Praveen C. Ashok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Praveen C. Ashok has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Kishan Dholakia
Centre of Light for Life, School of Biological Sciences, Adelaide University, Adelaide, Australia
8 shared publications Bavishna B. Praveen
SUPA, School of Physics & Astronomy, North Haugh, University of St Andrews, St Andrews, Fife, Scotland KY16 9SS UK
3 shared publications- Thomas. F. Krauss
University of York
2 shared publications Andrew Riches
School of Medicine, Medical and Biological Sciences Building, University of St Andrews, North Haugh, St Andrews, Fife, Scotland, KY16 9TF UK
1 shared publication- Anna Chiara De Luca
Second unit, National Research Council (CNR, Via P Castellino 111, Naples, Italy, 80131
1 shared publication - Frank James Gunn-Moore
School of Biology, University of St Andrews, St Andrews, UK
1 shared publication
Latest Publications
- Open Access
- 16 September 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (10) , 2179-2186
Multi-modal approach using Raman spectroscopy and optical coherence tomography for the discrimination of colonic adenocarcinoma from normal colon
We report a multimodal optical approach using both Raman spectroscopy and optical coherence tomography (OCT) in tandem to discriminate between colonic adenocarcinoma and normal colon. Although both of these non-invasive techniques are capable of discriminating between normal and tumour tissues, they are unable individually to provide both the high specificity and high sensitivity required for disease diagnosis. We combine the chemical information derived from Raman spectroscopy with the texture parameters extracted from OCT images. The sensitivity obtained using Raman spectroscopy and OCT individually was 89% and 78% respectively and the specificity was 77% and 74% respectively. Combining the information derived using the two techniques increased both sensitivity and specificity to 94% demonstrating that combining complementary optical information enhances diagnostic accuracy. These data demonstrate that multimodal optical analysis has the potential to achieve accurate non-invasive cancer diagnosis.
- 16 September 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (10) , 2179-2186
Open AccessMulti-modal approach using Raman spectroscopy and optical coherence tomography for the discrimination of colonic adenocarcinoma from normal colon
We report a multimodal optical approach using both Raman spectroscopy and optical coherence tomography (OCT) in tandem to discriminate between colonic adenocarcinoma and normal colon. Although both of these non-invasive techniques are capable of discriminating between normal and tumour tissues, they are unable individually to provide both the high specificity and high sensitivity required for disease diagnosis. We combine the chemical information derived from Raman spectroscopy with the texture parameters extracted from OCT images. The sensitivity obtained using Raman spectroscopy and OCT individually was 89% and 78% respectively and the specificity was 77% and 74% respectively. Combining the information derived using the two techniques increased both sensitivity and specificity to 94% demonstrating that combining complementary optical information enhances diagnostic accuracy. These data demonstrate that multimodal optical analysis has the potential to achieve accurate non-invasive cancer diagnosis.
