Paul Metcalfe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul Metcalfe has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
W. H. Ouwehand
University of Cambridge and NHS Blood and Transplant Cambridge, Cambridge, UK
7 shared publicationsC. Kaplan
INTS, Paris, France
4 shared publicationsD. Allen
University of Oxford and NHS Blood and Transplant Oxford, Oxford, UK
4 shared publicationsM. De Haas
Sanquin Research, Amsterdam and Landsteiner Laboratory, Academic Medical Centre, University of Amsterdam, Amsterdam, The Netherlands
4 shared publicationsR. Kekomaki
Finnish Red Cross Blood Service, Helsinki, Finland
4 shared publicationsG. Cavanagh
National Blood Service, Newcastle, UK
2 shared publications
Latest Publications
- 12 January 2009
- Published by Wiley in Vox Sanguinis
- Vol. 96 (2) , 146-152
An International Reference Reagent (minimum sensitivity) for the detection of anti‐human platelet antigen 1a
Background and Objectives The platelet‐specific alloantibody anti‐human platelet antigen (HPA) 1a is involved in feto‐maternal alloimmune thrombocytopenia, post‐transfusion purpura and platelet refractoriness. The existing minimum potency preparation for the detection of anti‐HPA‐1a (NIBSC code 93/710) was established by World Health Organization in 1997 and is used by laboratories to validate new assays or to calibrate ‘in‐house’ controls. However, it has been well‐used and a replacement is required. This report describes the production and comparative evaluation of a freeze‐dried preparation of pooled human plasma, coded 05/106, containing anti‐HPA‐1a.Materials and Methods Plasma containing anti‐HPA‐1a was obtained and 2974 1‐ml aliquots were prepared and freeze‐dried in glass ampoules. In order to characterize the material and compare it to the existing reference material, three collaborative studies were organized, involving a total of 50 different laboratories in 23 countries.Results As expected only anti‐HPA‐1a could be detected in the plasma and no additional HPA or human leucocyte antigen antibodies were detected. When tested in titration, there was a wide variation in the sensitivity of antibody detection by different laboratories, irrespective of the technique used. However, there was no significant difference between the two materials when compared using a t‐test.Conclusions When diluted 1 in 2, most laboratories were able to detect the presence of anti‐HPA‐1a in both materials and the participants agreed that this was an appropriate level to set as the minimum sensitivity required. In October 2007, the World Health Organization Expert Committee on Biological Standardization approved the material 05/106 as an International Reference Reagent.
- 12 January 2009
- Published by Wiley in Vox Sanguinis
- Vol. 96 (2) , 146-152
An International Reference Reagent (minimum sensitivity) for the detection of anti‐human platelet antigen 1a
Background and Objectives The platelet‐specific alloantibody anti‐human platelet antigen (HPA) 1a is involved in feto‐maternal alloimmune thrombocytopenia, post‐transfusion purpura and platelet refractoriness. The existing minimum potency preparation for the detection of anti‐HPA‐1a (NIBSC code 93/710) was established by World Health Organization in 1997 and is used by laboratories to validate new assays or to calibrate ‘in‐house’ controls. However, it has been well‐used and a replacement is required. This report describes the production and comparative evaluation of a freeze‐dried preparation of pooled human plasma, coded 05/106, containing anti‐HPA‐1a.Materials and Methods Plasma containing anti‐HPA‐1a was obtained and 2974 1‐ml aliquots were prepared and freeze‐dried in glass ampoules. In order to characterize the material and compare it to the existing reference material, three collaborative studies were organized, involving a total of 50 different laboratories in 23 countries.Results As expected only anti‐HPA‐1a could be detected in the plasma and no additional HPA or human leucocyte antigen antibodies were detected. When tested in titration, there was a wide variation in the sensitivity of antibody detection by different laboratories, irrespective of the technique used. However, there was no significant difference between the two materials when compared using a t‐test.Conclusions When diluted 1 in 2, most laboratories were able to detect the presence of anti‐HPA‐1a in both materials and the participants agreed that this was an appropriate level to set as the minimum sensitivity required. In October 2007, the World Health Organization Expert Committee on Biological Standardization approved the material 05/106 as an International Reference Reagent.
