Orhan Dogan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Orhan Dogan has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Arife Dogan
8 shared publications- Giray Bolayir
Department of Prosthodontics , Faculty of Dentistry, Cumhuriyet University , Sivas, Turkey
6 shared publications Hakan Demir
Department of Prosthodontics, Cumhuriyet University, Sivas, Turkey
6 shared publications- Koray Soygun
Department of Prosthodontics, Faculty of Dentistry Cukurova University Adana Turkey
5 shared publications Selda Keskin
4 shared publications- Berkant Özpolat
Department of Thoracic Surgery, Kirikkale University, School of Medicine, Kirikkale, Turkey
2 shared publications
Latest Publications
- Open Access
- 1 October 2018
- Published by Cumhuriyet Medical Journal in Cumhuriyet Medical Journal
- Vol. 40 (3) , 215-225
Psychopathology and sociodemographic characteristics in suicide attempters: a single center study
- 1 October 2018
- Published by Cumhuriyet Medical Journal in Cumhuriyet Medical Journal
- Vol. 40 (3) , 215-225
Open AccessPsychopathology and sociodemographic characteristics in suicide attempters: a single center study
- Open Access
- 1 January 2015
- Published by ScopeMed in Applied Medical Research
- Vol. 1 (2) , 56
A Different Approach to Chest Tube Drainage after Cardiac Surgery: A Study on the Usage of a Single versus Separate Drain Vials
- 1 January 2015
- Published by ScopeMed in Applied Medical Research
- Vol. 1 (2) , 56
Open AccessA Different Approach to Chest Tube Drainage after Cardiac Surgery: A Study on the Usage of a Single versus Separate Drain Vials
- 1 January 2013
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 25 (14) , 8079-8081
Effects of the Different Methacrylate Monomers on Bond Strength Between Soft Liner and Acrylic Resin
- 1 January 2013
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 25 (14) , 8079-8081
Effects of the Different Methacrylate Monomers on Bond Strength Between Soft Liner and Acrylic Resin
- Open Access
- 15 August 2012
- Published by Kosuyolu Heart Journal, Health Sciences University in Kosuyolu Heart Journal
- Vol. 15 (2) , 84-86
Left Coronary Artery-Pulmonary Artery Fistula in Coronary Artery Disease
- 15 August 2012
- Published by Kosuyolu Heart Journal, Health Sciences University in Kosuyolu Heart Journal
- Vol. 15 (2) , 84-86
Open AccessLeft Coronary Artery-Pulmonary Artery Fistula in Coronary Artery Disease
- 1 December 2011
- Vol. 13 (6) , 579-584
Peel Bond Strength of Two Silicone Soft Liners to a Heat-cured Denture Base Resin
This study investigated the peel strength of two different soft liners to a polymethylmethacrylate (PMMA) denture base resin before and after thermocycling. The silicone-based soft liner materials tested were Molloplast B and Permaflex; the denture base material was a heat-cured acrylic resin, Meliodent. A total of 40 specimens was prepared using rectangular molds with dimensions of 100 x 10 x 2 mm for PMMA and 150 x 10 x 2 mm for soft liners, as described in ASTM-D903-93. For each of the liner materials, 10 specimens were packed against a cured PMMA denture base surface as recommended by the manufacturers. The other 10 specimens were packed against PMMA denture base dough and processed together. In each group, 5 of the specimens were tested directly, while the other 5 were thermocycled in a water bath (5°C to 55°C; 3000 cycles) before testing. Peel testing was performed using an Instron testing machine. The results revealed that peel strength values of the Permaflex specimens prepared according to the manufacturer's recommendations were significantly higher than those of Molloplast B (p < 0.05). However, when packing was done against uncured PMMA dough, the difference between the specimens of two liners was not significant. Thermocycling led to significant decreases in the peel strength of both Permaflex liner specimens packed against cured/uncured PMMA resin surfaces (p < 0.05), whereas this process did not affect the strength of Molloplast B specimens. Results indicated that the material Molloplast B was superior to the material Permaflex in terms of peel strength when the specimens were simultaneously polymerized with PMMA and thermocycled.
