RERonald F. Elsner

Ronald F. Elsner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ronald F. Elsner has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mathematical formalism for designing wide-field x-ray telescopes: mirror nodal positions and detector tilts

    by Ronald F. Elsner, Stephen L. O'Dell, Brian D. Ramsey, Martin C. Weisskopf

    We describe a mathematical formalism for determining the mirror shell nodal positions and detector tilts that optimize the spatial resolution averaged over a field-of-view for a nested x-ray telescope, assuming known mirror segment surface prescriptions and known detector focal surface. The results are expressed in terms of ensemble averages over variable combinations of the ray positions and wavevectors in the flat focal plane intersecting the optical axis at the nominal on-axis focus, which can be determined by Monte-Carlo ray traces of the individual mirror shells. This work is part of our continuing efforts to provide analytical tools to aid in the design process for wide-field survey x-ray astronomy missions.

  • Open Access

    Methods of optimizing X-ray optical prescriptions for wide-field applications

    by Ronald F. Elsner, Stephen L. O'Dell, Brian D. Ramsey, Martin C. Weisskopf

    We are working on the development of a method for optimizing wide-field X-ray telescope mirror prescriptions, including polynomial coefficients, mirror shell relative displacements, and (assuming 4 focal plane detectors) detector placement along the optical axis and detector tilt. With our methods, we hope to reduce number of Monte-Carlo ray traces required to search the multi-dimensional design parameter space, and to lessen the complexity of finding the optimum design parameters in that space. Regarding higher order polynomial terms as small perturbations of an underlying Wolter I optic design, we begin by using the results of Monte-Carlo ray traces to devise trial analytic functions, for an individual Wolter I mirror shell, that can be used to represent the spatial resolution on an arbitrary focal surface. We then introduce a notation and tools for Monte-Carlo ray tracing of a polynomial mirror shell prescription which permits the polynomial coefficients to remain symbolic. In principle, given a set of parameters defining the underlying Wolter I optics, a single set of Monte-Carlo ray traces are then sufficient to determine the polymonial coefficients through the solution of a large set of linear equations in the symbolic coefficients. We describe the present status of this development effort.

  • On the design of wide-field x-ray telescopes

    by Ronald F. Elsner, Stephen L. O'Dell, Brian D. Ramsey, Martin C. Weisskopf

    X-ray telescopes having a relatively wide field-of-view and spatial resolution vs. polar off-axis angle curves much flatter than the parabolic dependence characteristic of Wolter I designs are of great interest for surveys of the X-ray sky and potentially for study of the Sun's X-ray emission. We discuss the various considerations affecting the design of such telescopes, including the possible use of polynomial mirror surface prescriptions, a method of optimizing the polynomial coefficients, scaling laws for mirror segment length vs. intersection radius, the loss of on-axis spatial resolution, and the positioning of focal plane detectors.

  • Chandra X‐Ray ObservatoryObservations of the Globular Cluster M71

    by Ronald F. Elsner, Craig O. Heinke, Haldan N. Cohn, Phyllis M. Lugger, J. Edward Maxwell, Ingrid H. Stairs, Scott M. Ransom, Jason W. T. Hessels, Werner Becker, Regina H. H. Huang, et al.


  • Open Access

    Chandra X-Ray Observatory Observations of the Globular Cluster M71

    by R. F. Elsner, C. O. Heinke, H. N. Cohn, P. M. Lugger, J. E. Maxwell, I. H. Stairs, S. M. Ransom, J. W. T. Hessels, W. Becker, R. H. H. Huang, et al.

