Hiroshige Yamabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroshige Yamabe has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
Hisao Ogawa
National Cerebral and Cardiovascular Center, Suita City, Osaka, Japan
16 shared publicationsHisanori Kanazawa
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
11 shared publicationsJunjiroh Koyama
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
8 shared publicationsKenji Morihisa
Division of Cardiology, Kumamoto Central Hospital, Kumamoto City, Kumamoto Japan
8 shared publicationsTadashi Hoshiyama
Division of Cardiology, Kumamoto Chuo Hospital, Kumamoto, Japan
7 shared publicationsTakashi Uemura
Division of Cardiology, Kumamoto General Hospital, Yatsushiro City, Kumamoto, Japan
7 shared publications
Latest Publications
- 7 December 2024
- Published by Springer Nature in Heart and Vessels
- Vol. 40 (7) , 636-646
Maintenance mechanism of paroxysmal atrial fibrillation from the activation occurring within the pulmonary vein: analysis using non-contact mapping
It is unclear how pulmonary veins (PVs) maintain paroxysmal atrial fibrillation (AF). To clarify the PV’s arrhythmogenic role, we examined PV activation sequences during paroxysmal AF. Left superior PV (LSPV) endocardial non-contact mapping was performed after a right PV isolation in 13 paroxysmal AF patients. Activation sequences within the LSPV before and during left-sided PVs ablation were analyzed, and those in complex fractionated atrial electrogram (CFAE) areas were compared with those in non-CFAE areas. CFAEs were observed in the LSPV’s proximal half (area; 8.8 ± 3.2cm2) occupying 19.9 ± 6.0% of LSPV. The number of pivoting activations, wave breaks, and fusions over CFAE areas were significantly higher than those over non-CFE areas (25.5 ± 9.3 vs. 4.5 ± 4.8 times/s, p < 0.0001; 9.1 ± 5.3 vs. 1.4 ± 1.8 times/s, p < 0.0001; 13.0 ± 4.6 vs. 5.4 ± 4.4 times/s, p < 0.0001). The conduction velocities in CFAE areas were significantly slower than in non-CFAE areas (0.6 ± 0.2 vs. 1.7 ± 0.8 m/s, p < 0.001). After delivery of ablation lesions around the left-sided PVs (13.2 ± 7.4 applications), the PV activation became organized with a loss of CFAE areas, and the frequency of the LSPV’s pivoting activation, wave break, and fusion significantly decreased compared to that pre-ablation (7.3 ± 10.9 vs. 30.0 ± 11.6 times/s, p < 0.001; 2.1 ± 5.3 vs. 10.5 ± 6.2 times/s, p < 0.002; 6.0 ± 6.6 vs. 18.4 ± 8.2 times/s, p < 0.001). Subsequently, AF terminated before the left-sided PV isolation in all patients. In conclusion, high-frequency random reentry associated with pivoting activation, wave break, and fusion within the LSPV, observed mostly over CFAE areas, maintained AF. Linear ablation lesions around the PV suppressed random reentry, resulting in the loss of CFAEs and AF termination.
- 7 December 2024
- Published by Springer Nature in Heart and Vessels
- Vol. 40 (7) , 636-646
Maintenance mechanism of paroxysmal atrial fibrillation from the activation occurring within the pulmonary vein: analysis using non-contact mapping
It is unclear how pulmonary veins (PVs) maintain paroxysmal atrial fibrillation (AF). To clarify the PV’s arrhythmogenic role, we examined PV activation sequences during paroxysmal AF. Left superior PV (LSPV) endocardial non-contact mapping was performed after a right PV isolation in 13 paroxysmal AF patients. Activation sequences within the LSPV before and during left-sided PVs ablation were analyzed, and those in complex fractionated atrial electrogram (CFAE) areas were compared with those in non-CFAE areas. CFAEs were observed in the LSPV’s proximal half (area; 8.8 ± 3.2cm2) occupying 19.9 ± 6.0% of LSPV. The number of pivoting activations, wave breaks, and fusions over CFAE areas were significantly higher than those over non-CFE areas (25.5 ± 9.3 vs. 4.5 ± 4.8 times/s, p < 0.0001; 9.1 ± 5.3 vs. 1.4 ± 1.8 times/s, p < 0.0001; 13.0 ± 4.6 vs. 5.4 ± 4.4 times/s, p < 0.0001). The conduction velocities in CFAE areas were significantly slower than in non-CFAE areas (0.6 ± 0.2 vs. 1.7 ± 0.8 m/s, p < 0.001). After delivery of ablation lesions around the left-sided PVs (13.2 ± 7.4 applications), the PV activation became organized with a loss of CFAE areas, and the frequency of the LSPV’s pivoting activation, wave break, and fusion significantly decreased compared to that pre-ablation (7.3 ± 10.9 vs. 30.0 ± 11.6 times/s, p < 0.001; 2.1 ± 5.3 vs. 10.5 ± 6.2 times/s, p < 0.002; 6.0 ± 6.6 vs. 18.4 ± 8.2 times/s, p < 0.001). Subsequently, AF terminated before the left-sided PV isolation in all patients. In conclusion, high-frequency random reentry associated with pivoting activation, wave break, and fusion within the LSPV, observed mostly over CFAE areas, maintained AF. Linear ablation lesions around the PV suppressed random reentry, resulting in the loss of CFAEs and AF termination.
