Pierre Bleuet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pierre Bleuet has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Peter Cloetens
European Synchrotron Radiation Facility
3 shared publications F. Lorut
STMicroelectronics, 850 rue Jean Monnet, Crolles 38926, France
2 shared publicationsG. Audoit
Univ. Grenoble Alpes, Grenoble F-38000, France; CEA, LETI, MINATEC Campus, Grenoble F-38054, France
2 shared publicationsJ. Bertheau
ST Microelectronics, 850 Rue Jean Monnet, 38920 Crolles, France
2 shared publicationsA. Farcy
STMicroelectronics, 850 rue Jean Monnet, Crolles 38926, France
1 shared publicationA. Fraczkiewicz
Univ. Grenoble Alpes, Grenoble F-38000, France; CEA, LETI, MINATEC Campus, Grenoble F-38054, France
1 shared publication
Latest Publications
- Open Access
- 22 April 2020
- Published by MDPI AG in Instruments
- Vol. 4 (2) , 11
TomoPress—In Situ Synchrotron-Based Microtomography under Axial Load
Computed tomography (CT) with hard X-rays is a mature technique that is in regular use to depict the interior of opaque specimens with spatial resolutions up to the micrometre range (microtomography or µCT). Short acquisition times and sophisticated contrast modes are accessible when synchrotron light sources are combined with microtomography—SR-µCT. Both features render SR-µCT as excellent probe to study delicate samples in situ, for example under mechanical load by deploying corresponding sample environments. The so-called TomoPress is such a device available within the public user programme of tomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). It allows one to study samples under high axial load (up to 500 N) with high spatial resolution up to the micrometer range. Different gauges are installed to allow online monitoring of the applied force. Constant humidity, temperature and wetting are routinely available as well. The article shall outline basic design principles of the press as well as parameters for its utilisation in a descriptive manner. Selected examples underline the potential of the device for such diverse fields as biomedical research, life sciences and materials research.
- 22 April 2020
- Published by MDPI AG in Instruments
- Vol. 4 (2) , 11
Open AccessTomoPress—In Situ Synchrotron-Based Microtomography under Axial Load
Computed tomography (CT) with hard X-rays is a mature technique that is in regular use to depict the interior of opaque specimens with spatial resolutions up to the micrometre range (microtomography or µCT). Short acquisition times and sophisticated contrast modes are accessible when synchrotron light sources are combined with microtomography—SR-µCT. Both features render SR-µCT as excellent probe to study delicate samples in situ, for example under mechanical load by deploying corresponding sample environments. The so-called TomoPress is such a device available within the public user programme of tomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). It allows one to study samples under high axial load (up to 500 N) with high spatial resolution up to the micrometer range. Different gauges are installed to allow online monitoring of the applied force. Constant humidity, temperature and wetting are routinely available as well. The article shall outline basic design principles of the press as well as parameters for its utilisation in a descriptive manner. Selected examples underline the potential of the device for such diverse fields as biomedical research, life sciences and materials research.
- 1 October 2018
- Published by Elsevier in Ultramicroscopy
- Vol. 193, 71-83
3D high resolution imaging for microelectronics: A multi-technique survey on copper pillars
- 1 October 2018
- Published by Elsevier in Ultramicroscopy
- Vol. 193, 71-83
3D high resolution imaging for microelectronics: A multi-technique survey on copper pillars
- 1 January 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 56, 78-84
In-situ X-ray μLaue diffraction study of copper through-silicon vias
- 1 January 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 56, 78-84
In-situ X-ray μLaue diffraction study of copper through-silicon vias
- 20 May 2014
- Published by Springer Nature in Journal of Materials Science
- Vol. 49 (16) , 5626-5634
Multi-scale 3D imaging of absorbing porous materials for solid oxide fuel cells
- 20 May 2014
- Published by Springer Nature in Journal of Materials Science
- Vol. 49 (16) , 5626-5634
Multi-scale 3D imaging of absorbing porous materials for solid oxide fuel cells
- 7 August 2013
- Published by Elsevier in Microelectronic Engineering
- Vol. 113, 123-129
Reflow processes in micro-bumps studied by synchrotron X-ray projection nanotomography
- 7 August 2013
- Published by Elsevier in Microelectronic Engineering
- Vol. 113, 123-129
Reflow processes in micro-bumps studied by synchrotron X-ray projection nanotomography
- 10 April 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (3) , 726-739
Specifications for Hard Condensed Matter Specimens for Three-Dimensional High-Resolution Tomographies
Tomography is a standard and invaluable technique that covers a large range of length scales. It gives access to the inner morphology of specimens and to the three-dimensional (3D) distribution of physical quantities such as elemental composition, crystalline phases, oxidation state, or strain. These data are necessary to determine the effective properties of investigated heterogeneous media. However, each tomographic technique relies on severe sampling conditions and physical principles that require the sample to be adequately shaped. For that purpose, a wide range of sample preparation techniques is used, including mechanical machining, polishing, sawing, ion milling, or chemical techniques. Here, we focus on the basics of tomography that justify such advanced sample preparation, before reviewing and illustrating the main techniques. Performances and limits are highlighted, and we identify the best preparation technique for a particular tomographic scale and application. The targeted tomography techniques include hard X-ray micro- and nanotomography, electron nanotomography, and atom probe tomography. The article mainly focuses on hard condensed matter, including porous materials, alloys, and microelectronics applications, but also includes, to a lesser extent, biological considerations.
- 10 April 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (3) , 726-739
Specifications for Hard Condensed Matter Specimens for Three-Dimensional High-Resolution Tomographies
Tomography is a standard and invaluable technique that covers a large range of length scales. It gives access to the inner morphology of specimens and to the three-dimensional (3D) distribution of physical quantities such as elemental composition, crystalline phases, oxidation state, or strain. These data are necessary to determine the effective properties of investigated heterogeneous media. However, each tomographic technique relies on severe sampling conditions and physical principles that require the sample to be adequately shaped. For that purpose, a wide range of sample preparation techniques is used, including mechanical machining, polishing, sawing, ion milling, or chemical techniques. Here, we focus on the basics of tomography that justify such advanced sample preparation, before reviewing and illustrating the main techniques. Performances and limits are highlighted, and we identify the best preparation technique for a particular tomographic scale and application. The targeted tomography techniques include hard X-ray micro- and nanotomography, electron nanotomography, and atom probe tomography. The article mainly focuses on hard condensed matter, including porous materials, alloys, and microelectronics applications, but also includes, to a lesser extent, biological considerations.
- 1 February 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (2) , 023708
Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data
While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.
- 1 February 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (2) , 023708
Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data
While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.