Alberto Cordero-Dávila
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alberto Cordero-Dávila has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jorge González-García
Universidad Tecnológica de la Mixteca
4 shared publications - Carlos Robledo-Sanchez
Benemérita Univ. Autónoma de Puebla (Mexico)
3 shared publications Diego Gabriel Reyes-Olguín
Benemérita Universidad Autónoma de Puebla
3 shared publicationsIrce Leal-Cabrera
Instituto de Óptica, Instituto Nacional de Astrofísica, Óptica y Electrónica (INAOE), Santa María, Tonantzintla Puebla, Apartado Postal 51 y 216, Mexico
2 shared publicationsJorge Cuautle-Cortés
2 shared publicationsJorge González-García
BUAP, FCFM, Av San Claudio & Rio Verde S-N, Puebla 72570, Pue, Mexico
2 shared publications
Latest Publications
- 23 February 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , 1800-1806
Exact formula to relate optical path differences and transversal aberration components
An exact equation to relate the optical path differences (OPD) with its transversal aberration components (TAC) is determined. The OPD-TAC equation reproduces the Rayces formula and introduces the coefficient for the longitudinal aberration. The defocus orthonormal Zernike polynomial (ZDF) is not a solution for the OPD-TAC equation since the obtained longitudinal defocus depends on the ray height on the exit pupil, meaning that it cannot be interpreted as a defocus. In order to find an exact expression for OPD defocus, first, a general relation-ship between the wavefront shape and its OPD is established. Second, an exact formula for the defocus OPD is established. Finally, it is proved that only the exact defocus OPD is an exact solution of the exact OPD-TAC equation.(c) 2023 Optica Publishing Group
- 23 February 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , 1800-1806
Exact formula to relate optical path differences and transversal aberration components
An exact equation to relate the optical path differences (OPD) with its transversal aberration components (TAC) is determined. The OPD-TAC equation reproduces the Rayces formula and introduces the coefficient for the longitudinal aberration. The defocus orthonormal Zernike polynomial (ZDF) is not a solution for the OPD-TAC equation since the obtained longitudinal defocus depends on the ray height on the exit pupil, meaning that it cannot be interpreted as a defocus. In order to find an exact expression for OPD defocus, first, a general relation-ship between the wavefront shape and its OPD is established. Second, an exact formula for the defocus OPD is established. Finally, it is proved that only the exact defocus OPD is an exact solution of the exact OPD-TAC equation.(c) 2023 Optica Publishing Group
- 2 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (8) , 1876-1884
Proof that spot diagram borders are always caustic curves and/or marginal rays II: annular (circular and elliptical) and single hexagonal exit pupils
In a previous paper [Appl. Opt. 61, C20 (2022)], it was proven that for a circular exit pupil and any optical path differences, the border of any spot diagram is integrated by the caustic surface and/or marginal rays. In this paper, the previous results are extended to annular (circular an elliptical) as well as hexagonal (single and segmented) exit pupils. Several examples of wavefronts affected by linear combinations of orthonormal Zernike aberrations are shown. (C) 2022 Optica Publishing Group
- 2 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (8) , 1876-1884
Proof that spot diagram borders are always caustic curves and/or marginal rays II: annular (circular and elliptical) and single hexagonal exit pupils
In a previous paper [Appl. Opt. 61, C20 (2022)], it was proven that for a circular exit pupil and any optical path differences, the border of any spot diagram is integrated by the caustic surface and/or marginal rays. In this paper, the previous results are extended to annular (circular an elliptical) as well as hexagonal (single and segmented) exit pupils. Several examples of wavefronts affected by linear combinations of orthonormal Zernike aberrations are shown. (C) 2022 Optica Publishing Group
- 11 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (6) , C20-C26
Borders of spot diagrams are always caustic surfaces and/or marginal rays
In this paper, it is proven that for any optical system with a circular exit pupil and wavefronts affected by any aberrations, the borders of all leaving rays are caustic surfaces and/or marginal rays. Several examples are shown for wavefronts affected by linear combinations of Zernike aberrations. (C) 2021 Optical Society of America
- 11 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (6) , C20-C26
Borders of spot diagrams are always caustic surfaces and/or marginal rays
In this paper, it is proven that for any optical system with a circular exit pupil and wavefronts affected by any aberrations, the borders of all leaving rays are caustic surfaces and/or marginal rays. Several examples are shown for wavefronts affected by linear combinations of Zernike aberrations. (C) 2021 Optical Society of America
- 29 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , 6737-6743
Exact calculation of conic constants and baffles for any two-mirror aplanatic telescope
To calculate the conic constants of the primary and secondary mirrors of any aplanatic two-mirror telescope, nonexact equations have been used considering third-order approximations, although it was not considered that there is an infinite number of conic constants. In this paper, exact nonlinear equations are obtained; with them, the two conic constants of the mirrors are calculated without approximations. We also find that the conic constants depend on the position at the stop where the calculation is carried out, and there are always residual aberrations. In addition, a procedure is established for the exact calculation of the baffles. Finally, examples show the differences between exact and third-order calculations.
