Kenneth H. Carlson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kenneth H. Carlson has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ji-Hee Son
Colorado State University
3 shared publications Jongmun Cha
Colorado State University
2 shared publicationsShinwoo Yang
Department of Civil and Environmental Engineering, Colorado State University, Fort Collins, CO 80523-1372, USA
2 shared publications- Chester C. Watson
U.S. Geological Survey, 1201 West University Avenue, Suite 100, Urbana, IL 61801
1 shared publication Cortney Cowley
Dep. of Civil and Environmental Engineering, Colorado State Univ., Fort Collins, CO, 80523
1 shared publication- David S. Biedenharn
Chief, Hydraulics Section, U.S. Army Corps of Engineers, Vicksburg District, 4155 E. Clay St., Vicksburg, MS 39183
1 shared publication
Latest Publications
- 1 January 2016
- Published by Elsevier in Water Research
- Vol. 88, 458-466
Concurrence of aqueous and gas phase contamination of groundwater in the Wattenberg oil and gas field of northern Colorado
- 1 January 2016
- Published by Elsevier in Water Research
- Vol. 88, 458-466
Concurrence of aqueous and gas phase contamination of groundwater in the Wattenberg oil and gas field of northern Colorado
- Open Access
- 1 May 2014
- Published by Springer Nature in Applied Water Science
- Vol. 5 (3) , 283-289
Real-time surrogate analysis for potential oil and gas contamination of drinking water resources
- 1 May 2014
- Published by Springer Nature in Applied Water Science
- Vol. 5 (3) , 283-289
Open AccessReal-time surrogate analysis for potential oil and gas contamination of drinking water resources
- 1 March 2013
- Published by Wiley in Journal of Environmental Quality
- Vol. 42 (2) , 497-506
Relative Phosphorus Load Inputs from Wastewater Treatment Plants in a Northern Colorado Watershed
- 1 March 2013
- Published by Wiley in Journal of Environmental Quality
- Vol. 42 (2) , 497-506
Relative Phosphorus Load Inputs from Wastewater Treatment Plants in a Northern Colorado Watershed
- 18 September 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 14 (11) , 2921-2928
Will stringent total nitrogen wastewater treatment plant discharge regulations achieve stream water quality goals?
The Colorado Department of Public Health and Environment (CDPHE) proposed the in-stream numeric nutrient criteria as 2 mg TN per L and 0.16 mg TP per L for warm surface waters and 0.40 mg TN per L and 0.11 mg TP per L for cold surface waters. Consequently the department presented the nutrient limits for the municipal wastewater treatment plants (WWTPs) as annual averages of 0.7 mg TP per L and 5.7 mg TIN per L and quarterly averages of 1.0 mg TP per L and 9.0 mg TIN per L. Implementing stringent nutrient reduction at point sources is unlikely to result in improvements to the environment without non-point source controls. In this study, total nitrogen (TN) load inputs from known point source, WWTPs, and other non-point sources at six sub-basins of the Cache La Poudre (CLP) River Basin were estimated and compared under various hydrologic conditions. Significant loading exceedance from the proposed limits was observed during lower flow conditions and other sources dominated during events when the exceedance was observed except for one point. The point receives direct TN inputs from a WWTP which has the highest TN concentration in its effluent among all WWTPs in the study area; however, TN loads entered the point from other sources were significant during higher flow conditions. TN loads in the CLP River were simulated to determine whether the loads meet the proposed in-stream limits in a case in which all WWTPs comply with the proposed regulations for WWTPs. From this study, it was observed that reducing TN concentrations only at WWTPs merely impacts total TN loads in the river.
- 18 September 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 14 (11) , 2921-2928
Will stringent total nitrogen wastewater treatment plant discharge regulations achieve stream water quality goals?