    We observed the nearby, low-density globular cluster M71 (NGC 6838) with the Chandra X-ray Observatory to study its faint X-ray populations. Five X-ray sources were found inside the cluster core radius, including the known eclipsing binary millisecond pulsar (MSP) PSR J1953+1846A. The X-ray light curve of the source coincident with this MSP shows marginal evidence for periodicity at the binary period of 4.2 h. Its hard X-ray spectrum and luminosity resemble those of other eclipsing binary MSPs in 47 Tuc, suggesting a similar shock origin of the X-ray emission. A further 24 X-ray sources were found within the half-mass radius, reaching to a limiting luminosity of 1.5 10^30 erg/s (0.3-8 keV). From a radial distribution analysis, we find that 18+/-6 of these 29 sources are associated with M71, somewhat more than predicted, and that 11+/-6 are background sources, both galactic and extragalactic. M71 appears to have more X-ray sources between L_X=10^30--10^31 erg/s than expected by extrapolating from other studied clusters using either mass or collision frequency. We explore the spectra and variability of these sources, and describe the results of ground-based optical counterpart searches.

  • Thermal and Non-Thermal Components of the X-Ray Emission from Jupiter

    by Grazillea Branduardi-Raymont, Anil Bhardwaj, Ronald F. Elsner, G. Randall Gladstone, Gavin Ramsay, Pedro Rodriguez, Roberto Soria, J. Hunter Waite, Thomas E. Cravens


  • Low‐ to middle‐latitude X‐ray emission from Jupiter

    by Anil Bhardwaj, Ronald F. Elsner, G. Randall Gladstone, J. Hunter Waite, Graziella Branduardi‐Raymont, Thomas E. Cravens, Peter G. Ford

    The Chandra X‐ray Observatory (CXO) observed Jupiter during the period 24–26 February 2003 for ∼40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS‐S) and the imaging array of the High‐Resolution Camera (HRC‐I). Two ACIS‐S exposures, each ∼8.5 hours long, were separated by an HRC‐I exposure of ∼20 hours. The low‐ to middle‐latitude nonauroral disk X‐ray emission is much more spatially uniform than the auroral emission. However, the low‐ to middle‐latitude X‐ray count rate shows a small but statistically significant hour angle dependence and depends on surface magnetic field strength. In addition, the X‐ray spectra from regions corresponding to 3–5 gauss and 5–7 gauss surface fields show significant differences in the energy band 1.26–1.38 keV, perhaps partly due to line emission occurring in the 3–5 gauss region but not the 5–7 gauss region. A similar correlation of surface magnetic field strength with count rate is found for the 18 December 2000 HRC‐I data, at a time when solar activity was high. The low‐ to middle‐latitude disk X‐ray count rate observed by the HRC‐I in the February 2003 observation is about 50% of that observed in December 2000, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low‐ to middle‐latitude X‐ray emission does not show any oscillations similar to the ∼45 min oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's nonauroral X‐ray emission exhibits similarities to variations in solar X‐ray flux observed by GOES and TIMED/SEE. The two ACIS‐S 0.3–2.0 keV low‐ to middle‐latitude X‐ray spectra are harder than the auroral spectrum and are different from each other at energies above 0.7 keV, showing variability in Jupiter's nonauroral X‐ray emission on a timescale of a day. The 0.3–2.0 keV X‐ray power emitted at low to middle latitudes is 0.21 GW and 0.39 GW for the first and second ACIS‐S exposures, respectively. We suggest that X‐ray emission from Jupiter's disk may be largely generated by the scattering and fluorescence of solar X rays in its upper atmosphere, especially at times of high incident solar X‐ray flux. However, the dependence of count rate on surface magnetic‐field strength may indicate the presence of some secondary component, possibly ion precipitation from radiation belts close to the planet.


  • Simultaneous Chandra X ray, Hubble Space Telescope ultraviolet, and Ulysses radio observations of Jupiter's aurora

    by R. F. Elsner, N. Lugaz, J. H. Waite, T. E. Cravens, G. R. Gladstone, P. Ford, D. Grodent, A. Bhardwaj, R. J. MacDowall, M. D. Desch, et al.

