ZKZoltan J. Koles

Zoltan J. Koles

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zoltan J. Koles has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gender Differences in Brain Functional Organization During Verbal and Spatial Cognitive Challenges

    by Zoltan J. Koles, John C. Lind, Pierre Flor-Henry

    This is a quantitative EEG study of gender-related differences in brain function. It is novel in that to elicit gender differences, it was necessary to apply a spatial filter to the EEGs that was effective for suppressing components common to different cognitive states. The study involved estimates of both the source-current power density in the brain and the complex coherence between different regions in the brain, the latter probably unique in EEG source analysis. Gender effects are shown in terms of differences in both lateralized source power and complex coherence in response to verbal and spatial cognitive challenges. The results provide evidence that verbal and spatial challenges are more lateralized in males than in females, that females are more verbal than males, that males are more spatial than females, that females verbalize more interpretively than males and that males verbalize more consequentially than females.


  • Head Modeling for E/MEG Source Analysis: Image Segmentation, Domain Decomposition and Solution of the Forward Problem

    by Zoltan J. Koles

    Issues in head modeling for E/MEG source analysis are discussed and some of the methods developed by our group are outlined. For image segmentation, a Kalman filter based edge tracing algorithm is described that performs well on noisy images and where intensity nonuniformity and partial volume effects are factors. For domain decomposition, a high resolution finite volume method is described that simplifies grid generation, meshing and source modeling. For the solution of the forward problem, a polynomial preconditioned conjugate gradient method is described that is efficient in terms of both computational speed and memory utilization.

  • Medical Image Segmentation: Methods and Software

    by D.J. Withey, Z.J. Koles

    Methods for segmentation of medical images are divided into three generations, where each generation adds an additional level of algorithmic complexity. The first generation is composed of the simplest forms of image analysis such as the use of intensity thresholds and region growing. The second generation is characterized by the application of uncertainty models and optimization methods, and the third generation incorporates knowledge into the segmentation process. Sources of segmentation software from industry and academia are identified along with databases for segmentation validation.


  • Comparison of Hemodynamic Response Models in a Combined EEG-fMRI Study of an Epileptic Patient

    by Todd J.M. Penney, Bradley Goodyear, Daniel Pittman, Paolo Federico, Zoltan J. Koles

    Independent component analysis (ICA) and statistical parametric mapping (SPM) are two commonly used methods of analyzing fMRI measurements taken from a patient's brain. Typically, these methods are applied separately to the measurements to produce brain maps indicating where the patient's brain was active while he or she performed a task or experienced a stimulus. ICA can also be used to develop a hemodynamic response model that can be used as a regressor in SPM of fMRI measurements, a statistical analysis procedure that uses the general linear model (GLM). This may lead to a more accurate method of localizing patient brain activity because the hemodynamic response model is tailored to the patient's own measurements. In this study, BOLD fMRI data and EEG data were acquired from a continuous EEG-fMRI study done on a patient suffering from refractory right temporal lobe epilepsy. Spatial ICA was performed on the subject's BOLD fMRI measurements. One hemodynamic response model signal derived from the spatial ICA (sICA) results was generated to use as a regressor in SPM of the subject data. SPM-generated brain maps of the subject data using the canonical hemodynamic response model and the sICA-derived model were compared.

  • Evaluating the Accuracy of an Anisotropic Finite-Volume Head Model for the EEG Forward Problem

    by Michael J. D. Cook, Zoltan J. Koles

    Realistic head models are required to accurately solve the electroencephalogram (EEG) forward problem. We have developed a finite volume method (FVM) head model for this purpose. It uses a high-resolution millimeter-level cubic grid, incorporates anisotropic conductivities, and is both physically intuitive and simple to implement. In this work we use an analytic spherical head model to evaluate the performance of our FVM formulation. Two different error measures related to the magnitude and shape of the scalp potentials are used to compare the numerical and analytic head models. We determine that our FVM head model agrees with the analytic head model and calculates the shape of the scalp potentials more accurately than the magnitude. As well, our head model performs better at higher resolutions and severe anisotropy appears to be a problem at the current resolutions.