The Colorado Department of Public Health and Environment (CDPHE) proposed the in-stream numeric nutrient criteria as 2 mg TN per L and 0.16 mg TP per L for warm surface waters and 0.40 mg TN per L and 0.11 mg TP per L for cold surface waters. Consequently the department presented the nutrient limits for the municipal wastewater treatment plants (WWTPs) as annual averages of 0.7 mg TP per L and 5.7 mg TIN per L and quarterly averages of 1.0 mg TP per L and 9.0 mg TIN per L. Implementing stringent nutrient reduction at point sources is unlikely to result in improvements to the environment without non-point source controls. In this study, total nitrogen (TN) load inputs from known point source, WWTPs, and other non-point sources at six sub-basins of the Cache La Poudre (CLP) River Basin were estimated and compared under various hydrologic conditions. Significant loading exceedance from the proposed limits was observed during lower flow conditions and other sources dominated during events when the exceedance was observed except for one point. The point receives direct TN inputs from a WWTP which has the highest TN concentration in its effluent among all WWTPs in the study area; however, TN loads entered the point from other sources were significant during higher flow conditions. TN loads in the CLP River were simulated to determine whether the loads meet the proposed in-stream limits in a case in which all WWTPs comply with the proposed regulations for WWTPs. From this study, it was observed that reducing TN concentrations only at WWTPs merely impacts total TN loads in the river.
- 13 March 2008
- Published by American Society of Civil Engineers (ASCE)
Using UV235 as a TOC Surrogate for intentional Contaminant Detection in Drinking Water Distribution Systems
Detecting chemical contaminants in water distribution systems has traditionally been accomplished by grab sampling techniques or more recently, using high-end process analyzers such as TOC (total organic carbon). The method presented in this paper uses an online UV254 analyzer to look for chemical contamination events. The results of seven "particularly hazardous" chemicals and three baseline chemicals are presented, along with laboratory analysis of each, showing the viability of using UV254 for quickly investigating and detecting contamination events at a much lower cost than with traditional instruments or grab sampling techniques. This paper was presented at the 8th Annual Water Distribution Systems Analysis Symposium which was held with the generous support of Awwa Research Foundation (AwwaRF).
- 13 March 2008
- Published by American Society of Civil Engineers (ASCE)
Using UV235 as a TOC Surrogate for intentional Contaminant Detection in Drinking Water Distribution Systems
Detecting chemical contaminants in water distribution systems has traditionally been accomplished by grab sampling techniques or more recently, using high-end process analyzers such as TOC (total organic carbon). The method presented in this paper uses an online UV254 analyzer to look for chemical contamination events. The results of seven "particularly hazardous" chemicals and three baseline chemicals are presented, along with laboratory analysis of each, showing the viability of using UV254 for quickly investigating and detecting contamination events at a much lower cost than with traditional instruments or grab sampling techniques. This paper was presented at the 8th Annual Water Distribution Systems Analysis Symposium which was held with the generous support of Awwa Research Foundation (AwwaRF).
- 18 July 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (4) , 1301-1315
Quantification of human and veterinary antibiotics in water and sediment using SPE/LC/MS/MS
An analytical method was developed and tested for four different groups of veterinary antibiotics in both river water and sediment matrices. Solid phase extraction (SPE) was used to enrich and to clean up the aqueous sample. Also, Mcllvaine and ammonium hydroxide buffer solutions were used to extract the compounds from the sediment matrix. High performance liquid chromatography (HPLC) equipped with tandem mass spectrometry (MS/MS) was used to separate and quantify the samples. The range of recoveries (in percent) for tetracyclines (TCs), sulfonamides (SAs), macrolides (MLs), and ionophore polyethers (IPs) in the water matrix were 102.2–124.8, 76.6–124.3, 89.5–114.7, 82.7–117.5 with 1–13 (%) of relative standard deviation respectively with three different concentrations. For sediment, the percent recovery ranges were 32.8–114.8, 62.4–108.9, 53.4–128.4 and 51.3–105.4 for TCs, SAs, MLs and IPs, respectively. The relative standard deviation ranged from 16 – 27 (%) over three different concentrations. The limit of quantification (LOQ) was determined by two different methods and calculated to be in the range of 0.01–0.04 μg/l and 0.3–2.5 μg/kg for TCs, SAs, and MLs in water and sediment, respectively. For IPs, the LOQ was 0.001–0.003 μg/l in river water and 0.4–3.6 μg/kg for sediment. The sediment concentration measured in an agriculture-influenced river was much higher than in the overlying water matrix, indicating a high degree of sediment partitioning for these compounds.
