Michael Oehme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Oehme has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Stephan Kölliker
3 shared publicationsZdenek Zencak
Department of Chemistry, University of Basel, St. Johanns-Ring 19, 4057 Basel, Switzerland
3 shared publicationsFabian Kuhn
Organic Analytical Chemistry, University of Basel, Neuhausstrasse 31, CH-4057 Basel, Switzerland
2 shared publicationsFernando Romero
Organic Analytical Chemistry, University of Basel, Basel, Switzerland
2 shared publicationsIngrid Langlois
Department of Chemistry, University of Basel, St. Johanns-Ring 19, 4057 Basel, Switzerland
2 shared publicationsSonja Skopp
Organic Analytical Chemistry, University of Basel, Neuhausstr. 31, CH‐4057 Basel, Switzerland; Fax: +41‐61‐6392300
2 shared publications
Latest Publications
- 25 October 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (22) , 3547-3553
Mass spectral studies of perfluorooctane sulfonate derivatives separated by high‐resolution gas chromatography
The mass spectral characteristics of perfluorooctane sulfonate (PFOS, C 8 F 17 SO ) isomers present in technical PFOS were obtained using high‐resolution gas chromatography (HRGC) combined with mass spectrometry (MS). To make PFOS amenable to HRGC separation, a simple derivatization procedure was developed. The method involved the conversion of PFOS into the iso ‐propyl ester using iso ‐propanol as the derivatization reagent under acidic conditions. Mass spectra were generated employing electron ionization (EI) and negative chemical ionization (NCI). Interpretation of fragment ions was possible due to the use of deuterium‐labeled iso ‐propanol as derivatization reagent, which induced mass shifts in the electron ionization (EI) and negative chemical ionization (NCI) mass spectra. HRMS allowed the accurate mass measurement of important EI fragments and confirmed the derivatization reaction as well as the proposed fragmentation pathway involving rearrangement. Moreover, the high resolution provided by HRGC enabled the separation of eleven PFOS isomers present in the technical product. This is an improvement over the previously reported high‐performance liquid chromatography (HPLC) separation. A complete identification of all isomers was not possible due to lack of pure reference materials. Finally, the developed derivatization procedure was successfully applied to perfluoroalkyl carboxylates (PFCA) and corresponding fragmentation involving rearrangement of the derivatized PFCA was observed. The described qualitative derivatization offers a promising alternative technique for the separation and identification of isomers of perfluoroalkyl sulfonates and carboxylates by HRGC/MS. Copyright © 2007 John Wiley & Sons, Ltd.
- 25 October 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (22) , 3547-3553
Mass spectral studies of perfluorooctane sulfonate derivatives separated by high‐resolution gas chromatography
The mass spectral characteristics of perfluorooctane sulfonate (PFOS, C 8 F 17 SO ) isomers present in technical PFOS were obtained using high‐resolution gas chromatography (HRGC) combined with mass spectrometry (MS). To make PFOS amenable to HRGC separation, a simple derivatization procedure was developed. The method involved the conversion of PFOS into the iso ‐propyl ester using iso ‐propanol as the derivatization reagent under acidic conditions. Mass spectra were generated employing electron ionization (EI) and negative chemical ionization (NCI). Interpretation of fragment ions was possible due to the use of deuterium‐labeled iso ‐propanol as derivatization reagent, which induced mass shifts in the electron ionization (EI) and negative chemical ionization (NCI) mass spectra. HRMS allowed the accurate mass measurement of important EI fragments and confirmed the derivatization reaction as well as the proposed fragmentation pathway involving rearrangement. Moreover, the high resolution provided by HRGC enabled the separation of eleven PFOS isomers present in the technical product. This is an improvement over the previously reported high‐performance liquid chromatography (HPLC) separation. A complete identification of all isomers was not possible due to lack of pure reference materials. Finally, the developed derivatization procedure was successfully applied to perfluoroalkyl carboxylates (PFCA) and corresponding fragmentation involving rearrangement of the derivatized PFCA was observed. The described qualitative derivatization offers a promising alternative technique for the separation and identification of isomers of perfluoroalkyl sulfonates and carboxylates by HRGC/MS. Copyright © 2007 John Wiley & Sons, Ltd.
