JFJoachim W. Fluhr

Joachim W. Fluhr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joachim W. Fluhr has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • P. Elsner

    5 shared publications
  • P. Kleesz

    Skin Physiology Laboratory, Department of Dermatology and Allergology, Friedrich-Schiller-University, Erfurter Str. 35, 07740 Jena, Germany *Institution for Statutory Accident Insurance and Prevention in the Food Processing Industry and Catering Trade (BGN), Mannheim, Germany

    3 shared publications
  • R. Grieshaber

    Skin Physiology Laboratory, Department of Dermatology and Allergology, Friedrich-Schiller-University, Erfurter Str. 35, 07740 Jena, Germany *Institution for Statutory Accident Insurance and Prevention in the Food Processing Industry and Catering Trade (BGN), Mannheim, Germany

    3 shared publications
  • A. Akengin

    Skin Physiology Laboratory, Department of Dermatology and Allergology, Friedrich-Schiller-University, Erfurter Str. 35, 07740 Jena, Germany *Institution for Statutory Accident Insurance and Prevention in the Food Processing Industry and Catering Trade (BGN), Mannheim, Germany

    2 shared publications
  • A. Bornkessel

    Skin Physiology Laboratory, Department of Dermatology and Allergology, Friedrich-Schiller-University, Erfurter Str. 35, 07740 Jena, Germany *Institution for Statutory Accident Insurance and Prevention in the Food Processing Industry and Catering Trade (BGN), Mannheim, Germany

    2 shared publications
  • David G. Moskowitz

    Dermatology and Medical Service, Veterans Affairs Medical Center, San Francisco, California, USA

    2 shared publications

Latest Publications

  • Functional Assessment of a Skin Care System in Patients on Chemotherapy

    by J.W. Fluhr, M. Miteva, G. Primavera, M. Ziemer, P. Elsner, E. Berardesca

    Background/Purpose: Cancer patients undergoing chemotherapy frequently experience skin problems such as xerosis. The aim of this study was to verify whether a concomitant treatment with an acidic washing and an acidic emollient (both pH 5.5) can significantly improve the quality of the skin in such patients. Methods: 30 adult patients on chemotherapy experiencing dry and sensitive skin were included in a controlled, monocentric, 3-week treatment trial. One forearm served as a test site, the other one remained untreated. Noninvasive biophysical measurements were performed at baseline, on days 7, 14 and 21, along with clinical evaluation of the skin symptoms. Results: After a 3-week treatment, a significant increase in stratum corneum hydration was recorded in the treated site (p < 0.001). Reduced transepidermal water loss values, consistent with a restored barrier function, were obtained (p < 0.001). Casual sebum levels as measured by sebumetry showed a significant increase (p < 0.03). All skin symptoms investigated revealed a considerable improvement over 3 weeks. Conclusion: Controlled and regular use of a skin care system, especially an acidic one, improved skin physiology in patients undergoing chemotherapy.


    • 8 February 2007
      • Vol. 149  (6) , 38-9

    [From research to practice: skin care--merely empiric?].

    by J Fluhr, P Elsner

    A modern skin care concept involving physiological lipids should be matched to the state of the skin, the season of the year and the presence of dermatoses. Also desirable would be substances that regulate the moisture status and barrier function of the stratum corneum, e.g. glycerin, in relevant concentrations. Of central importance in diseases associated with destruction of the uppermost layer of the skin, for example, neurodermatitis, is regular skin care with moisturizing products and a lipid composition that is as physiological as possible. In addition, the water and lipoid content of the skin care formulation should be matched to disease stage and the season of the year.

  • The Price for Treatment of Chronic Skin Diseases: Different Approaches

    by Joachim W. Fluhr, Michael Jünger


  • Approaches for optimizing the calibration standard of Tewameter TM 300

    by Maria Miteva, Stefan Richter, Peter Elsner, Joachim W. Fluhr

    Abstract: Calibration of devices measuring transepidermal water loss (TEWL) is in intensive discussion. Comparative studies revealed that comparable measuring systems, e.g. open and closed chamber systems, do not always deliver the same results, even when expressing the measured values in SI units, namely in g/m2/h. Therefore, adequate and reliable calibration procedures need to be established. We were able to test the reliability of a multi‐step calibration algorithm for an open chamber system such as Tewameter TM 300. In order to achieve reliable measurements, the maintenance of stable microclimate conditions without air turbulences is mandatory. The TEWL values should be compared with those determined gravimetrically on heated skin simulators. The reproducibility of the results is warranted by consecutive measurements on different adjacent spots of a defined area. Preheating of the probe sensors is an effective approach for shortening the measuring time and gaining a rapid steady‐state. The accurate calibration of the probe can be checked under laboratory conditions any time. The critical point of the calibration and ultimately the accuracy of in vivo measurements maintain the steady functional capacity of the probes during the entire duration of continuous studies. The studied calibration procedure ensures these requirements.