- 7 December 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 287-288
Ensuring quality in platelet immunology
- 7 December 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 287-288
Ensuring quality in platelet immunology
- 1 November 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 316-324
Interlaboratory variation in the detection of HPA‐specific alloantibodies and in molecular HPA typing
Background and Objectives Platelet immunology quality assurance exercises have been organized by National Institute for Biological Standards and Control since 1991 and, as of 2006, 35 laboratories participate in the serology section. Molecular human platelet antigen (HPA) typing has been included in the exercises since 1998 and, as of 2006, 29 laboratories participate in this part of the exercise. This report details the performance of laboratories in these two areas.Materials and Methods Every 6 months laboratories are sent up to four coded serum/plasma samples for testing in their in‐house assays for HPA antibody detection/identification and four coded whole blood samples to be typed for HPA‐1, ‐2, ‐3 ‐5 and (since 2003) ‐15 by their molecular typing assays (‘genotyping’).Results Fifty‐two sera containing HPA‐specific alloantibodies and 13 sera that were inert, contained only human leucocyte antigen (HLA) class I or high‐titre anti‐A+B antibodies were distributed; 15 sera were issued in more than one exercise. The percentage of participating laboratories that were able to detect HPA‐specific alloantibodies ranged from 15·0 to 100%; the percentage that were able to correctly determine the specificities also ranged from 15·0 to 100%. Over the 20 serology exercises the percentage of laboratories classified as poor performers ranged from 3·1 to 36·7%. A total of 12 780 individual HPA genotyping results were assessed. The overall error rate was 0·7% but there was considerable variation between HPA alleles. Over 11 exercises the percentage of laboratories classified as poor performers varied from 6·3 to 26·3%.Conclusions The ability to detect and to identify platelet‐specific alloantibodies varied widely between laboratories and between various examples of antibodies issued. An increase in the number of laboratories screening for HPA‐15 antibodies was seen, although detection and identification of these antibodies was problematic. The majority of examples of HPA‐3a antibodies and some examples of HPA‐1a and ‐5b were also difficult to detect and identify. In addition, this scheme has shown that despite the apparent reliability of molecular typing techniques, mistakes do occur, particularly with certain systems. Approximately one in five laboratories participating in the serology exercises and one in seven participating in the genotyping exercises were classified as poor performer at one point or more during the series of exercises.
- 1 November 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 316-324
Interlaboratory variation in the detection of HPA‐specific alloantibodies and in molecular HPA typing
Background and Objectives Platelet immunology quality assurance exercises have been organized by National Institute for Biological Standards and Control since 1991 and, as of 2006, 35 laboratories participate in the serology section. Molecular human platelet antigen (HPA) typing has been included in the exercises since 1998 and, as of 2006, 29 laboratories participate in this part of the exercise. This report details the performance of laboratories in these two areas.Materials and Methods Every 6 months laboratories are sent up to four coded serum/plasma samples for testing in their in‐house assays for HPA antibody detection/identification and four coded whole blood samples to be typed for HPA‐1, ‐2, ‐3 ‐5 and (since 2003) ‐15 by their molecular typing assays (‘genotyping’).Results Fifty‐two sera containing HPA‐specific alloantibodies and 13 sera that were inert, contained only human leucocyte antigen (HLA) class I or high‐titre anti‐A+B antibodies were distributed; 15 sera were issued in more than one exercise. The percentage of participating laboratories that were able to detect HPA‐specific alloantibodies ranged from 15·0 to 100%; the percentage that were able to correctly determine the specificities also ranged from 15·0 to 100%. Over the 20 serology exercises the percentage of laboratories classified as poor performers ranged from 3·1 to 36·7%. A total of 12 780 individual HPA genotyping results were assessed. The overall error rate was 0·7% but there was considerable variation between HPA alleles. Over 11 exercises the percentage of laboratories classified as poor performers varied from 6·3 to 26·3%.Conclusions The ability to detect and to identify platelet‐specific alloantibodies varied widely between laboratories and between various examples of antibodies issued. An increase in the number of laboratories screening for HPA‐15 antibodies was seen, although detection and identification of these antibodies was problematic. The majority of examples of HPA‐3a antibodies and some examples of HPA‐1a and ‐5b were also difficult to detect and identify. In addition, this scheme has shown that despite the apparent reliability of molecular typing techniques, mistakes do occur, particularly with certain systems. Approximately one in five laboratories participating in the serology exercises and one in seven participating in the genotyping exercises were classified as poor performer at one point or more during the series of exercises.