- 8 February 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (5) , 844-850
Structural identification of isomers present in technical perfluorooctane sulfonate by tandem mass spectrometry
The structures of isomeric by‐products of technical perfluorooctane sulfonate (PFOS, C 8 F 17 SO ) were characterized by high‐performance liquid chromatography coupled to mass spectrometry. Ion trap (IT) as well as triple quadrupole (TQ) tandem mass spectrometry (MS/MS) identified ten PFOS isomers with best results being achieved by ion trap MS/MS. In addition to the linear isomer, the main by‐products were isomers with geminal diperfluoromethyl groups and perfluoromethyl‐substituted compounds. Purified fractions of the perfluoromethyl isomers allowed the elucidation of structures and the assignment of the retention times of perfluoroisopropyl‐, 5‐perfluoromethyl‐, 4‐perfluoromethyl‐, 3‐perfluoromethyl‐ and 1‐perfluoromethyl‐PFOS. The concentration of 2‐perfluoromethyl‐PFOS was too low in technical PFOS for a proper identification. Retention times of the geminal substituted diperfluoromethyl isomers could not be properly assigned due to co‐elutions. The number and position of the CF 3 groups can be derived from the MS/MS spectra, which allow an unequivocal identification of the isomers. TQ‐MS/MS also allowed us to identify most of the isomers. Copyright © 2006 John Wiley & Sons, Ltd.
- 8 February 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (5) , 844-850
Structural identification of isomers present in technical perfluorooctane sulfonate by tandem mass spectrometry
The structures of isomeric by‐products of technical perfluorooctane sulfonate (PFOS, C 8 F 17 SO ) were characterized by high‐performance liquid chromatography coupled to mass spectrometry. Ion trap (IT) as well as triple quadrupole (TQ) tandem mass spectrometry (MS/MS) identified ten PFOS isomers with best results being achieved by ion trap MS/MS. In addition to the linear isomer, the main by‐products were isomers with geminal diperfluoromethyl groups and perfluoromethyl‐substituted compounds. Purified fractions of the perfluoromethyl isomers allowed the elucidation of structures and the assignment of the retention times of perfluoroisopropyl‐, 5‐perfluoromethyl‐, 4‐perfluoromethyl‐, 3‐perfluoromethyl‐ and 1‐perfluoromethyl‐PFOS. The concentration of 2‐perfluoromethyl‐PFOS was too low in technical PFOS for a proper identification. Retention times of the geminal substituted diperfluoromethyl isomers could not be properly assigned due to co‐elutions. The number and position of the CF 3 groups can be derived from the MS/MS spectra, which allow an unequivocal identification of the isomers. TQ‐MS/MS also allowed us to identify most of the isomers. Copyright © 2006 John Wiley & Sons, Ltd.
- 1 November 2005
- Published by Springer Nature in Journal of Atmospheric Chemistry
- Vol. 52 (3) , 283-294
Organosulfates – A New Component of Humic-Like Substances in Atmospheric Aerosols?
- 1 November 2005
- Published by Springer Nature in Journal of Atmospheric Chemistry
- Vol. 52 (3) , 283-294
Organosulfates – A New Component of Humic-Like Substances in Atmospheric Aerosols?
- Open Access
- 1 September 2005
- Published by Swiss Chemical Society in Chimia
- Vol. 59 (9) , 708
High-Speed Identification of Designer Drugs by Multiple Mass Spectrometry
- 1 September 2005
- Published by Swiss Chemical Society in Chimia
- Vol. 59 (9) , 708
Open AccessHigh-Speed Identification of Designer Drugs by Multiple Mass Spectrometry
- 26 August 2005
- Published by Springer Nature in Archives of Environmental Contamination and Toxicology
- Vol. 49 (4) , 449-456
Presence of Chlorinated Paraffins in Sediments from the North and Baltic Seas
Chloroparaffins (CPs) were determined in sediments collected from the North and Baltic Seas during monitoring campaigns in 2001–2003. Electron ionization tandem mass spectrometry (MS/MS) was used for a first screening. It allowed the simultaneous determination of short (SCCP) and medium chain chlorinated paraffins (MCCP). SCCP+MCCP concentrations between 5 and 499 ng/g dry weight were found. In general, Baltic Sea sediments were more highly contaminated by CPs than the North Sea was. However, concentrations related to the total organic carbon content were on the same order of magnitude due to the higher organic content in the Baltic Sea. Additional information about the congener and homologue pattern was obtained for selected samples from the Baltic Sea by high-resolution gas chromatography combined with negative ion chemical ionization and low-resolution mass spectrometry, Concentrations in the North Sea were in general too low for this approach. In the Baltic Sea, MCCP concentrations were 1.7–2.4 times higher than for SCCPs. Lower chlorinated C13 and C14 compounds were the main CP compounds. The CP congener and homologue patterns showed similarities with technical SCCP and MCCP mixtures when compared using principal component analysis.
