Hiroshi Ohtake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroshi Ohtake has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Go Watanabe
Department of General and Cardiothoracic Surgery, Kanazawa University School of Medicine, Kanazawa, Japan
12 shared publications - Shigeyuki Tomita
Kanazawa University
8 shared publications Go Watanabe
Department of General and Cardiothoracic Surgery, Kanazawa University Graduate School of Medical Science, Kanazawa, Japan
6 shared publications- Junichiro Sanada
Kanazawa University Graduate School of Medical Science
6 shared publications Keiichi Kimura
Department of General and Cardiothoracic Surgery, Kanazawa University, 13-1 Takara-machi, Kanazawa 920-8641, Japan
5 shared publications- Keiichi Kimura
Department of Thoracic, Cardiovascular and General Surgery, Kanazawa University
4 shared publications
Latest Publications
- Open Access
- 1 January 2018
- Published by Open Access Text Pvt, Ltd. in Trends in Medicine
- Vol. 18 (4)
A novel in vivo technique for endoscopic visualization of aortic valve motion and inner wall of large arteries for immediate postoperative direct observation
- 1 January 2018
- Published by Open Access Text Pvt, Ltd. in Trends in Medicine
- Vol. 18 (4)
Open AccessA novel in vivo technique for endoscopic visualization of aortic valve motion and inner wall of large arteries for immediate postoperative direct observation
- 1 October 2016
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 30 (5) , 1361-1363
Residual Mitral Regurgitation Elicited by Right Ventricular Pacing After Mitral Valve Repair
- 1 October 2016
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 30 (5) , 1361-1363
Residual Mitral Regurgitation Elicited by Right Ventricular Pacing After Mitral Valve Repair
- 1 June 2016
- Vol. 69 (6) , 443-6
[Emergency Thoracic Endovascular Aortic Repair of Ruptured Kommerell's Diverticulum with an Acute Aortic Dissection].
This case report describes emergency thoracic endovascular aortic repair (TEVAR) of a ruptured Kommerell's diverticulum associated with a type B acute aortic dissection in a patient with a right aortic arch. A 64-year-old male was admitted with symptoms of sudden paraplegia and shock. The computed tomography imaging showed right aortic arch anomaly, with mirror image branching of the major arteries. The aorta was dissected from the origin of the right subclavian artery to the terminal aorta, with a thrombosed false lumen. Rupture was found in a 6.3 cm aneurysm located in the distal arch, which was diagnosed as Kommerell's diverticulum. We performed emergency TEVAR, and the aneurysm was successfully excluded using deployment of a Gore Tag stent-graft. At 3 months' follow-up, the patient was doing well and showed shrinkage of the aneurysm was confirmed. TEVAR is considered to be a suitable procedure for an emergency aortic catastrophe even in patients with aortic anomaly.
- 1 June 2016
- Vol. 69 (6) , 443-6
[Emergency Thoracic Endovascular Aortic Repair of Ruptured Kommerell's Diverticulum with an Acute Aortic Dissection].
This case report describes emergency thoracic endovascular aortic repair (TEVAR) of a ruptured Kommerell's diverticulum associated with a type B acute aortic dissection in a patient with a right aortic arch. A 64-year-old male was admitted with symptoms of sudden paraplegia and shock. The computed tomography imaging showed right aortic arch anomaly, with mirror image branching of the major arteries. The aorta was dissected from the origin of the right subclavian artery to the terminal aorta, with a thrombosed false lumen. Rupture was found in a 6.3 cm aneurysm located in the distal arch, which was diagnosed as Kommerell's diverticulum. We performed emergency TEVAR, and the aneurysm was successfully excluded using deployment of a Gore Tag stent-graft. At 3 months' follow-up, the patient was doing well and showed shrinkage of the aneurysm was confirmed. TEVAR is considered to be a suitable procedure for an emergency aortic catastrophe even in patients with aortic anomaly.
- 1 February 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (2) , 677-680
A Novel One-Shot Circular Stapler Closure for Atrial Septal Defect in a Beating-Heart Porcine Model
- 1 February 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (2) , 677-680
A Novel One-Shot Circular Stapler Closure for Atrial Septal Defect in a Beating-Heart Porcine Model
- 1 April 2013
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 145 (4) , 1132-1133
One-shot aortic anastomosis with an automatic stapling gun
- 1 April 2013
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 145 (4) , 1132-1133
One-shot aortic anastomosis with an automatic stapling gun
- 23 January 2013
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 62 (03) , 261-264
Simultaneous Surgical Correction of Pectus Excavatum and Cardiac Disease in Two Adults
Thoracic reconstruction in patients with pectus excavatum with concomitant cardiac or aortic surgery poses a major clinical challenge. The report describes two cases of adult patients undergoing simultaneous surgical correction of cardiac disease and sternal deformity using one of two different techniques: a sterno-turnover method preserving the rectus muscle or a sternal elevation method with A-O plates.
- 23 January 2013
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 62 (03) , 261-264
Simultaneous Surgical Correction of Pectus Excavatum and Cardiac Disease in Two Adults
Thoracic reconstruction in patients with pectus excavatum with concomitant cardiac or aortic surgery poses a major clinical challenge. The report describes two cases of adult patients undergoing simultaneous surgical correction of cardiac disease and sternal deformity using one of two different techniques: a sterno-turnover method preserving the rectus muscle or a sternal elevation method with A-O plates.