- 1 November 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 309-315
Collaborative studies to establish the first World Health Organization International Standard for detection of human antibody against human platelet antigen‐3a
Background and Objectives The platelet‐specific antibody anti‐human platelet antigen‐3a (anti‐HPA‐3a) is involved in neonatal alloimmune thrombocytopenia, post‐transfusion purpura, and platelet refractoriness. However, HPA‐3a antibodies are often difficult to detect, probably because the antigen is labile. This report describes the production of a freeze‐dried preparation of pooled human plasma, coded 03/190, containing IgG antibodies against the HPA‐3a. The material is intended for use as a minimum sensitivity reagent in glycoprotein‐specific assays currently used for anti‐HPA‐3a detection. Laboratories can use it to assess the sensitivity of their ‘in‐house’ assays for anti‐HPA‐3a and to calibrate local controls for routine use in each batch of tests.Materials and Methods Plasma containing anti‐HPA‐3a was obtained from a mother of two babies both born with severe thrombocytopenia, and following dilution it was freeze dried in glass ampoules.Results Two collaborative studies demonstrated that the candidate material contained anti‐HPA‐3a and human leucocyte antigen (HLA) class I antibodies, but no other HPA antibodies that might confuse the detection of the anti‐HPA‐3a. The minimum dilution that should give a positive result was determined to be 1 : 8 by two further international collaborative studies involving a total of 49 laboratories in 23 countries.Conclusion The material also contains HLA antibodies and is suitable for use only in techniques that are glycoprotein specific (i.e. monoclonal antibody immobilization of platelet antigens and enzyme‐linked immunosorbent assay) where only HPA antibodies will be detected. This standard will allow laboratories to measure their sensitivity of detection of anti‐HPA‐3a and will also allow those laboratories with relatively insensitive techniques to monitor their performance as they improve their methodology.
- 1 November 2007
- Published by Wiley in Vox Sanguinis
- Vol. 93 (4) , 309-315
Collaborative studies to establish the first World Health Organization International Standard for detection of human antibody against human platelet antigen‐3a
Background and Objectives The platelet‐specific antibody anti‐human platelet antigen‐3a (anti‐HPA‐3a) is involved in neonatal alloimmune thrombocytopenia, post‐transfusion purpura, and platelet refractoriness. However, HPA‐3a antibodies are often difficult to detect, probably because the antigen is labile. This report describes the production of a freeze‐dried preparation of pooled human plasma, coded 03/190, containing IgG antibodies against the HPA‐3a. The material is intended for use as a minimum sensitivity reagent in glycoprotein‐specific assays currently used for anti‐HPA‐3a detection. Laboratories can use it to assess the sensitivity of their ‘in‐house’ assays for anti‐HPA‐3a and to calibrate local controls for routine use in each batch of tests.Materials and Methods Plasma containing anti‐HPA‐3a was obtained from a mother of two babies both born with severe thrombocytopenia, and following dilution it was freeze dried in glass ampoules.Results Two collaborative studies demonstrated that the candidate material contained anti‐HPA‐3a and human leucocyte antigen (HLA) class I antibodies, but no other HPA antibodies that might confuse the detection of the anti‐HPA‐3a. The minimum dilution that should give a positive result was determined to be 1 : 8 by two further international collaborative studies involving a total of 49 laboratories in 23 countries.Conclusion The material also contains HLA antibodies and is suitable for use only in techniques that are glycoprotein specific (i.e. monoclonal antibody immobilization of platelet antigens and enzyme‐linked immunosorbent assay) where only HPA antibodies will be detected. This standard will allow laboratories to measure their sensitivity of detection of anti‐HPA‐3a and will also allow those laboratories with relatively insensitive techniques to monitor their performance as they improve their methodology.