- 26 August 2005
- Published by Springer Nature in Archives of Environmental Contamination and Toxicology
- Vol. 49 (4) , 449-456
Presence of Chlorinated Paraffins in Sediments from the North and Baltic Seas
Chloroparaffins (CPs) were determined in sediments collected from the North and Baltic Seas during monitoring campaigns in 2001–2003. Electron ionization tandem mass spectrometry (MS/MS) was used for a first screening. It allowed the simultaneous determination of short (SCCP) and medium chain chlorinated paraffins (MCCP). SCCP+MCCP concentrations between 5 and 499 ng/g dry weight were found. In general, Baltic Sea sediments were more highly contaminated by CPs than the North Sea was. However, concentrations related to the total organic carbon content were on the same order of magnitude due to the higher organic content in the Baltic Sea. Additional information about the congener and homologue pattern was obtained for selected samples from the Baltic Sea by high-resolution gas chromatography combined with negative ion chemical ionization and low-resolution mass spectrometry, Concentrations in the North Sea were in general too low for this approach. In the Baltic Sea, MCCP concentrations were 1.7–2.4 times higher than for SCCPs. Lower chlorinated C13 and C14 compounds were the main CP compounds. The CP congener and homologue patterns showed similarities with technical SCCP and MCCP mixtures when compared using principal component analysis.
- 4 March 2005
- Published by Royal Society of Chemistry (RSC)
- Vol. 7 (4) , 319-324
Multivariate cluster analysis as a versatile tool for the quality assessment of short chain chloroparaffin quantification in environmental samples
The compositions of commercially available solutions of short chain chlorinated paraffins (SCCP) and technical mixtures were determined by high resolution gas chromatography (HRGC) electron capture negative ionisation (ECNI) combined with low resolution mass spectrometry (LRMS). Differences and similarities in the relative distribution of congeners and homologues were investigated by cluster analysis. Samples could be separated into two groups/clusters with similar molecular mass, chlorination degree and congener pattern. With the exception of one sample, the use of CH4-ECNI-MS led to an overestimation of the chlorine content. Moreover, the influence of different SCCP mixtures on the quantification was studied. The results showed that small differences in the chlorine content could sometimes cause substantial systematic errors of up to 119% despite similar homologue and congener patterns. Errors of quantification corresponded to the deviations between response factors of sample and standard. As a consequence SCCPs should be quantified with a standard matching the overall response factor of the sample.
- 4 March 2005
- Published by Royal Society of Chemistry (RSC)
- Vol. 7 (4) , 319-324
Multivariate cluster analysis as a versatile tool for the quality assessment of short chain chloroparaffin quantification in environmental samples
The compositions of commercially available solutions of short chain chlorinated paraffins (SCCP) and technical mixtures were determined by high resolution gas chromatography (HRGC) electron capture negative ionisation (ECNI) combined with low resolution mass spectrometry (LRMS). Differences and similarities in the relative distribution of congeners and homologues were investigated by cluster analysis. Samples could be separated into two groups/clusters with similar molecular mass, chlorination degree and congener pattern. With the exception of one sample, the use of CH4-ECNI-MS led to an overestimation of the chlorine content. Moreover, the influence of different SCCP mixtures on the quantification was studied. The results showed that small differences in the chlorine content could sometimes cause substantial systematic errors of up to 119% despite similar homologue and congener patterns. Errors of quantification corresponded to the deviations between response factors of sample and standard. As a consequence SCCPs should be quantified with a standard matching the overall response factor of the sample.
- 26 August 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (19) , 2235-2240
Chloride‐enhanced atmospheric pressure chemical ionization mass spectrometry of polychlorinated n ‐alkanes
The use of high‐performance liquid chromatography combined with chloride‐enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n ‐alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl] − adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1–2 ng/μL for technical PCA mixtures. Response factors for single short‐chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium‐chain PCAs were found in paint samples at concentrations of 8.2–11.5% (w/w), compared with 7.4–11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry. Copyright © 2004 John Wiley & Sons, Ltd.
- 26 August 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (19) , 2235-2240
Chloride‐enhanced atmospheric pressure chemical ionization mass spectrometry of polychlorinated n ‐alkanes
The use of high‐performance liquid chromatography combined with chloride‐enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n ‐alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl] − adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1–2 ng/μL for technical PCA mixtures. Response factors for single short‐chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium‐chain PCAs were found in paint samples at concentrations of 8.2–11.5% (w/w), compared with 7.4–11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry. Copyright © 2004 John Wiley & Sons, Ltd.
