R. Jutabha
Research Subjects
R. Jutabha has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
A. Manuyakorn
Department of Pathology, David Geffen School of Medicine at University of California, Los Angeles, California, USA
1 shared publicationD. Chavalitdhamrong
Center of Ulcer Research and Education (CURE): Digestive Diseases Research Center, Los Angeles, California, USA
1 shared publicationD. M. Jensen
Center of Ulcer Research and Education (CURE): Digestive Diseases Research Center, Los Angeles, California, USA
1 shared publicationG. Chen
UCLA Center for Small-Bowel Diseases, UCLA Medical Center, Los Angeles, California 90095-1684, USA
1 shared publicationG. Cortina
Department of Pathology, David Geffen School of Medicine at University of California, Los Angeles, California, USA
1 shared publicationJ. Herman
Center of Ulcer Research and Education, Digestive Diseases Research Center, Los Angeles, California, USA
1 shared publication
Latest Publications
- 28 February 2011
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 43 (04) , 365-368
The significance of gastric and duodenal histological ischemia reported on endoscopic biopsy
Although frequently reported, it is unknown whether pathological reports of ischemia obtained from gastroduodenal biopsies suggest a diagnosis, prognosis or a requirement for additional evaluation. The aim of this study was to review the natural history, clinical presentation, endoscopic appearance, treatments, and major clinical outcomes of patients with gastroduodenal ischemia. A case series of 14 patients with variable etiologies (seven gastric and seven duodenal) was obtained from a search of our endoscopic pathological database for reports of histological ischemia. The results were as follows. The most common presentation was upper gastrointestinal bleeding (71 %). Half of the endoscopic lesions appeared very severe (large or circumferential lesions, exudative, pseudomembranous, black or pale mucosa). There were six cases of rebleeding (43 %) and four deaths (29 %). Computed tomography scanning was frequently used (12 cases, 86 %), but led to an underlying diagnosis in only three cases. In our series, patients with underlying vascular pathology have substantial 6-month mortality (29 %).
- 28 February 2011
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 43 (04) , 365-368
The significance of gastric and duodenal histological ischemia reported on endoscopic biopsy
Although frequently reported, it is unknown whether pathological reports of ischemia obtained from gastroduodenal biopsies suggest a diagnosis, prognosis or a requirement for additional evaluation. The aim of this study was to review the natural history, clinical presentation, endoscopic appearance, treatments, and major clinical outcomes of patients with gastroduodenal ischemia. A case series of 14 patients with variable etiologies (seven gastric and seven duodenal) was obtained from a search of our endoscopic pathological database for reports of histological ischemia. The results were as follows. The most common presentation was upper gastrointestinal bleeding (71 %). Half of the endoscopic lesions appeared very severe (large or circumferential lesions, exudative, pseudomembranous, black or pale mucosa). There were six cases of rebleeding (43 %) and four deaths (29 %). Computed tomography scanning was frequently used (12 cases, 86 %), but led to an underlying diagnosis in only three cases. In our series, patients with underlying vascular pathology have substantial 6-month mortality (29 %).
- 6 June 2006
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 38 (7) , 752-754
Novel external sensor array for capsule endoscopy
Capsule endoscopy (CE) requires placement of an eight-lead sensor array over the abdomen that receives image and localization data transmitted from the capsule. The current process of applying this array to the skin has several disadvantages: firstly, it is time-consuming; secondly, it can be cumbersome for the patient; and thirdly, it is often difficult to place the leads consistently. A new external sensor array system designed to improve this process was tested. It was hypothesized that the new method would be able to receive the transmitted data adequately during CE. The new method and device were tested on an in-patient who had two sets of sensor arrays, batteries, and data recorders placed on her simultaneously. One set was placed in the standard fashion, which served as the control, while the other set was placed using the novel external method. The data provided by the two recorders were compared and the patient’s preferences were noted. The quality of the CE images provided by the two methods was identical, but the CE localization tracings were different, presumably due to movement of the gown and leads during the recording period. No signal interference was noted. The patient preferred the external device. A prepositioned external sensor array is capable of transmitting CE data without any loss in image quality, but the localization tracing differs due to movement of the external array. This new method will require testing with a larger sample size in an outpatient setting to allow full assessment of the clinical value of the new approach.
- 6 June 2006
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 38 (7) , 752-754
Novel external sensor array for capsule endoscopy
Capsule endoscopy (CE) requires placement of an eight-lead sensor array over the abdomen that receives image and localization data transmitted from the capsule. The current process of applying this array to the skin has several disadvantages: firstly, it is time-consuming; secondly, it can be cumbersome for the patient; and thirdly, it is often difficult to place the leads consistently. A new external sensor array system designed to improve this process was tested. It was hypothesized that the new method would be able to receive the transmitted data adequately during CE. The new method and device were tested on an in-patient who had two sets of sensor arrays, batteries, and data recorders placed on her simultaneously. One set was placed in the standard fashion, which served as the control, while the other set was placed using the novel external method. The data provided by the two recorders were compared and the patient’s preferences were noted. The quality of the CE images provided by the two methods was identical, but the CE localization tracings were different, presumably due to movement of the gown and leads during the recording period. No signal interference was noted. The patient preferred the external device. A prepositioned external sensor array is capable of transmitting CE data without any loss in image quality, but the localization tracing differs due to movement of the external array. This new method will require testing with a larger sample size in an outpatient setting to allow full assessment of the clinical value of the new approach.