- 4 August 2005
- Published by Wiley in Vox Sanguinis
- Vol. 89 (2) , 100-104
Collaborative study to establish the first international standard for quantitation of anti‐HPA‐1a
Background and Objectives This report describes the production of a freeze‐dried preparation of pooled human plasma, containing immunoglobulin G (IgG) antibodies against the human platelet antigen 1a (HPA‐1a). The material, coded 03/152, is proposed as an International Standard containing 100 arbitrary units of anti‐HPA‐1a for use in quantitative assays to determine the anti‐HPA‐1a activity in clinical samples. Materials and Methods Plasma samples containing potent anti‐HPA‐1a were pooled and freeze dried in 1‐ml ampoules. In addition, three individual plasma samples were selected which had varying levels of anti‐HPA‐1a activity. The anti‐HPA‐1a activity of these three samples was determined by using a variety of quantitative assays with the proposed standard as a reference. Results An international collaborative study, which was part of the 2004 ISBT Platelet Immunology Workshop, involved 39 laboratories in 24 countries and showed that the anti‐HPA‐1a activity in three test samples could be reliably determined by using the proposed standard. Conclusions Laboratories can use this standard to measure the anti‐HPA‐1a activity in patient's samples. Further studies are required to determine the relationship between anti‐HPA‐1a activity and clinical outcome in patients with neonatal alloimmune thrombocytopenia (NAIT).
- 4 August 2005
- Published by Wiley in Vox Sanguinis
- Vol. 89 (2) , 100-104
Collaborative study to establish the first international standard for quantitation of anti‐HPA‐1a
Background and Objectives This report describes the production of a freeze‐dried preparation of pooled human plasma, containing immunoglobulin G (IgG) antibodies against the human platelet antigen 1a (HPA‐1a). The material, coded 03/152, is proposed as an International Standard containing 100 arbitrary units of anti‐HPA‐1a for use in quantitative assays to determine the anti‐HPA‐1a activity in clinical samples. Materials and Methods Plasma samples containing potent anti‐HPA‐1a were pooled and freeze dried in 1‐ml ampoules. In addition, three individual plasma samples were selected which had varying levels of anti‐HPA‐1a activity. The anti‐HPA‐1a activity of these three samples was determined by using a variety of quantitative assays with the proposed standard as a reference. Results An international collaborative study, which was part of the 2004 ISBT Platelet Immunology Workshop, involved 39 laboratories in 24 countries and showed that the anti‐HPA‐1a activity in three test samples could be reliably determined by using the proposed standard. Conclusions Laboratories can use this standard to measure the anti‐HPA‐1a activity in patient's samples. Further studies are required to determine the relationship between anti‐HPA‐1a activity and clinical outcome in patients with neonatal alloimmune thrombocytopenia (NAIT).
- 6 April 2005
- Published by Wiley in Transfusion
- Vol. 45 (5) , 654-659
Microarray‐based genotyping for blood groups: comparison of gene array and 5′‐nuclease assay techniques with human platelet antigen as a model
BACKGROUND: Most blood group alloantigens specific for red cells and platelets (PLTs) are based on single‐nucleotide polymorphisms (SNPs) in genes encoding relevant membrane proteins.STUDY DESIGN AND METHODS: By use of five human PLT antigen (HPA) systems as a model, the suitability of a fourth‐generation microarray technique for SNP typing was investigated. The results of the former were compared with those of a parallel developed third‐generation technique (TaqMan assay, Applied Biosystems). Both techniques were validated by use of a unique panel of 71 blinded DNA samples containing at least 15 aa, bb, and ab genotypes for the HPA‐1, ‐2, ‐3, ‐5, and‐15 systems.RESULTS: Unambiguous and concordant results were obtained with both techniques for all samples.CONCLUSION: The data presented here validate the use of microarray for large‐scale SNP typing for clinically relevant blood group alloantigens.
