Martijn C. Post
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martijn C. Post has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
R. J. Snijder
St Antonius Hospital, Department of Pulmonology, Nieuwegein, Netherlands
5 shared publicationsW. Budts
University Hospitals (UZ) Leuven, Department of Cardiology, Leuven, Belgium
4 shared publicationsC. J. J. Westermann
St Antonius Hospital, Department of Pulmonology, Nieuwegein, Netherlands
3 shared publicationsH. W. M. Plokker
Department of Cardiology, St Antonius Hospital, Nieuwegein, The Netherlands
3 shared publicationsH.W.M. Plokker
3 shared publicationsJ. J. Mager
St Antonius Hospital, Department of Pulmonology, Nieuwegein, Netherlands
3 shared publications
Latest Publications
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1)
The role of transthoracic contrast echocardiography in the clinical diagnosis of hereditary haemorrhagic telangiectasia
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1)
The role of transthoracic contrast echocardiography in the clinical diagnosis of hereditary haemorrhagic telangiectasia
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , 3591
Long-term mortality after percutaneous mitral valve repair using the edge-to-edge technique
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , 3591
Long-term mortality after percutaneous mitral valve repair using the edge-to-edge technique
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , 3763
Transapical paravalvular leakage closure in high surgical risk patients: procedural outcomes and mortality
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , 3763
Transapical paravalvular leakage closure in high surgical risk patients: procedural outcomes and mortality
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , P336
Diagnostic accuracy of the 100% oxygen method in detecting pulmonary right-to-left shunts compared to transthoracic contrast echocardiography
Background: Pulmonary right-to-left shunts are associated with severe neurological complications in patients with hereditary haemorrhagic telangiectasia (HHT). Screening has long been performed with the 100% oxygen method, but transthoracic contrast echocardiography (TTCE) is currently advised as first-line screenings technique. Purpose: The present study determined the diagnostic accuracy of the 100% oxygen method in detecting pulmonary shunts, using TTCE as gold standard. Methods: We included 189 persons, referred for HHT screening between 2004 and 2010, who underwent pulmonary shunt measurement with both the 100% oxygen method and TTCE. A pulmonary shunt of >5% measured with the 100% oxygen method was considered pathological. A quantitative three-point grading scale was used to classify the pulmonary shunt on TTCE (grade 0, no microbubbles; 1, 100 microbubbles). Results: A pulmonary shunt on TTCE was present in 95 out of 189 patients (50.3%). The 100% oxygen method demonstrated an abnormal shunt in only 49 (51.6%) of these patients (sensitivity 51.6%, specificity 87.2%, PPV 80.3, NPV 64.0%). Using the 100% oxygen method, a pathological pulmonary shunt was identified in 14.3%, 20% and 72.9% of patients with a pulmonary shunt grade 1, 2 and 3 on TTCE respectively. The 100% oxygen method indicated an abnormal pulmonary shunt in 12.8% of persons without any shunt on TTCE. In 13.3% of patients who underwent endovascular transcatheter embolotherapy of pulmonary shunts, the 100% oxygen method could not detect a pathological shunt. Conclusions: Large pulmonary shunts on TTCE may remain undetected using the 100% oxygen method. Our study confirms that the 100% oxygen method is not a useful screenings technique for the detection of pulmonary shunts.
- 1 August 2013
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (suppl 1) , P336
Diagnostic accuracy of the 100% oxygen method in detecting pulmonary right-to-left shunts compared to transthoracic contrast echocardiography
Background: Pulmonary right-to-left shunts are associated with severe neurological complications in patients with hereditary haemorrhagic telangiectasia (HHT). Screening has long been performed with the 100% oxygen method, but transthoracic contrast echocardiography (TTCE) is currently advised as first-line screenings technique. Purpose: The present study determined the diagnostic accuracy of the 100% oxygen method in detecting pulmonary shunts, using TTCE as gold standard. Methods: We included 189 persons, referred for HHT screening between 2004 and 2010, who underwent pulmonary shunt measurement with both the 100% oxygen method and TTCE. A pulmonary shunt of >5% measured with the 100% oxygen method was considered pathological. A quantitative three-point grading scale was used to classify the pulmonary shunt on TTCE (grade 0, no microbubbles; 1, 100 microbubbles). Results: A pulmonary shunt on TTCE was present in 95 out of 189 patients (50.3%). The 100% oxygen method demonstrated an abnormal shunt in only 49 (51.6%) of these patients (sensitivity 51.6%, specificity 87.2%, PPV 80.3, NPV 64.0%). Using the 100% oxygen method, a pathological pulmonary shunt was identified in 14.3%, 20% and 72.9% of patients with a pulmonary shunt grade 1, 2 and 3 on TTCE respectively. The 100% oxygen method indicated an abnormal pulmonary shunt in 12.8% of persons without any shunt on TTCE. In 13.3% of patients who underwent endovascular transcatheter embolotherapy of pulmonary shunts, the 100% oxygen method could not detect a pathological shunt. Conclusions: Large pulmonary shunts on TTCE may remain undetected using the 100% oxygen method. Our study confirms that the 100% oxygen method is not a useful screenings technique for the detection of pulmonary shunts.
- 2 November 2011
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 12 (12)
A complicated transseptal puncture during Mitraclip procedure: saved by 3D-TEE.
We report a case where real-time three-dimensional transoesophageal echocardiography (3D-TEE) was able to detect a complicated transseptal puncture during a Mitraclip procedure which was not seen on the two-dimensional TEE (2D-TEE) images. This case demonstrates the incremental value of 3D-TEE during transseptal puncture.