- 18 July 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (4) , 1301-1315
Quantification of human and veterinary antibiotics in water and sediment using SPE/LC/MS/MS
An analytical method was developed and tested for four different groups of veterinary antibiotics in both river water and sediment matrices. Solid phase extraction (SPE) was used to enrich and to clean up the aqueous sample. Also, Mcllvaine and ammonium hydroxide buffer solutions were used to extract the compounds from the sediment matrix. High performance liquid chromatography (HPLC) equipped with tandem mass spectrometry (MS/MS) was used to separate and quantify the samples. The range of recoveries (in percent) for tetracyclines (TCs), sulfonamides (SAs), macrolides (MLs), and ionophore polyethers (IPs) in the water matrix were 102.2–124.8, 76.6–124.3, 89.5–114.7, 82.7–117.5 with 1–13 (%) of relative standard deviation respectively with three different concentrations. For sediment, the percent recovery ranges were 32.8–114.8, 62.4–108.9, 53.4–128.4 and 51.3–105.4 for TCs, SAs, MLs and IPs, respectively. The relative standard deviation ranged from 16 – 27 (%) over three different concentrations. The limit of quantification (LOQ) was determined by two different methods and calculated to be in the range of 0.01–0.04 μg/l and 0.3–2.5 μg/kg for TCs, SAs, and MLs in water and sediment, respectively. For IPs, the LOQ was 0.001–0.003 μg/l in river water and 0.4–3.6 μg/kg for sediment. The sediment concentration measured in an agriculture-influenced river was much higher than in the overlying water matrix, indicating a high degree of sediment partitioning for these compounds.
- 13 July 2005
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Watershed Approach to Stream Stability and Benefits Related to the Reduction of Nutrients
A number of streams in the hill area of north central Mississippi have been experiencing varying degrees of instability for the last several decades. This instability, bed degradation and bank failure, has resulted in numerous problems including damage to local infrastructure, the loss of productive agricultural land, deposition in flood control channels, and environmental degradation. The Mississippi Delta Headwaters Project (formerly the Demonstration Erosion Control Project) administered by the Vicksburg District of the Corps of Engineers has been successful in stabilizing some of these streams. The Mississippi Delta Headwaters Project (MDHP) restores stream stability at a reasonable cost by addressing problems in the entire drainage basin, i.e. the systems approach.
- 13 July 2005
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Watershed Approach to Stream Stability and Benefits Related to the Reduction of Nutrients
A number of streams in the hill area of north central Mississippi have been experiencing varying degrees of instability for the last several decades. This instability, bed degradation and bank failure, has resulted in numerous problems including damage to local infrastructure, the loss of productive agricultural land, deposition in flood control channels, and environmental degradation. The Mississippi Delta Headwaters Project (formerly the Demonstration Erosion Control Project) administered by the Vicksburg District of the Corps of Engineers has been successful in stabilizing some of these streams. The Mississippi Delta Headwaters Project (MDHP) restores stream stability at a reasonable cost by addressing problems in the entire drainage basin, i.e. the systems approach.
- 13 August 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (18) , 2131-2145
Quantitative determination of trace concentrations of tetracycline and sulfonamide antibiotics in surface water using solid‐phase extraction and liquid chromatography/ion trap tandem mass spectrometry
The occurrence of human and veterinary pharmaceutical compounds in surface waters (e.g. streams, lakes and reservoirs) is an important emerging environmental issue. There is a need for robust, sensitive and reliable analytical methods for measuring these compounds in a variety of natural water and wastewater matrices. This paper describes a method for the determination of seven tetracycline (TC) and six sulfonamide (SA) compounds in pristine and wastewater‐influenced surface water using solid‐phase extraction, and LCQ Duo ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) with positive electrospray ionization (ESI(+)) and selected reaction monitoring (SRM). The seven TCs and six SAs analyzed using this method include oxytetracycline (OTC), chlortetracycline (CTC), tetracycline (TC), democlocycline (DMC), doxycycline (DXC), meclocycline (MCC), minocycline (MNC), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfachloropyridazine (SCP), sulfamethoxazole (SMX), and sulfadimethoxane (SDM). This study discusses the effects of flow rate, LC column diameter and LC column temperature on UV and/or mass peak quality of the different analytes. Several product ions for MS/MS detection have been identified and compared for ion trap and triple quadrupole LC/MS/MS instruments. Statistical analysis for determination of the method detection limit (MDL), accuracy and precision of the method is described. Matrix effects are evaluated in deionized, pristine and wastewater‐influenced river water. The method is applied to evaluate the occurrence of these compounds in a small watershed in northern Colorado. Copyright © 2004 John Wiley & Sons, Ltd.
