RVRasik B. Vajpayee

Rasik B. Vajpayee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rasik B. Vajpayee has a total of 108 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A 2026 Update in DSEK Graft Delivery Techniques and Devices

    by Bhavana Sharma, Brindha Periasamy, Pranita Sahay, Priyanka Priyanka, Radhika Tandon, Rasik B. Vajpayee

    Purpose: Corneal transplantation has evolved from penetrating keratoplasty to selective component keratoplasty, with endothelial keratoplasty (EK) becoming the preferred treatment for most endothelial disorders. EK offers faster visual rehabilitation, reduced immunologic rejection, and longer graft survival. This review intends to describe various Descemet stripping endothelial keratoplasty (DSEK) graft insertion techniques and devices, clinical outcomes, and surgical ease, to facilitate evidence-based technique selection. Methods: This review critically appraises graft insertion techniques and devices used in DSEK. The available literature was analyzed with respect to techniques, instrumentation, endothelial cell loss, complications, and visual outcomes. The same is described in a clinical context in a comparative model. Results: Busin glide is the most commonly used method for DSEK graft insertion, followed by the needle insertion technique. Most DSEK graft insertion techniques have been classified into pull-through and push-through. Pull-through techniques are associated with lower endothelial cell loss, quicker graft unfolding, and improved apposition, particularly useful for younger donor tissues with tighter scrolls, however, with some risk of graft slippage or inversion during insertion. Push-through techniques require smaller incisions, use specialized injectors to enable controlled graft delivery, but may be associated with complications such as graft dislocation, extrusion, or mechanical injury related to passage through narrow lumen. Conclusions: Current evidence does not support the superiority of any single technique across all outcome measures, as robust comparative and long-term data remain limited. Ultimately, technique and device selection are guided by surgeon preference, donor tissue characteristics, and the clinical context.


  • Corneal transplantation triple procedures

    by Sridevi Nair, Rashmi Deshmukh, Shalini Mohan, Tushar Agarwal, Namrata Sharma, Rasik B. Vajpayee


  • Shaped corneal transplantation surgery

    by Pranita Sahay, Louis Julian Stevenson, Tushar Agarwal, Bhavana Sharma, Namrata Sharma, Rasik B Vajpayee

    Since its inception in 1905, keratoplasty techniques have continuously evolved. Shaped keratoplasty procedures have allowed corneal surgeons to use complex graft–host junctions and non-circular graft designs to optimise wound strength and healing, facilitate early suture removal and expedite visual rehabilitation. While this was initially limited to penetrating procedures, shaped lamellar keratoplasty techniques have since emerged. Furthermore, the arrival of femtosecond laser has dramatically increased the range of graft designs available to surgeons, due to the technology’s ability to precisely cut complex wound edges. This review describes the broad range of shaped keratoplasty grafts currently available and elaborates on their respective advantages and disadvantages in relation to conventional keratoplasty.


  • Open Access

    Comparative Evaluation Of Clinical Characteristics And Visual Outcomes Of Traumatic And Non-Traumatic Graft Dehiscence Following Corneal Transplantation Surgery

    by Louis J Stevenson, Robin G Abell, Myra B McGuinness, Rasik B Vajpayee

    Purpose: To compare patient demographics, clinical associations and visual outcomes between traumatic and non-traumatic wound dehiscence, following corneal transplantation. Methods: Retrospective review of all patients presenting with post-keratoplasty wound dehiscence to the Royal Victorian Eye and Ear Hospital between January 2005 and December 2017. Patients with wound dehiscence following keratoplasty of any cause were included. Results: Of 71 eyes from 71 patients included, 60 (85%) were penetrating keratoplasty patients. The mean age was 56.4 years (SD=22.7, range 17.6–97) and 62% (n = 44) of patients were male. There were 28 (39%) cases of traumatic dehiscence and 43 (61%) cases of non-traumatic dehiscence. The median time interval from keratoplasty to dehiscence was significantly less in non-traumatic patients than traumatic patients (0.2 years, IQR 0.1–2.0 vs 2.3 years, IQR 0.3–14.8, p=0.01). There was no significant difference in best-corrected visual acuity at 6 months between traumatic and non-traumatic dehiscence (6/60 vs 6/36, p=0.62), suture technique (continuous vs interrupted, p=0.12), or graft type (penetrating keratoplasty vs deep anterior lamellar keratoplasty) after adjusting for keratoconus (p=0.41). Conclusion: Post-keratoplasty wound dehiscence is a serious complication and can cause significant loss of vision. While the risk of dehiscence is lifelong, the first 3 years post-keratoplasty carry the highest risk, with non-traumatic dehiscence tending to occur earlier than traumatic dehiscence.


