Mohamed H. Hamdan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed H. Hamdan has a total of 207 co-authors. Here are the top co-authors by number of shared publications:
Stephen L. Wasmund
Division of Cardiology, University of Utah, Medical Center, Salt Lake City, Utah
9 shared publicationsMarcos Daccarett
Division of Cardiology, University of Utah, Medical Center, Salt Lake City, Utah
6 shared publications- Michele Brignole
Department of Cardiology, IRCCS Istituto Auxologico Italiano, Faint and Fall Research Centre, S. Luca Hospital , Piazzale Brescia 20, Milano 20149
5 shared publications Nazem W. Akoum
Department of Internal Medicine, University of Utah Health Sciences Center and Nora Eccles Harrison Cardiovascular Research and Training Institute, Salt Lake City, Utah
5 shared publicationsNathan M. Segerson
University of Utah, Salt Lake City, UT, USA
4 shared publicationsTawni L. Jetter
4 shared publications
Latest Publications
- 30 July 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (10) , 1232-1235
Atrial Bigeminy Results in Decreased Left Ventricular Function: An Insight into the Mechanism of PVC‐Induced Cardiomyopathy
Background: Premature ventricular complexes have been recently recognized as a reversible cause of cardiomyopathy. The purpose of this study was to determine if premature complexes independent of “dyssynchrony” resulted in increased left ventricular (LV) dimensions and decreased LV function. Methods: Ten mongrel dogs underwent the implantation of a pacemaker and were randomized to a control group (n = 5) or a paced group (n = 5). In the paced group, the pacemaker was connected to two endocardial atrial leads, one inserted into the atrial port and the other one into the ventricular port with an atrioventricular delay adjusted to ensure the presence of coupled pacing simulating atrial bigeminy with conducted beats in the absence of aberrancy. Echocardiographic parameters of LV size (LV end‐diastolic diameter [LV‐EDD], LV end‐systolic diameter [LV‐ESD]), and LV ejection fraction (LVEF) were measured at baseline and after 4 weeks of monitoring (control group) or pacing (paced group). Results: In the control group, LV size decreased with no significant changes in LVEF: 55% at baseline versus 70% at 4 weeks (P = 0.23). In the paced group, LV‐EDD decreased with no significant change in LV‐ESD. Unlike the control group, LVEF decreased significantly from 69 ± 9% at baseline to 32 ± 22% after 4 weeks of pacing (P = 0.05). Conclusion: We have shown that 4 weeks of coupled pacing simulating atrial bigeminy significantly reduced LV function. Our findings suggest that premature complexes independent of ventricular dyssynchrony might lead to the development of cardiomyopathy. (PACE 2012; 35:1232–1235)
- 30 July 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (10) , 1232-1235
Atrial Bigeminy Results in Decreased Left Ventricular Function: An Insight into the Mechanism of PVC‐Induced Cardiomyopathy
Background: Premature ventricular complexes have been recently recognized as a reversible cause of cardiomyopathy. The purpose of this study was to determine if premature complexes independent of “dyssynchrony” resulted in increased left ventricular (LV) dimensions and decreased LV function. Methods: Ten mongrel dogs underwent the implantation of a pacemaker and were randomized to a control group (n = 5) or a paced group (n = 5). In the paced group, the pacemaker was connected to two endocardial atrial leads, one inserted into the atrial port and the other one into the ventricular port with an atrioventricular delay adjusted to ensure the presence of coupled pacing simulating atrial bigeminy with conducted beats in the absence of aberrancy. Echocardiographic parameters of LV size (LV end‐diastolic diameter [LV‐EDD], LV end‐systolic diameter [LV‐ESD]), and LV ejection fraction (LVEF) were measured at baseline and after 4 weeks of monitoring (control group) or pacing (paced group). Results: In the control group, LV size decreased with no significant changes in LVEF: 55% at baseline versus 70% at 4 weeks (P = 0.23). In the paced group, LV‐EDD decreased with no significant change in LV‐ESD. Unlike the control group, LVEF decreased significantly from 69 ± 9% at baseline to 32 ± 22% after 4 weeks of pacing (P = 0.05). Conclusion: We have shown that 4 weeks of coupled pacing simulating atrial bigeminy significantly reduced LV function. Our findings suggest that premature complexes independent of ventricular dyssynchrony might lead to the development of cardiomyopathy. (PACE 2012; 35:1232–1235)
