  • Biocompatibility and mechanical properties of diamond‐like coatings on cobalt‐chromium‐molybdenum steel and titanium‐aluminum‐vanadium biomedical alloys

    by C. Hinüber, C. Kleemann, R. J. Friederichs, L. Haubold, H. J. Scheibe, T. Schuelke, C. Boehlert, M. J. Baumann

    Diamond‐like carbon (DLC) films are favored for wear components because of diamond‐like hardness, low friction, low wear, and high corrosion resistance (Schultz et al., Mat‐wiss u Werkstofftech 2004;35:924–928; Lappalainen et al., J Biomed Mater Res B Appl Biomater 2003;66B:410–413; Tiainen, Diam Relat Mater 2001;10:153–160). Several studies have demonstrated their inertness, nontoxicity, and the biocompatibility, which has led to interest among manufacturers of surgical implants (Allen et al., J Biomed Mater Res B Appl Biomater 2001;58:319–328; Uzumaki et al., Diam Relat Mater 2006;15:982–988; Hauert, Diam Relat Mater 2003;12:583–589; Grill, Diam Relat Mater 2003;12:166–170). In this study, hydrogen‐free amorphous, tetrahedrally bonded DLC films (ta‐C) were deposited at low temperatures by physical vapor deposition on medical grade Co28Cr6Mo steel and the titanium alloy Ti6Al4V (Scheibe et al., Surf Coat Tech 1996;85:209–214). The mechanical performance of the ta‐C was characterized by measuring its surface roughness, contact angle, adhesion, and wear behavior, whereas the biocompatibility was assessed by osteoblast (OB) attachment and cell viability via Live/Dead assay. There was no statistical difference found in the wettability as measured by contact angle measurements for the ta‐C coated and the uncoated samples of either Co28Cr6Mo or Ti6Al4V. Rockwell C indentation and dynamic scratch testing on 2–10 μm thick ta‐C films on Co28Cr6Mo substrates showed excellent adhesion with HF1 grade and up to 48 N for the critical load LC2 during scratch testing. The ta‐C coating reduced the wear from 3.5 × 10−5 mm3/Nm for an uncoated control sample (uncoated Co28Cr6Mo against uncoated stainless steel) to 1.1 × 10−7 mm3/Nm (coated Co28Cr6Mo against uncoated stainless steel) in reciprocating pin‐on‐disk testing. The lowest wear factor of 3.9 × 10−10 mm3/Nm was measured using a ta‐C coated steel ball running against a ta‐C coated and polished Co28Cr6Mo disk. Student's t‐test found that the ta‐C coating had no statistically significant (p < 0.05) effect on OB attachment, when compared with the uncoated control samples. There was no significant difference (p < 0.05) in the Live/Dead assay results in cell death between the ta‐C coated Co28Cr6Mo and Ti6Al4V samples and the uncoated controls. Therefore, these ta‐C coatings show improved wear and corrosion (Dorner‐Reisel et al., Diam Relat Mater 2003;11:823–827; Affato et al., J Biomed Mater Res B Appl Biomater 2000;53:221–226; Dorner‐Reisel et al., Surf Coat Tech 2004;177–178:830–837; Kim et al., Diam Relat Mater 2004;14:35–41) performance and excellent in vitro cyto‐compatibility, when compared with currently used uncoated Co28Cr6Mo and Ti6Al4V implant materials. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.


  • AFM and SEM characterization of iron oxide coated ceramic membranes

    by B. S. Karnik, M. J. Baumann, S. J. Masten, S. H. Davies


  • Confocal laser scanning microscopy as a tool for imaging cancellous bone

    by I. O. Smith, F. Ren, M. J. Baumann, E. D. Case

    Understanding the bimodal structure of cancellous bone is important for tissue engineering in order to more accurately fabricate scaffolds to promote bone ingrowth and vascularization in newly forming bone. In this study, confocal laser scanning microscopy (CLSM) was used to create detailed images of the bimodally porous intertrabecular space of defatted and deproteinized cancellous canine bone taken from the epiphysis of the humerus. The bimodal pore structure was imaged using both reflective and fluorescent modes in CLSM, resulting in four different, but complementary image types: (1) a Z‐stack overlay, (2) a ϕ–Z scan, (3) a topographical map, and (4) a contour map. Submerging the bone in rhodamine B dye prior to fluorescent imaging enhanced the pore surface details, giving a more accurate pore size measurement. The average macropore diameter was found to be 260 ± 97 μm while the average micropore diameter was 13 ± 10 μm. When compared with common techniques, including microcomputed tomography, magnetic resonance imaging, scanning electron microscopy, and environmental scanning electron microscopy, for imaging cancellous bone, CLSM was found to be an effective tool, given its ability to nondestructively image the surface and near‐surface pore structure. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006


