Martin Seifert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martin Seifert has a total of 163 co-authors. Here are the top co-authors by number of shared publications:
C. Butter
Department of Cardiology, Heart Center Brandenburg and Medical School Brandenburg Theodor Fontane, Ladeburger Str. 17, 16321, Bernau bei Berlin, Germany
8 shared publicationsChristian Butter
Department of Cardiology, Heart Center Brandenburg, Bernau/Berlin, and Medical School Brandenburg, Germany
4 shared publications- Christian Butter
Department of Cardiology, Immanuel Clinic Bernau, Heart Center Brandenburg, Bernau, Germany
3 shared publications M. Neuss
Ev.-Freikirchliches Hospital and Heart Center Brandenburg in Bernau, Bernau bei Berlin, Germany
3 shared publicationsMichael Neuss
Heart Center Brandenburg, Department of Cardiology, Ladeburger Str. 17, D-16321 Bernau bei Berlin, Germany
3 shared publicationsT. Schau
Ev.-Freikirchliches Hospital and Heart Center Brandenburg in Bernau, Bernau bei Berlin, Germany
3 shared publications
Latest Publications
- 1 October 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (10) , e010877
Impact of Physical Activity in Patients With Atrial Fibrillation Undergoing Catheter Ablation: The Multicenter Randomized BE-ACTION Trial
BACKGROUND: Arrhythmia recurrence after pulmonary vein isolation (PVI) is common. We conducted a multicenter, randomized trial to determine the impact of increased physical activity on atrial fibrillation recurrence after PVI. METHODS: From 2018 to 2020, we randomly assigned 200 patients with atrial fibrillation to the ACTION or NO-ACTION group in 4 different centers in the local country of Brandenburg, Germany. Patients were eligible if they were scheduled to undergo PVI, aged ≥50 to ≤77 years, body mass index ≥23 to ≤35 kg/m 2 , and accepted wearing an activity tracker allowing 24-hour activity monitoring via mobile app. Patients in the ACTION group were actively remote-controlled via transmitted activity data by a physiotherapist, and individual motivational interviewing call sessions were scheduled with each ACTION patient every 2 weeks. The primary end point was the composite of recurrence of any atrial arrhythmia >30 seconds, additional ablation procedure, cardioversion, and new onset of antiarrhythmic drugs earliest after 90 days after index PVI over 12 months. RESULTS: Overall, the median age of patients was 66 (interquartile range, 61–71) years, 33.5% were women, and 52% had persistent atrial fibrillation. The number of steps per day increased in both groups of patients from baseline to 12 months ( P P =0.325. Unadjusted intention-to-treat analysis showed no difference in the primary composite end point in the ACTION group (27.3%) versus the NO-ACTION group (32.7%), P =0.405. CONCLUSIONS: Physical activity improved in patients after PVI. The present randomized controlled trial shows that activity tracker and motivational calls to increase physical activity versus activity tracker alone did not reduce the occurrence of the primary composite end point of atrial fibrillation recurrence or the absolute increase in steps per day. REGISTRATION: URL: https://www.cochranelibrary.com ; Unique identifier: DRKS00012914.
- 1 October 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (10) , e010877
Impact of Physical Activity in Patients With Atrial Fibrillation Undergoing Catheter Ablation: The Multicenter Randomized BE-ACTION Trial
BACKGROUND: Arrhythmia recurrence after pulmonary vein isolation (PVI) is common. We conducted a multicenter, randomized trial to determine the impact of increased physical activity on atrial fibrillation recurrence after PVI. METHODS: From 2018 to 2020, we randomly assigned 200 patients with atrial fibrillation to the ACTION or NO-ACTION group in 4 different centers in the local country of Brandenburg, Germany. Patients were eligible if they were scheduled to undergo PVI, aged ≥50 to ≤77 years, body mass index ≥23 to ≤35 kg/m 2 , and accepted wearing an activity tracker allowing 24-hour activity monitoring via mobile app. Patients in the ACTION group were actively remote-controlled via transmitted activity data by a physiotherapist, and individual motivational interviewing call sessions were scheduled with each ACTION patient every 2 weeks. The primary end point was the composite of recurrence of any atrial arrhythmia >30 seconds, additional ablation procedure, cardioversion, and new onset of antiarrhythmic drugs earliest after 90 days after index PVI over 12 months. RESULTS: Overall, the median age of patients was 66 (interquartile range, 61–71) years, 33.5% were women, and 52% had persistent atrial fibrillation. The number of steps per day increased in both groups of patients from baseline to 12 months ( P P =0.325. Unadjusted intention-to-treat analysis showed no difference in the primary composite end point in the ACTION group (27.3%) versus the NO-ACTION group (32.7%), P =0.405. CONCLUSIONS: Physical activity improved in patients after PVI. The present randomized controlled trial shows that activity tracker and motivational calls to increase physical activity versus activity tracker alone did not reduce the occurrence of the primary composite end point of atrial fibrillation recurrence or the absolute increase in steps per day. REGISTRATION: URL: https://www.cochranelibrary.com ; Unique identifier: DRKS00012914.