- 13 June 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (8) , 973-979
Atrial Fibrillation: An Independent Risk Factor for Nonaccidental Falls in Older Patients
Background: Nonaccidental falls are often the result of a combination of factors including cardiovascular disorders such as orthostatic hypotension and unspecified cardiac arrhythmias. The objective of this study was to determine if there is an association between atrial fibrillation (AF) and nonaccidental falls. Methods: We reviewed the records of 442 consecutive patients >65 years old who presented to the Emergency Department at the University of Utah Medical Center with a complaint of fall. Results: Two‐hundred eleven patients presented with nonaccidental fall, 231 patients with accidental fall. Patients with nonaccidental fall were more likely to be older, have a history of hypertension and neurological disorders, and taking five or more medications when compared to patients with accidental fall. Despite a similar prevalence of sinus rhythm at presentation, the prevalence of a history of AF was significantly higher in patients with nonaccidental fall compared to patients with accidental fall (26% vs 15%; P = 0.003). After adjusting for clinically and statistically significant predictors with a multivariate logistic regression analysis, AF, neurological disorders, and age ≤81 years were independent predictors of nonaccidental fall. In patients ≤81 years old (median age), the risk of nonaccidental falls was 2.5 times greater in patients with a history of AF when compared to those without a history of AF (odds ratio = 2.53 [confidence interval 95% 1.3–5], P = 0.007). Conclusion: AF is an independent risk factor for nonaccidental falls. Our results emphasize the need to screen for AF in patients presenting with nonaccidental fall.(PACE 2012; 35:973–979)
- 13 June 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (8) , 973-979
Atrial Fibrillation: An Independent Risk Factor for Nonaccidental Falls in Older Patients
Background: Nonaccidental falls are often the result of a combination of factors including cardiovascular disorders such as orthostatic hypotension and unspecified cardiac arrhythmias. The objective of this study was to determine if there is an association between atrial fibrillation (AF) and nonaccidental falls. Methods: We reviewed the records of 442 consecutive patients >65 years old who presented to the Emergency Department at the University of Utah Medical Center with a complaint of fall. Results: Two‐hundred eleven patients presented with nonaccidental fall, 231 patients with accidental fall. Patients with nonaccidental fall were more likely to be older, have a history of hypertension and neurological disorders, and taking five or more medications when compared to patients with accidental fall. Despite a similar prevalence of sinus rhythm at presentation, the prevalence of a history of AF was significantly higher in patients with nonaccidental fall compared to patients with accidental fall (26% vs 15%; P = 0.003). After adjusting for clinically and statistically significant predictors with a multivariate logistic regression analysis, AF, neurological disorders, and age ≤81 years were independent predictors of nonaccidental fall. In patients ≤81 years old (median age), the risk of nonaccidental falls was 2.5 times greater in patients with a history of AF when compared to those without a history of AF (odds ratio = 2.53 [confidence interval 95% 1.3–5], P = 0.007). Conclusion: AF is an independent risk factor for nonaccidental falls. Our results emphasize the need to screen for AF in patients presenting with nonaccidental fall.(PACE 2012; 35:973–979)
- 11 April 2012
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 23 (7) , 722-726
Restoring Sinus Rhythm Results in Blood Pressure Reduction in Patients with Persistent Atrial Fibrillation and a History of Hypertension