- 21 June 2013
- Published by Wiley in Journal of Biophotonics
- Vol. 7 (1-2) , 103-109
A Raman spectroscopy bio‐sensor for tissue discrimination in surgical robotics
We report the development of a fiber-based Raman sensor to be used in tumour margin identification during endoluminal robotic surgery. Although this is a generic platform, the sensor we describe was adapted for the ARAKNES (Array of Robots Augmenting the KiNematics of Endoluminal Surgery) robotic platform. On such a platform, the Raman sensor is intended to identify ambiguous tissue margins during robot-assisted surgeries. To maintain sterility of the probe during surgical intervention, a disposable sleeve was specially designed. A straightforward user-compatible interface was implemented where a supervised multivariate classification algorithm was used to classify different tissue types based on specific Raman fingerprints so that it could be used without prior knowledge of spectroscopic data analysis. The protocol avoids inter-patient variability in data and the sensor system is not restricted for use in the classification of a particular tissue type. Representative tissue classification assessments were performed using this system on excised tissue. (© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
- 21 June 2013
- Published by Wiley in Journal of Biophotonics
- Vol. 7 (1-2) , 103-109
A Raman spectroscopy bio‐sensor for tissue discrimination in surgical robotics
We report the development of a fiber-based Raman sensor to be used in tumour margin identification during endoluminal robotic surgery. Although this is a generic platform, the sensor we describe was adapted for the ARAKNES (Array of Robots Augmenting the KiNematics of Endoluminal Surgery) robotic platform. On such a platform, the Raman sensor is intended to identify ambiguous tissue margins during robot-assisted surgeries. To maintain sterility of the probe during surgical intervention, a disposable sleeve was specially designed. A straightforward user-compatible interface was implemented where a supervised multivariate classification algorithm was used to classify different tissue types based on specific Raman fingerprints so that it could be used without prior knowledge of spectroscopic data analysis. The protocol avoids inter-patient variability in data and the sensor system is not restricted for use in the classification of a particular tissue type. Representative tissue classification assessments were performed using this system on excised tissue. (© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
- 29 April 2013
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 44 (6) , 795-797
Optofluidic Raman sensor for simultaneous detection of the toxicity and quality of alcoholic beverages
We report a chemometric prediction of the toxicity and quality of liquor using an optofluidic sensor based upon Waveguide Confined Raman Spectroscopy (WCRS). The WCRS sensor was used to record the Raman spectra, each obtained from a 20 µl sample of a given alcoholic beverage with and acquisition time of 20 s. This was used to predict, simultaneously, both the methanol concentration (toxicity) and ethanol concentration (quality), with an accuracy of 0.1% and 0.7% by volume, respectively, using a Partial Least Squares‐based chemometric model. The model sensor is shown to be capable of identifying toxic liquors, based on the test performed on different types of liquor samples. Copyright © 2013 John Wiley & Sons, Ltd.
- 29 April 2013
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 44 (6) , 795-797
Optofluidic Raman sensor for simultaneous detection of the toxicity and quality of alcoholic beverages
We report a chemometric prediction of the toxicity and quality of liquor using an optofluidic sensor based upon Waveguide Confined Raman Spectroscopy (WCRS). The WCRS sensor was used to record the Raman spectra, each obtained from a 20 µl sample of a given alcoholic beverage with and acquisition time of 20 s. This was used to predict, simultaneously, both the methanol concentration (toxicity) and ethanol concentration (quality), with an accuracy of 0.1% and 0.7% by volume, respectively, using a Partial Least Squares‐based chemometric model. The model sensor is shown to be capable of identifying toxic liquors, based on the test performed on different types of liquor samples. Copyright © 2013 John Wiley & Sons, Ltd.
- 12 January 2012
- Published by Springer Nature
- p. 247-268
Microfluidic Raman Spectroscopy for Bio-chemical Sensing and Analysis
- 12 January 2012
- Published by Springer Nature
- p. 247-268
Microfluidic Raman Spectroscopy for Bio-chemical Sensing and Analysis
- 28 October 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (23) , 22982-22992
Near infrared spectroscopic analysis of single malt Scotch whisky on an optofluidic chip
Standardization and quality monitoring of alcoholic beverages is an important issue in the liquor production industry. Various spectroscopic techniques have proved useful for tackling this problem. An ideal sensing device for alcoholic beverages should be able to detect the quality of alcohol with a small amount of sample at a low acquisition time using a portable and easy to use device. We propose the use of near infra-red spectroscopy on an optofluidic chip for quality monitoring of single malt Scotch whisky. This is chip upon which we have previously realized waveguide confined Raman spectroscopy. Analysis on this alignment-free, portable chip may be performed in only 2 seconds with a sample volume of only 20 µl. Using a partial least square (PLS) calibration, we demonstrate that the alcohol content in the beverage may be predicted to within a 1% prediction error. Principal component analysis (PCA) was employed for successful classification of whiskies based upon their age, type and cask. The prospect of implementing an optofluidic analogue of a conventional fiber based spectroscopic probe allows a rapid analysis of alcoholic beverages with dramatically reduced sample volumes.
