Gaby S. Pell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gaby S. Pell has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Roger J. Ordidge
Melbourne Brain Centre Imaging Unit University of Melbourne Australia
4 shared publications - David L. Thomas
Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology University College London London UK
3 shared publications Craig A. Branch
Department of Medical Physics, Nathan S. Kline Institute for Psychiatric Research, Orangeburg, New York
2 shared publicationsDavid G. Gadian
The Royal College of Surgeons Unit of Biophysics, Institute of Child Health, University College London, London, United Kingdom
2 shared publicationsDavid P. Lewis
Department of Medical Physics, Nathan S. Kline Institute for Psychiatric Research, Orangeburg, New York
2 shared publications- Mark F. Lythgoe
UCL Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 29 December 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (1) , 46-54
TurboFLASH FAIR imaging with optimized inversion and imaging profiles
Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow‐sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion : imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low‐angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice‐selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice‐selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles. Magn Reson Med 51:46–54, 2004.
- 29 December 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (1) , 46-54
Open AccessTurboFLASH FAIR imaging with optimized inversion and imaging profiles
Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow‐sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion : imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low‐angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice‐selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice‐selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles. Magn Reson Med 51:46–54, 2004.
- Open Access
- 1 June 2003
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 23 (6) , 689-699
Comparative Study of the FAIR Technique of Perfusion Quantification with the Hydrogen Clearance Method
Arterial spin labeling magnetic resonance methods, including flow-sensitive alternating inversion recovery (FAIR), are becoming increasingly common for the noninvasive quantification of cerebral blood flow (CBF). This report compares the FAIR method with hydrogen clearance. The latter is an established, invasive technique for CBF measurement in animals. Paired readings of CBF were obtained in gerbils to maximize the degree of spatial and temporal correspondence between methods. Flow-sensitive alternating inversion recovery (50 averages, 6.7-minute measurement time) and hydrogen clearance measurements were made concurrently. Cerebral blood flow values measured by both techniques displayed an initial decrease because of the injurious effects of electrode insertion and subsequent recovery. Mixed model regression analysis, structural equations modeling, and a simple concordance correlation coefficient analysis were performed. No evidence of a marked systematic bias in the FAIR measurements was found; mixed model regression analysis yielded relative bias estimates of 0.4 (confidence interval: 3.0, 3.9) mL · 100 g−1 · min−1 and −3.7 (−12.1, 4.7) mL · 100 g−1 · min−1 at 20 and 100 mL · 100 g−1 · min−1, respectively. The principal limitation of the FAIR technique was the magnitude of the random measurement error (imprecision), which had a standard deviation on the order of 10 mL · 100 g−1 · min−1.
- 1 June 2003
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 23 (6) , 689-699
Open AccessComparative Study of the FAIR Technique of Perfusion Quantification with the Hydrogen Clearance Method
Arterial spin labeling magnetic resonance methods, including flow-sensitive alternating inversion recovery (FAIR), are becoming increasingly common for the noninvasive quantification of cerebral blood flow (CBF). This report compares the FAIR method with hydrogen clearance. The latter is an established, invasive technique for CBF measurement in animals. Paired readings of CBF were obtained in gerbils to maximize the degree of spatial and temporal correspondence between methods. Flow-sensitive alternating inversion recovery (50 averages, 6.7-minute measurement time) and hydrogen clearance measurements were made concurrently. Cerebral blood flow values measured by both techniques displayed an initial decrease because of the injurious effects of electrode insertion and subsequent recovery. Mixed model regression analysis, structural equations modeling, and a simple concordance correlation coefficient analysis were performed. No evidence of a marked systematic bias in the FAIR measurements was found; mixed model regression analysis yielded relative bias estimates of 0.4 (confidence interval: 3.0, 3.9) mL · 100 g−1 · min−1 and −3.7 (−12.1, 4.7) mL · 100 g−1 · min−1 at 20 and 100 mL · 100 g−1 · min−1, respectively. The principal limitation of the FAIR technique was the magnitude of the random measurement error (imprecision), which had a standard deviation on the order of 10 mL · 100 g−1 · min−1.
- Open Access
- 22 January 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (2) , 341-350
Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal
Accurate quantification of perfusion with the ADC techniques requires the suppression of the majority of the intravascular signal. This is normally achieved with the use of diffusion gradients. The TurboFLASH sequence with its ultrashort repetition times is not readily amenable to this scheme. This report demonstrates the implementation of a modified TurboFLASH sequence for FAIR imaging. Intravascular suppression is achieved with a modified preparation period that includes a driven equilibrium Fourier transform (DEFT) combination of 90°–180°–90° hard RF pulses subsequent to the inversion delay. These pulses rotate the perfusion-prepared magnetization into the transverse plane where it can experience the suitably placed diffusion gradients before being returned to the longitudinal direction by the second 90° pulse. A value of b = 20–30 s/mm2 was thereby found to suppress the majority of the intravascular signal. For single-slice perfusion imaging, quantification is only slightly modified. The technique can be readily extended to multislice acquisition if the evolving flow signal after the DEFT preparation is considered. An advantage of the modified preparation scheme is evident in the multislice FAIR images by the preservation of the sign of the magnetization difference. Magn Reson Med 49:341–350, 2003.
- 22 January 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (2) , 341-350
Open AccessPulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal
Accurate quantification of perfusion with the ADC techniques requires the suppression of the majority of the intravascular signal. This is normally achieved with the use of diffusion gradients. The TurboFLASH sequence with its ultrashort repetition times is not readily amenable to this scheme. This report demonstrates the implementation of a modified TurboFLASH sequence for FAIR imaging. Intravascular suppression is achieved with a modified preparation period that includes a driven equilibrium Fourier transform (DEFT) combination of 90°–180°–90° hard RF pulses subsequent to the inversion delay. These pulses rotate the perfusion-prepared magnetization into the transverse plane where it can experience the suitably placed diffusion gradients before being returned to the longitudinal direction by the second 90° pulse. A value of b = 20–30 s/mm2 was thereby found to suppress the majority of the intravascular signal. For single-slice perfusion imaging, quantification is only slightly modified. The technique can be readily extended to multislice acquisition if the evolving flow signal after the DEFT preparation is considered. An advantage of the modified preparation scheme is evident in the multislice FAIR images by the preservation of the sign of the magnetization difference. Magn Reson Med 49:341–350, 2003.
- Open Access
- 30 March 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 41 (3) , 479-485
Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T
- 30 March 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 41 (3) , 479-485
Open AccessEarly changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T
- Open Access
- 25 February 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 41 (2) , 368-374
Rapid T2* mapping using interleaved echo planar imaging
- 25 February 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 41 (2) , 368-374
Open AccessRapid T2* mapping using interleaved echo planar imaging