Yoshimune Ogata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yoshimune Ogata has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Kunihide Nishizawa
4 shared publications- Chisato Takenaka
Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan
2 shared publications - Hajime Ozawa
Fukushima Prefectural Forestry Research Centre, Koriyama, Fukushima 963-0112, Japan
2 shared publications S. Kojima
Aichi Medical University, Aichi, Japan
2 shared publicationsSadao Kojima
Aichi Medical University
2 shared publicationsSeiichi Yamamoto
Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
2 shared publications
Latest Publications
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 172-176
Estimation of 134 Cs activity by a new approximation referred to the sum-peak method via a well-type Ge detector
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 172-176
Estimation of 134 Cs activity by a new approximation referred to the sum-peak method via a well-type Ge detector
- 13 March 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 316 (3) , 1145-1149
Determination of 134Cs activity with the sum-peak method using a well-type germanium detector
- 13 March 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 316 (3) , 1145-1149
Determination of 134Cs activity with the sum-peak method using a well-type germanium detector
- 1 March 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 109, 354-357
Development of the modified sum-peak method and its application
- 1 March 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 109, 354-357
Development of the modified sum-peak method and its application
- 1 January 2016
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 151, 250-257
Radiocesium accumulation properties of Chengiopanax sciadophylloides
- 1 January 2016
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 151, 250-257
Radiocesium accumulation properties of Chengiopanax sciadophylloides
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 084301
Development of a prototype Open-close positron emission tomography system
We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.
- 1 August 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (8) , 084301
Development of a prototype Open-close positron emission tomography system
We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.
- 30 November 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 81, 119-122
High sensitive airborne radioiodine monitor
- 30 November 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 81, 119-122
High sensitive airborne radioiodine monitor
- 1 May 2011
- Published by Wolters Kluwer Health in Health Physics
- Vol. 100 (5) , S60-S66
Distribution of Thermal Neutron Flux Around a PET Cyclotron
The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and 11C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 106 cm−2 s−1 and 1.7 × 106 cm−2 s−1 during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 105 cm−2 s−1 and 1.2 × 105 cm−2 s−1, respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm−2 s−1, which corresponded to 0.1 μSv h−1 in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit.
- 1 May 2011
- Published by Wolters Kluwer Health in Health Physics
- Vol. 100 (5) , S60-S66
Distribution of Thermal Neutron Flux Around a PET Cyclotron
The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and 11C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 106 cm−2 s−1 and 1.7 × 106 cm−2 s−1 during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 105 cm−2 s−1 and 1.2 × 105 cm−2 s−1, respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm−2 s−1, which corresponded to 0.1 μSv h−1 in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit.
- 17 June 2007
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 273 (1) , 253-256
Radioactivity measurement with a plastic scintillation vial
- 17 June 2007
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 273 (1) , 253-256
Radioactivity measurement with a plastic scintillation vial