SGShan Gao

Shan Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shan Gao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Yongsheng Liu

    State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, PR China

    5 shared publications
  • Zhaochu Hu

    State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, PR China

    5 shared publications
  • Ming Li

    State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, PR China

    3 shared publications
  • Haihong Chen

    State Key Laboratory of Geological Processes and Mineral Resources, Faculty of Earth Sciences, China University of Geosciences, Wuhan, 430074, PR China

    2 shared publications
  • Shenghong Hu

    State Key Laboratory of Geological Processes and Mineral Resources, Faculty of Earth Sciences, China University of Geosciences, Wuhan, 430074, PR China

    2 shared publications
  • Honglin Yuan

    State Key Laboratory of Continental Dynamics, Department of Geology, Northwest University, Xi'an, PR China

    1 shared publication

Latest Publications

  • Contrasting matrix induced elemental fractionation in NIST SRM and rock glasses during laser ablation ICP-MS analysis at high spatial resolution

    by Zhaochu Hu, Yongsheng Liu, Lu Chen, Lian Zhou, Ming Li, Keqing Zong, Lvyun Zhu, Shan Gao

    The greatest strength of the LA-ICP-MS technique is its application to microsampling in which extremely small pits are obtained. The results of this study highlight some significant different laser-induced fractionations between widely used external reference materials NIST SRM 610–614 and natural silicate reference materials (e.g., USGS reference glasses (GSE-1G, GSD-1G), MPI-DING glasses, USGS basalt glasses and zircon reference material GJ-1) at high spatial resolution analysis. For the sample matrices and analytical conditions used in this study, the laser-induced elemental fractionations for 63 selected isotopes are negligible at the spot sizes of 160–44 µm. However, the laser-induced elemental fractionations of Li, Na, Si, K, V, Cr, Mn, Fe, Co, Ni, Cu, Rb, Cs and U (with respect to Ca) increase significantly with decreasing spot sizes from 44 µm to 32 µm, 24 µm and 16 µm in these natural silicate reference materials. Unlike in these sample matrices, laser-induced elemental fractionations of these elements in NIST SRM 610–614 are unique in that they are almost not affected by the change of spot sizes from 44 to 32 to 24 µm, with only slight increase at the spot sizes of 16 µm. The much less significant laser-induced elemental fractionation in NIST SRM 61X in comparison with other natural silicate materials makes them not ideal as external reference materials at high spatial resolution analysis. Alternatively, this NIST SRM 61X-specific matrix effect for Li, Na, K, V, Cr, Mn, Fe, Co, Ni, Cu, Rb, Cs and U can be minimized by using Si for internal standardization. U and Pb in zircon GJ-1 are exceptions, which are zircon-specific.


  • Direct Quantitative Determination of Trace Elements in Fine‐Grained Whole Rocks by Laser Ablation‐Inductively Coupled Plasma‐Mass Spectrometry

    by Ming Li, Zhaochu Hu, Shan Gao, Yongsheng Liu

    Previous laser ablation‐ICP‐MS bulk analyses have been confined to volcanic glasses and glass disks or powder pellets similar to those used for XRF analysis. This study proposes a method to determine twenty trace elements (fourteen rare earth elements, Sc, Y, Zr, Nb, Hf and Ta) by LA‐ICP‐MS directly from polished thick sections and rock slabs of six fine‐grained crystalline and aphanitic rocks (five volcanic rocks and one pelitic tillite). Laser scanning of eight to ten 20 mm long linear tracks using a spot size of 160 μm, with a total ablated area of 26–32 mm2, was performed. Quantification was carried out by (a) internal standardisation using Si and (b) without applying internal standardisation. In the latter method, external determination of one element in conventional LA‐ICP‐MS quantification is no longer needed. Although the fine‐grained rocks studied contained variable amounts of volatiles (up to 4%), this method gave results that agree within 10% relative with those obtained by internal standardisation using Si. Two USGS basalt glass reference materials (BCR‐2G and BHVO‐2G) were used for external calibration. The results and the associated trace element patterns and ratios of elemental pairs obtained from both methods of quantification showed good agreement with the results from solution nebulisation ICP‐MS within 20% (mostly within 10%) relative. Fine‐grained rocks are common and include volcanic, sedimentary and low‐grade metamorphic rocks (e.g., basalt, andesite, rhyolite, shale, mudstone, tillite, loess, pelite and slate) and their trace element contents and associated ratios are important geochemical tracers in studies focusing on the composition and evolution of the crust and mantle. Our method provides a simple and quantitative way to determine trace elements in fine‐grained rocks even with those displaying complex textures.


