Emil H. Schemitsch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emil H. Schemitsch has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Rad Zdero
From the *Faculty of Medicine, Department of Surgery, University of Toronto, Toronto, Ontario, Canada; †Department of Anesthesia, St Michael's Hospital, Toronto, Ontario, Canada; ‡Department of Pathology, Mount Sinai Hospital, Toronto, Ontario, Canada; §Martin Orthopaedic Biomechanics Laboratory, St Michael's Hospital, Toronto, Ontario, Canada; and ‖Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
4 shared publicationsJames P. Waddell
Division of Orthopaedics, Department of Surgery, University of Toronto, St. Michael's Hospital, Suite 800, 55 Queen Street East, Toronto, ON M5C 1R6, Canada. address for E.H. Schemitsch
3 shared publicationsDuncan J. Stewart
Department of Medicine, Ottawa Hospital Research Institute and Sprott Centre for Stem Cell Research, University of Ottawa, Ottawa, Ontario, Canada
2 shared publicationsMichael D. McKee
Division of Orthopaedics, Department of Surgery, University of Toronto, Toronto, ON, Canada
2 shared publications(for the P.O.S.I.T.I.V.E. Investigators)
1 shared publication- Brad Petrisor
Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
1 shared publication
Latest Publications
- 3 July 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (13) , e91
Patient Opinions of Screening for Intimate Partner Violence in a Fracture Clinic Setting
Background: Approximately one-third of injured women presenting to fracture clinics have experienced some form of intimate partner violence in the past year. The aim of the current study was to determine patients’ perceptions on screening for intimate partner violence during visits to a surgical fracture clinic. Methods: We conducted a cross-sectional study to evaluate patients’ perceptions and opinions on screening for intimate partner violence in an orthopaedic fracture clinic. Eligible patients anonymously completed a self-reported written questionnaire, which included questions on patient demographics, attitudes toward intimate partner violence in general, the acceptability of screening for intimate partner violence in an orthopaedic fracture clinic, and opinions on how, when, and by whom the screening should be conducted. Results: The study included 750 patients (421 male and 329 female) at five clinical sites in Canada and the Netherlands. The majority (554, 73.9%) of the respondents either “agreed” or “strongly agreed” that the fracture clinic was a good place for health-care providers to ask about intimate partner violence. The majority (671, 89.5%) also agreed that health-care providers should screen for intimate partner violence by means of face-to-face interactions rather than other, more passive methods. Increased openness to screening was significantly associated with female sex, higher income, and higher education (F3595 = 21.950, p < 0.001). Conclusions: Our findings demonstrated that the majority of patients endorse active screening for intimate partner violence in orthopaedic fracture clinics.
- 3 July 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (13) , e91
Patient Opinions of Screening for Intimate Partner Violence in a Fracture Clinic Setting
Background: Approximately one-third of injured women presenting to fracture clinics have experienced some form of intimate partner violence in the past year. The aim of the current study was to determine patients’ perceptions on screening for intimate partner violence during visits to a surgical fracture clinic. Methods: We conducted a cross-sectional study to evaluate patients’ perceptions and opinions on screening for intimate partner violence in an orthopaedic fracture clinic. Eligible patients anonymously completed a self-reported written questionnaire, which included questions on patient demographics, attitudes toward intimate partner violence in general, the acceptability of screening for intimate partner violence in an orthopaedic fracture clinic, and opinions on how, when, and by whom the screening should be conducted. Results: The study included 750 patients (421 male and 329 female) at five clinical sites in Canada and the Netherlands. The majority (554, 73.9%) of the respondents either “agreed” or “strongly agreed” that the fracture clinic was a good place for health-care providers to ask about intimate partner violence. The majority (671, 89.5%) also agreed that health-care providers should screen for intimate partner violence by means of face-to-face interactions rather than other, more passive methods. Increased openness to screening was significantly associated with female sex, higher income, and higher education (F3595 = 21.950, p < 0.001). Conclusions: Our findings demonstrated that the majority of patients endorse active screening for intimate partner violence in orthopaedic fracture clinics.
