Pascal Pernet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pascal Pernet has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Michel Vaubourdolle
Service de Biochimie A, Hôpital St-Antoine, AP-HP, 75571 Paris Cedex 12, France
5 shared publicationsBénédicte Bénéteau-Burnat
Service de Biochimie A, Hôpital St-Antoine, AP-HP, 75571 Paris Cedex 12, France
3 shared publicationsAlain Jardel
1 shared publication- Bénédicte Bénéteau-Burnat
Service de Biochimie A, Hôpital Saint-Antoine, Paris, France
1 shared publication Christelle Hermand
1 shared publicationChristina Schneid
1 shared publication
Latest Publications
- 1 January 2009
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 27 (1) , 132.e1-132.e2
False elevation of blood lactate reveals ethylene glycol poisoning
- 1 January 2009
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 27 (1) , 132.e1-132.e2
False elevation of blood lactate reveals ethylene glycol poisoning
- 1 October 2008
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 26 (8) , 969.e1-969.e2
Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department
- 1 October 2008
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 26 (8) , 969.e1-969.e2
Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department
- 30 June 2006
- Published by Elsevier in Revue Francophone des Laboratoires
- Vol. 2006 (383) , 29-33
Les difficultés d'interprétation diagnostique de la co-Oxymétrie
- 30 June 2006
- Published by Elsevier in Revue Francophone des Laboratoires
- Vol. 2006 (383) , 29-33
Les difficultés d'interprétation diagnostique de la co-Oxymétrie
- 1 October 2004
- Published by Cambridge University Press (CUP) in British Journal of Nutrition
- Vol. 92 (4) , 627-634
Dose dependency of the effect of ornithine α-ketoglutarate on tissue glutamine concentrations and hypercatabolic response in endotoxaemic rats
The optimal dosage of ornithine α-ketoglutarate (OKG) for repleting tissue glutamine (Gln) concentrations and maintaining N homeostasis after injury is unknown. We set out to perform ‘dose-ranging’ of OKG supplementation after an endotoxaemic challenge. Sixty-one male Wistar rats were injected with 3 mg lipopolysaccharide (LPS) from Escherichia coli/kg (n 50) or saline vehicle (9 g NaCl/l; controls n 11). After a 24 h fast, survivors were fed by gavage for 48 h with a polymeric standard diet (879 kJ/kg per d and 1·18 g N/kg per d) supplemented with non-essential amino acids (control, n 11; LPS-OKG-0·0, n 9), or with 0·5 g OKG/kg per d (LPS-OKG-0·5, n 12), 1·5 OKG/kg per d (LPS-OKG-1.5, n 11) or 4·5 g OKG/kg per d (LPS-OKG-4·5, n 10). The diets for all groups were made isonitrogenous with the LPS-OKG-4·5 diet by adding an appropriate amount of non-essential amino acids. Rats were killed on day 3 for blood and tissue sampling (muscle, jejunum mucosa, liver). Urine was collected daily for 3-methylhistidine and total N assays. The OKG dose was correlated with Gln concentrations in every tissue and with cumulative N balance (Spearman test, PPt test, P<0·05). In conclusion, OKG exerted a dose-dependent effect on tissue Gln concentration and N balance, but only the highest dosage counteracted myofibrillar hypercatabolism and caused a positive N balance.
- 1 October 2004
- Published by Cambridge University Press (CUP) in British Journal of Nutrition
- Vol. 92 (4) , 627-634
Dose dependency of the effect of ornithine α-ketoglutarate on tissue glutamine concentrations and hypercatabolic response in endotoxaemic rats
The optimal dosage of ornithine α-ketoglutarate (OKG) for repleting tissue glutamine (Gln) concentrations and maintaining N homeostasis after injury is unknown. We set out to perform ‘dose-ranging’ of OKG supplementation after an endotoxaemic challenge. Sixty-one male Wistar rats were injected with 3 mg lipopolysaccharide (LPS) from Escherichia coli/kg (n 50) or saline vehicle (9 g NaCl/l; controls n 11). After a 24 h fast, survivors were fed by gavage for 48 h with a polymeric standard diet (879 kJ/kg per d and 1·18 g N/kg per d) supplemented with non-essential amino acids (control, n 11; LPS-OKG-0·0, n 9), or with 0·5 g OKG/kg per d (LPS-OKG-0·5, n 12), 1·5 OKG/kg per d (LPS-OKG-1.5, n 11) or 4·5 g OKG/kg per d (LPS-OKG-4·5, n 10). The diets for all groups were made isonitrogenous with the LPS-OKG-4·5 diet by adding an appropriate amount of non-essential amino acids. Rats were killed on day 3 for blood and tissue sampling (muscle, jejunum mucosa, liver). Urine was collected daily for 3-methylhistidine and total N assays. The OKG dose was correlated with Gln concentrations in every tissue and with cumulative N balance (Spearman test, PPt test, P<0·05). In conclusion, OKG exerted a dose-dependent effect on tissue Gln concentration and N balance, but only the highest dosage counteracted myofibrillar hypercatabolism and caused a positive N balance.