- 1 April 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (7) , 1741-1747
Limitations of low resolution mass spectrometry in the electron capture negative ionization mode for the analysis of short- and medium-chain chlorinated paraffins
The analysis of complex mixtures of chlorinated paraffins (CPs) with short (SCCPs, C10–C13) and medium (MCCPs, C14–C17) chain lengths can be disturbed by mass overlap, if low resolution mass spectrometry (LRMS) in the electron capture negative ionization mode is employed. This is caused by CP congeners with the same nominal mass, but with five carbon atoms more and two chlorine atoms less; for example C11H17 37Cl35Cl6 (m/z 395.9) and C16H29 35Cl5 (m/z 396.1). This can lead to an overestimation of congener group quantity and/or of total CP concentration. The magnitude of this interference was studied by evaluating the change after mixing a SCCP standard and a MCCP standard 1+1 (S+MCCP mixture) and comparing it to the single standards. A quantification of the less abundant C16 and C17 congeners present in the MCCP standard was not possible due to interference from the major C11 and C12 congeners in the SCCPs. Also, signals for SCCPs (C10–C12) with nine and ten chlorine atoms were mimicked by MCCPs (C15–C17) with seven and eight chlorine atoms (for instance C10H12Cl10 by C15H24Cl8). A similar observation was made for signals from C15–C17 CPs with four and five chlorine atoms resulting from SCCPs (C10–C12) with six and seven chlorine atoms (such as C15H28Cl4 by C10H16Cl6) in the S+MCCP mixture. It could be shown that the quantification of the most abundant congeners (C11–C14) is not affected by any interference. The determination of C10 and C15 congeners is partly disturbed, but this can be detected by investigating isotope ratios, retention time ranges and the shapes of the CP signals. Also, lower chlorinated compounds forming [M+Cl]− as the most abundant ion instead of [M-Cl]− are especially sensitive to systematic errors caused by superposition of ions of different composition and the same nominal mass.
- 1 April 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (7) , 1741-1747
Limitations of low resolution mass spectrometry in the electron capture negative ionization mode for the analysis of short- and medium-chain chlorinated paraffins
The analysis of complex mixtures of chlorinated paraffins (CPs) with short (SCCPs, C10–C13) and medium (MCCPs, C14–C17) chain lengths can be disturbed by mass overlap, if low resolution mass spectrometry (LRMS) in the electron capture negative ionization mode is employed. This is caused by CP congeners with the same nominal mass, but with five carbon atoms more and two chlorine atoms less; for example C11H17 37Cl35Cl6 (m/z 395.9) and C16H29 35Cl5 (m/z 396.1). This can lead to an overestimation of congener group quantity and/or of total CP concentration. The magnitude of this interference was studied by evaluating the change after mixing a SCCP standard and a MCCP standard 1+1 (S+MCCP mixture) and comparing it to the single standards. A quantification of the less abundant C16 and C17 congeners present in the MCCP standard was not possible due to interference from the major C11 and C12 congeners in the SCCPs. Also, signals for SCCPs (C10–C12) with nine and ten chlorine atoms were mimicked by MCCPs (C15–C17) with seven and eight chlorine atoms (for instance C10H12Cl10 by C15H24Cl8). A similar observation was made for signals from C15–C17 CPs with four and five chlorine atoms resulting from SCCPs (C10–C12) with six and seven chlorine atoms (such as C15H28Cl4 by C10H16Cl6) in the S+MCCP mixture. It could be shown that the quantification of the most abundant congeners (C11–C14) is not affected by any interference. The determination of C10 and C15 congeners is partly disturbed, but this can be detected by investigating isotope ratios, retention time ranges and the shapes of the CP signals. Also, lower chlorinated compounds forming [M+Cl]− as the most abundant ion instead of [M-Cl]− are especially sensitive to systematic errors caused by superposition of ions of different composition and the same nominal mass.
- 21 January 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (5) , 1294-1304
Structure elucidation of nanogram quantities of unknown designer drugs based on phenylalkylamine derivates by ion trap multiple mass spectrometry
- 21 January 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (5) , 1294-1304
Structure elucidation of nanogram quantities of unknown designer drugs based on phenylalkylamine derivates by ion trap multiple mass spectrometry
- 22 September 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 1018 (2) , 203-212
Performance and reliability of splitless microliter gradient pumps in a metabolic stability study using cytochrome P450/3A4 and capillary liquid chromatography-mass spectrometry.
- 22 September 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 1018 (2) , 203-212
Performance and reliability of splitless microliter gradient pumps in a metabolic stability study using cytochrome P450/3A4 and capillary liquid chromatography-mass spectrometry.