate of sports participation was high for both patients and controls; 80–94% of all participants took part in sports at least once a week. The majority of the patients were considered to have at least a moderate level of aerobic fitness.Conclusions:  Although children who have undergone surgery for congenital heart defects have a similar level of physical activity compared with that of healthy children, some of them may require support to participate in exercise and vigorous physical activity.


  • Energy Cost in Children Assessed by Multisensor Activity Monitors

    by Daniel Arvidsson, Frode Slinde, Sven Larsson, Lena Hulthén

    Es to assess energy cost in children during resting and different physical activities. Methods: Fourteen children, 11-13 yr old, wore the SWA, the IDEEA, and the AR during resting, sitting, stationary bicycling, jumping on a trampoline, playing basketball, stair walking, and walking/running along a 50-m track. The Oxycon Mobile portable metabolic system (VIASYS Healthcare, Conshohocken, PA) was used as the criterion method for energy cost. Results: For resting and sitting, the three activity monitors showed comparable results, but none of them accurately assessed energy cost for stationary bicycling, jumping on a trampoline, or playing basketball. The IDEEA was the only activity monitor that accurately assessed energy cost for stair walking. Also, the IDEEA showed a close estimate of energy cost across the walking and the running intensities, whereas the SWA accurately assessed energy cost for slow to normal walking but showed increased underestimation of energy cost with increasing speed. The AR overestimated energy cost during walking and during slow running but did not respond to increasing running speed. Conclusions: To be able to capture children's physical activity, all three activity monitors need to be further developed. Overall, the IDEEA showed the highest ability to assess energy cost in this study, but SWA may be more feasible for use in children under free-living conditions....


  • Energy Cost of Physical Activities in Children

    by Daniel Arvidsson, Frode Slinde, Sven Larsson, Lena Hulthén

    To examine the validity of SenseWear Pro2 Armband in assessing energy cost of physical activities in children, and to contribute with values of energy costs in an overview of physical activities in children. Energy cost was assessed by SenseWear Pro2 Armband in 20 healthy children, 11-13 yr, while lying down resting, sitting playing games on mobile phone, stepping up and down on a step board, bicycling on a stationary bike, jumping on a trampoline, playing basketball, and walking/running on a treadmill at the speeds 2, 3, 4, 5, 6, 7, 8, and 10 km x h(-1). During these activities, energy cost was also assessed from VO2 and VCO2 measured by Oxycon Mobile portable metabolic system, which was used as criterion method. The difference in energy cost between SenseWear Pro2 Armband and Oxycon Mobile was -0.7 (0.5) (P < 0.001) for resting, -2.0 (0.9) (P < 0.001) for playing games on mobile phone, -6.6 (2.3) (P < 0.001) for stepping on the step board, -12.0 (3.7) (P < 0.001) for bicycling, -2.7 (11.9) (P = 0.34) for jumping on the trampoline, and -14.8 (6.4) kJ x min(-1) (P < 0.001) for playing basketball. The difference in energy cost between SenseWear Pro2 Armband and Oxycon Mobile for increasing treadmill speed was 1.3 (3.1) (P = 0.048), 0.1 (2.9) (P = 0.82), -1.2 (2.6) (P = 0.049), -1.6 (3.2) (P = 0.044), -3.1 (3.7) (P = 0.0013), -4.9 (3.7) (P < 0.001), -5.3 (3.7) (P < 0.001), and -11.1 (3.5) kJ x min(-1) (P < 0.001). SenseWear Pro2 Armband underestimated energy cost of most activities in this study, an underestimation that increased with increased physical activity intensity. A table of energy costs (MET values) of physical activities in children measured by indirect calorimetry is presented as an initiation of the creation of a compendium of physical activities in children.