  • The rise of atomic spectrometry in China over the past 25 years

    by Shan Gao

    A graphical abstract is available for this content


  • Results for Rarely Determined Elements in MPI‐DING, USGS and NIST SRM Glasses Using Laser Ablation ICP‐MS

    by Zhaochu Hu, Yongsheng Liu, Ming Li, Shan Gao, Laishi Zhao

    New analytical results are reported for rarely determined elements Be, B, Ge, As, Mo, Rh, Pd, Ag, Cd, In, Sn, Sb, W, Re, Ir, Pt, Au, Tl and Bi in MPI‐DING and USGS (BCR‐2G, BHVO‐2G, BIR‐1G) silicate glasses and the NIST SRM 610‐614 synthetic soda‐lime glasses using 193 nm ArF excimer laser ablation and quadrupole ICP‐MS. The method used involved external calibration against GOR132‐G for Ir and NIST SRM 610 for other elements, internal standardisation using Ca, and ablation with a crater diameter of 160 μm and a pulsed laser repetition rate of 10 Hz. Small amounts of nitrogen (5 ml min−1) were added to the central channel gas of the plasma to improve the limits of detection for most of these elements by a factor of 1.2–2.5 and to reduce the oxide interference level to 0.02% (ThO+/Th+). Under these conditions, the LODs for most of these rarely determined elements were within the range 0.1 to 10 ng g−1. The operating conditions that were required to minimise ICP‐induced fractionation (U+/Th+≈ 1) in the mode without nitrogen were accompanied by a 50–60% reduction in sensitivity for elements such as Ca, Au and Pt. In contrast, ICP‐induced fractionation could be minimised (U+/Th+≈ 1) with no loss of analyte sensitivity in the nitrogen mode. Interferences of CuAr+, ZnAr+, Cd+, Pb2+ and Sn+ on Pd+, Rh+, Cd+ and In+ were corrected. Oxide interferences were not considered due to their lower production rate. Analytical precision, as given by one relative standard deviation (% RSD) was less than 15% for most of the elements present at concentrations greater than 0.1 μg g−1. A significant negative correlation was found between logarithmic concentration and logarithmic RSD, with a correlation coefficient of −0.76. This trend indicates that possible chemical heterogeneities for most of these elements are smaller than the analytical uncertainty. Our results for Be, B, Ge, Sb and W are generally in good agreement with their reference values. In contrast, other elements in many of the reference glasses have only information values, upper limits or even no values, which restrict any detailed evaluation of the accuracy of the determined values. However, concentrations from multiple isotopes of one element analysed in this study showed excellent agreement, which guarantee the quality of our data to a certain extent.