- 29 January 2021
- Published by Springer Nature in Heart and Vessels
- Vol. 36 (8) , 1-11
Comparison of the catheter ablation outcome in patients between targeting the entrance and exit of the reentry circuit in verapamil-sensitive atrial tachycardia originating from the atrioventricular-node vicinity
Verapamil-sensitive atrial tachycardia originating from the atrioventricular node vicinity (AVN-AT) can be eliminated with radiofrequency energy (RF) deliveries targeting either the entrance or exit of its reentry circuit. However, the outcome of these different approaches has not been clarified well. Thus, we compared the catheter ablation outcome targeting the entrance of reentry circuit, identified by the entrainment method (Ent-Group; 21 patients) with that targeting the earliest atrial activation site (EAAS) during AT (Exit-Group; 16 patients). There was no significant difference in the tachycardia cycle length (441.4 ± 87.4 vs. 392.8 ± 64.8 ms, p = 0.0704) or distance from the His bundle (HB) site to the EAAS (6.5 ± 2.0 vs. 7.6 ± 1.8 mm, p = 0.0822) between the Ent- and Exit-Groups. However, distance from the successful ablation site to the HB site in the Ent-Group was significantly longer than that in the Exit-Group (13.4 ± 3.1 vs. 7.6 ± 1.8 mm, p < 0.0001), resulting in more frequent transient atrioventricular block episodes in the Exit-Group than Ent-Group (31.3 vs. 0%, p < 0.01). Initial ATs (AT1s) were terminated in all patients in both Groups. However, ATs accompanied by shifting in the EAAS (AT2) were induced more frequently in the Exit-Group than Ent-Group (50.0 vs. 14.3%, p < 0.02) after eliminating AT1. RF deliveries to the EAAS eliminated all AT2s. The number of RF deliveries was greater in the Exit-Group than Ent-Group (6.9 ± 3.3 vs. 3.9 ± 1.6, p < 0.001). In conclusion, RF ablation targeting the entrance sites can avoid AVN injury and is superior in reducing the number of RF deliveries and occurrence of different ATs than targeting the exit sites in the AVN-AT.
- 29 January 2021
- Published by Springer Nature in Heart and Vessels
- Vol. 36 (8) , 1-11
Comparison of the catheter ablation outcome in patients between targeting the entrance and exit of the reentry circuit in verapamil-sensitive atrial tachycardia originating from the atrioventricular-node vicinity
Verapamil-sensitive atrial tachycardia originating from the atrioventricular node vicinity (AVN-AT) can be eliminated with radiofrequency energy (RF) deliveries targeting either the entrance or exit of its reentry circuit. However, the outcome of these different approaches has not been clarified well. Thus, we compared the catheter ablation outcome targeting the entrance of reentry circuit, identified by the entrainment method (Ent-Group; 21 patients) with that targeting the earliest atrial activation site (EAAS) during AT (Exit-Group; 16 patients). There was no significant difference in the tachycardia cycle length (441.4 ± 87.4 vs. 392.8 ± 64.8 ms, p = 0.0704) or distance from the His bundle (HB) site to the EAAS (6.5 ± 2.0 vs. 7.6 ± 1.8 mm, p = 0.0822) between the Ent- and Exit-Groups. However, distance from the successful ablation site to the HB site in the Ent-Group was significantly longer than that in the Exit-Group (13.4 ± 3.1 vs. 7.6 ± 1.8 mm, p < 0.0001), resulting in more frequent transient atrioventricular block episodes in the Exit-Group than Ent-Group (31.3 vs. 0%, p < 0.01). Initial ATs (AT1s) were terminated in all patients in both Groups. However, ATs accompanied by shifting in the EAAS (AT2) were induced more frequently in the Exit-Group than Ent-Group (50.0 vs. 14.3%, p < 0.02) after eliminating AT1. RF deliveries to the EAAS eliminated all AT2s. The number of RF deliveries was greater in the Exit-Group than Ent-Group (6.9 ± 3.3 vs. 3.9 ± 1.6, p < 0.001). In conclusion, RF ablation targeting the entrance sites can avoid AVN injury and is superior in reducing the number of RF deliveries and occurrence of different ATs than targeting the exit sites in the AVN-AT.
