Michael Bader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Bader has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Renate Wrbitzky
Department of Occupational Medicine, Hannover Medical School, Hannover, Germany
6 shared publicationsStephen A. Keener
Department of Occupational Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
3 shared publications- Christoph van Thriel
Leibniz Research Center for Working Environment and Human Factors, Department of Toxicology, Dortmund, 44139, Germany
2 shared publications Meinolf Blaszkewicz
Institute for Occupational Physiology at the University of Dortmund (IfADo), Dortmund, Germany
2 shared publicationsWolfgang Rosenberger
Institute for Occupational Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
2 shared publicationsDimitrios Tsikas
Institute for Clinical Pharmacology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
1 shared publication
Latest Publications
- 25 August 2007
- Published by Springer Nature in Archives of Toxicology
- Vol. 82 (1) , 13-20
Human volunteer study on the inhalational and dermal absorption of N-methyl-2-pyrrolidone (NMP) from the vapour phase
N-Methyl-2-pyrrolidone (NMP) is a versatile organic solvent frequently used for surface cleaning such as paint stripping or graffiti removal. Liquid NMP is rapidly absorbed through the skin but dermal vapour phase absorption might also play an important role for the uptake of the solvent. This particular aspect was investigated in an experimental study with 16 volunteers exposed to 80 mg/m3 NMP for 8 h under either whole-body, i.e. inhalational plus dermal, or dermal-only conditions. Additionally, the influence of moderate physical workload on the uptake of NMP was studied. The urinary concentrations of NMP and its metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) were followed for 48 h and analysed by gas chromatography–mass spectrometry (GC–MS). Percutaneous uptake delayed the elimination peak times and the apparent biological half-lives of NMP and 5-HNMP. Under resting conditions, dermal-only exposure resulted in the elimination of 71 ± 8 mg NMP equivalents as compared to 169 ± 15 mg for whole-body exposure. Moderate workload yielded 79 ± 8 mg NMP (dermal-only) and 238 ± 18 mg (whole-body). Thus, dermal absorption from the vapour phase may contribute significantly to the total uptake of NMP, e.g. from workplace atmospheres. As the concentration of airborne NMP does not reflect the body dose, biomonitoring should be carried out for surveillance purposes.
- 25 August 2007
- Published by Springer Nature in Archives of Toxicology
- Vol. 82 (1) , 13-20
Human volunteer study on the inhalational and dermal absorption of N-methyl-2-pyrrolidone (NMP) from the vapour phase
N-Methyl-2-pyrrolidone (NMP) is a versatile organic solvent frequently used for surface cleaning such as paint stripping or graffiti removal. Liquid NMP is rapidly absorbed through the skin but dermal vapour phase absorption might also play an important role for the uptake of the solvent. This particular aspect was investigated in an experimental study with 16 volunteers exposed to 80 mg/m3 NMP for 8 h under either whole-body, i.e. inhalational plus dermal, or dermal-only conditions. Additionally, the influence of moderate physical workload on the uptake of NMP was studied. The urinary concentrations of NMP and its metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) were followed for 48 h and analysed by gas chromatography–mass spectrometry (GC–MS). Percutaneous uptake delayed the elimination peak times and the apparent biological half-lives of NMP and 5-HNMP. Under resting conditions, dermal-only exposure resulted in the elimination of 71 ± 8 mg NMP equivalents as compared to 169 ± 15 mg for whole-body exposure. Moderate workload yielded 79 ± 8 mg NMP (dermal-only) and 238 ± 18 mg (whole-body). Thus, dermal absorption from the vapour phase may contribute significantly to the total uptake of NMP, e.g. from workplace atmospheres. As the concentration of airborne NMP does not reflect the body dose, biomonitoring should be carried out for surveillance purposes.