- 28 October 2011
- Published by Optica Publishing Group in Optics Express
- Vol. 19 (23) , 22982-22992
Near infrared spectroscopic analysis of single malt Scotch whisky on an optofluidic chip
Standardization and quality monitoring of alcoholic beverages is an important issue in the liquor production industry. Various spectroscopic techniques have proved useful for tackling this problem. An ideal sensing device for alcoholic beverages should be able to detect the quality of alcohol with a small amount of sample at a low acquisition time using a portable and easy to use device. We propose the use of near infra-red spectroscopy on an optofluidic chip for quality monitoring of single malt Scotch whisky. This is chip upon which we have previously realized waveguide confined Raman spectroscopy. Analysis on this alignment-free, portable chip may be performed in only 2 seconds with a sample volume of only 20 µl. Using a partial least square (PLS) calibration, we demonstrate that the alcohol content in the beverage may be predicted to within a 1% prediction error. Principal component analysis (PCA) was employed for successful classification of whiskies based upon their age, type and cask. The prospect of implementing an optofluidic analogue of a conventional fiber based spectroscopic probe allows a rapid analysis of alcoholic beverages with dramatically reduced sample volumes.
- 4 March 2011
- Published by IOP Publishing in Journal of Optics
- Vol. 13 (4)
Optical aberration compensation in a multiplexed optical trapping system
- 4 March 2011
- Published by IOP Publishing in Journal of Optics
- Vol. 13 (4)
Optical aberration compensation in a multiplexed optical trapping system
- 24 January 2011
- Published by Wiley in Journal of Biophotonics
- Vol. 4 (7-8) , 514-518
Enhanced bioanalyte detection in waveguide confined Raman spectroscopy using wavelength modulation
Waveguide confined Raman spectroscopy (WCRS) incorporates a fibre based Raman detection system in a microfluidic platform enabling the spectroscopic detection of analyte. It offers the possibility to develop portable, alignment free devices for bio-analyte sensing with minimal sample preparation. Ultimate sensitivity is limited by the fibre auto-fluorescence background. Here we report enhanced bio-analyte detection sensitivity by combining WCRS with continuous wavelength modulation technique. We used urea as a model analyte and the modulation parameters have been optimized to maximize the sensitivity of the device. (© 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
- 24 January 2011
- Published by Wiley in Journal of Biophotonics
- Vol. 4 (7-8) , 514-518
Enhanced bioanalyte detection in waveguide confined Raman spectroscopy using wavelength modulation
Waveguide confined Raman spectroscopy (WCRS) incorporates a fibre based Raman detection system in a microfluidic platform enabling the spectroscopic detection of analyte. It offers the possibility to develop portable, alignment free devices for bio-analyte sensing with minimal sample preparation. Ultimate sensitivity is limited by the fibre auto-fluorescence background. Here we report enhanced bio-analyte detection sensitivity by combining WCRS with continuous wavelength modulation technique. We used urea as a model analyte and the modulation parameters have been optimized to maximize the sensitivity of the device. (© 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
- 11 January 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1262-1270
Waveguide confined Raman spectroscopy for microfluidic interrogation
We report the first implementation of the fiber based microfluidic Raman spectroscopic detection scheme, which can be scaled down to micrometre dimensions, allowing it to be combined with other microfluidic functional devices. This novel Raman spectroscopic detection scheme, which we termed as Waveguide Confined Raman Spectroscopy (WCRS), is achieved through embedding fibers on-chip in a geometry that confines the Raman excitation and collection region which ensures maximum Raman signal collection. This results in a microfluidic chip with completely alignment-free Raman spectroscopic detection scheme, which does not give any background from the substrate of the chip. These features allow a WCRS based microfluidic chip to be fabricated in polydimethylsiloxane (PDMS) which is a relatively cheap material but has inherent Raman signatures in fingerprint region. The effects of length, collection angle, and fiber core size on the collection efficiency and fluorescence background of WCRS were investigated. The ability of the device to predict the concentration was studied using urea as a model analyte. A major advantage of WCRS is its scalability that allows it to be combined with many existing microfluidic functional devices. The applicability of WCRS is demonstrated through two microfluidic applications: reaction monitoring in a microreactor and detection of analyte in a microdroplet based microfluidic system. The WCRS approach may lead to wider use of Raman spectroscopy based detection in microfluidics, and the development of portable, alignment-free microfluidic devices.
