Yali Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yali Sun has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Min Sun
Department of Earth Sciences, The University of Hong Kong, Pokfulam Road, Hong Kong, China
2 shared publicationsMei-Fu Zhou
Department of Earth Sciences, University of Hong Kong, Pokfulam Road, Hong Kong, China
1 shared publication
Latest Publications
- 1 December 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (7-8) , 1338-1340
Simultaneous determination of major, minor and trace elements in biocarbonates by inductively coupled plasma mass spectrometry
A method was developed for simultaneous determination of major (Ca), minor (Mg and Sr) and trace (Ba and U) elements in biocarbonates by inductively coupled plasma mass spectrometry (ICP–MS). The method precision (RSD%) is 0.73% for Ca, 0.77% for Mg, 0.59% for Sr, 2.02% for Ba, 1.13% for U, 0.67% for Mg/Ca, 0.27% for Sr/Ca, 2.06% for Ba/Ca and 1.23% for U/Ca. The ratio precision suggests that ICP–MS is satisfactory for obtaining multi-ratio data from biocarbonates. This technique was applied to 67 continuous coral samples.
- 1 December 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (7-8) , 1338-1340
Simultaneous determination of major, minor and trace elements in biocarbonates by inductively coupled plasma mass spectrometry
A method was developed for simultaneous determination of major (Ca), minor (Mg and Sr) and trace (Ba and U) elements in biocarbonates by inductively coupled plasma mass spectrometry (ICP–MS). The method precision (RSD%) is 0.73% for Ca, 0.77% for Mg, 0.59% for Sr, 2.02% for Ba, 1.13% for U, 0.67% for Mg/Ca, 0.27% for Sr/Ca, 2.06% for Ba/Ca and 1.23% for U/Ca. The ratio precision suggests that ICP–MS is satisfactory for obtaining multi-ratio data from biocarbonates. This technique was applied to 67 continuous coral samples.
- 16 March 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (4) , 345-349
Routine Os analysis by isotope dilution-inductively coupled plasma mass spectrometry: OsO4 in water solution gives high sensitivity
Os(IV) in 5% HCl + 5% ethanol solution and Os(VIII) in water solution are stable and the latter gives 30 times higher sensitivity than the former for ICP-MS analysis. The use of an offline OsO4 generator can effectively convert osmium to Os(VIII) and allows thorough cleaning after each sample preparation. The instrument memory for Os can be effectively cleaned by alternately flushing with 30% H2O2 and 5% HNO3 for 10 min. In order to overcome the analytical difficulties such as possible loss of the volatile OsO4 during sample preparation and long equilibrium time for Os analysis by ICP-MS, an isotope dilution (ID) method was adopted in this study. The ID-ICP-MS technique enables us to measure samples with Os content as low as 0.03 ng g−1, after Os is converted to OsO4 and trapped in water solution. This method has been applied to a series of eight Chinese national standard reference materials, ranging from soil, sediments, peridotite, to sulfide. The results are in good agreement with the certified values. The method precision is better than 6% RSD.
- 16 March 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (4) , 345-349
Routine Os analysis by isotope dilution-inductively coupled plasma mass spectrometry: OsO4 in water solution gives high sensitivity
Os(IV) in 5% HCl + 5% ethanol solution and Os(VIII) in water solution are stable and the latter gives 30 times higher sensitivity than the former for ICP-MS analysis. The use of an offline OsO4 generator can effectively convert osmium to Os(VIII) and allows thorough cleaning after each sample preparation. The instrument memory for Os can be effectively cleaned by alternately flushing with 30% H2O2 and 5% HNO3 for 10 min. In order to overcome the analytical difficulties such as possible loss of the volatile OsO4 during sample preparation and long equilibrium time for Os analysis by ICP-MS, an isotope dilution (ID) method was adopted in this study. The ID-ICP-MS technique enables us to measure samples with Os content as low as 0.03 ng g−1, after Os is converted to OsO4 and trapped in water solution. This method has been applied to a series of eight Chinese national standard reference materials, ranging from soil, sediments, peridotite, to sulfide. The results are in good agreement with the certified values. The method precision is better than 6% RSD.