  • Topical Liver X Receptor Activators Accelerate Postnatal Acidification of Stratum Corneum and Improve Function in the Neonate

    by Joachim W. Fluhr, Debra Crumrine, Man Mao-Qiang, David G. Moskowitz, Peter M. Elias, Kenneth R. Feingold


  • Additive impairment of the barrier function by mechanical irritation, occlusion and sodium lauryl sulphate in vivo

    by J.W. Fluhr, A. Akengin, A. Bornkessel, S. Fuchs, J. Praessler, J. Norgauer, R. Grieshaber, P. Kleesz, P. Elsner

    Background The interaction between potential irritants in the workplace might be important because workers are not usually exposed to a single irritant, but to multiple potentially harmful substances. Physical irritant contact dermatitis caused by friction or mechanical abrasion is a common occupational dermatosis. Prolonged water exposure by occlusion is also common in the workplace. Several studies have revealed the negative effect of the common anionic detergent sodium lauryl sulphate (SLS) on permeability barrier function. Objectives To study the additive impairment of permeability barrier function by mechanical irritation combined with 0·5% SLS or prolonged water exposure by occlusion, as models of mild irritation. Methods The volar forearms of 20 healthy volunteers were exposed to mechanical irritation and occlusion with water or 0·5% SLS for four consecutive days in a combined tandem repeated irritation test (TRIT). Permeability barrier function was measured with a Tewameter TM 210®. Irritation was assessed with a Chromameter CR 300® and a visual score. Results Barrier disruption in our model was rated as follows: occlusion with SLS and mechanical irritation > occlusion with SLS > occlusion with water and mechanical irritation > mechanical irritation and occlusion with water > occlusion with a glove and mechanical irritation > mechanical irritation > occlusion with water. Barrier disruption caused by occlusion or mechanical irritation was enhanced by the tandem application. The choice of irritant under occlusion, time of occlusion and order of tandem application all affected the degree of barrier disruption. Evaporimetry was able to detect early stages in the development of an irritant reaction before it became visible. Chromametry was not able to detect this early response. Conclusions Physical irritants (friction, abrasive grains, occlusion) and detergents such as SLS represent a significant irritation risk and should be minimized, especially when acting together, as shown in our TRIT model.


  • Air flow at different temperatures increases sodium lauryl sulphate-induced barrier disruption and irritation in vivo

    by J.W. Fluhr, J. Praessler, A. Akengin, S.M. Fuchs, P. Kleesz, R. Grieshaber, P. Elsner

    Combined exposure to dry climatic conditions and local heat sources together with detergents represents a common workplace situation. These conditions may support the induction of chronic barrier disruption leading subsequently to irritant contact dermatitis (ICD). To test the irritant and barrier disrupting properties of air flow at different temperatures and velocities. Using noninvasive biophysical measurements such as transepidermal water loss (TEWL) (TM 210; Courage & Khazaka, Cologne, Germany) we assessed the effects of short-term exposure to air flow at different temperatures (24 degrees C and 43 degrees C) in combination with sodium lauryl sulphate (SLS) 0.5% on the skin of 20 healthy volunteers in a tandem repeated irritation test. Chromametry was used to control the accuracy of the SLS irritation model. In our study air flow alone did not lead to a significant increase in TEWL values. Sequential treatment with air flow and SLS led to an impairment of barrier function and irritation stronger than that produced by SLS alone. The two different air flow temperatures led to different skin temperatures but had no influence on permeability barrier function. Warm air flow has an additional effect on the SLS-induced barrier disruption in a tandem irritation test with sequential exposure to SLS/air flow. This combination is suspected to promote ICD in workplace and household situations, especially in short-term applications as tested in our model.