- 1 November 2011
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 25 (11) , 674-680
Pathophysiology of Fat Embolism: A Rabbit Model
Objectives: The objective of this study was to assess the effects of fat embolism on rabbit physiology. Methods: After anesthetic administration, both femoral condyles of the right knee only of 23 New Zealand white rabbits were exposed through a medial parapatellar approach to the knee. In the pulmonary fat embolism group (n = 15), the femoral canal was drilled in a retrograde fashion and then reamed and pressurized with a 1- to 1.5-mL cement injection. In the no-pressurization group (n = 4), after reaming, no cement was injected. In the control group (n = 4), the knee incision was immediately closed. Animals were then observed for 5 hours. Hemodynamics and blood gases were recorded at standard intervals. Postmortem, the lungs were removed en bloc and fixed for histologic assessment and quantitative histomorphometry. Results: Four intraoperative deaths occurred in the pulmonary fat embolism group immediately after pressurization and may have been associated with hypotension and cardiac arrest. In the pulmonary fat embolism group, pulmonary artery pressure increased, and both mean arterial pressure and PaO2 decreased after pressurization. Approximately 2% of lung volume was occupied by intravascular fat and there were no signs of perivascular inflammation. Control and no-pressurization animals remained stable throughout the experiment. Conclusions: This model simulates pulmonary fat embolism after long-bone fractures. Despite cardiorespiratory dysfunction, there was no evidence of fat initiating pulmonary inflammation based on histologic data within the timeframe of the investigation.
- 1 November 2011
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 25 (11) , 674-680
Pathophysiology of Fat Embolism: A Rabbit Model
Objectives: The objective of this study was to assess the effects of fat embolism on rabbit physiology. Methods: After anesthetic administration, both femoral condyles of the right knee only of 23 New Zealand white rabbits were exposed through a medial parapatellar approach to the knee. In the pulmonary fat embolism group (n = 15), the femoral canal was drilled in a retrograde fashion and then reamed and pressurized with a 1- to 1.5-mL cement injection. In the no-pressurization group (n = 4), after reaming, no cement was injected. In the control group (n = 4), the knee incision was immediately closed. Animals were then observed for 5 hours. Hemodynamics and blood gases were recorded at standard intervals. Postmortem, the lungs were removed en bloc and fixed for histologic assessment and quantitative histomorphometry. Results: Four intraoperative deaths occurred in the pulmonary fat embolism group immediately after pressurization and may have been associated with hypotension and cardiac arrest. In the pulmonary fat embolism group, pulmonary artery pressure increased, and both mean arterial pressure and PaO2 decreased after pressurization. Approximately 2% of lung volume was occupied by intravascular fat and there were no signs of perivascular inflammation. Control and no-pressurization animals remained stable throughout the experiment. Conclusions: This model simulates pulmonary fat embolism after long-bone fractures. Despite cardiorespiratory dysfunction, there was no evidence of fat initiating pulmonary inflammation based on histologic data within the timeframe of the investigation.
- Open Access
- 12 May 2010
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 5 (1) , 34
A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements
Background: The bone loss associated with revision surgery or pathology has been the impetus for developing modular revision total hip prostheses. Few studies have assessed these modular implants quantitatively from a mechanical standpoint. Methods: Three-dimensional finite element (FE) models were developed to mimic a hip implant alone (Construct A) and a hip implant-femur configuration (Construct B). Bonded contact was assumed for all interfaces to simulate long-term bony ongrowth and stability. The hip implants modeled were a Modular stem having two interlocking parts (Zimmer Modular Revision Hip System, Zimmer, Warsaw, IN, USA) and a Monoblock stem made from a single piece of material (Stryker Restoration HA Hip System, Stryker, Mahwah, NJ, USA). Axial loads of 700 and 2000 N were applied to Construct A and 2000 N to Construct B models. Stiffness, strain, and stress were computed. Mechanical tests using axial loads were used for Construct A to validate the FE model. Strain gages were placed along the medial and lateral side of the hip implants at 8 locations to measure axial strain distribution. Results: There was approximately a 3% average difference between FE and experimental strains for Construct A at all locations for the Modular implant and in the proximal region for the Monoblock implant. FE results for Construct B showed that both implants carried the majority (Modular, 76%; Monoblock, 66%) of the 2000 N load relative to the femur. FE analysis and experiments demonstrated that the Modular implant was 3 to 4.5 times mechanically stiffer than the Monoblock due primarily to geometric differences. Conclusions: This study provides mechanical characteristics of revision hip implants at sub-clinical axial loads as an initial predictor of potential failure.