- 14 November 2006
- Published by Springer Nature in Archives of Toxicology
- Vol. 81 (5) , 335-346
Human experimental exposure study on the uptake and urinary elimination of N-methyl-2-pyrrolidone (NMP) during simulated workplace conditions
A human experimental study was carried out with 16 volunteers to examine the elimination of N-methyl-2-pyrrolidone (NMP) after exposure to the solvent under simulated workplace conditions. The NMP concentrations were 10, 40 and 80 mg/m3 for 2 × 4 h with an exposure-free interval of 30 min. Additionally, a peak exposure scenario (25 mg/m3 baseline, 160 mg/m3 peaks for 4 × 15 min, time-weighted average: 72 mg/m3) was tested. The influence of physical activity on the uptake and elimination of NMP was studied under otherwise identical exposure conditions but involving moderate workload on a bicycle ergometer (75 W for 6 × 10 min). The peak times and biological half-lives of urinary NMP and its main metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) in urine were analysed as well as the interrelationships between exposure and biomarkers. All analytes showed a close correlation between their post-shift peak concentrations and airborne NMP. An exposure to the current German workplace limit value of 80 mg/m3 under resting conditions resulted in urinary peak concentrations of 2,400 μg/L NMP, 117 mg/g creatinine 5-HNMP and 32 mg/g creatinine 2-HMSI (workload conditions: 3,400 μg/L NMP, 150 mg/g creatinine 5-HNMP, 44 mg/g creatinine 2-HMSI). Moderate workload enhanced the total uptake of NMP by approximately one third. Differences between the estimated and the observed total amount of urinary metabolites point to a significant contribution of dermal absorption on the uptake of NMP. This aspect, together with the influence of physical workload, should be considered for the evaluation of a biological limit value for NMP.
- 14 November 2006
- Published by Springer Nature in Archives of Toxicology
- Vol. 81 (5) , 335-346
Human experimental exposure study on the uptake and urinary elimination of N-methyl-2-pyrrolidone (NMP) during simulated workplace conditions
A human experimental study was carried out with 16 volunteers to examine the elimination of N-methyl-2-pyrrolidone (NMP) after exposure to the solvent under simulated workplace conditions. The NMP concentrations were 10, 40 and 80 mg/m3 for 2 × 4 h with an exposure-free interval of 30 min. Additionally, a peak exposure scenario (25 mg/m3 baseline, 160 mg/m3 peaks for 4 × 15 min, time-weighted average: 72 mg/m3) was tested. The influence of physical activity on the uptake and elimination of NMP was studied under otherwise identical exposure conditions but involving moderate workload on a bicycle ergometer (75 W for 6 × 10 min). The peak times and biological half-lives of urinary NMP and its main metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) in urine were analysed as well as the interrelationships between exposure and biomarkers. All analytes showed a close correlation between their post-shift peak concentrations and airborne NMP. An exposure to the current German workplace limit value of 80 mg/m3 under resting conditions resulted in urinary peak concentrations of 2,400 μg/L NMP, 117 mg/g creatinine 5-HNMP and 32 mg/g creatinine 2-HMSI (workload conditions: 3,400 μg/L NMP, 150 mg/g creatinine 5-HNMP, 44 mg/g creatinine 2-HMSI). Moderate workload enhanced the total uptake of NMP by approximately one third. Differences between the estimated and the observed total amount of urinary metabolites point to a significant contribution of dermal absorption on the uptake of NMP. This aspect, together with the influence of physical workload, should be considered for the evaluation of a biological limit value for NMP.
- 9 August 2006
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 80 (4) , 327-334
Human volunteer study on the influence of exposure duration and dilution of dermally applied N-methyl-2-pyrrolidone (NMP) on the urinary elimination of NMP metabolites
Objectives N-Methyl-2-pyrrolidone (NMP) is a versatile solvent used in various industrial processes and applications. Apart from its mildly irritating effects on the eyes, the mucous membranes and the skin, NMP has revealed prenatal toxicity in animal experiments after the oral administration of high doses. The dermal absorption of NMP and the urinary elimination of its main metabolites were investigated within an experimental exposure study. Methods Four male volunteers were exposed to liquid NMP under occlusive conditions on the back of one hand with varying exposure times and solvent concentrations. Urine was collected before, during and after the exposure and analysed for the main NMP metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI). Results The urinary concentration of the metabolites upon exposure to undiluted NMP for 2 h increased rapidly with 5-HNMP reaching a maximum at 4–5 h and 2-HMSI after 26–29 h. The application of aqueous NMP solutions resulted in a delay of the peak time for 5-HNMP of approximately 6 h as compared with the undiluted solvent. An average dermal absorption of 5.4±1.5 mg NMP cm−2 h−1 was calculated for a 2 h exposure to undiluted NMP (6.5±2.0 mg NMP cm−2 h−1 for a 30 min exposure). Aqueous dilution of NMP to 50% was followed by a decrease of the absorption to 0.9±0.5 mg NMP cm−2 h−1. NMP metabolite concentrations in the range of the detection limits were found only in isolated urine samples after exposure to 10% NMP in aqueous dilution. Conclusions NMP is rapidly absorbed across the skin and the dermal route may contribute significantly to the uptake of the solvent. Therefore, a biomonitoring of NMP exposed workers is essential for occupational-medical surveillance. Both urinary metabolites reflect the internal dose after a dermal absorption of NMP and thus qualify as suitable biomarkers for NMP exposure.