- 11 January 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1262-1270
Waveguide confined Raman spectroscopy for microfluidic interrogation
We report the first implementation of the fiber based microfluidic Raman spectroscopic detection scheme, which can be scaled down to micrometre dimensions, allowing it to be combined with other microfluidic functional devices. This novel Raman spectroscopic detection scheme, which we termed as Waveguide Confined Raman Spectroscopy (WCRS), is achieved through embedding fibers on-chip in a geometry that confines the Raman excitation and collection region which ensures maximum Raman signal collection. This results in a microfluidic chip with completely alignment-free Raman spectroscopic detection scheme, which does not give any background from the substrate of the chip. These features allow a WCRS based microfluidic chip to be fabricated in polydimethylsiloxane (PDMS) which is a relatively cheap material but has inherent Raman signatures in fingerprint region. The effects of length, collection angle, and fiber core size on the collection efficiency and fluorescence background of WCRS were investigated. The ability of the device to predict the concentration was studied using urea as a model analyte. A major advantage of WCRS is its scalability that allows it to be combined with many existing microfluidic functional devices. The applicability of WCRS is demonstrated through two microfluidic applications: reaction monitoring in a microreactor and detection of analyte in a microdroplet based microfluidic system. The WCRS approach may lead to wider use of Raman spectroscopy based detection in microfluidics, and the development of portable, alignment-free microfluidic devices.
- 12 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (6) , 6396-6407
Optical chromatography using a photonic crystal fiber with on-chip fluorescence excitation
We describe the realization of integrated optical chromatography, in conjunction with on-chip fluorescence excitation, in a monolithically fabricated poly-dimethylsiloxane (PDMS) microfluidic chip. The unique endlessly-single-mode guiding property of the Photonic Crystal Fiber (PCF) facilitates simultaneous on-chip delivery of beams to perform optical sorting in conjunction with fluorescence excitation. We use soft lithography to define the chip and insert the specially capped PCF into it through a predefined fiber channel that is intrinsically aligned with the sorting channel. We compare the performance of the system to a standard ray optics model and use the system to demonstrate both size-driven and refractive index-driven separations of colloids. Finally we demonstrate a new technique of enhanced optofluidic separation of biological particles, by sorting of human kidney embryonic cells (HEK-293), internally tagged with fluorescing microspheres through phagocytocis, from those without microspheres and the separation purity is monitored using fluorescence imaging.
- 12 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (6) , 6396-6407
Optical chromatography using a photonic crystal fiber with on-chip fluorescence excitation
We describe the realization of integrated optical chromatography, in conjunction with on-chip fluorescence excitation, in a monolithically fabricated poly-dimethylsiloxane (PDMS) microfluidic chip. The unique endlessly-single-mode guiding property of the Photonic Crystal Fiber (PCF) facilitates simultaneous on-chip delivery of beams to perform optical sorting in conjunction with fluorescence excitation. We use soft lithography to define the chip and insert the specially capped PCF into it through a predefined fiber channel that is intrinsically aligned with the sorting channel. We compare the performance of the system to a standard ray optics model and use the system to demonstrate both size-driven and refractive index-driven separations of colloids. Finally we demonstrate a new technique of enhanced optofluidic separation of biological particles, by sorting of human kidney embryonic cells (HEK-293), internally tagged with fluorescing microspheres through phagocytocis, from those without microspheres and the separation purity is monitored using fluorescence imaging.