- 12 May 2010
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 5 (1) , 34
Open AccessA biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements
Background: The bone loss associated with revision surgery or pathology has been the impetus for developing modular revision total hip prostheses. Few studies have assessed these modular implants quantitatively from a mechanical standpoint. Methods: Three-dimensional finite element (FE) models were developed to mimic a hip implant alone (Construct A) and a hip implant-femur configuration (Construct B). Bonded contact was assumed for all interfaces to simulate long-term bony ongrowth and stability. The hip implants modeled were a Modular stem having two interlocking parts (Zimmer Modular Revision Hip System, Zimmer, Warsaw, IN, USA) and a Monoblock stem made from a single piece of material (Stryker Restoration HA Hip System, Stryker, Mahwah, NJ, USA). Axial loads of 700 and 2000 N were applied to Construct A and 2000 N to Construct B models. Stiffness, strain, and stress were computed. Mechanical tests using axial loads were used for Construct A to validate the FE model. Strain gages were placed along the medial and lateral side of the hip implants at 8 locations to measure axial strain distribution. Results: There was approximately a 3% average difference between FE and experimental strains for Construct A at all locations for the Modular implant and in the proximal region for the Monoblock implant. FE results for Construct B showed that both implants carried the majority (Modular, 76%; Monoblock, 66%) of the 2000 N load relative to the femur. FE analysis and experiments demonstrated that the Modular implant was 3 to 4.5 times mechanically stiffer than the Monoblock due primarily to geometric differences. Conclusions: This study provides mechanical characteristics of revision hip implants at sub-clinical axial loads as an initial predictor of potential failure.
- Open Access
- 4 February 2010
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (8) , 1007-1014
Endothelial progenitor cells promote fracture healing in a segmental bone defect model
The objective of this study was to evaluate the effects of local endothelial progenitor cell (EPC) therapy on bone regeneration in a rat model. A segmental bone defect (5 mm) was created in the femur and fixed with a mini‐plate. There were two groups: EPC‐treated (N = 28) and control (N = 28). Seven animals were sacrificed from each group at 1, 2, 3, and 10 weeks postoperatively. Healing of the defect was evaluated with radiographic, histological, and quantitative micro‐computed tomography (micro‐CT) scans. Radiographically, mean scores of the EPC and control groups were, respectively, 1.16–0.61 (p < 0.05) at 1 week, 2.53–1.54 (p < 0.05) at 2 weeks, and 4.58–2.35 at 3 weeks (p < 0.05). At 10 weeks, all the animals in the EPC‐treated group had complete union (7/7), but in the control group none achieved union (0/7). Histological evaluation revealed that specimens from EPC‐treated animals had abundant new bone and vessel formation compared to that in controls. Micro‐CT assessment of the samples from the animals sacrificed at 10 weeks (N = 14) showed significantly improved parameters of bone volume (36.58–10.57, p = 0.000), bone volume density (0.26–0.17, p = 0.000), model index −2.22–2.79, p = 0.000), trabecular number (1.28–0.91, p = 0.063), trabecular thickness (0.21–0.15, p = 0.001), trabecular spacing (0.63–1.07, p = 0.022), bone surface (353.75–152.08, p = 0.000), and bone surface to bone volume ratio (9.54–14.24, p = 0.004) for the EPC group compared to control, respectively. In conclusion, local EPC therapy significantly enhanced bone regeneration in a segmental defect model in rat femur diaphysis. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1007–1014, 2010
- 4 February 2010
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (8) , 1007-1014
Open AccessEndothelial progenitor cells promote fracture healing in a segmental bone defect model
The objective of this study was to evaluate the effects of local endothelial progenitor cell (EPC) therapy on bone regeneration in a rat model. A segmental bone defect (5 mm) was created in the femur and fixed with a mini‐plate. There were two groups: EPC‐treated (N = 28) and control (N = 28). Seven animals were sacrificed from each group at 1, 2, 3, and 10 weeks postoperatively. Healing of the defect was evaluated with radiographic, histological, and quantitative micro‐computed tomography (micro‐CT) scans. Radiographically, mean scores of the EPC and control groups were, respectively, 1.16–0.61 (p < 0.05) at 1 week, 2.53–1.54 (p < 0.05) at 2 weeks, and 4.58–2.35 at 3 weeks (p < 0.05). At 10 weeks, all the animals in the EPC‐treated group had complete union (7/7), but in the control group none achieved union (0/7). Histological evaluation revealed that specimens from EPC‐treated animals had abundant new bone and vessel formation compared to that in controls. Micro‐CT assessment of the samples from the animals sacrificed at 10 weeks (N = 14) showed significantly improved parameters of bone volume (36.58–10.57, p = 0.000), bone volume density (0.26–0.17, p = 0.000), model index −2.22–2.79, p = 0.000), trabecular number (1.28–0.91, p = 0.063), trabecular thickness (0.21–0.15, p = 0.001), trabecular spacing (0.63–1.07, p = 0.022), bone surface (353.75–152.08, p = 0.000), and bone surface to bone volume ratio (9.54–14.24, p = 0.004) for the EPC group compared to control, respectively. In conclusion, local EPC therapy significantly enhanced bone regeneration in a segmental defect model in rat femur diaphysis. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1007–1014, 2010