- 6 April 2005
- Published by Wiley in Transfusion
- Vol. 45 (5) , 654-659
Microarray‐based genotyping for blood groups: comparison of gene array and 5′‐nuclease assay techniques with human platelet antigen as a model
BACKGROUND: Most blood group alloantigens specific for red cells and platelets (PLTs) are based on single‐nucleotide polymorphisms (SNPs) in genes encoding relevant membrane proteins.STUDY DESIGN AND METHODS: By use of five human PLT antigen (HPA) systems as a model, the suitability of a fourth‐generation microarray technique for SNP typing was investigated. The results of the former were compared with those of a parallel developed third‐generation technique (TaqMan assay, Applied Biosystems). Both techniques were validated by use of a unique panel of 71 blinded DNA samples containing at least 15 aa, bb, and ab genotypes for the HPA‐1, ‐2, ‐3, ‐5, and‐15 systems.RESULTS: Unambiguous and concordant results were obtained with both techniques for all samples.CONCLUSION: The data presented here validate the use of microarray for large‐scale SNP typing for clinically relevant blood group alloantigens.
- 30 September 2003
- Published by Wiley in Vox Sanguinis
- Vol. 85 (3) , 240-245
Nomenclature of human platelet antigens
- 30 September 2003
- Published by Wiley in Vox Sanguinis
- Vol. 85 (3) , 240-245
Nomenclature of human platelet antigens
- 2 April 2003
- Published by Wiley in Vox Sanguinis
- Vol. 84 (3) , 237-240
Collaborative studies to establish the first WHO Reference Reagent for detection of human antibody against human platelet antigen‐5b
Background and Objectives This report describes the production of a freeze‐dried preparation of pooled human plasma, coded 99/666, containing immunoglobulin G (IgG) antibodies against human platelet antigen 5b (HPA‐5b). Materials and Methods The material is intended for use as a minimum sensitivity reagent in the assays currently used for detection of antibodies to HPA‐5b. Laboratories can use it to assess the sensitivity of their ‘in‐house’ assays for antibodies to HPA‐5b and to calibrate local controls for routine use in each batch of tests. Results Two collaborative studies demonstrated that the two candidate materials contained antibodies to HPA‐5b and that there were no other HPA or human leucocyte antigen (HLA) antibodies which might confuse the detection of antibodies to HPA‐5b. The two samples were pooled and freeze‐dried in 1‐ml ampoules. Conclusions The minimum dilution of the antibody against 5b required to yield a positive result was determined, by two international collaborative studies involving a total of 49 laboratories in 26 countries, to be 1 in 2.
- 2 April 2003
- Published by Wiley in Vox Sanguinis
- Vol. 84 (3) , 237-240
Collaborative studies to establish the first WHO Reference Reagent for detection of human antibody against human platelet antigen‐5b
Background and Objectives This report describes the production of a freeze‐dried preparation of pooled human plasma, coded 99/666, containing immunoglobulin G (IgG) antibodies against human platelet antigen 5b (HPA‐5b). Materials and Methods The material is intended for use as a minimum sensitivity reagent in the assays currently used for detection of antibodies to HPA‐5b. Laboratories can use it to assess the sensitivity of their ‘in‐house’ assays for antibodies to HPA‐5b and to calibrate local controls for routine use in each batch of tests. Results Two collaborative studies demonstrated that the two candidate materials contained antibodies to HPA‐5b and that there were no other HPA or human leucocyte antigen (HLA) antibodies which might confuse the detection of antibodies to HPA‐5b. The two samples were pooled and freeze‐dried in 1‐ml ampoules. Conclusions The minimum dilution of the antibody against 5b required to yield a positive result was determined, by two international collaborative studies involving a total of 49 laboratories in 26 countries, to be 1 in 2.