- 1 September 2004
- Published by Wolters Kluwer Health in American Journal of Medical Quality
- Vol. 19 (5) , 223-229
Development of an Internal Dynamic Web Site to Promote Quality Assurance in a Clinical Laboratory
In clinical laboratories, one challenging quality assurance objective is to maintain standardized practices. Meeting this objective entails ensuring information flow, which is necessary to smooth running of the laboratory. To facilitate information flow, we developed an internal quality Web site on our local network. The dynamic generated pages of the site were constructed with EasyPHP v.1.6, a complete freeware package providing PHP dynamic language and databases. The site comprises various sections: general news, specific laboratory units news, documents (quality manual, guidelines, emergency processes), schedules, National Quality Control results, forum, etc. Five to 10 pages are updated each week. This work was facilitated by the use of PHP-written pages and data tables, which enable us to record in real time the operation of our assurance quality project and to improve traceability. This approach could be extended to other aspects of quality management and could help meet the future IS015189 standard requirements.
- 1 September 2004
- Published by Wolters Kluwer Health in American Journal of Medical Quality
- Vol. 19 (5) , 223-229
Development of an Internal Dynamic Web Site to Promote Quality Assurance in a Clinical Laboratory
In clinical laboratories, one challenging quality assurance objective is to maintain standardized practices. Meeting this objective entails ensuring information flow, which is necessary to smooth running of the laboratory. To facilitate information flow, we developed an internal quality Web site on our local network. The dynamic generated pages of the site were constructed with EasyPHP v.1.6, a complete freeware package providing PHP dynamic language and databases. The site comprises various sections: general news, specific laboratory units news, documents (quality manual, guidelines, emergency processes), schedules, National Quality Control results, forum, etc. Five to 10 pages are updated each week. This work was facilitated by the use of PHP-written pages and data tables, which enable us to record in real time the operation of our assurance quality project and to improve traceability. This approach could be extended to other aspects of quality management and could help meet the future IS015189 standard requirements.
- 1 May 2004
- Published by Springer Nature in Bio Tribune Magazine
- Vol. 10 (1) , 54-56
Délocalisation de la biologie d’urgence et Assurance Qualité
- 1 May 2004
- Published by Springer Nature in Bio Tribune Magazine
- Vol. 10 (1) , 54-56
Délocalisation de la biologie d’urgence et Assurance Qualité
- Open Access
- 1 September 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (9) , 1440-1441
Evaluation of the AxSYM Homocysteine Assay and Comparison with the IMx Homocysteine Assay
Increased plasma total homocysteine (tHcy), a sulfur amino acid, is an important risk factor for vascular disease ( 1) and for arterial and venous thromboembolism ( 2). Several techniques have been developed to measure plasma or serum tHcy concentrations ( 3). Given the extension of this determination to routine clinical chemistry laboratories, an immunoassay has been developed for use with the AxSYM analyzer ( 4). The AxSYM is a completely automated system, which allows immediate and continuous access. We evaluated the analytical performance of the automated AxSYM assay and compared it with the IMx Hcy assay ( 5), a method widely used for tHcy determination in laboratories. Both methods use reduction of protein-bound Hcy by dithiothreitol, conversion of Hcy to S-adenosylhomocysteine in the presence of adenosine catalyzed by hydrolase enzyme and detection of S-adenosylhomocysteine by fluorescence polarization immunoassay. The AxSYM assay, however, gives the first result within 35 min (rather than 60 min) and allows random access. The AxSYM assay does not require sample pretreatment, and serum or plasma may be used. The assay requires 108 μL of sample, and up to 60 samples can be processed in 1 h (20 for the IMx).
- 1 September 2000
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 46 (9) , 1440-1441
Open AccessEvaluation of the AxSYM Homocysteine Assay and Comparison with the IMx Homocysteine Assay
Increased plasma total homocysteine (tHcy), a sulfur amino acid, is an important risk factor for vascular disease ( 1) and for arterial and venous thromboembolism ( 2). Several techniques have been developed to measure plasma or serum tHcy concentrations ( 3). Given the extension of this determination to routine clinical chemistry laboratories, an immunoassay has been developed for use with the AxSYM analyzer ( 4). The AxSYM is a completely automated system, which allows immediate and continuous access. We evaluated the analytical performance of the automated AxSYM assay and compared it with the IMx Hcy assay ( 5), a method widely used for tHcy determination in laboratories. Both methods use reduction of protein-bound Hcy by dithiothreitol, conversion of Hcy to S-adenosylhomocysteine in the presence of adenosine catalyzed by hydrolase enzyme and detection of S-adenosylhomocysteine by fluorescence polarization immunoassay. The AxSYM assay, however, gives the first result within 35 min (rather than 60 min) and allows random access. The AxSYM assay does not require sample pretreatment, and serum or plasma may be used. The assay requires 108 μL of sample, and up to 60 samples can be processed in 1 h (20 for the IMx).