Effects of Rhythm Control on Blood Pressure.Introduction: The long‐term effects of atrial fibrillation (AF) on blood pressure (BP) in patients with hypertension (HTN) remain unclear. We hypothesized that restoration of normal sinus rhythm (NSR) results in a decrease in BP despite the expected increase in cardiac output.Methods and Results: Twenty‐four‐hour BP measurements were obtained during AF, and on Day 1 and Day 30 post‐successful cardioversion in 18 patients with AF and HTN (cardioversion group), and another 22 patients with AF and HTN with no immediate plans for cardioversion (control group). Except for the duration of AF, the clinical characteristics and use of medications were similar between the groups. In the cardioversion group, a significant decrease in diastolic blood pressure (DBP) and mean blood pressure (MBP) were noted on Day 1 post‐cardioversion with no significant change in systolic blood pressure (SBP): 117/74/88 ± 13/9/9 mmHg during AF and 116/70/85 ± 13/9/10 mmHg during Day 1 post‐cardioversion (P = 0.68; Conclusion: Restoring NSR in patients with AF and HTN resulted in a sustained decrease in DBP and MBP. To our knowledge, this is the first study to show that maintenance of NSR improves BP control in patients with AF and HTN. (J Cardiovasc Electrophysiol, Vol. 23, pp. 722‐726, July 2012)
- 11 April 2012
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 23 (7) , 722-726
Restoring Sinus Rhythm Results in Blood Pressure Reduction in Patients with Persistent Atrial Fibrillation and a History of Hypertension
Effects of Rhythm Control on Blood Pressure.Introduction: The long‐term effects of atrial fibrillation (AF) on blood pressure (BP) in patients with hypertension (HTN) remain unclear. We hypothesized that restoration of normal sinus rhythm (NSR) results in a decrease in BP despite the expected increase in cardiac output.Methods and Results: Twenty‐four‐hour BP measurements were obtained during AF, and on Day 1 and Day 30 post‐successful cardioversion in 18 patients with AF and HTN (cardioversion group), and another 22 patients with AF and HTN with no immediate plans for cardioversion (control group). Except for the duration of AF, the clinical characteristics and use of medications were similar between the groups. In the cardioversion group, a significant decrease in diastolic blood pressure (DBP) and mean blood pressure (MBP) were noted on Day 1 post‐cardioversion with no significant change in systolic blood pressure (SBP): 117/74/88 ± 13/9/9 mmHg during AF and 116/70/85 ± 13/9/10 mmHg during Day 1 post‐cardioversion (P = 0.68; Conclusion: Restoring NSR in patients with AF and HTN resulted in a sustained decrease in DBP and MBP. To our knowledge, this is the first study to show that maintenance of NSR improves BP control in patients with AF and HTN. (J Cardiovasc Electrophysiol, Vol. 23, pp. 722‐726, July 2012)
- 31 December 2011
- Published by Elsevier in Journal of Electrocardiology
- Vol. 44 (6) , 796-797
Postoperative bigeminy: what is the mechanism?
- 31 December 2011
- Published by Elsevier in Journal of Electrocardiology
- Vol. 44 (6) , 796-797
Postoperative bigeminy: what is the mechanism?
- Open Access
- 14 July 2011
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (11) , 1632-1638
Syncope in the emergency department: comparison of standardized admission criteria with clinical practice
Syncope is a major health care problem that accounts for many emergency department (ED) and hospital admissions. This study was conducted to investigate the short-term risk of serious events in patients presenting to the ED with syncope and to compare guideline-based admission criteria with those adopted in clinical practice. A single-centre retrospective analysis was performed on ED visits between January and June 2009. We used the ICD-9 code 780.2 for syncope as the primary diagnosis. The prevalence of serious events within 7 days of the index presentation was evaluated. In addition, admissions and discharges were classified as being appropriate or inappropriate based on standardized guideline-based criteria integrated in a new Faint-Algorithm developed at the University of Utah. Two hundred and fifty-four ED visits met the inclusion criteria. One hundred and thirty-six patients were discharged home and the remaining 118 were admitted. The prevalence of serious events in the discharged and admission groups were 5 and 10, respectively, (P= NS). According to the Faint-Algorithm, the number of inappropriate discharges and admissions were 8 out of 136 and 69 out of 118, respectively. Using the Faint-Algorithm, only 57 patients instead of 118 patients should have been admitted resulting in a 52% reduction in admission rate. Furthermore, in the remaining 197 patients who should have been discharged, the prevalence of serious events was not significantly different than that observed in the 136 patients who were actually discharged (3% vs. 4%). There are significant numbers of inappropriate discharges and admissions in patients presenting with syncope. The standardized guideline-based criteria integrated in the new Faint-Algorithm provide promise but require further prospective evaluation.