- 1 December 2011
- Vol. 13 (6) , 579-584
Peel Bond Strength of Two Silicone Soft Liners to a Heat-cured Denture Base Resin
This study investigated the peel strength of two different soft liners to a polymethylmethacrylate (PMMA) denture base resin before and after thermocycling. The silicone-based soft liner materials tested were Molloplast B and Permaflex; the denture base material was a heat-cured acrylic resin, Meliodent. A total of 40 specimens was prepared using rectangular molds with dimensions of 100 x 10 x 2 mm for PMMA and 150 x 10 x 2 mm for soft liners, as described in ASTM-D903-93. For each of the liner materials, 10 specimens were packed against a cured PMMA denture base surface as recommended by the manufacturers. The other 10 specimens were packed against PMMA denture base dough and processed together. In each group, 5 of the specimens were tested directly, while the other 5 were thermocycled in a water bath (5°C to 55°C; 3000 cycles) before testing. Peel testing was performed using an Instron testing machine. The results revealed that peel strength values of the Permaflex specimens prepared according to the manufacturer's recommendations were significantly higher than those of Molloplast B (p < 0.05). However, when packing was done against uncured PMMA dough, the difference between the specimens of two liners was not significant. Thermocycling led to significant decreases in the peel strength of both Permaflex liner specimens packed against cured/uncured PMMA resin surfaces (p < 0.05), whereas this process did not affect the strength of Molloplast B specimens. Results indicated that the material Molloplast B was superior to the material Permaflex in terms of peel strength when the specimens were simultaneously polymerized with PMMA and thermocycled.
- 1 October 2011
- Vol. 13 (5) , 481-487
Effect of Maleic Anhydride Pretreatment on Tensile Bond Strength of a Silicone Soft Liner to a Denture Base Polymer
To determine the effect of resin surface treatment with dissolved maleic anhydride in butanone added into primer on the tensile bond strength between an acrylic denture base resin and a silicone soft liner. To test tensile bond strength, standard dumbbell-shaped acrylic specimens were prepared. Five experimental groups, including the control, were tested (n = 5). Maleic anhydride solutions prepared in butanone at concentrations of 1%, 5%, 10% or 20% were then mixed with 1 ml of Primo adhesive and the mixtures were applied onto the resin bonding surfaces. Silicone liner material was applied to resin surfaces in the conventional manner. Tensile bond strength of the specimens was measured in a universal testing machine. Fractured surfaces were observed under the scanning electron microscope, and resulting chemical changes with the solutions used were analyzed spectroscopically. The highest bond strength value was obtained for the group treated with 5% maleic anhydride (2.53 ± 0.48 MPa); the lowest value was for the group treated with 20% maleic anhydride (1.59 ± 0.29 MPa). Mixed failure was the dominant type seen in the experimental groups. Spectroscopic analysis showed the interaction of the anhydride carbonyl groups with the Primo primer. The treatment of resin surfaces with maleic anhydride added to Primo adhesive effectively increased bond strength between silicone soft liner and denture base resin.
- 1 October 2011
- Vol. 13 (5) , 481-487
Effect of Maleic Anhydride Pretreatment on Tensile Bond Strength of a Silicone Soft Liner to a Denture Base Polymer
To determine the effect of resin surface treatment with dissolved maleic anhydride in butanone added into primer on the tensile bond strength between an acrylic denture base resin and a silicone soft liner. To test tensile bond strength, standard dumbbell-shaped acrylic specimens were prepared. Five experimental groups, including the control, were tested (n = 5). Maleic anhydride solutions prepared in butanone at concentrations of 1%, 5%, 10% or 20% were then mixed with 1 ml of Primo adhesive and the mixtures were applied onto the resin bonding surfaces. Silicone liner material was applied to resin surfaces in the conventional manner. Tensile bond strength of the specimens was measured in a universal testing machine. Fractured surfaces were observed under the scanning electron microscope, and resulting chemical changes with the solutions used were analyzed spectroscopically. The highest bond strength value was obtained for the group treated with 5% maleic anhydride (2.53 ± 0.48 MPa); the lowest value was for the group treated with 20% maleic anhydride (1.59 ± 0.29 MPa). Mixed failure was the dominant type seen in the experimental groups. Spectroscopic analysis showed the interaction of the anhydride carbonyl groups with the Primo primer. The treatment of resin surfaces with maleic anhydride added to Primo adhesive effectively increased bond strength between silicone soft liner and denture base resin.
- 15 September 2011
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 123 (6) , 3354-3362
Tensile properties of denture base resin reinforced with various esthetic fibers
- 15 September 2011
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 123 (6) , 3354-3362
Tensile properties of denture base resin reinforced with various esthetic fibers
- 15 September 2011
- Published by Turk Noropsikiyatri Dernegi in Archives of Neuropsychiatry
- Vol. 48 (3) , 1
Şizofrenide Potansiyel Risk Etkenleri
- 15 September 2011
- Published by Turk Noropsikiyatri Dernegi in Archives of Neuropsychiatry
- Vol. 48 (3) , 1
Şizofrenide Potansiyel Risk Etkenleri
- 7 September 2011
- Published by Taylor & Francis in The Journal of Adhesion
- Vol. 87 (9) , 951-965
The Effect of Surface Treatments on Tensile Bond Strength between a Silicone Soft Liner and a Heat-Cured Denture Base Resin
This study evaluated tensile bond strength of a denture soft lining material to a poly (methylmethacrylate) (PMMA) denture base resin subjected to different surface treatment modalities and thermocycling. The materials tested were a silicone-based liner, Molloplast B®, and a heat-cured denture base resin, MeliodentTM. The denture soft lining material was packed against cured PMMA base resin, which was smoothed; sandblasted with 250-μm Al2O3 particles; or lased with a KTP laser; or against uncured PMMA dough (n = 10). In each group, five specimens were thermocycled in a water bath (5–55°C; 3000 cycles) before testing, whereas the other five were directly tested after 24 h. A tensile test was performed using a universal testing machine. Data showed that different treatment modalities of resin surfaces affected adhesion between these two materials and the highest bond values were recorded for cured/smoothed samples under each condition tested. Thermocycling of specimens had no significant reducing effect on measured bond strength values.