- 2 October 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 58 (3) , 347-353
Impact of mapping points in high-density mapping of the left atrium
Currently, high-density mapping techniques are being discussed for more precise voltage mapping, lesion validation after pulmonary vein isolation (PVI) and superior left atrial tachycardia (LAT) mapping. However, the quality of high-density maps varies according to different mapping systems, multipolar catheter (MPC) types and numbers of mapping points. The aim of this study was to evaluate the impact of different numbers of mapping points in high-density mapping on validity.
- 2 October 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 58 (3) , 347-353
Impact of mapping points in high-density mapping of the left atrium
Currently, high-density mapping techniques are being discussed for more precise voltage mapping, lesion validation after pulmonary vein isolation (PVI) and superior left atrial tachycardia (LAT) mapping. However, the quality of high-density maps varies according to different mapping systems, multipolar catheter (MPC) types and numbers of mapping points. The aim of this study was to evaluate the impact of different numbers of mapping points in high-density mapping on validity.
- 10 April 2019
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 30 (2) , 197-203
Septikämie und Endokarditis bei multiplen Implantaten
Septikämien, vor allem aber infektiöse Endokarditiden sind mit einer hohen Mortalität verbunden. Mit dem Vorhandensein von Implantaten (Fremdmaterial) erschwert sich die Diagnostik und Behandlung zusätzlich. Die Symptome der Patienten sind sehr variabel. Deswegen werden Septikämien und Endokarditiden häufig erst relativ spät diagnostiziert. Sowohl die Bildgebung mittels transösophagealer Echokardiographie (TEE) als auch die Mikrobiologie sind die Eckpfeiler der Diagnostik. Sie dienen aber ebenso zur Kontrolle während der Behandlung. Neben der antibiotischen Therapie ist zumindest bei Vegetationsnachweis auch eine Entfernung der Implantate erforderlich. Nicht nur die Extraktion der Implantate, sondern insbesondere die kardiale Grunderkrankung, die häufig vorhandene schwere Herzinsuffizienz, das fortgeschrittene Alter und die nicht selten hohe Fragilität der Patienten machen die Entscheidungsfindung bei der Therapie, das Management der Behandlung sowie die erneute Implantation nach abgeschlossener Behandlung zu einer Herausforderung. Die optimale Behandlung ist nur bei enger Zusammenarbeit zwischen unterschiedlichen Fachdisziplinen möglich und sollte deswegen in erfahrenen Zentren erfolgen. Infective endocarditis (IE) as well as septicemia in patients with implanted cardiac devices are severe diseases and diagnosis is often delayed due to a variety of misleading symptoms. Imaging with transesophageal echocardiography (TEE) and also microbiology play a key role in both the diagnosis and management. They are also useful for the prognostic assessment of patients with IE, for follow-up during treatment, during extraction of the implant and after surgery. In addition to antibiotic treatment, removal of the implant is also necessary, at least if vegetation is detected. Not only the removal of the implant but also the underlying cardiac disease, the frequently occurring severe cardiac insufficiency, the advanced age and the not uncommon high degree of fragility of the patients mean that decision making for treatment and management as well as renewed implantation after completion of treatment are a challenge. The optimal treatment is only possible with a close cooperation between various specialist disciplines and should therefore be carried out in experienced centers.