- 2 November 2011
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 12 (12)
A complicated transseptal puncture during Mitraclip procedure: saved by 3D-TEE.
We report a case where real-time three-dimensional transoesophageal echocardiography (3D-TEE) was able to detect a complicated transseptal puncture during a Mitraclip procedure which was not seen on the two-dimensional TEE (2D-TEE) images. This case demonstrates the incremental value of 3D-TEE during transseptal puncture.
- 1 August 2011
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 26 (3) , W81-W82
Cardiac Magnetic Resonance Imaging Showing Complete Resolution of Subendocardial Involvement in Churg-Strauss Syndrome
Churg-Strauss syndrome or allergic angiitis and granulomatosis is a rare systemic vasculitis. Cardiac involvement is the leading cause of mortality and includes eosinophilic endomyocarditis. We present a case of complete resolution of subendocardial involvement after high-dose corticosteroids, diagnosed by contrast-enhanced cardiovascular magnetic resonance imaging.
- 1 August 2011
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 26 (3) , W81-W82
Cardiac Magnetic Resonance Imaging Showing Complete Resolution of Subendocardial Involvement in Churg-Strauss Syndrome
Churg-Strauss syndrome or allergic angiitis and granulomatosis is a rare systemic vasculitis. Cardiac involvement is the leading cause of mortality and includes eosinophilic endomyocarditis. We present a case of complete resolution of subendocardial involvement after high-dose corticosteroids, diagnosed by contrast-enhanced cardiovascular magnetic resonance imaging.
- 23 December 2009
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 30 (1) , 64-68
Haemodynamic effects of patent foramen ovale and atrial septal defect closure: a comparison during percutaneous shunt closure
We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Twenty-five consecutive patients (mean age 49 +/- 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer. Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow methodology. Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7.1 +/- 5.4 (P = 0.003), 3.8 +/- 3.5 (P = 0.007) and 2.0 +/- 3.0 mmHg (P = ns) respectively. HR decreased 5.1 +/- 5.3 beats per minute (P = 0.01). SV, CO and TPR increased 8.5 +/- 6.4 ml (13.5%; P = 0.002), 0.21 +/- 0.45 l min(-1) (5.6%; P = ns) and 0.02 +/- 0.14 dynes (4.1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0.009). Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
- 23 December 2009
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 30 (1) , 64-68
Haemodynamic effects of patent foramen ovale and atrial septal defect closure: a comparison during percutaneous shunt closure
We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Twenty-five consecutive patients (mean age 49 +/- 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer. Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow methodology. Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7.1 +/- 5.4 (P = 0.003), 3.8 +/- 3.5 (P = 0.007) and 2.0 +/- 3.0 mmHg (P = ns) respectively. HR decreased 5.1 +/- 5.3 beats per minute (P = 0.01). SV, CO and TPR increased 8.5 +/- 6.4 ml (13.5%; P = 0.002), 0.21 +/- 0.45 l min(-1) (5.6%; P = ns) and 0.02 +/- 0.14 dynes (4.1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0.009). Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
- Open Access
- 25 November 2009
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 31 (2) , 142
Late device thrombosis after atrial septal defect closure
A 62-year-old woman with a history of transcatheter atrial septal defect (ASD) closure using a Cardioseal/Starflex® device was admitted for recurrent transient ischaemic attacks 3 years after closure. A transoesophageal echocardiogram (TEE) revealed a large, mobile, thrombus-like structure attached to the left-atrial side of the device as a potential cardio-embolic source. There was no evidence of device malposition or arm fractures. Four months after initiation of oral anticoagulants, a TEE showed no resolution of the thrombus-like structure. The patient refused the recommended surgical exploration. Unfortunately, she was re-admitted for recurrent stroke 2 months later. Finally, she approved with exploration through minimal invasive port access surgery. During surgery, a structure of 2 cm covering the device was removed. The device was explanted, followed by primary ASD closure. Microscopic examination confirmed the structure to be a fresh fibrin thrombus with granulocytes. The patient recovered well. Treatment with oral anticoagulants was continued for at least 6 months.
- 25 November 2009
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 31 (2) , 142
Open AccessLate device thrombosis after atrial septal defect closure
A 62-year-old woman with a history of transcatheter atrial septal defect (ASD) closure using a Cardioseal/Starflex® device was admitted for recurrent transient ischaemic attacks 3 years after closure. A transoesophageal echocardiogram (TEE) revealed a large, mobile, thrombus-like structure attached to the left-atrial side of the device as a potential cardio-embolic source. There was no evidence of device malposition or arm fractures. Four months after initiation of oral anticoagulants, a TEE showed no resolution of the thrombus-like structure. The patient refused the recommended surgical exploration. Unfortunately, she was re-admitted for recurrent stroke 2 months later. Finally, she approved with exploration through minimal invasive port access surgery. During surgery, a structure of 2 cm covering the device was removed. The device was explanted, followed by primary ASD closure. Microscopic examination confirmed the structure to be a fresh fibrin thrombus with granulocytes. The patient recovered well. Treatment with oral anticoagulants was continued for at least 6 months.
- Open Access
- 1 September 2009
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 17 (9) , 329-333
Long-term efficacy of bosentan in inoperable chronic thromboembolic pulmonary hypertension
- 1 September 2009
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 17 (9) , 329-333
Open AccessLong-term efficacy of bosentan in inoperable chronic thromboembolic pulmonary hypertension