Benoît Villemant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benoît Villemant has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Agnès Michel
Laboratoire de Géochimie des Systèmes Volcaniques, Institut de Physique du Globe, Université Pierre et Marie Curie, CNRS-UMR 7046, Boîte 109, 4 place Jussieu, 75005 Paris, France
1 shared publication
Latest Publications
- 1 July 2003
- Published by Wiley in Geostandards Newsletter
- Vol. 27 (2) , 163-171
Determination of Halogens (F, Cl, Br, I), Sulfur and Water in Seventeen Geological Reference Materials
Fluorine, chlorine, bromine, iodine and sulfur were determined in seventeen geological reference materials after extraction by pyrohydrolysis. Fluorine, Cl and S (as sulfate ions) were determined in the extraction solution by ion chromatography with detection limits of around 0.2 mg l−1. Bromine and I were measured by ICP‐MS with detection limits of 1 μg l−1 for Br and 0.1 μg l−1 for I. For rock samples, using normal extraction conditions (500 mg of sample and 100 ml of final solution) detection limits were 40 mg kg−1 for F and Cl, 15 mg kg−1 for S, 0.2 mg kg−1 for Br and 0.02 mg kg−1 for I. These detection limits may be improved by increasing the amount of sample and hence the concentration of the final solution. Water was also determined using an extraction technique based on H2O degassing, reduction on zinc at 1000 °C and H2 manometry. Our results for fluorine, chlorine, sulfur and water are in good agreement with literature data. Very few reference materials have recommended values for bromine and especially for iodine. Among the analysed samples, three are new reference materials: BHVO‐2, BCR‐2 and AGV‐2.
- 1 July 2003
- Published by Wiley in Geostandards Newsletter
- Vol. 27 (2) , 163-171
Determination of Halogens (F, Cl, Br, I), Sulfur and Water in Seventeen Geological Reference Materials
Fluorine, chlorine, bromine, iodine and sulfur were determined in seventeen geological reference materials after extraction by pyrohydrolysis. Fluorine, Cl and S (as sulfate ions) were determined in the extraction solution by ion chromatography with detection limits of around 0.2 mg l−1. Bromine and I were measured by ICP‐MS with detection limits of 1 μg l−1 for Br and 0.1 μg l−1 for I. For rock samples, using normal extraction conditions (500 mg of sample and 100 ml of final solution) detection limits were 40 mg kg−1 for F and Cl, 15 mg kg−1 for S, 0.2 mg kg−1 for Br and 0.02 mg kg−1 for I. These detection limits may be improved by increasing the amount of sample and hence the concentration of the final solution. Water was also determined using an extraction technique based on H2O degassing, reduction on zinc at 1000 °C and H2 manometry. Our results for fluorine, chlorine, sulfur and water are in good agreement with literature data. Very few reference materials have recommended values for bromine and especially for iodine. Among the analysed samples, three are new reference materials: BHVO‐2, BCR‐2 and AGV‐2.