- 10 April 2019
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 30 (2) , 197-203
Septikämie und Endokarditis bei multiplen Implantaten
Septikämien, vor allem aber infektiöse Endokarditiden sind mit einer hohen Mortalität verbunden. Mit dem Vorhandensein von Implantaten (Fremdmaterial) erschwert sich die Diagnostik und Behandlung zusätzlich. Die Symptome der Patienten sind sehr variabel. Deswegen werden Septikämien und Endokarditiden häufig erst relativ spät diagnostiziert. Sowohl die Bildgebung mittels transösophagealer Echokardiographie (TEE) als auch die Mikrobiologie sind die Eckpfeiler der Diagnostik. Sie dienen aber ebenso zur Kontrolle während der Behandlung. Neben der antibiotischen Therapie ist zumindest bei Vegetationsnachweis auch eine Entfernung der Implantate erforderlich. Nicht nur die Extraktion der Implantate, sondern insbesondere die kardiale Grunderkrankung, die häufig vorhandene schwere Herzinsuffizienz, das fortgeschrittene Alter und die nicht selten hohe Fragilität der Patienten machen die Entscheidungsfindung bei der Therapie, das Management der Behandlung sowie die erneute Implantation nach abgeschlossener Behandlung zu einer Herausforderung. Die optimale Behandlung ist nur bei enger Zusammenarbeit zwischen unterschiedlichen Fachdisziplinen möglich und sollte deswegen in erfahrenen Zentren erfolgen. Infective endocarditis (IE) as well as septicemia in patients with implanted cardiac devices are severe diseases and diagnosis is often delayed due to a variety of misleading symptoms. Imaging with transesophageal echocardiography (TEE) and also microbiology play a key role in both the diagnosis and management. They are also useful for the prognostic assessment of patients with IE, for follow-up during treatment, during extraction of the implant and after surgery. In addition to antibiotic treatment, removal of the implant is also necessary, at least if vegetation is detected. Not only the removal of the implant but also the underlying cardiac disease, the frequently occurring severe cardiac insufficiency, the advanced age and the not uncommon high degree of fragility of the patients mean that decision making for treatment and management as well as renewed implantation after completion of treatment are a challenge. The optimal treatment is only possible with a close cooperation between various specialist disciplines and should therefore be carried out in experienced centers.
- Open Access
- 14 February 2019
- Published by Wiley in Case Reports in Cardiology
- Vol. 2019, 1-4
105 Inappropriate ICD Shocks in a Patient with Dilated Cardiomyopathy and Broca’s Aphasia
With a growing number of ICD recipients, device complications are seen more frequently in the clinical setting and outpatient departments. Among the most severe are ICD infections and inappropriate therapies caused by oversensing of atrial tachycardias or lead fracture. We report on a 76-year-old female patient with dilative cardiomyopathy and Broca’s aphasia after stroke, who experienced 105 consecutive inappropriate ICD shocks due to cluster missensing of her fractured ICD lead. The diagnosis was complicated and delayed by patient’s aphasia emphasizing the need for intensified remote monitoring along with regular in-person visits, especially in people with intellectual or communication disabilities.
- 14 February 2019
- Published by Wiley in Case Reports in Cardiology
- Vol. 2019, 1-4
Open Access105 Inappropriate ICD Shocks in a Patient with Dilated Cardiomyopathy and Broca’s Aphasia
With a growing number of ICD recipients, device complications are seen more frequently in the clinical setting and outpatient departments. Among the most severe are ICD infections and inappropriate therapies caused by oversensing of atrial tachycardias or lead fracture. We report on a 76-year-old female patient with dilative cardiomyopathy and Broca’s aphasia after stroke, who experienced 105 consecutive inappropriate ICD shocks due to cluster missensing of her fractured ICD lead. The diagnosis was complicated and delayed by patient’s aphasia emphasizing the need for intensified remote monitoring along with regular in-person visits, especially in people with intellectual or communication disabilities.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i107
542Impact of ghosts prior second CRT Implantation after complete CRT extraction caused by device related infection
Background: At this time more and more small residual fibrinous strands or masses remain within the RA, RV and/or SVC after lead extraction, so-called ghosts, come to the focus of calculation prognosis in patients after device extraction. The goal of this study was at the first time to look to the impact of ghosts to patients with indication for a CRT device after complete CRT extraction caused by device related infection.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i107
542Impact of ghosts prior second CRT Implantation after complete CRT extraction caused by device related infection
Background: At this time more and more small residual fibrinous strands or masses remain within the RA, RV and/or SVC after lead extraction, so-called ghosts, come to the focus of calculation prognosis in patients after device extraction. The goal of this study was at the first time to look to the impact of ghosts to patients with indication for a CRT device after complete CRT extraction caused by device related infection.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i224
P1168Ultra high density mapping depicts local reentries causing atrial tachycardia in patients after pulmonary venous ablation
Background: Ultra High Density (UHD) mapping allows more precise imaging of local reentry (LR) mechanisms. A new classification of three different LR types (type 1 LR, type 2 pseudo LR, type 3 artefact) has been introduced lately, though the clinical impact in left atrial ablations remains unclear.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i224
P1168Ultra high density mapping depicts local reentries causing atrial tachycardia in patients after pulmonary venous ablation
Background: Ultra High Density (UHD) mapping allows more precise imaging of local reentry (LR) mechanisms. A new classification of three different LR types (type 1 LR, type 2 pseudo LR, type 3 artefact) has been introduced lately, though the clinical impact in left atrial ablations remains unclear.