- 14 July 2011
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (11) , 1632-1638
Open AccessSyncope in the emergency department: comparison of standardized admission criteria with clinical practice
Syncope is a major health care problem that accounts for many emergency department (ED) and hospital admissions. This study was conducted to investigate the short-term risk of serious events in patients presenting to the ED with syncope and to compare guideline-based admission criteria with those adopted in clinical practice. A single-centre retrospective analysis was performed on ED visits between January and June 2009. We used the ICD-9 code 780.2 for syncope as the primary diagnosis. The prevalence of serious events within 7 days of the index presentation was evaluated. In addition, admissions and discharges were classified as being appropriate or inappropriate based on standardized guideline-based criteria integrated in a new Faint-Algorithm developed at the University of Utah. Two hundred and fifty-four ED visits met the inclusion criteria. One hundred and thirty-six patients were discharged home and the remaining 118 were admitted. The prevalence of serious events in the discharged and admission groups were 5 and 10, respectively, (P= NS). According to the Faint-Algorithm, the number of inappropriate discharges and admissions were 8 out of 136 and 69 out of 118, respectively. Using the Faint-Algorithm, only 57 patients instead of 118 patients should have been admitted resulting in a 52% reduction in admission rate. Furthermore, in the remaining 197 patients who should have been discharged, the prevalence of serious events was not significantly different than that observed in the 136 patients who were actually discharged (3% vs. 4%). There are significant numbers of inappropriate discharges and admissions in patients presenting with syncope. The standardized guideline-based criteria integrated in the new Faint-Algorithm provide promise but require further prospective evaluation.
- 10 June 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (11) , 1249-1252
Irregular Ventricular Activation Results in QT Prolongation and Increased QT Dispersion: A New Insight Into the Mechanism of AF-Induced Ventricular Arrhythmogenesis
Effects of Irregular Pacing on Repolarization. Introduction: Atrial fibrillation (AF) has been shown to be associated with increased risk of ventricular arrhythmias. We have previously shown reverse electrical remodeling of the ventricles following successful restoration of sinus rhythm in patients with persistent AF. The purpose of this study was to assess the relative role of irregular ventricular activation in mediating the previously observed changes. Methods and Results: Twenty‐two patients referred for an invasive electrophysiologic study were randomized to 30 minutes of regular or irregular atrioventricular (AV) sequential pacing at 100 beats per minute (bpm) with a programmed AV interval of 100 ms. Irregular pacing was triggered from prerecorded digital signal with a mean rate of 100 bpm, and a standard deviation of 150 ms (25% of the mean rate). In the regular pacing group, QT and QTc decreased from 448 ± 102 ms and 453 ± 105 ms to 428 ± 109 ms and 442 ± 104 ms, respectively (P < 0.001 for QT interval and P < 0.001 for QTc interval). There was no significant change in QT dispersion. In the irregular pacing group, QT and QTc increased from 477 ± 104 ms and 486 ± 78 ms to 489 ± 106 ms and 500 ± 106 ms (P < 0.01 for QT interval and P = 0.03 for QTc interval). In addition, there was a significant increase in QT dispersion from 50 ± 22 ms to 66 ± 22 ms (P = 0.001). Since the rate and pacing sites were similar between the groups, we attribute the repolarization changes in the irregular pacing group to the irregular activation of the ventricles. Conclusion: The detrimental effects of irregular pacing go beyond the hemodynamic changes and include electrical remodeling that favors an arrhythmogenic substrate. (J Cardiovasc Electrophysiol, Vol. pp. 1‐4)
- 10 June 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (11) , 1249-1252
Irregular Ventricular Activation Results in QT Prolongation and Increased QT Dispersion: A New Insight Into the Mechanism of AF-Induced Ventricular Arrhythmogenesis
