Rémi Souchon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rémi Souchon has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Jean‐Yves Chapelon
Inserm, U1032, Lyon, France
2 shared publications- Olivier Rouvière
Hospices Civils de Lyon, Hôpital Edouard Herriot, Department of Imaging, Lyon, 69003, France; INSERM, LabTAU, U1032, Lyon, 69003 , France; Université Lyon 1, Lyon, 69003, France
2 shared publications Rares Salomir
Inserm, U1032, Lyon, France
2 shared publications- Adeline Bernard
Univ Lyon, INSA-Lyon, Universit Lyon 1, CNRS, Inserm, CREATIS UMR, Villeurbanne, France
1 shared publication Agnes Pousse
INSERM U556, 151 Cours Albert Thomas, 69424 Lyon Cedex 03, France
1 shared publicationAlexandre Petit
LabTAU, INSERM U1032, Lyon, France
1 shared publication
Latest Publications
- Open Access
- 29 January 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2)
Fast Volumetric Ultrasound B-Mode and Doppler Imaging with a New High-Channels Density Platform for Advanced 4D Cardiac Imaging/Therapy
A novel ultrasound (US) high-channels platform is a pre-requisite to open new frontiers in diagnostic and/or therapy by experimental implementation of innovative advanced US techniques. To date, a few systems with more than 1000 transducers permit full and simultaneous control in both transmission and receiving of all single elements of arrays. A powerful US platform for implementing 4-D (real-time 3-D) advanced US strategies, offering full research access, is presented in this paper. It includes a 1024-elements array prototype designed for 4-D cardiac dual-mode US imaging/therapy and 4 synchronized Vantage systems. The physical addressing of each element was properly chosen for allowing various array downsampled combinations while minimizing the number of driving systems. Numerical simulations of US imaging were performed, and corresponding experimental data were acquired to compare full and downsampled array strategies, testing 4-D imaging sequences and reconstruction processes. The results indicate the degree of degradation of image quality when using full array or downsampled combinations, and the contrast ratio and the contrast to noise ratio vary from 7.71 dB to 2.02 dB and from 2.99 dB to −7.31 dB, respectively. Moreover, the feasibility of the 4-D US platform implementation was tested on a blood vessel mimicking phantom for preliminary Doppler applications. The acquired data with fast volumetric imaging with up to 2000 fps allowed assessing the validity of common 3-D power Doppler, opening in this way a large field of applications.
- 29 January 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2)
Open AccessFast Volumetric Ultrasound B-Mode and Doppler Imaging with a New High-Channels Density Platform for Advanced 4D Cardiac Imaging/Therapy
A novel ultrasound (US) high-channels platform is a pre-requisite to open new frontiers in diagnostic and/or therapy by experimental implementation of innovative advanced US techniques. To date, a few systems with more than 1000 transducers permit full and simultaneous control in both transmission and receiving of all single elements of arrays. A powerful US platform for implementing 4-D (real-time 3-D) advanced US strategies, offering full research access, is presented in this paper. It includes a 1024-elements array prototype designed for 4-D cardiac dual-mode US imaging/therapy and 4 synchronized Vantage systems. The physical addressing of each element was properly chosen for allowing various array downsampled combinations while minimizing the number of driving systems. Numerical simulations of US imaging were performed, and corresponding experimental data were acquired to compare full and downsampled array strategies, testing 4-D imaging sequences and reconstruction processes. The results indicate the degree of degradation of image quality when using full array or downsampled combinations, and the contrast ratio and the contrast to noise ratio vary from 7.71 dB to 2.02 dB and from 2.99 dB to −7.31 dB, respectively. Moreover, the feasibility of the 4-D US platform implementation was tested on a blood vessel mimicking phantom for preliminary Doppler applications. The acquired data with fast volumetric imaging with up to 2000 fps allowed assessing the validity of common 3-D power Doppler, opening in this way a large field of applications.