- 3 January 2019
- Published by Springer Nature in Heart and Vessels
- Vol. 34 (6) , 1014-1023
Analysis of the preferable site and stability of rotational reentry: its role for the maintenance of atrial fibrillation
It remains unclear whether AF is maintained by rotor. We evaluated the significance of rotor during atrial fibrillation (AF). Prevalence, location, and stability of rotational reentry (RR) in the left atrium were clarified by endocardial non-contact mapping in 66 AF patients. RR was classified into three categories: RR continued at stable site (Stable-RR), RR observed intermittently at the same site (Intermittent-RR), and RR observed at different locations (Different-RR). Catheter ablation was performed in a stepwise fashion (linear roof lesion and complex fractionated atrial electrogram ablation following pulmonary vein isolation) until AF termination and elucidated the consequence of radiofrequency lesion delivered within RR site on AF termination and recurrence. One hundred and nineteen RRs were observed. There were 54 patients with RR (RR Group) and 22 patients without RR (Non-RR Group). Prevalence of Different-RR (n = 81) was significantly higher than Stable-RR (n = 16, p < 0.001) and Intermittent-RR (n = 22, p < 0.001). The intervals involved in RR occupied only 22.4% of total activation time. There was no significant difference in the prevalence of AF termination nor AF/atrial tachycardia recurrence between RR and non-RR Groups (46 vs. 9 patients, p = 0.317, and 13 vs. 1 patients, p = 0.271) and between patients in whom radiofrequency lesion was involved in RR and those was not (24 vs. 22 patients, p = 0.210, and 6 vs. 7 patients, p = 0.506). In conclusion, most RRs were observed transiently and often shifted its locations. Radiofrequency lesion delivered within RR site did not correlate with AF termination nor recurrence, suggesting that RR is not a driving source during AF.
- 3 January 2019
- Published by Springer Nature in Heart and Vessels
- Vol. 34 (6) , 1014-1023
Analysis of the preferable site and stability of rotational reentry: its role for the maintenance of atrial fibrillation
It remains unclear whether AF is maintained by rotor. We evaluated the significance of rotor during atrial fibrillation (AF). Prevalence, location, and stability of rotational reentry (RR) in the left atrium were clarified by endocardial non-contact mapping in 66 AF patients. RR was classified into three categories: RR continued at stable site (Stable-RR), RR observed intermittently at the same site (Intermittent-RR), and RR observed at different locations (Different-RR). Catheter ablation was performed in a stepwise fashion (linear roof lesion and complex fractionated atrial electrogram ablation following pulmonary vein isolation) until AF termination and elucidated the consequence of radiofrequency lesion delivered within RR site on AF termination and recurrence. One hundred and nineteen RRs were observed. There were 54 patients with RR (RR Group) and 22 patients without RR (Non-RR Group). Prevalence of Different-RR (n = 81) was significantly higher than Stable-RR (n = 16, p < 0.001) and Intermittent-RR (n = 22, p < 0.001). The intervals involved in RR occupied only 22.4% of total activation time. There was no significant difference in the prevalence of AF termination nor AF/atrial tachycardia recurrence between RR and non-RR Groups (46 vs. 9 patients, p = 0.317, and 13 vs. 1 patients, p = 0.271) and between patients in whom radiofrequency lesion was involved in RR and those was not (24 vs. 22 patients, p = 0.210, and 6 vs. 7 patients, p = 0.506). In conclusion, most RRs were observed transiently and often shifted its locations. Radiofrequency lesion delivered within RR site did not correlate with AF termination nor recurrence, suggesting that RR is not a driving source during AF.