  • Open Access

    MC3T3-E1 osteoblast attachment and proliferation on porous hydroxyapatite scaffolds fabricated with nanophase powder

    by Ian O Smith, Laura R McCabe, Melissa J Baumann

    Porous bone tissue engineering scaffolds were fabricated using both nano hydroxyapatite (nano HA) powder (20 nm average particle size) and micro HA powder (10 microm average particle size), resulting in sintered scaffolds of 59 vol% porosity and 8.6 +/- 1.9 microm average grain size and 72 vol% porosity and 588 +/- 55nm average grain size, respectively. Scanning electron microscopy was used to measure both the grain size and pore size. MC3T3-E1 osteoblast (OB) attachment and proliferation on both nano HA and micro HA porous scaffolds were quantified. As expected, OB cell number was greater on nano HA scaffolds compared with similarly processed micro HA scaffolds 5 days after seeding, while OB attachment did not appear greater on the nano HA scaffolds (p < 0.05).


  • Surface potential and osteoblast attraction to calcium phosphate compounds is affected by selected alkaline hydrolysis processing

    by I. O. Smith, M. J. Baumann, L. Obadia, J.-M. Bouler

    This study examines the link(s) between the suspension behavior of calcium deficient apatites (CDAs) and biphasic calcium phosphate (BCP), as measured by the ζ-potential, with respect to both whole bone and osteoblasts. CDA is fabricated by hydrolyzing an acidic CaP such as dicalcium diphosphate dihydrate (DCPD; CaHPO4·2H2O) and has a structure and composition close to bone apatite. Sintering CDA results in the formation of BCP ceramics consisting of mixtures of hydroxyapatite (HA) and beta-tricalcium phosphate (β-TCP), with the HA/β-TCP weight ratio proportional to the Ca/P ratio of CDA. The choice of the base for the DCPD hydrolysis allows various ionic partial substitution of the formed CDA. Na for Ca partial substitution is of interest because of the resulting improvement in mechanical properties of the resulting BCP ceramics and NH4OH was used as a negative control. The ζ-potential was measured for these materials and the stability of the ceramic to bone interaction calculated. ζ-potential values decrease for CDA(NH4OH) versus CDA(NaOH) and increase for BCP(NH4OH) versus BCP(NaOH). While results of these analyses indicate that NH4OH and NaOH processed CDA and BCP will likely yield osteoblast attachment in vivo, differences in the ζ-potentials may explain varying degrees of cell attachment.


  • Electrostatic interactions as a predictor for osteoblast attachment to biomaterials

    by I. O. Smith, M. J. Baumann, L. R. McCabe

    The present study utilizes zeta (ζ)‐potential analysis as an indicator of bonding of osteoblasts and whole bone to various biomaterials. Common metal alloys (316L stainless steel, CoCrMo, and Ti6Al4V) and bioceramics (hydroxyapatite and β‐tricalcium phosphate) used in orthopedic applications were suspended in particulate form in physiologic saline, both as‐received and supplemented with bovine serum albumin (BSA). Metal alloys were also treated with NaOH washing to study the effect of such a surface treatment on the ζ‐potential. The NaOH wash was found to increase the ζ‐potential for CoCrMo and Ti6Al4V, but there was a decrease in the magnitude of the ζ‐potential for 316L stainless steel. When the metal alloy powders were suspended in BSA‐supplemented physiologic saline, the ζ‐potential as a function of pH increased, thereby increasing the electronegativity gap and increasing the propensity for bonding between each of the metal alloys and bone. This increase is likely due to matrix proteins in the BSA, which adsorb onto the metal alloy surfaces, promoting bone growth. With the addition of BSA to each bioceramic system, a uniform decrease in ζ‐potential was observed. However, the electronegativity gap remained large in each case, maintaining the anticipation of bonding. ζ‐Potential analysis is an effective predictor of biomaterial attraction to osteoblasts and bone, providing a useful in vitro method for predicting such interactions. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 436–441, 2004