  • Delamination and destruction of the North China Craton

    by Shan Gao, JunFeng Zhang, WenLiang Xu, YongSheng Liu


  • Niobium and Tantalum Concentrations in NIST SRM 610 Revisited

    by Zhaochu Hu, Shan Gao, Yongsheng Liu, Juan Xu, Shenghong Hu, Haihong Chen

    Niobium and Ta concentrations in MPI‐DING and USGS (BCR‐2G, BHVO‐2G, BIR‐1G) silicate rock glasses and the NIST SRM 610–614 synthetic soda‐lime glasses were determined by 193 nm ArF excimer laser ablation and quadrupole ICP‐MS. Measured Nb and Ta values of MPI‐DING glasses were found to be consistently lower than the recommended values by about 15% and 25%, respectively, if calibration was undertaken using commonly accepted values of NIST SRM 610 given by Pearce et al. Analytical precision, as given by the 1 s relative standard deviation (% RSD) was less than 10% for Nb and Ta at concentrations higher than 0.1 μg g−1. A significant negative correlation was found between logarithmic concentration and logarithmic RSD, with correlation coefficients of ‐0.94 for Nb and ‐0.96 for Ta. This trend indicates that the analytical precision follows counting statistics and thus most of the measurement uncertainty was analytical in origin and not due to chemical heterogeneities. Large differences between measured and expected Nb and Ta in glasses GOR128‐G and GOR132‐G are likely to have been caused by the high RSDs associated with their very low concentrations. However, this cannot explain the large differences between measured and expected Nb and Ta in other MPI‐DING glasses, since the differences are normally higher than RSD by a factor of 3. Count rates for Nb and Ta, normalised to Ca sensitivity, for the MPI‐DING, USGS and NIST SRM 612–614 glasses were used to construct calibration curves for determining NIST SRM 610 concentrations at crater diameters ranging from 16 (im to 60 μm. The excellent correlation between the Nb/Ca1μgg‐1 signal (Nb represents the Nb signal intensity; Ca1μg g‐1 represents the Ca sensitivity) and Nb concentration, and between the Ta/Ca1μg g‐1 signal (where Ta represents the Ta signal intensity; Ca1μg g‐1 represents the Ca sensitivity) and Ta concentration (R2= 0.9992–1.00) in the various glass matrices suggests that matrix‐dependent fractionation for Nb, Ta and Ca was insignificant under the given instrumental conditions. The results confirm that calibration reference values of Nb and Ta in NIST SRM 610 given by Pearce et al. are about 16% and 28% lower, respectively. We thus propose a revision of the preferred value for Nb from 419.4 ± 57.6 μg g−1 to 485 ± 5 μg g−1 (1 s) and for Ta from 376.6 ± 77.6 μg g−1 to 482 ± 4 μg g−1 (Is) in NIST SRM 610. Using these revised values for external calibration, most of the determined average values of MPI‐DING, USGS and NIST SRM 612–614 reference glasses agree within 3% with the calculated means of reported reference values. Bulk analysis of NIST SRM 610 by standard additions using membrane desolvation ICP‐MS gave Nb = 479 ± 6 μg g−1 (1 s) and Ta = 468 ± 7 μg g−1 (1 s), which agree with the above revised values within 3%.


  • Top Cited Papers

    Signal enhancement in laser ablation ICP-MS by addition of nitrogen in the central channel gas

    by Zhaochu Hu, Shan Gao, Yongsheng Liu, Shenghong Hu, Haihong Chen, Honglin Yuan

    The effects of adding nitrogen to the central gas flow (Ar + He) of an Ar plasma in laser ablation inductively coupled plasma mass spectrometry are presented. The optimum central gas flow rate was found to be negatively correlated with the N2 gas flow rate. The addition of 5–10 ml min−1nitrogen to the central channel gas in LA-ICP-MS increases the sensitivity for most of the 65 investigated elements by a factor of 2–3. The degree of enhancement depends, to some extent, on the 1st ionization energy. Another important advantage of N2 mixed gas plasma for LA-ICP-MS is that the oxide ratios (ThO+/Th+) are significantly reduced (one order of magnitude). The hydride ratio (ArH+/Ar+) is also reduced up to a factor of 3, whereas the doubly charged ion ratio (Ca2+/Ca+) is increased. The background signals at masses 29, 31, 42, 51, 52 and 55 are significantly increased due to the nitrogen based polyatomic interferences. Compared to the spatial profiles of the ion distributions in the normal mode (without nitrogen), the addition of 5 ml min−1nitrogen leads to significant wider axial profiles and more uniform distribution of ions with different physical and chemical properties. Our results also show that the makeup gas flow (central channel gas) rate has a significant effect on the ion distribution of elements with different physical and chemical properties. A very consistent increase of argon signal by the addition of nitrogen (5 ml min−1) corroborates better energy transfer effect of nitrogen in the plasma.


  • Re–Os evidence for age and origin of peridotites from the Dabie–Sulu UHP belt

    by H.L. Yuan, S. Gao, R.L. Rudnick, Z.M. Jin, R.J. Walker