Winfried Denk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Winfried Denk has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jeff William Lichtman
Harvard University
1 shared publication Jonas Binding
Max Planck Institute for Medical Research, Jahnstr. 29, 69120 Heidelberg, Germany
1 shared publicationMarcus Feierabend
Max Planck Institute for Medical Research, Jahnstrasse 29, D-69120 Heidelberg, Germany
1 shared publicationMarkus Rückel
Max Planck Institute for Medical Research, Jahnstrasse 29, D-69120 Heidelberg, Germany
1 shared publicationShawn Mikula
Max Planck Institute for Medical Research, Jahnstr. 29, 69120 Heidelberg, Germany
1 shared publication
Latest Publications
- 4 February 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (1) , 38-55
Low-Dosage Maximum-A-Posteriori Focusing and Stigmation
Radiation damage is often an issue during high-resolution imaging, making low-dose focusing and stigmation essential, in particular when no part of the sample can be “sacrificed” for this. An example is serial block-face electron microscopy, where the imaging resolution must be kept optimal during automated acquisition that can last months. Here, we present an algorithm, which we call “Maximum-A-Posteriori Focusing and Stigmation (MAPFoSt),” that was designed to make optimal use of the available signal. We show that MAPFoSt outperforms the built-in focusing algorithm of a commercial scanning electron microscope even at a tenfold reduced total dose. MAPFoSt estimates multiple aberration modes (focus and the two astigmatism coefficients) using just two test images taken at different focus settings. Using an incident electron dose density of 2,500 electrons/pixel and a signal-to-noise ratio of about one, all three coefficients could be estimated to within <7% of the depth of focus, using 19 detected secondary electrons per pixel. A generalization to higher-order aberrations and to other forms of imaging in both two and three dimensions appears possible.
- 4 February 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (1) , 38-55
Low-Dosage Maximum-A-Posteriori Focusing and Stigmation
Radiation damage is often an issue during high-resolution imaging, making low-dose focusing and stigmation essential, in particular when no part of the sample can be “sacrificed” for this. An example is serial block-face electron microscopy, where the imaging resolution must be kept optimal during automated acquisition that can last months. Here, we present an algorithm, which we call “Maximum-A-Posteriori Focusing and Stigmation (MAPFoSt),” that was designed to make optimal use of the available signal. We show that MAPFoSt outperforms the built-in focusing algorithm of a commercial scanning electron microscope even at a tenfold reduced total dose. MAPFoSt estimates multiple aberration modes (focus and the two astigmatism coefficients) using just two test images taken at different focus settings. Using an incident electron dose density of 2,500 electrons/pixel and a signal-to-noise ratio of about one, all three coefficients could be estimated to within <7% of the depth of focus, using 19 detected secondary electrons per pixel. A generalization to higher-order aberrations and to other forms of imaging in both two and three dimensions appears possible.
- 4 November 2011
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 334 (6056) , 618-623
The Big and the Small: Challenges of Imaging the Brain’s Circuits
The relation between the structure of the nervous system and its function is more poorly understood than the relation between structure and function in any other organ system. We explore why bridging the structure-function divide is uniquely difficult in the brain. These difficulties also explain the thrust behind the enormous amount of innovation centered on microscopy in neuroscience. We highlight some recent progress and the challenges that remain.
- 4 November 2011
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 334 (6056) , 618-623
The Big and the Small: Challenges of Imaging the Brain’s Circuits
The relation between the structure of the nervous system and its function is more poorly understood than the relation between structure and function in any other organ system. We explore why bridging the structure-function divide is uniquely difficult in the brain. These difficulties also explain the thrust behind the enormous amount of innovation centered on microscopy in neuroscience. We highlight some recent progress and the challenges that remain.
- 1 October 2004
- Published by Optica Publishing Group in Optics Letters
- Vol. 29 (19) , 2255-2257
Coherence-gated wave-front sensing in strongly scattering samples
We show that, by coherence-gate rejection of out-of-focus light, wave-front distortions can be measured in the presence of a scattering background that is dominant by several orders of magnitude. Applications are expected for multiphoton and confocal laser-scanning microscopy.
- 1 October 2004
- Published by Optica Publishing Group in Optics Letters
- Vol. 29 (19) , 2255-2257
Coherence-gated wave-front sensing in strongly scattering samples
We show that, by coherence-gate rejection of out-of-focus light, wave-front distortions can be measured in the presence of a scattering background that is dominant by several orders of magnitude. Applications are expected for multiphoton and confocal laser-scanning microscopy.