- 29 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , 6737-6743
Exact calculation of conic constants and baffles for any two-mirror aplanatic telescope
To calculate the conic constants of the primary and secondary mirrors of any aplanatic two-mirror telescope, nonexact equations have been used considering third-order approximations, although it was not considered that there is an infinite number of conic constants. In this paper, exact nonlinear equations are obtained; with them, the two conic constants of the mirrors are calculated without approximations. We also find that the conic constants depend on the position at the stop where the calculation is carried out, and there are always residual aberrations. In addition, a procedure is established for the exact calculation of the baffles. Finally, examples show the differences between exact and third-order calculations.
- 17 February 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (6) , 1726-1731
Lensometer with autocollimation and a square Ronchi grid
A lensometer based on an autocollimation system and a square Ronchi grid was designed, constructed, and tested. Refractive powers of monofocal, astigmatic, bifocal, and progressive lenses were measured. The focal plane was identified when no spots, or a minimum number of fringes, are observed on the bironchigram (pattern with a square Ronchi grid). For cylindrical lenses, the spots were transformed in fringes along the x and y directions from which the cylindrical and spherical powers were obtained. For the progressive lenses, a zero spots circle moved on the bironchigram plane along the umbilic zone while the square Ronchi grid was moved along the optical axis. This lensometer is compact, cheap, and precise. Our measurements and errors were very similar to those obtained with a commercial lensometer.
- 17 February 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (6) , 1726-1731
Lensometer with autocollimation and a square Ronchi grid
A lensometer based on an autocollimation system and a square Ronchi grid was designed, constructed, and tested. Refractive powers of monofocal, astigmatic, bifocal, and progressive lenses were measured. The focal plane was identified when no spots, or a minimum number of fringes, are observed on the bironchigram (pattern with a square Ronchi grid). For cylindrical lenses, the spots were transformed in fringes along the x and y directions from which the cylindrical and spherical powers were obtained. For the progressive lenses, a zero spots circle moved on the bironchigram plane along the umbilic zone while the square Ronchi grid was moved along the optical axis. This lensometer is compact, cheap, and precise. Our measurements and errors were very similar to those obtained with a commercial lensometer.
- 18 November 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8785
Implementation of a semi-automatic robotic system for alignment in the Ronchi test
In this paper, we propose the design of a robotic system to semi-automatically align components in the Ronchi test; the robotic system will align the Ronchi tester with the surface being tested. In this work, we present the control system design of a rail system with two degrees of freedom, which allows semiautomatic alignment of the Ronchi tester with the surface in production. Informative visual markings (IVM) are used to achieve this [1]. The IVM help locate the system coordinates of the optical surface with respect to the basic system coordinates of the rail system. Quantification of the alignment is performed using the value of non-integer interference order, which is calculated to generate the simulated ronchigram which more closely resembles the experimental ronchigram [2].