- 13 August 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (18) , 2131-2145
Quantitative determination of trace concentrations of tetracycline and sulfonamide antibiotics in surface water using solid‐phase extraction and liquid chromatography/ion trap tandem mass spectrometry
The occurrence of human and veterinary pharmaceutical compounds in surface waters (e.g. streams, lakes and reservoirs) is an important emerging environmental issue. There is a need for robust, sensitive and reliable analytical methods for measuring these compounds in a variety of natural water and wastewater matrices. This paper describes a method for the determination of seven tetracycline (TC) and six sulfonamide (SA) compounds in pristine and wastewater‐influenced surface water using solid‐phase extraction, and LCQ Duo ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) with positive electrospray ionization (ESI(+)) and selected reaction monitoring (SRM). The seven TCs and six SAs analyzed using this method include oxytetracycline (OTC), chlortetracycline (CTC), tetracycline (TC), democlocycline (DMC), doxycycline (DXC), meclocycline (MCC), minocycline (MNC), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfachloropyridazine (SCP), sulfamethoxazole (SMX), and sulfadimethoxane (SDM). This study discusses the effects of flow rate, LC column diameter and LC column temperature on UV and/or mass peak quality of the different analytes. Several product ions for MS/MS detection have been identified and compared for ion trap and triple quadrupole LC/MS/MS instruments. Statistical analysis for determination of the method detection limit (MDL), accuracy and precision of the method is described. Matrix effects are evaluated in deionized, pristine and wastewater‐influenced river water. The method is applied to evaluate the occurrence of these compounds in a small watershed in northern Colorado. Copyright © 2004 John Wiley & Sons, Ltd.
- 1 June 2000
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 126 (6) , 556-561
Optimizing Water Treatment with Two-Stage Coagulation
Drinking water utilities are facing increasing regulatory pressure to optimize treatment processes, particularly the filtration process that is relied on as a physical barrier to pathogen contamination. In the presence of high concentrations of natural organic matter, traditional coagulation processes can be inadequate to meet these future standards. In this study, a natural water with a high total organic carbon concentration (>6 mg/L) was used to compare one- and two-stage alum coagulation processes. The two-stage coagulation process involved the application of alum at two locations separated by approximately 60 s of detention time. Bench-scale experiments were conducted with various water quality conditions and verified at the pilot scale. The settled-water turbidity was 25% less using the two-stage process, and the steady-state filter effluent particle counts for the two-stage process were approximately 50% lower than for the single-stage process. More importantly, the two-stage process did not exhibit particle breakthrough during a typical filter run, whereas the one-stage process broke through 3 h before the hydraulic completion of the run. Additional bench-scale experiments allowed a mechanism for the improved process performance to be proposed.
- 1 June 2000
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 126 (6) , 556-561
Optimizing Water Treatment with Two-Stage Coagulation
Drinking water utilities are facing increasing regulatory pressure to optimize treatment processes, particularly the filtration process that is relied on as a physical barrier to pathogen contamination. In the presence of high concentrations of natural organic matter, traditional coagulation processes can be inadequate to meet these future standards. In this study, a natural water with a high total organic carbon concentration (>6 mg/L) was used to compare one- and two-stage alum coagulation processes. The two-stage coagulation process involved the application of alum at two locations separated by approximately 60 s of detention time. Bench-scale experiments were conducted with various water quality conditions and verified at the pilot scale. The settled-water turbidity was 25% less using the two-stage process, and the steady-state filter effluent particle counts for the two-stage process were approximately 50% lower than for the single-stage process. More importantly, the two-stage process did not exhibit particle breakthrough during a typical filter run, whereas the one-stage process broke through 3 h before the hydraulic completion of the run. Additional bench-scale experiments allowed a mechanism for the improved process performance to be proposed.