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (5) , 1264-1273
Orthopaedic Surgeons: Artists or Scientists?*
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (5) , 1264-1273
Orthopaedic Surgeons: Artists or Scientists?*
- Open Access
- 1 January 2009
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 43 (2) , 127-31
The science of electrical stimulation therapy for fracture healing
This article is a brief review of the basic science research conducted in the field of electrical stimulation for fracture healing. Direct electrical current, capacitive coupling, and inductive coupling have been studied as potential techniques to enhance fracture healing through the proliferation and differentiation of osteogenic cells. These techniques are particularly appealing as they offer a potential minimally invasive solution to the difficult clinical problem of delayed fracture healing and nonunion. Basic science studies have shown conclusively that electrical stimulation techniques lead to bone cell proliferation and have attempted to elucidate the intracellular processes by which this bone cell proliferation occurs. Further basic science and clinical research is required to enhance the effectiveness of this therapy for the treatment of fracture nonunions.
- 1 January 2009
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 43 (2) , 127-31
Open AccessThe science of electrical stimulation therapy for fracture healing
This article is a brief review of the basic science research conducted in the field of electrical stimulation for fracture healing. Direct electrical current, capacitive coupling, and inductive coupling have been studied as potential techniques to enhance fracture healing through the proliferation and differentiation of osteogenic cells. These techniques are particularly appealing as they offer a potential minimally invasive solution to the difficult clinical problem of delayed fracture healing and nonunion. Basic science studies have shown conclusively that electrical stimulation techniques lead to bone cell proliferation and have attempted to elucidate the intracellular processes by which this bone cell proliferation occurs. Further basic science and clinical research is required to enhance the effectiveness of this therapy for the treatment of fracture nonunions.
- Open Access
- 16 July 2008
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 27 (1) , 8-14
Effect of cell‐based VEGF gene therapy on healing of a segmental bone defect
Fracture healing requires coordinated coupling between osteogenesis and angiogenesis in which vascular endothelial growth factor (VEGF) plays a key role. We hypothesized that targeted over‐expression of angiogenic and osteogenic factors within the fracture would promote bone healing by inducing development of new blood vessels and stimulating/affecting proliferation, survival, and activity of skeletal cells. Using a cell‐based method of gene transfer, without viral vector, 5.0 × 106 fibroblasts transfected with VEGF were delivered to a 10‐mm bone defect in rabbit tibiae (Group 1) (n = 9); control groups were treated with fibroblasts (Group 2) (n = 7), or saline (Group 3) (n = 7) only. After 12 weeks, eight tibial fractures healed in Group 1, compared to four each in Groups 2 and 3. In Group 1, ossification was seen across the entire defect; in Groups 2 and 3, the defects were fibrous and sparsely ossified. Group 1 had more positively stained (CD31) vessels than Groups 2 and 3. MicroCT 3‐D showed complete bridging of the new bone for Group 1, but incomplete healing for Groups 2 and 3. MicroCT bone structural parameters showed significant differences between VEGF treatment and control groups (p < 0.05). These results indicate that the cell‐based VEGF gene therapy has significant angiogenic and osteogenic effects to enhance healing of a segmental defect in the long bone of rabbits. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:8–14, 2009
- 16 July 2008
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 27 (1) , 8-14
Open AccessEffect of cell‐based VEGF gene therapy on healing of a segmental bone defect