- 9 August 2006
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 80 (4) , 327-334
Human volunteer study on the influence of exposure duration and dilution of dermally applied N-methyl-2-pyrrolidone (NMP) on the urinary elimination of NMP metabolites
Objectives N-Methyl-2-pyrrolidone (NMP) is a versatile solvent used in various industrial processes and applications. Apart from its mildly irritating effects on the eyes, the mucous membranes and the skin, NMP has revealed prenatal toxicity in animal experiments after the oral administration of high doses. The dermal absorption of NMP and the urinary elimination of its main metabolites were investigated within an experimental exposure study. Methods Four male volunteers were exposed to liquid NMP under occlusive conditions on the back of one hand with varying exposure times and solvent concentrations. Urine was collected before, during and after the exposure and analysed for the main NMP metabolites 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI). Results The urinary concentration of the metabolites upon exposure to undiluted NMP for 2 h increased rapidly with 5-HNMP reaching a maximum at 4–5 h and 2-HMSI after 26–29 h. The application of aqueous NMP solutions resulted in a delay of the peak time for 5-HNMP of approximately 6 h as compared with the undiluted solvent. An average dermal absorption of 5.4±1.5 mg NMP cm−2 h−1 was calculated for a 2 h exposure to undiluted NMP (6.5±2.0 mg NMP cm−2 h−1 for a 30 min exposure). Aqueous dilution of NMP to 50% was followed by a decrease of the absorption to 0.9±0.5 mg NMP cm−2 h−1. NMP metabolite concentrations in the range of the detection limits were found only in isolated urine samples after exposure to 10% NMP in aqueous dilution. Conclusions NMP is rapidly absorbed across the skin and the dermal route may contribute significantly to the uptake of the solvent. Therefore, a biomonitoring of NMP exposed workers is essential for occupational-medical surveillance. Both urinary metabolites reflect the internal dose after a dermal absorption of NMP and thus qualify as suitable biomarkers for NMP exposure.
- 10 April 2006
- Published by Elsevier in Toxicology Letters
- Vol. 162 (2-3) , 125-131
Follow-up biomonitoring after accidental exposure to acrylonitrile—Implications for protein adducts as a dose monitor for short-term exposures
- 10 April 2006
- Published by Elsevier in Toxicology Letters
- Vol. 162 (2-3) , 125-131
Follow-up biomonitoring after accidental exposure to acrylonitrile—Implications for protein adducts as a dose monitor for short-term exposures
- 15 December 2005
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 79 (5) , 357-364
Ambient monitoring and biomonitoring of workers exposed to N-methyl-2-pyrrolidone in an industrial facility
Objectives: The exposure of seven workers and three on-site study examiners to N-methyl-2-pyrrolidone (NMP) was studied in an adhesive bonding compound and glue production facility. Methods: Airborne NMP was analysed by personal and stationary sampling on activated charcoal tubes. NMP and its main metabolites, 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI), were analysed in pre-shift and post-shift spot urine samples by gas chromatography-mass spectrometry. The workers were examined with respect to irritation of the eyes, the mucous membranes and the skin, and health complaints before and after the work-shift were recorded. Results: The time-weighted average concentration of NMP in most work areas varied between 0.2 and 3.0 mg/m3. During the manual cleaning of stirring vessels, valves and tools, 8-h TWA exposures of up to 15.5 mg/m3 and single peak exposures of up to 85 mg/m3 were observed. NMP and its metabolites were detected in two pre-shift urine specimens. NMP and 5-HNMP concentrations in post-shift urine samples of five workers and three on-site study examiners were below 125 μg/g creatinine and 15 mg/g creatinine, respectively, while two vessel-cleaning workers showed significantly higher urinary NMP concentrations of 472 and 711 μg/g creatinine and 5-HNMP concentrations of 33.5 and 124 mg/g creatinine. 2-HMSI was detectable in four post-shift samples (range: 1.6–14.7 mg/g creatinine). The vessel cleaner with the highest NMP exposure reported irritation of the eyes, the upper respiratory tract and headaches. Conclusions: The results of this study indicate a relatively low overall exposure to NMP in the facility. An increased uptake of NMP occurred only during extensive manual vessel cleaning. Health complaints associated with NMP exposure were recorded in one case and might be related to an excessive dermal exposure due to infrequent and inadequate use of personal protective equipment.