- Open Access
- 3 July 2002
- Published by Wiley in Vox Sanguinis
- Vol. 83 (1) , 1-12
Genotyping for platelet‐specific antigens: techniques for the detection of single nucleotide polymorphisms
Accurate typing of patients for platelet‐specific (human platelet) antigens (HPA) is required in several different clinical situations, and blood services need to maintain panels of HPA‐typed apheresis platelet donors and whole‐blood donors to support HPA alloimmunized patients. Six clinically relevant HPA alloantigen systems have been described and, in addition, a significant number of HPA alloantigens with a highly skewed allele frequency or of very low immunogenicity have been reported. Certain well‐characterized biallelic systems such as Gov have not as yet been included in the HPA nomenclature but are included in this review. Biochemical studies have identified the platelet membrane proteins on which the HPA antigens are localized. Cloning of the genes encoding these proteins and the realization that there is adequate mRNA in fresh platelets has led to identification of the molecular basis of HPA antigens over the last decade. All but one of the biallelic platelet‐specific alloantigen systems are based on a single nucleotide polymorphism in the DNA sequence, corresponding to a single amino acid substitution in the encoded primary protein sequence. The discovery of the genetic basis of the alloantigens has allowed the development of polymerase chain reaction‐based techniques for HPA genotyping using genomic DNA. The genetic basis of the HPA alloantigens, the most commonly used genome typing techniques and their pitfalls, and future developments, are discussed in this review.
- 3 July 2002
- Published by Wiley in Vox Sanguinis
- Vol. 83 (1) , 1-12
Open AccessGenotyping for platelet‐specific antigens: techniques for the detection of single nucleotide polymorphisms
Accurate typing of patients for platelet‐specific (human platelet) antigens (HPA) is required in several different clinical situations, and blood services need to maintain panels of HPA‐typed apheresis platelet donors and whole‐blood donors to support HPA alloimmunized patients. Six clinically relevant HPA alloantigen systems have been described and, in addition, a significant number of HPA alloantigens with a highly skewed allele frequency or of very low immunogenicity have been reported. Certain well‐characterized biallelic systems such as Gov have not as yet been included in the HPA nomenclature but are included in this review. Biochemical studies have identified the platelet membrane proteins on which the HPA antigens are localized. Cloning of the genes encoding these proteins and the realization that there is adequate mRNA in fresh platelets has led to identification of the molecular basis of HPA antigens over the last decade. All but one of the biallelic platelet‐specific alloantigen systems are based on a single nucleotide polymorphism in the DNA sequence, corresponding to a single amino acid substitution in the encoded primary protein sequence. The discovery of the genetic basis of the alloantigens has allowed the development of polymerase chain reaction‐based techniques for HPA genotyping using genomic DNA. The genetic basis of the HPA alloantigens, the most commonly used genome typing techniques and their pitfalls, and future developments, are discussed in this review.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 77 (1) , 40-43
HPA Genotyping by PCR–SSP: Report of 4 Exercises
Polymerase chain reaction with sequence specific primers (PCR-SSP) is widely used for the determination of the alleles encoding the human platelet antigens (HPA)-1 to 5. In order to evaluate and improve performance with this technique, four exercises were organised during 1996-1998. Coded DNA samples were distributed from the National Institute for Biological Standards and Control (NIBSC) as follows: exercise one, 18 samples; two, 12 samples; three, 6 samples, and four, 4 samples. Performance improved over the four exercises following the adoption of a consensus protocol and the re-design of one primer. The percentage of incorrect results in each exercise was as follows: exercise one, 9%; two 3.2%, three, 0.8%, and four, 0.3%. The modified PCR-SSP protocol is a reliable method for genotyping HPA-1 to 5 in reference laboratories. DNA-based HPA genotyping has an important role in platelet immunology and further exercises will be included in the bi-annual platelet immunology exercises organised by NIBSC.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 77 (1) , 40-43
HPA Genotyping by PCR–SSP: Report of 4 Exercises
Polymerase chain reaction with sequence specific primers (PCR-SSP) is widely used for the determination of the alleles encoding the human platelet antigens (HPA)-1 to 5. In order to evaluate and improve performance with this technique, four exercises were organised during 1996-1998. Coded DNA samples were distributed from the National Institute for Biological Standards and Control (NIBSC) as follows: exercise one, 18 samples; two, 12 samples; three, 6 samples, and four, 4 samples. Performance improved over the four exercises following the adoption of a consensus protocol and the re-design of one primer. The percentage of incorrect results in each exercise was as follows: exercise one, 9%; two 3.2%, three, 0.8%, and four, 0.3%. The modified PCR-SSP protocol is a reliable method for genotyping HPA-1 to 5 in reference laboratories. DNA-based HPA genotyping has an important role in platelet immunology and further exercises will be included in the bi-annual platelet immunology exercises organised by NIBSC.