Fracture healing requires coordinated coupling between osteogenesis and angiogenesis in which vascular endothelial growth factor (VEGF) plays a key role. We hypothesized that targeted over‐expression of angiogenic and osteogenic factors within the fracture would promote bone healing by inducing development of new blood vessels and stimulating/affecting proliferation, survival, and activity of skeletal cells. Using a cell‐based method of gene transfer, without viral vector, 5.0 × 106 fibroblasts transfected with VEGF were delivered to a 10‐mm bone defect in rabbit tibiae (Group 1) (n = 9); control groups were treated with fibroblasts (Group 2) (n = 7), or saline (Group 3) (n = 7) only. After 12 weeks, eight tibial fractures healed in Group 1, compared to four each in Groups 2 and 3. In Group 1, ossification was seen across the entire defect; in Groups 2 and 3, the defects were fibrous and sparsely ossified. Group 1 had more positively stained (CD31) vessels than Groups 2 and 3. MicroCT 3‐D showed complete bridging of the new bone for Group 1, but incomplete healing for Groups 2 and 3. MicroCT bone structural parameters showed significant differences between VEGF treatment and control groups (p < 0.05). These results indicate that the cell‐based VEGF gene therapy has significant angiogenic and osteogenic effects to enhance healing of a segmental defect in the long bone of rabbits. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:8–14, 2009
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (5) , 1068-1077
Biomechanical Evaluation of Periprosthetic Femoral Fracture Fixation
Background: A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Methods: Twenty synthetic femora were tested in axial compression, lateral bending, and torsion to determine initial stiffness, as well as stiffness following fixation of a simulated femoral midshaft fracture with and without a bone gap. Four fracture fixation constructs (five specimens per group) were assessed: construct A was a Synthes locked plate (a twelve-hole broad dynamic compression plate) with locked screws; construct B, a Synthes locked plate (a twelve-hole broad dynamic compression plate) with cables and locked screws; construct C, a Zimmer nonlocking (eight-hole) cable plate with cables and nonlocked screws; and construct D, a Zimmer nonlocking (eight-hole) cable plate with allograft strut, cables, and nonlocked screws. Axial stiffness, lateral bending stiffness, and torsional stiffness were assessed with respect to baseline intact specimen values. Axial load to failure was also measured for the specimens. Results: Construct D demonstrated either equivalent or superior stiffness in all testing modes compared with the other constructs in femora with both a midshaft fracture and a bone gap. A comparison of constructs A, B, and C demonstrated equivalent stiffness in all test modes (with one exception) in femora with a midshaft fracture and a bone gap. Conclusions: A combination of a nonlocking plate with an allograft strut (construct D) resulted in the highest stiffness of the constructs examined for treating a periprosthetic fracture around a stable femoral component of a total hip replacement. Clinical Relevance: A locked plate (constructs A and B) should be used with caution as a stand-alone treatment for the fixation of a periprosthetic femoral shaft fracture following total hip arthroplasty, particularly with good bone stock.
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (5) , 1068-1077
Biomechanical Evaluation of Periprosthetic Femoral Fracture Fixation
Background: A variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Methods: Twenty synthetic femora were tested in axial compression, lateral bending, and torsion to determine initial stiffness, as well as stiffness following fixation of a simulated femoral midshaft fracture with and without a bone gap. Four fracture fixation constructs (five specimens per group) were assessed: construct A was a Synthes locked plate (a twelve-hole broad dynamic compression plate) with locked screws; construct B, a Synthes locked plate (a twelve-hole broad dynamic compression plate) with cables and locked screws; construct C, a Zimmer nonlocking (eight-hole) cable plate with cables and nonlocked screws; and construct D, a Zimmer nonlocking (eight-hole) cable plate with allograft strut, cables, and nonlocked screws. Axial stiffness, lateral bending stiffness, and torsional stiffness were assessed with respect to baseline intact specimen values. Axial load to failure was also measured for the specimens. Results: Construct D demonstrated either equivalent or superior stiffness in all testing modes compared with the other constructs in femora with both a midshaft fracture and a bone gap. A comparison of constructs A, B, and C demonstrated equivalent stiffness in all test modes (with one exception) in femora with a midshaft fracture and a bone gap. Conclusions: A combination of a nonlocking plate with an allograft strut (construct D) resulted in the highest stiffness of the constructs examined for treating a periprosthetic fracture around a stable femoral component of a total hip replacement. Clinical Relevance: A locked plate (constructs A and B) should be used with caution as a stand-alone treatment for the fixation of a periprosthetic femoral shaft fracture following total hip arthroplasty, particularly with good bone stock.
- 1 April 2008
- Published by Elsevier in Operative Techniques in Orthopaedics
- Vol. 18 (2) , 114-120
Surgical Techniques for the Management of Proximal Femoral Fracture Nonunions
- 1 April 2008
- Published by Elsevier in Operative Techniques in Orthopaedics
- Vol. 18 (2) , 114-120
Surgical Techniques for the Management of Proximal Femoral Fracture Nonunions