  • A Combined SPM-ICA Approach to fMRI

    by Todd J. M. Penney, Zoltan J. Koles

    Independent component analysis (ICA) and statistical parametric mapping (SPM) are two commonly used methods of analyzing fMRI measurements. Typically, these methods are applied separately to the measurements to produce brain maps indicating active brain regions in response to a stimulus or a performed task. However, ICA can also be used to develop a hemodynamic response model that can be used as a regressor in SPM of fMRI measurements. This may lead to a more accurate method of localizing brain activity that corresponds to performing a task or to various pathologies. In this study, BOLD fMRI data were acquired from a subject performing a finger flexion task in a block design paradigm. Both spatial and temporal ICA was performed on the subject's BOLD fMRI measurements. Two hemodynamic response model signals were generated from ICA results to use as regressors in SPM of the subject data. IC maps and SPM-generated brain maps of the subject data using the canonical hemodynamic response model and the ICA-derived models were compared. In all cases, there was significant overlap in voxel activations


  • A Comparison of Adaptive and Non-Adaptive EEG Source Localization Algorithms Using a Realistic Head Model

    by John P. Russell, Zoltan J. Koles

    An accurate and robust electroencephalogram (EEG) source localization algorithm would be a definite asset for the surgical treatment of patients with epilepsy. Due to the underdetermined nature of the EEG inverse problem, a variety of algorithms with unique constraints and assumptions are applied to select the current dipole source distribution that best accounts for the scalp recordings. We investigated four algorithms: two non-adaptive algorithms: the minimum norm and LORETA as well as two adaptive algorithms: the Borgiotti-Kaplan and eigenspace projection beamformers. Compared over a range of SNR values and single source locations, we found that the eigenspace projection beamformer exhibited superior localizing capabilities compared to the other three algorithms while minimizing source current dispersion. The size of the data window required to accurately localize using the adaptive beamformers was also investigated to improve algorithm efficiency and minimize stationary source assumptions


  • A High-Resolution Anisotropic Finite-Volume Head Model for EEG Source Analysis

    by Michael J. D. Cook, Zoltan J. Koles

    Solution of the electroencephalogram (EEG) forward problem in a realistic head model is necessary for accurate source analysis. Realistic head models are usually derived from volumetric magnetic resonance images that provide a voxel resolution of about 1 mm3 . The availability of an electrical head model with this resolution would therefore be extremely advantageous. Head models with resolution in the millimeter range that incorporate the anisotropic properties of their elements have been formulated with the finite element method (FEM). However, these FEM models are fraught with complications related to irregular grids and meshes, along with the incumbent segmentation problems. Presented here is a finite volume method (FVM) formulation of the realistic head model in cubic elements that can ameliorate some of these problems, can incorporate tissue anisotropy, and is both physically intuitive and simple to implement


  • A High-Resolution Anisotropic Finite-Volume Head Model for EEG Source Analysis

    by Michael J. D. Cook, Zoltan J. Koles

    Solution of the electroencephalogram (EEG) forward problem in a realistic head model is necessary for accurate source analysis. Realistic head models are usually derived from volumetric magnetic resonance images that provide a voxel resolution of about 1 mm3 . The availability of an electrical head model with this resolution would therefore be extremely advantageous. Head models with resolution in the millimeter range that incorporate the anisotropic properties of their elements have been formulated with the finite element method (FEM). However, these FEM models are fraught with complications related to irregular grids and meshes, along with the incumbent segmentation problems. Presented here is a finite volume method (FVM) formulation of the realistic head model in cubic elements that can ameliorate some of these problems, can incorporate tissue anisotropy, and is both physically intuitive and simple to implement

  • A Comparison of Adaptive and Non-Adaptive EEG Source Localization Algorithms Using a Realistic Head Model

    by John P. Russell, Zoltan J. Koles

    An accurate and robust electroencephalogram (EEG) source localization algorithm would be a definite asset for the surgical treatment of patients with epilepsy. Due to the underdetermined nature of the EEG inverse problem, a variety of algorithms with unique constraints and assumptions are applied to select the current dipole source distribution that best accounts for the scalp recordings. We investigated four algorithms: two non-adaptive algorithms: the minimum norm and LORETA as well as two adaptive algorithms: the Borgiotti-Kaplan and eigenspace projection beamformers. Compared over a range of SNR values and single source locations, we found that the eigenspace projection beamformer exhibited superior localizing capabilities compared to the other three algorithms while minimizing source current dispersion. The size of the data window required to accurately localize using the adaptive beamformers was also investigated to improve algorithm efficiency and minimize stationary source assumptions