  • Additive Impairment of the Barrier Function and Irritation by Biogenic Amines and Sodium Lauryl Sulphate: A Controlled in vivo Tandem Irritation Study

    by J.W. Fluhr, D. Kelterer, S. Fuchs, M. Kaatz, R. Grieshaber, P. Kleesz, P. Elsner

    Biogenic amines are potential irritants e.g. in fish-, meat-, milk- and egg-processing professions like cooks, butchers and bakers. The aim of this study was to test the irritative and barrier-disrupting properties of the biogenic amines ammonium hydroxide (AM), dimethylamine (DMA) and trimethylamine (TMA). A repeated sequential irritation of 30 min twice per day was performed over a total of 4 days (tandem repeated irritation test) on the back of 20 healthy volunteers of both sexes with AM, DMA, TMA and sodium lauryl sulphate (SLS). The epidermal barrier function was assessed with a Tewameter TM 210, stratum corneum surface pH was measured with a Skin-pH-Meter 900, inflammation was assessed with a Chromameter CR-300 on the a* axis for redness and a visual score was recorded. All tested biogenic amines (AM, DMA and TMA) induced a barrier disruption and a pH increase paralleled with a 1-day-delayed onset of inflammatory signs. These effects were further enhanced and accelerated by a sequential application of SLS together with the biogenic amines, and inflammation occurred earlier than with the single compounds. Acetic acid (AA) in contrast did only show mild barrier disruption and no significant inflammatory signs. Our system allowed a ranking of the different compounds in their irritative potential in the tandem irritation with SLS: SLS > NaOH > TMA > AA > AM > DMA. The results are suggestive that in the food-processing industry the simultaneous contact with biogenic amines and harmful detergents like SLS should be minimized.


  • Functional assessment of a washing emulsion for sensitive skin: mild impairment of stratum corneum hydration, pH, barrier function, lipid content, integrity and cohesion in a controlled washing test

    by A. Bornkessel, M. Flach, M. Arens‐Corell, P. Elsner, J. W. Fluhr

    Background/purpose: Sensitive skin has been described as a skin type with higher reactivity than normal skin and exaggerated reactions to external irritants. Washing with soaps is harmful for barrier‐related parameters. Cutaneous irritation induced by cleansing products under exaggerated test conditions, e.g. patch testing, is not necessarily predictive of the irritation occurring under standardized daily use conditions. The purpose of the study was to assess the effect of an improved washing solution for sensitive skin in a half‐site comparison on barrier‐related parameters.Methods: Thirty healthy volunteers with self‐reported sensitive and so‐called problematic skin performed standardized washings with a soap‐free washing emulsion with mild acidity (pH 5.5) for 3 weeks. Test areas were both forearms and the cheek. Non‐invasive biophysical measurements of the following skin parameters, epidermal permeability barrier function measured as transepidermal water loss (TEWL), stratum corneum (SC) hydration, pH value, skin surface lipids, skin temperature and SC integrity/cohesion, were assessed prior to the first washing, on days 7, 14 and 21 after beginning the washing procedure. SC cohesion was quantified using two independent methods on D‐Squame tapes: optical spectroscopy measuring the absorbance and a protein assay assessing the total protein (Bradford). Both methods showed a good correlation. SC integrity was quantified by measuring TEWL after sequential stripping with D‐Squame tapes.Results: The use of the washing emulsion led to a mild damage of the epidermal permeability barrier function with no marked difference to water application. Furthermore, a mild but significant dehydration was assessed after 21 days vs. baseline without any differences between the water‐treated and the washing emulsion‐treated forearm. On the cheek no dehydration was detectable but the lipid content was reduced under the washing emulsion. The pH value increased in all three test areas after 21 days, again without significant differences between water and the washing solution. SC cohesion was quantified using two independent methods on D‐Squame tapes: optical spectroscopy measuring the absorbance and a protein assay assessing the total protein (Bradford). Both methods showed a good correlation. The SC cohesion decreased after 21 days on the water‐treated as well as on the washing emulsion‐treated arm. The decrease over time was significant when used the optical spectroscopy measuring. A standardized questionnaire revealed positive characteristics of the washing emulsion and good acceptance.Conclusion: The investigated standardized washing model with the endpoints epidermal barrier function, SC hydration, surface pH, skin surface lipids, skin temperature and SC integrity/cohesion showed only mild damage comparable to washing with water.


  • Functional Consequences of a Neutral pH in Neonatal Rat Stratum Corneum

    by Joachim W. Fluhr, Man Mao-Qiang, Barbara E. Brown, Jean-Pierre Hachem, David G. Moskowitz, Marianne Demerjian, Marek Haftek, Guy Serre, Debra Crumrine, Theodora M. Mauro, et al.