Effects of Irregular Pacing on Repolarization. Introduction: Atrial fibrillation (AF) has been shown to be associated with increased risk of ventricular arrhythmias. We have previously shown reverse electrical remodeling of the ventricles following successful restoration of sinus rhythm in patients with persistent AF. The purpose of this study was to assess the relative role of irregular ventricular activation in mediating the previously observed changes. Methods and Results: Twenty‐two patients referred for an invasive electrophysiologic study were randomized to 30 minutes of regular or irregular atrioventricular (AV) sequential pacing at 100 beats per minute (bpm) with a programmed AV interval of 100 ms. Irregular pacing was triggered from prerecorded digital signal with a mean rate of 100 bpm, and a standard deviation of 150 ms (25% of the mean rate). In the regular pacing group, QT and QTc decreased from 448 ± 102 ms and 453 ± 105 ms to 428 ± 109 ms and 442 ± 104 ms, respectively (P < 0.001 for QT interval and P < 0.001 for QTc interval). There was no significant change in QT dispersion. In the irregular pacing group, QT and QTc increased from 477 ± 104 ms and 486 ± 78 ms to 489 ± 106 ms and 500 ± 106 ms (P < 0.01 for QT interval and P = 0.03 for QTc interval). In addition, there was a significant increase in QT dispersion from 50 ± 22 ms to 66 ± 22 ms (P = 0.001). Since the rate and pacing sites were similar between the groups, we attribute the repolarization changes in the irregular pacing group to the irregular activation of the ventricles. Conclusion: The detrimental effects of irregular pacing go beyond the hemodynamic changes and include electrical remodeling that favors an arrhythmogenic substrate. (J Cardiovasc Electrophysiol, Vol. pp. 1‐4)
- 7 May 2011
- Published by Springer Nature in Clinical Autonomic Research
- Vol. 21 (5) , 325-332
Oscillatory vagal maneuvers produce ventricular entrainment in patients with atrial fibrillation
Atrial fibrillation (AF) is the most common sustained dysrhythmia and appears to be an independent predictor of sudden cardiac death. The irregular ventricular rhythm contains both linear and non-linear patterns; however, it remains unclear whether vagally mediated effects are present within these patterns. We sought to determine if (1) power spectral analysis of heart rate can detect changes in vagal activity in patients with AF and (2) if the vagus modulates ventricular response during AF. Time and frequency domain parameters of heart rate variability (HRV) were calculated during forced vagal oscillations at 0.125 and 0.25 Hz imposed by neck suction and deep breathing in five AF patients. There was a significant increase in SDRRI during deep breathing/neck suction combined compared to baseline (p = 0.01) and deep breathing (p = 0.03). Neck suction significantly increased SDRRI compared to baseline (p = 0.03). Deep breathing/neck suction significantly increased spectral power compared to baseline (p = 0.02) and deep breathing (p = 0.03). Neck suction significantly increased spectral power compared to baseline (p = 0.03). Deep breathing did not significantly increase HRV compared to baseline (p > 0.20). In addition, SDRRI and spectral power were significantly correlated during deep breathing (r = 0.91, p = 0.03) and deep breathing/neck suction combined (r = 0.92, p = 0.02). These data suggest that (1) power spectral analysis can detect vagal influences on heart rate in AF patients, and (2) oscillatory vagal maneuvers produce ventricular entrainment during AF.
- 7 May 2011
- Published by Springer Nature in Clinical Autonomic Research
- Vol. 21 (5) , 325-332
Oscillatory vagal maneuvers produce ventricular entrainment in patients with atrial fibrillation
Atrial fibrillation (AF) is the most common sustained dysrhythmia and appears to be an independent predictor of sudden cardiac death. The irregular ventricular rhythm contains both linear and non-linear patterns; however, it remains unclear whether vagally mediated effects are present within these patterns. We sought to determine if (1) power spectral analysis of heart rate can detect changes in vagal activity in patients with AF and (2) if the vagus modulates ventricular response during AF. Time and frequency domain parameters of heart rate variability (HRV) were calculated during forced vagal oscillations at 0.125 and 0.25 Hz imposed by neck suction and deep breathing in five AF patients. There was a significant increase in SDRRI during deep breathing/neck suction combined compared to baseline (p = 0.01) and deep breathing (p = 0.03). Neck suction significantly increased SDRRI compared to baseline (p = 0.03). Deep breathing/neck suction significantly increased spectral power compared to baseline (p = 0.02) and deep breathing (p = 0.03). Neck suction significantly increased spectral power compared to baseline (p = 0.03). Deep breathing did not significantly increase HRV compared to baseline (p > 0.20). In addition, SDRRI and spectral power were significantly correlated during deep breathing (r = 0.91, p = 0.03) and deep breathing/neck suction combined (r = 0.92, p = 0.02). These data suggest that (1) power spectral analysis can detect vagal influences on heart rate in AF patients, and (2) oscillatory vagal maneuvers produce ventricular entrainment during AF.