- Open Access
- 1 September 2011
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 6 (5) , 344-346
Rapid Novel Aortic Arch Replacement for Thoracic Aortic Aneurysm Using Three Continuous Sutures and a Felt Cylindrical Collar
This report describes the novel parachute technique of open distal anastomosis at the aortic arch replacement. Two Teflon felt cylindrical collars were initially placed on the anastomotic site of the descending aorta. All four to five outer loops of the stitches used in the parachute technique were tracked by the gathering suture. The anastomotic sutures and three gathering sutures were finally pulled simultaneously. The prosthetic graft and the aortic stump with Teflon felt were safely and completely anastomosed. Surgical or hospital death and serious complications were not found. The mean anastomotic duration (circulatory arrest duration) in 16 patients was 23 minutes. Our novel technique using a Teflon felt cylindrical collar and modified continuous suturing was not only safe but also reduced the duration of anastomosis and minimized blood loss. This technique is simple and can be applied to aortic valve replacement.
- 1 September 2011
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 6 (5) , 344-346
Open AccessRapid Novel Aortic Arch Replacement for Thoracic Aortic Aneurysm Using Three Continuous Sutures and a Felt Cylindrical Collar
This report describes the novel parachute technique of open distal anastomosis at the aortic arch replacement. Two Teflon felt cylindrical collars were initially placed on the anastomotic site of the descending aorta. All four to five outer loops of the stitches used in the parachute technique were tracked by the gathering suture. The anastomotic sutures and three gathering sutures were finally pulled simultaneously. The prosthetic graft and the aortic stump with Teflon felt were safely and completely anastomosed. Surgical or hospital death and serious complications were not found. The mean anastomotic duration (circulatory arrest duration) in 16 patients was 23 minutes. Our novel technique using a Teflon felt cylindrical collar and modified continuous suturing was not only safe but also reduced the duration of anastomosis and minimized blood loss. This technique is simple and can be applied to aortic valve replacement.
- Open Access
- 1 June 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 12 (6) , 952-955
Tepid hypothermic (32 C) circulatory arrest for total aortic arch replacement: a paradigm shift from profound hypothermic surgery
In total aortic arch replacement (TARCH) using hypothermic circulatory arrest (HCA) and selective cerebral perfusion (SCP), postoperative cerebral co
- 1 June 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 12 (6) , 952-955
Open AccessTepid hypothermic (32 C) circulatory arrest for total aortic arch replacement: a paradigm shift from profound hypothermic surgery
In total aortic arch replacement (TARCH) using hypothermic circulatory arrest (HCA) and selective cerebral perfusion (SCP), postoperative cerebral co
- 1 February 2011
- Vol. 30 (1) , 88-91
Neurological deficit after simultaneous open abdominal aortic surgery and thoracic aortic endovascular therapy.
We examined a total of 12 cases; 8 cases were identified by searching the literature on Pubmed (excluding case reports published prior to 2000) and 4 cases were ones we personally encountered. We examined age, sex, history of smoking, and preoperative risk factors as preoperative factors, the access route and coverage of the descending aorta as perioperative factors, and complications and survival time as postoperative factors. Mean coverage of the thoracic aorta was 90.8 mm. In terms of perioperative deaths, 8.3% (1 patient) were due to coagulopathy. Perioperative complications occurred in 16.7% of cases (coagulopathy in 1 patient and paralysis in another). No patients experienced complications or underwent additional treatment during a mean follow-up of 22.9 months. This study suggested that simultaneous open abdominal aortic repair and thoracic aortic endovascular therapy is feasible and also involves few postoperative complications. Paraplegia and paralysis tended to occur less frequently than with two-stage surgery, but further study is needed to explain why this is true.
- 1 February 2011
- Vol. 30 (1) , 88-91
Neurological deficit after simultaneous open abdominal aortic surgery and thoracic aortic endovascular therapy.
We examined a total of 12 cases; 8 cases were identified by searching the literature on Pubmed (excluding case reports published prior to 2000) and 4 cases were ones we personally encountered. We examined age, sex, history of smoking, and preoperative risk factors as preoperative factors, the access route and coverage of the descending aorta as perioperative factors, and complications and survival time as postoperative factors. Mean coverage of the thoracic aorta was 90.8 mm. In terms of perioperative deaths, 8.3% (1 patient) were due to coagulopathy. Perioperative complications occurred in 16.7% of cases (coagulopathy in 1 patient and paralysis in another). No patients experienced complications or underwent additional treatment during a mean follow-up of 22.9 months. This study suggested that simultaneous open abdominal aortic repair and thoracic aortic endovascular therapy is feasible and also involves few postoperative complications. Paraplegia and paralysis tended to occur less frequently than with two-stage surgery, but further study is needed to explain why this is true.
- 1 December 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (6) , 1464-1470
Risk factor analysis of thoracic endovascular repair using the Matsui-Kitamura stent graft for acute aortic emergencies in the descending thoracic aorta
- 1 December 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (6) , 1464-1470
Risk factor analysis of thoracic endovascular repair using the Matsui-Kitamura stent graft for acute aortic emergencies in the descending thoracic aorta