SSS. Jeff Shepard

S. Jeff Shepard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S. Jeff Shepard has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Charles E. Willis

    12 Imaging Physics Department, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Unit 1352, Houston, Texas 77030-4009

    2 shared publications
  • David L. Leong

    Analogic Corporation, 8 Centennial Drive, Peabody, Massachusetts 01960

    1 shared publication
  • Donald Peck

    Radiology, Henry Ford Hospital, 2799 W. Grand Blvd., Detroit, Michigan 48202

    1 shared publication
  • Ehsan Samei

    Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705

    1 shared publication
  • Eric Gingold

    Department of Radiology, Thomas Jefferson University Hospital, 132 South 10th Street, Philadelphia, Pennsylvania 19107

    1 shared publication
  • Eugene Mah

    Radiology Department, Medical University of South Carolina, PO Box 250322, 169 Ashley Ave., Charleston, South Carolina 29425

    1 shared publication

Latest Publications

  • Open Access

    An exposure indicator for digital radiography: AAPM Task Group 116 (Executive Summary)

    by S. Jeff Shepard, Jihong Wang, Michael Flynn, Eric Gingold, Lee Goldman, Kerry Krugh, David L. Leong, Eugene Mah, Kent Ogden, Donald Peck, et al.

    Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over‐ and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film‐based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines.


  • Implementing the DICOM Grayscale Standard Display Function for Mixed Hard- and Soft-Copy Operations

    by Stephen K. Thompson, Charles E. Willis, Kerry T. Krugh, S. Jeff Shepard, Kevin W. McEnery