- 15 December 2005
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 79 (5) , 357-364
Ambient monitoring and biomonitoring of workers exposed to N-methyl-2-pyrrolidone in an industrial facility
Objectives: The exposure of seven workers and three on-site study examiners to N-methyl-2-pyrrolidone (NMP) was studied in an adhesive bonding compound and glue production facility. Methods: Airborne NMP was analysed by personal and stationary sampling on activated charcoal tubes. NMP and its main metabolites, 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI), were analysed in pre-shift and post-shift spot urine samples by gas chromatography-mass spectrometry. The workers were examined with respect to irritation of the eyes, the mucous membranes and the skin, and health complaints before and after the work-shift were recorded. Results: The time-weighted average concentration of NMP in most work areas varied between 0.2 and 3.0 mg/m3. During the manual cleaning of stirring vessels, valves and tools, 8-h TWA exposures of up to 15.5 mg/m3 and single peak exposures of up to 85 mg/m3 were observed. NMP and its metabolites were detected in two pre-shift urine specimens. NMP and 5-HNMP concentrations in post-shift urine samples of five workers and three on-site study examiners were below 125 μg/g creatinine and 15 mg/g creatinine, respectively, while two vessel-cleaning workers showed significantly higher urinary NMP concentrations of 472 and 711 μg/g creatinine and 5-HNMP concentrations of 33.5 and 124 mg/g creatinine. 2-HMSI was detectable in four post-shift samples (range: 1.6–14.7 mg/g creatinine). The vessel cleaner with the highest NMP exposure reported irritation of the eyes, the upper respiratory tract and headaches. Conclusions: The results of this study indicate a relatively low overall exposure to NMP in the facility. An increased uptake of NMP occurred only during extensive manual vessel cleaning. Health complaints associated with NMP exposure were recorded in one case and might be related to an excessive dermal exposure due to infrequent and inadequate use of personal protective equipment.
- 5 July 2005
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 78 (8) , 673-676
Dermal absorption and urinary elimination of N-methyl-2-pyrrolidone
- 5 July 2005
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 78 (8) , 673-676
Dermal absorption and urinary elimination of N-methyl-2-pyrrolidone
- 5 August 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 380 (1) , 59-67
Interlaboratory comparison to evaluate a standardized calibration procedure for the headspace analysis of aromatic solvents in blood
The determination of volatile organic compounds in blood by headspace gas chromatography is one of the central and long-established analytical techniques in occupational medical biomonitoring. Nevertheless, the relatively low success rate in intercomparison programs shows that the headspace technique is insufficiently standardized. A critical stage of the analytical procedure seems to be the preparation of calibration standards in biological matrices. As part of an extensive interlaboratory comparison by the Analyses of Hazardous Substances in Biological Materials working group of the DFG Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area, three typical procedures were compared with one another using typical aromatic solvents as an example. The best correlations between the participating laboratories and the best results for the analyses of samples from interlaboratory comparisons were obtained when highly concentrated stock solutions of the aromatic compounds in ethanol were first diluted with physiological saline and then used for spiking horse blood in headspace vials. This procedure can be easily standardized and is therefore recommended by the Analyses of Hazardous Substances in Biological Materials working group for the preparation of headspace calibration standards for aromatic compounds.
- 5 August 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 380 (1) , 59-67
Interlaboratory comparison to evaluate a standardized calibration procedure for the headspace analysis of aromatic solvents in blood
The determination of volatile organic compounds in blood by headspace gas chromatography is one of the central and long-established analytical techniques in occupational medical biomonitoring. Nevertheless, the relatively low success rate in intercomparison programs shows that the headspace technique is insufficiently standardized. A critical stage of the analytical procedure seems to be the preparation of calibration standards in biological matrices. As part of an extensive interlaboratory comparison by the Analyses of Hazardous Substances in Biological Materials working group of the DFG Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area, three typical procedures were compared with one another using typical aromatic solvents as an example. The best correlations between the participating laboratories and the best results for the analyses of samples from interlaboratory comparisons were obtained when highly concentrated stock solutions of the aromatic compounds in ethanol were first diluted with physiological saline and then used for spiking horse blood in headspace vials. This procedure can be easily standardized and is therefore recommended by the Analyses of Hazardous Substances in Biological Materials working group for the preparation of headspace calibration standards for aromatic compounds.