- 22 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 284-290
Evaluation of Patients with “Faint” in an American Teaching Hospital: A Dire Need for a Standardized Approach
Fainting is a major healthcare problem with significant morbidity, mortality, and healthcare cost. We sought to assess the appropriateness of current clinical practice when compared to a guideline-based algorithm. The records of 100 consecutive patients who presented with faint and were referred to the University of Utah for further evaluation by specialists were reviewed. We analyzed the clinical characteristics, tests performed, diagnosis made, and number of admissions. In addition, we applied a guideline-based algorithm to assess the appropriateness of these evaluations. The mean age was 49 ± 21 years with 57% being female. One-third presented with their first event. Structural heart disease was present in 22% of the cases. Twelve (36%) of 32 admissions were inappropriate. There was an underutilization of orthostatic testing, carotid sinus massage, and implantable loop recorder and overutilization of imaging studies and neurologic consultation. Specifically, active standing and tilt-table testing were performed in only 24% and 7% of the cases, respectively, none of the patients had carotid sinus massage despite 26% of them being ≥65 years old, and only 3% of the patients received an implantable loop recorder. With the current practice, a final diagnosis was made in 45 cases with 17 (38%) of the 45 final diagnoses not being sufficiently supported by the completeness of the evaluation. With the current practice at a major university hospital, the cause of faint was unexplained in a high number of cases. Our findings highlight the need for a standardized approach to patients presenting with faint.
- 22 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 284-290
Evaluation of Patients with “Faint” in an American Teaching Hospital: A Dire Need for a Standardized Approach
Fainting is a major healthcare problem with significant morbidity, mortality, and healthcare cost. We sought to assess the appropriateness of current clinical practice when compared to a guideline-based algorithm. The records of 100 consecutive patients who presented with faint and were referred to the University of Utah for further evaluation by specialists were reviewed. We analyzed the clinical characteristics, tests performed, diagnosis made, and number of admissions. In addition, we applied a guideline-based algorithm to assess the appropriateness of these evaluations. The mean age was 49 ± 21 years with 57% being female. One-third presented with their first event. Structural heart disease was present in 22% of the cases. Twelve (36%) of 32 admissions were inappropriate. There was an underutilization of orthostatic testing, carotid sinus massage, and implantable loop recorder and overutilization of imaging studies and neurologic consultation. Specifically, active standing and tilt-table testing were performed in only 24% and 7% of the cases, respectively, none of the patients had carotid sinus massage despite 26% of them being ≥65 years old, and only 3% of the patients received an implantable loop recorder. With the current practice, a final diagnosis was made in 45 cases with 17 (38%) of the 45 final diagnoses not being sufficiently supported by the completeness of the evaluation. With the current practice at a major university hospital, the cause of faint was unexplained in a high number of cases. Our findings highlight the need for a standardized approach to patients presenting with faint.
- 11 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 291-295
An Animal Model for Ectopy‐Induced Cardiomyopathy
Ectopy-induced cardiomyopathy is an increasingly recognized cause of reversible left ventricular (LV) dysfunction. The underlying mechanisms remain unknown. Our goal was to create an animal model for ectopy-induced cardiomyopathy. Eleven mongrel dogs underwent the implantation of a dual-chamber pacemaker. Four dogs served as the control group and seven as the paced group. In the paced group, the pacemaker was connected to two endocardial right ventricular leads, one inserted into the atrial port and the other one into the ventricular port with an atrioventricular delay adjusted to ensure the presence of coupled pacing simulating ventricular bigeminy. Echocardiographic measurements of LV size (LV end-diastolic diameter [LV-EDD], LV end-systolic diameter [LV-ESD]), LV ejection fraction (LVEF), and mitral regurgitation (MR) were obtained at baseline and after 4 weeks of monitoring or pacing in all dogs except one who had lead dislodgement. In the control group (n = 4), no significant changes in LV dimensions or function were noted. In the paced group (n = 6), LV-EDD and LV-ESD increased from 3.58 ± 0.65 cm and 2.47 ± 0.55 cm to 4.15 ± 0.59 cm and 3.21 ± 0.47 cm, respectively (P < 0.01). In addition, LVEF decreased from 60 ± 7% to 46 ± 9% (P < 0.05). No changes in MR were noted. We have shown that coupled pacing simulating ventricular bigeminy was feasible and resulted in increased LV dimensions and decreased LV function. By controlling the percentage of pacing, the coupling interval and the location of the pacing lead, this new model will allow the assessment of the relative roles of these variables in the development of ectopy-induced cardiomyopathy.