    Observations of Jupiter carried out by the Chandra Advanced CCD Imaging Spectrometer (ACIS‐S) instrument over 24–26 February 2003 show that the auroral X‐ray spectrum consists of line emission consistent with high‐charge states of precipitating ions, and not a continuum as might be expected from bremsstrahlung. The part of the spectrum due to oxygen peaks around 650 eV, which indicates a high fraction of fully stripped oxygen in the precipitating ion flux. A combination of the OVIII emission lines at 653 eV and 774 eV, as well as the OVII emission lines at 561 eV and 666 eV, are evident in the measure auroral spectrum. There is also line emission at lower energies in the spectral region extending from 250 to 350 eV, which could be from sulfur and/or carbon. The Jovian auroral X‐ray spectra are significantly different from the X‐ray spectra of comets. The charge state distribution of the oxygen ions implied by the measured auroral X‐ray spectra strongly suggests that independent of the source of the energetic ions, magnetospheric or solar wind, the ions have undergone additional acceleration. This spectral evidence for ion acceleration is also consistent with the relatively high intensities of the X rays compared with the available phase space density of the (unaccelerated) source populations of solar wind or magnetospheric ions at Jupiter, which are orders of magnitude too small to explain the observed emissions. The Chandra X‐ray observations were executed simultaneously with observations at ultraviolet wavelengths by the Hubble Space Telescope and at radio wavelengths by the Ulysses spacecraft. These additional data sets suggest that the source of the X rays is magnetospheric in origin and that the precipitating particles are accelerated by strong field‐aligned electric fields, which simultaneously create both the several‐MeV energetic ion population and the relativistic electrons observed in situ by Ulysses that are correlated with ∼40 min quasi‐periodic radio outbursts.


  • Effective area of the AXAF high-resolution camera (HRC)

    by Daniel Patnaude, Deron O. Pease, R. Hank Donnelly, Michael Juda, Christine Jones, Stephen S. Murray, Martin V. Zombeck, Ralph Porter Kraft, Almus T. Kenter, Gary R. Meehan, et al.

    The Advanced X-Ray Astrophysics Facility High Resolution Camera was calibrated at NASA's X-Ray Calibration Facility during March and April 1997. We have undertaken an analysis of the effective area of the combined High Resolution Mirror Assembly/High Resolution Camera using all data presently available from these tests. In this contribution we discuss our spectral fitting of the beam-normalization detectors, our method of removing higher order contamination lines present in the spectra, and the corrections for beam non- uniformities. Using an approach based upon the mass absorption cross-section of Cesium Iodide, we determine the quantum efficiency in the microchannel plates. We model the secondary electron absorption depth as a function of energy, which we expect to be relatively smooth. This is then combined with the most recent model of the telescope to determine the ensemble effective area for the HRC. The ensemble effective area is a product of the telescope effective are, the transmission of the UV-Ion shield, and the quantum efficiency of the microchannel plates. We focus our attention on the microchannel plate quantum efficiency, using previous result for the UV-Ion shield transmission and telescope effective area. We also address future goals and concerns.

  • Calibration results for the AXAF flight contamination monitor

    by Ronald F. Elsner, Stephen L. O'Dell, Brian D. Ramsey, Allyn F. Tennant, Martin C. Weisskopf, Jeffery J. Kolodziejczak, Douglas A. Swartz, Darell E. Engelhaupt, Gordon P. Garmire, John A. Nousek, et al.

    The Advanced X-ray Astrophysics Facility (AXAF) ground calibration program, easily the most extensive in the history of high energy astrophysics, requires careful attention to the verification of its validity for on-orbit operations of the observatory. The purpose of the Flight Contamination Monitor (FCM) is to verify the transfer of the AXAF absolute flux scale calibration from ground to on-orbit operations and to measure or bound any changes in molecular contamination on the AXAF mirrors. This paper reports the current status of the analysis of FCM measurements taken during ground calibration. The FCM measurements during the AXAF activation phase will be the first look at the on-orbit AXAF performance.