- 18 November 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8785
Implementation of a semi-automatic robotic system for alignment in the Ronchi test
In this paper, we propose the design of a robotic system to semi-automatically align components in the Ronchi test; the robotic system will align the Ronchi tester with the surface being tested. In this work, we present the control system design of a rail system with two degrees of freedom, which allows semiautomatic alignment of the Ronchi tester with the surface in production. Informative visual markings (IVM) are used to achieve this [1]. The IVM help locate the system coordinates of the optical surface with respect to the basic system coordinates of the rail system. Quantification of the alignment is performed using the value of non-integer interference order, which is calculated to generate the simulated ronchigram which more closely resembles the experimental ronchigram [2].
- 16 August 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (24) , 4817-4823
Local and global surface errors evaluation using Ronchi test, without both approximation and integration.
We have reproduced quantitatively the technique commonly used in optical shop to evaluate surface error from comparison between experimental and simulated Ronchigrams. We used this procedure to evaluate, from Ronchigrams of any number of fringes, the curvature radius and/or conic constant of conic surfaces. The error function is calculated without using integration (numerical or polynomial) so the corresponding problems were avoided. Furthermore, when the error function is described with cubic splines, then the local errors are very well reproduced, which is not the case with the polynomial description. We have described the error functions with conical surfaces or with cubic splines, and for the best reproduction of experimental Ronchigram we used genetic algorithms.
- 16 August 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (24) , 4817-4823
Local and global surface errors evaluation using Ronchi test, without both approximation and integration.
We have reproduced quantitatively the technique commonly used in optical shop to evaluate surface error from comparison between experimental and simulated Ronchigrams. We used this procedure to evaluate, from Ronchigrams of any number of fringes, the curvature radius and/or conic constant of conic surfaces. The error function is calculated without using integration (numerical or polynomial) so the corresponding problems were avoided. Furthermore, when the error function is described with cubic splines, then the local errors are very well reproduced, which is not the case with the polynomial description. We have described the error functions with conical surfaces or with cubic splines, and for the best reproduction of experimental Ronchigram we used genetic algorithms.
- 20 August 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (24) , 6126-6136
Calculating petal tools by using genetic algorithms
To pass from a spherical surface to a conic one, it is possible to use a petal tool or a small solid tool that is placed at different time intervals at several radial zones of the glass. Genetic algorithms are applied to calculate the angular sizes of the incomplete annular tools that make up the petal tools. We also present the desired wear results carried out with the petal tool that was designed on the basis of the dwell times of complete annular tools. These dwell times are calculated by using base functions that are generated with annular tools and by applying the genetic algorithms.
- 20 August 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (24) , 6126-6136
Calculating petal tools by using genetic algorithms
To pass from a spherical surface to a conic one, it is possible to use a petal tool or a small solid tool that is placed at different time intervals at several radial zones of the glass. Genetic algorithms are applied to calculate the angular sizes of the incomplete annular tools that make up the petal tools. We also present the desired wear results carried out with the petal tool that was designed on the basis of the dwell times of complete annular tools. These dwell times are calculated by using base functions that are generated with annular tools and by applying the genetic algorithms.
- 20 February 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (6) , 1250-1254
Edge effects with the Preston equation for a circular tool and workpiece
In a polishing process the wear is greater at the edge when the tool extends beyond the border of the workpiece. To explain this effect, we propose a new model in which the pressure is higher at the edge. This model is applied to the case of a circular tool that polishes a circular workpiece. Our model correctly predicts that a greater amount of material is removed from the edge of the workpiece.
- 20 February 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (6) , 1250-1254
Edge effects with the Preston equation for a circular tool and workpiece
In a polishing process the wear is greater at the edge when the tool extends beyond the border of the workpiece. To explain this effect, we propose a new model in which the pressure is higher at the edge. This model is applied to the case of a circular tool that polishes a circular workpiece. Our model correctly predicts that a greater amount of material is removed from the edge of the workpiece.