- 7 September 2011
- Published by Taylor & Francis in The Journal of Adhesion
- Vol. 87 (9) , 951-965
The Effect of Surface Treatments on Tensile Bond Strength between a Silicone Soft Liner and a Heat-Cured Denture Base Resin
This study evaluated tensile bond strength of a denture soft lining material to a poly (methylmethacrylate) (PMMA) denture base resin subjected to different surface treatment modalities and thermocycling. The materials tested were a silicone-based liner, Molloplast B®, and a heat-cured denture base resin, MeliodentTM. The denture soft lining material was packed against cured PMMA base resin, which was smoothed; sandblasted with 250-μm Al2O3 particles; or lased with a KTP laser; or against uncured PMMA dough (n = 10). In each group, five specimens were thermocycled in a water bath (5–55°C; 3000 cycles) before testing, whereas the other five were directly tested after 24 h. A tensile test was performed using a universal testing machine. Data showed that different treatment modalities of resin surfaces affected adhesion between these two materials and the highest bond values were recorded for cured/smoothed samples under each condition tested. Thermocycling of specimens had no significant reducing effect on measured bond strength values.
- 1 February 2011
- Vol. 13 (1) , 85-92
The Bond Strength of a Highly Cross-linked Denture Tooth to Denture Base Polymers: A Comparative Study
This study compared shear bond strength and type of bond failure between a highly cross-linked tooth and different denture base polymers. Cross-linked denture teeth were bonded to either a heat-, an auto-, a microwave-polymerized denture base resin or a relatively new injection-molded, microwave-polymerizable polyurethane-based resin. Six experimental groups were established for each of the shear and peel tests. In four of the groups, teeth were used as received and bonded to each of the denture base resins; in the remaining two groups, they were treated with dichloromethane to determine its effect on the bonding with heat or auto-polymerized denture base resins. Bond strength was determined by compressive load applied at 45 degrees on the palatal surface of each tooth until fracture; the type of bond failure was assessed by the peel test. The results showed that heat-cured PMMA groups failed cohesively and demonstrated significantly higher bond strengths than the other resins used. The application of dichloromethane on the ridge lap areas of teeth resulted in a significant improvement of bond strengths in heat- and auto-cured resins. Within the limitations of this experimental study, the results suggest that type of denture base material and processing methods may have an influence upon the bond strength between interpenetrating polymer network (IPN) denture teeth and base materials. Treatment of denture teeth with dichloromethane could provide substantial improvement in the bond strength of teeth with heat and auto-cured denture base resins; however, this finding should be validated in further investigations on the long-term effect of such treatment on the bond strength.
- 1 February 2011
- Vol. 13 (1) , 85-92
The Bond Strength of a Highly Cross-linked Denture Tooth to Denture Base Polymers: A Comparative Study
This study compared shear bond strength and type of bond failure between a highly cross-linked tooth and different denture base polymers. Cross-linked denture teeth were bonded to either a heat-, an auto-, a microwave-polymerized denture base resin or a relatively new injection-molded, microwave-polymerizable polyurethane-based resin. Six experimental groups were established for each of the shear and peel tests. In four of the groups, teeth were used as received and bonded to each of the denture base resins; in the remaining two groups, they were treated with dichloromethane to determine its effect on the bonding with heat or auto-polymerized denture base resins. Bond strength was determined by compressive load applied at 45 degrees on the palatal surface of each tooth until fracture; the type of bond failure was assessed by the peel test. The results showed that heat-cured PMMA groups failed cohesively and demonstrated significantly higher bond strengths than the other resins used. The application of dichloromethane on the ridge lap areas of teeth resulted in a significant improvement of bond strengths in heat- and auto-cured resins. Within the limitations of this experimental study, the results suggest that type of denture base material and processing methods may have an influence upon the bond strength between interpenetrating polymer network (IPN) denture teeth and base materials. Treatment of denture teeth with dichloromethane could provide substantial improvement in the bond strength of teeth with heat and auto-cured denture base resins; however, this finding should be validated in further investigations on the long-term effect of such treatment on the bond strength.