- 1 December 2018
- Published by Elsevier in Journal of Cardiology
- Vol. 72 (6) , 480-487
Analysis for the primary predictive factor for the incidence of esophageal injury after ablation of atrial fibrillation
- 1 December 2018
- Published by Elsevier in Journal of Cardiology
- Vol. 72 (6) , 480-487
Analysis for the primary predictive factor for the incidence of esophageal injury after ablation of atrial fibrillation
- Open Access
- 17 July 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (14)
Slow Potential at the Entrance of the Slow Conduction Zone in the Reentry Circuit of a Verapamil‐Sensitive Atrial Tachycardia Originating From the Atrioventricular Annulus
Background: Slow conduction zone in a verapamil‐sensitive reentrant atrial tachycardia originating from atrioventricular annulus is composed of calcium channel–dependent tissue. We examined whether there was a slow potential ( SP ) at the entrance of the slow conduction zone. Methods and Results: We first identified the pacing site from where manifest entrainment and orthodromic capture of the earliest atrial activation site were demonstrated in 40 atrioventricular annulus patients with atrioventricular annulus. Radiofrequency energy was then delivered 2 cm proximal to the earliest atrial activation site in the direction of entrainment pacing site and gradually advanced toward the earliest atrial activation site until atrial tachycardia termination to localize the entrance of the slow conduction zone. Electrogram characteristics were analyzed at successful and unsuccessful ablation sites. During sinus rhythm, SP was observed at all 40 successful sites, but was observed at only 12 unsuccessful sites ( P P =0.1989] and 37.0±9.2 versus 38.9±8.0 ms [ P =0.1773]); however, SP amplitude and width at successful sites were significantly greater than those at unsuccessful sites (0.110±0.049 versus 0.025±0.046 mV [ P P P P <0.0001) at successful sites. Conclusions: SP was observed during sinus rhythm at the entrance of the slow conduction zone; however, SP amplitude was attenuated and SP width was prolonged during atrial tachycardia, suggesting that SP reflects the characteristics of calcium channel–dependent tissue involved in atrioventricular annulus reentry circuit.
- 17 July 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (14)
Open AccessSlow Potential at the Entrance of the Slow Conduction Zone in the Reentry Circuit of a Verapamil‐Sensitive Atrial Tachycardia Originating From the Atrioventricular Annulus
Background: Slow conduction zone in a verapamil‐sensitive reentrant atrial tachycardia originating from atrioventricular annulus is composed of calcium channel–dependent tissue. We examined whether there was a slow potential ( SP ) at the entrance of the slow conduction zone. Methods and Results: We first identified the pacing site from where manifest entrainment and orthodromic capture of the earliest atrial activation site were demonstrated in 40 atrioventricular annulus patients with atrioventricular annulus. Radiofrequency energy was then delivered 2 cm proximal to the earliest atrial activation site in the direction of entrainment pacing site and gradually advanced toward the earliest atrial activation site until atrial tachycardia termination to localize the entrance of the slow conduction zone. Electrogram characteristics were analyzed at successful and unsuccessful ablation sites. During sinus rhythm, SP was observed at all 40 successful sites, but was observed at only 12 unsuccessful sites ( P P =0.1989] and 37.0±9.2 versus 38.9±8.0 ms [ P =0.1773]); however, SP amplitude and width at successful sites were significantly greater than those at unsuccessful sites (0.110±0.049 versus 0.025±0.046 mV [ P P P P <0.0001) at successful sites. Conclusions: SP was observed during sinus rhythm at the entrance of the slow conduction zone; however, SP amplitude was attenuated and SP width was prolonged during atrial tachycardia, suggesting that SP reflects the characteristics of calcium channel–dependent tissue involved in atrioventricular annulus reentry circuit.
- 1 February 2018
- Published by Elsevier in Journal of Cardiology
- Vol. 71 (2) , 129-134
Study on the Effect of Irbesartan on Atrial Fibrillation Recurrence in Kumamoto: Atrial Fibrillation Suppression Trial (SILK study)
- 1 February 2018
- Published by Elsevier in Journal of Cardiology
- Vol. 71 (2) , 129-134
Study on the Effect of Irbesartan on Atrial Fibrillation Recurrence in Kumamoto: Atrial Fibrillation Suppression Trial (SILK study)
- 23 September 2017
- Published by Springer Nature
- p. 109-117
Adenosine-Sensitive Atrial Tachycardia
- 1 December 2016
- Published by Elsevier in Heart Rhythm
- Vol. 13 (12) , 2323-2330
Prevalence and mechanism of rotor activation identified during atrial fibrillation by noncontact mapping: Lack of evidence for a role in the maintenance of atrial fibrillation
- 1 December 2016
- Published by Elsevier in Heart Rhythm
- Vol. 13 (12) , 2323-2330
Prevalence and mechanism of rotor activation identified during atrial fibrillation by noncontact mapping: Lack of evidence for a role in the maintenance of atrial fibrillation
- Open Access
- 1 May 2016
- Published by Elsevier in Clinical Trials and Regulatory Science in Cardiology
- Vol. 17, 9-14
Helicobacter pylori-seropositivity along with pro-inflammatory interleukin-1 polymorphisms correlated with myocardial infarction
- 1 May 2016
- Published by Elsevier in Clinical Trials and Regulatory Science in Cardiology
- Vol. 17, 9-14
Open AccessHelicobacter pylori-seropositivity along with pro-inflammatory interleukin-1 polymorphisms correlated with myocardial infarction