- 11 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 291-295
An Animal Model for Ectopy‐Induced Cardiomyopathy
Ectopy-induced cardiomyopathy is an increasingly recognized cause of reversible left ventricular (LV) dysfunction. The underlying mechanisms remain unknown. Our goal was to create an animal model for ectopy-induced cardiomyopathy. Eleven mongrel dogs underwent the implantation of a dual-chamber pacemaker. Four dogs served as the control group and seven as the paced group. In the paced group, the pacemaker was connected to two endocardial right ventricular leads, one inserted into the atrial port and the other one into the ventricular port with an atrioventricular delay adjusted to ensure the presence of coupled pacing simulating ventricular bigeminy. Echocardiographic measurements of LV size (LV end-diastolic diameter [LV-EDD], LV end-systolic diameter [LV-ESD]), LV ejection fraction (LVEF), and mitral regurgitation (MR) were obtained at baseline and after 4 weeks of monitoring or pacing in all dogs except one who had lead dislodgement. In the control group (n = 4), no significant changes in LV dimensions or function were noted. In the paced group (n = 6), LV-EDD and LV-ESD increased from 3.58 ± 0.65 cm and 2.47 ± 0.55 cm to 4.15 ± 0.59 cm and 3.21 ± 0.47 cm, respectively (P < 0.01). In addition, LVEF decreased from 60 ± 7% to 46 ± 9% (P < 0.05). No changes in MR were noted. We have shown that coupled pacing simulating ventricular bigeminy was feasible and resulted in increased LV dimensions and decreased LV function. By controlling the percentage of pacing, the coupling interval and the location of the pacing lead, this new model will allow the assessment of the relative roles of these variables in the development of ectopy-induced cardiomyopathy.
- 4 October 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 278-283
The Prevalence and Cost of the Faint and Fall Problem in the State of Utah
Understanding the frequency and economic impact of faint and fall is a prerequisite for the creation of cost-effective diagnostic approaches. We evaluated the total number of patients presenting with faint or fall to the University of Utah Health Care System between November 1, 2008, and October 31, 2009. Using these data, we estimated the prevalence and total cost of the faint and fall problem in the state of Utah. A total of 1,936 and 6,043 patients presented with faint and fall resulting in a total number of visits equal to 2,701 and 8,163, respectively. The yearly prevalence of faints was 9.5 patients (13.2 visits) per 1,000 inhabitants and the yearly prevalence of falls was 29.8 patients (40.2 visits) per 1,000 inhabitants. The prevalence of faints and falls progressively increased with age, reaching the values of 40 and 115 per 1,000 inhabitants in subjects aged >80 years. In both patient populations, two-thirds of visits were outpatient evaluations. While the cardiovascular service was involved in the outpatient evaluation of faint visits in 24% of the cases, <1% of outpatient fall visits resulted in a cardiovascular consultation. The average payments received per faint and fall patient evaluations were $2,517 and $3,200, respectively, resulting in an estimated yearly cost equal to $90,901,958 and $351,959,040, respectively. This study highlights the magnitude of the faint and fall problem in the state of Utah. Our results provide all stakeholders with a frame of reference for the creation of cost-effective diagnostic approaches.
- 4 October 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 278-283
The Prevalence and Cost of the Faint and Fall Problem in the State of Utah
Understanding the frequency and economic impact of faint and fall is a prerequisite for the creation of cost-effective diagnostic approaches. We evaluated the total number of patients presenting with faint or fall to the University of Utah Health Care System between November 1, 2008, and October 31, 2009. Using these data, we estimated the prevalence and total cost of the faint and fall problem in the state of Utah. A total of 1,936 and 6,043 patients presented with faint and fall resulting in a total number of visits equal to 2,701 and 8,163, respectively. The yearly prevalence of faints was 9.5 patients (13.2 visits) per 1,000 inhabitants and the yearly prevalence of falls was 29.8 patients (40.2 visits) per 1,000 inhabitants. The prevalence of faints and falls progressively increased with age, reaching the values of 40 and 115 per 1,000 inhabitants in subjects aged >80 years. In both patient populations, two-thirds of visits were outpatient evaluations. While the cardiovascular service was involved in the outpatient evaluation of faint visits in 24% of the cases, <1% of outpatient fall visits resulted in a cardiovascular consultation. The average payments received per faint and fall patient evaluations were $2,517 and $3,200, respectively, resulting in an estimated yearly cost equal to $90,901,958 and $351,959,040, respectively. This study highlights the magnitude of the faint and fall problem in the state of Utah. Our results provide all stakeholders with a frame of reference for the creation of cost-effective diagnostic approaches.