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4182
Thermal lesion imaging using Lorentz force: Proofs of concept
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4182
Thermal lesion imaging using Lorentz force: Proofs of concept
- 29 August 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (6) , 1787-1793
Measurement of pulsatile motion with millisecond resolution by MRI
We investigated a technique based on phase‐contrast cine MRI combined with deconvolution of the phase shift waveforms to measure rapidly varying pulsatile motion waveforms. The technique does not require steady‐state displacement during motion encoding. Simulations and experiments were performed in porcine liver samples in view of a specific application, namely the observation of transient displacements induced by acoustic radiation force. Simulations illustrate the advantages and shortcomings of the methods. For experimental validation, the waveforms were acquired with an ultrafast ultrasound scanner (Supersonic Imagine Aixplorer), and the rates of decay of the waveforms (relaxation time) were compared. With bipolar motion‐encoding gradient of 8.4 ms, the method was able to measure displacement waveforms with a temporal resolution of 1 ms over a time course of 40 ms. Reasonable agreement was found between the rate of decay of the waveforms measured in ultrasound (2.8 ms) and in MRI (2.7–3.3 ms). Magn Reson Med, 2011.
- 29 August 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (6) , 1787-1793
Measurement of pulsatile motion with millisecond resolution by MRI
We investigated a technique based on phase‐contrast cine MRI combined with deconvolution of the phase shift waveforms to measure rapidly varying pulsatile motion waveforms. The technique does not require steady‐state displacement during motion encoding. Simulations and experiments were performed in porcine liver samples in view of a specific application, namely the observation of transient displacements induced by acoustic radiation force. Simulations illustrate the advantages and shortcomings of the methods. For experimental validation, the waveforms were acquired with an ultrafast ultrasound scanner (Supersonic Imagine Aixplorer), and the rates of decay of the waveforms (relaxation time) were compared. With bipolar motion‐encoding gradient of 8.4 ms, the method was able to measure displacement waveforms with a temporal resolution of 1 ms over a time course of 40 ms. Reasonable agreement was found between the rate of decay of the waveforms measured in ultrasound (2.8 ms) and in MRI (2.7–3.3 ms). Magn Reson Med, 2011.
- Open Access
- 24 September 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (4) , 871-881
Transient MR elastography (t‐MRE) using ultrasound radiation force: Theory, safety, and initial experiments in vitro
The purpose of our study was to assess the feasibility of using ultrasound radiation force as a safe vibration source for transient MR elastography (t‐MRE). We present a theoretical framework to predict the phase shift of the complex MRE signal, the temperature elevation due to ultrasound, and safety indicators (ISPPA,ISPTA,MI). Next, we report wave images acquired in porcine liver samples in vitro. MR thermometry was used to estimate the temperature elevation induced by ultrasound. Finally, we discuss the implications of our results with regard to the feasibility of using radiation force for t‐MRE in a clinical setting, and a specific echo‐planar imaging (EPI) MRE sequence is proposed. Magn Reson Med 60:871–881, 2008.
- 24 September 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (4) , 871-881
Open AccessTransient MR elastography (t‐MRE) using ultrasound radiation force: Theory, safety, and initial experiments in vitro
The purpose of our study was to assess the feasibility of using ultrasound radiation force as a safe vibration source for transient MR elastography (t‐MRE). We present a theoretical framework to predict the phase shift of the complex MRE signal, the temperature elevation due to ultrasound, and safety indicators (ISPPA,ISPTA,MI). Next, we report wave images acquired in porcine liver samples in vitro. MR thermometry was used to estimate the temperature elevation induced by ultrasound. Finally, we discuss the implications of our results with regard to the feasibility of using radiation force for t‐MRE in a clinical setting, and a specific echo‐planar imaging (EPI) MRE sequence is proposed. Magn Reson Med 60:871–881, 2008.
- 1 May 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5_Suppleme) , 2412
Improvement in elastographic signal-to-noise ratio and resolution using coded excitation in elastography
- 1 May 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5_Suppleme) , 2412
Improvement in elastographic signal-to-noise ratio and resolution using coded excitation in elastography