  • Intraocular pressure measurement after corneal transplantation

    by Bernardo de Padua Soares Bezerra, Elsie Chan, Rahul Chakrabarti, Rasik B. Vajpayee


  • Open Access

    Postoperative detection of unusual pathology in donor corneal tissue

    by Rasik B Vajpayee, Louis J Stevenson, Graeme Pollock

    We present a series of three patients with previously undetected corneal pathology in grafted corneal tissue following keratoplasty for keratoconus. Postoperatively, a faint layer of anterior stromal haze involving the graft was observed in each patient upon slit lamp examination. Anterior segment optical coherence tomography (AS-OCT) confirmed the presence of anterior stromal scarring across the transplanted cornea. However, the ocular and systemic medical histories of the donors were unremarkable. As the suboptimal donor corneal tissue may escape the standard screening protocols, eye banks should consider adding AS-OCT imaging for screening donor corneal tissue before transplantation.


  • Open Access

    Techniques of anterior capsulotomy in cataract surgery

    by Rasik B Vajpayee, Bhavana Sharma, Robin G Abell, Tarun Arora, Tom Antony

    Optimal outcomes of a cataract surgery largely depend on the successful performance of an anterior capsulotomy. It is one of the most important steps of modern cataract surgery which reduces the risk of capsular tears and ensures postoperative stable intraocular lens (IOL). Anterior capsulotomy is considered ideal if it is round, continuous, well-centered, and overlaps the implanted IOL around its circumference. If any of these features is missing, it can be a cause of impedance for desired surgical and visual outcomes. Manual can opener and manual capsulorhexis are the routine standard techniques employed for manual extracapsular cataract extraction and phacoemulsification, respectively. Recent increasing use of femtosecond laser cataract surgery has allowed cataract surgeons to obviate inherent inaccuracies of manual anterior capsulotomy techniques. There is an ongoing quest to find an ideal, risk free, and surgeon-friendly technique of anterior capsulotomy that can be employed for surgery in all types of cataracts.


  • Surgical management of peripheral corneal thinning disorders

    by Monica Lohchab, Gaurav Prakash, Tarun Arora, Prafulla Maharana, Vishal Jhanji, Namrata Sharma, Rasik B. Vajpayee


  • Open Access

    Amniotic membrane transplantation with or without autologous cultivated limbal stem cell transplantation for the management of partial limbal stem cell deficiency

    by Namrata Sharma, Sujata Mohanty, Vishal Jhanji, Rasik B. Vajpayee

    Purpose: To compare the outcomes of amniotic membrane transplantation (AMT) vs cultivated limbal stem cell transplantation (LSCT) in eyes with partial limbal stem cell deficiency (LSCD) following chemical burns. Methods: Eyes with unilateral partial LSCD (≤180° involvement) were randomized in two groups to undergo either pannus resection combined with AMT or pannus resection combined with LSCT in a tertiary eye care hospital. Primary outcome measures were time to corneal epithelialization and absence of conjunctivalization of the cornea. Patients were followed up at 1 week, 1, 3, 6, and 12 months after the surgical procedure. Results: There was no difference between mean age (30.85±5.8 vs 28.64±6.4 years, P=0.40) and sex distribution of patients between the two groups at baseline. Mean time to corneal epithelialization was 10.45±5.8 days in the AMT group and 11±3.9 days in the LSCT group (P=0.43). At the end of 1 year, there was no significant difference between the degree of conjunctivalization of cornea, (P=0.06) corneal vascularization, (P=0.08), and clarity (P=0.07) in both groups. Conclusion: Our study showed that AMT alone is a useful therapeutic modality in cases with partial LSCD due to ocular chemical injury. Stem cell transplantation may not be required in these cases.


  • Open Access

    Bowman’s layer transplantation: evidence to date

    by Bhavana Sharma, Aditi Dubey, Gaurav Prakash, Rasik B Vajpayee

    Surgical management of keratoconus (KC) has undergone a paradigm shift in the last two decades and component corneal transplantation technique of deep anterior lamellar keratoplasty has established itself as a modality of choice for management of advanced cases of KC. Every now and then, new minimalist modalities are being innovated for the management of KC. On the same lines, a new technique, Bowman’s layer transplantation, for surgical management of moderate to advanced KC has been reported in recent years. The procedure has shown to be beneficial in reducing ectasia in advanced KC with minimal intraoperative and postoperative complications. In this review, we intend to describe available information and literature with reference to this new surgical technique – Bowman’s layer transplantation.