- 6 April 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (5) , 808-815
Prognosis associated with redo cardiac resynchronization therapy following complete device and lead extraction due to device-related infection
An increase in the number of cardiac resynchronization therapy (CRT) device implantations worldwide has led to a consequent increase in the number of infections associated with the device, making extraction of the CRT device inevitable. Redo CRT implantation after treatment and recovery following device extraction is challenging. This study aimed to evaluate the success rate, complications, and long-term prognosis of redo CRT implantation, including the rates of subclavian, cava, and coronary sinus (CS) vein thrombosis as well as re-infection. Between 2007 and 2014, 1712 lead extractions were performed in 537 patients with device-related infection at Heart Center Brandenburg. Of the 537 patients, 125 (23%) underwent CRT device and lead extraction, including extraction of the left ventricular lead from the coronary sinus. Of these 125, 62 (50%) patients underwent redo CRT implantation (mean age, 68 ± 10 years); 34 patients had coronary artery disease (CAD) while 28 had dilated cardiomyopathy (DCM). The mean left ventricular ejection fraction was 27% ± 7%. The mean QRS duration of the left bundle branch block was 158 (range, 147–162) ms, and 25 patients had atrial fibrillation (AF). All these patients were followed up for a median duration of 29.6 (range, 15–43) months. In 53 of the 62 patients (85%), the CRT system was successfully re-implanted; however, the original CS vein could be used again only in 28 (45%) patients. The all-cause mortality rate was 7.1% after 1 year, and it was significantly higher in patients whose N-terminal pro B-type natriuretic peptide level was ≥3,000 pg/mL (P < 0.001), those who were aged ≥64 years (P = 0.028), those who had CAD (P = 0.042) or chronic kidney insufficiency (P = 0.001), those with AF (P = 0.001) and those whose blood cultures were positive for Staphylococcus aureus (P = 0.014). Redo CRT implantation after device extraction owing to device-related infection has a low success rate and shows a higher rate of re-infection than that observed in patients who undergo CRT implantation for the first time. Further, patients whose blood cultures are positive for S. aureus show a particularly poor outcome.
- 6 April 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (5) , 808-815
Prognosis associated with redo cardiac resynchronization therapy following complete device and lead extraction due to device-related infection
An increase in the number of cardiac resynchronization therapy (CRT) device implantations worldwide has led to a consequent increase in the number of infections associated with the device, making extraction of the CRT device inevitable. Redo CRT implantation after treatment and recovery following device extraction is challenging. This study aimed to evaluate the success rate, complications, and long-term prognosis of redo CRT implantation, including the rates of subclavian, cava, and coronary sinus (CS) vein thrombosis as well as re-infection. Between 2007 and 2014, 1712 lead extractions were performed in 537 patients with device-related infection at Heart Center Brandenburg. Of the 537 patients, 125 (23%) underwent CRT device and lead extraction, including extraction of the left ventricular lead from the coronary sinus. Of these 125, 62 (50%) patients underwent redo CRT implantation (mean age, 68 ± 10 years); 34 patients had coronary artery disease (CAD) while 28 had dilated cardiomyopathy (DCM). The mean left ventricular ejection fraction was 27% ± 7%. The mean QRS duration of the left bundle branch block was 158 (range, 147–162) ms, and 25 patients had atrial fibrillation (AF). All these patients were followed up for a median duration of 29.6 (range, 15–43) months. In 53 of the 62 patients (85%), the CRT system was successfully re-implanted; however, the original CS vein could be used again only in 28 (45%) patients. The all-cause mortality rate was 7.1% after 1 year, and it was significantly higher in patients whose N-terminal pro B-type natriuretic peptide level was ≥3,000 pg/mL (P < 0.001), those who were aged ≥64 years (P = 0.028), those who had CAD (P = 0.042) or chronic kidney insufficiency (P = 0.001), those with AF (P = 0.001) and those whose blood cultures were positive for Staphylococcus aureus (P = 0.014). Redo CRT implantation after device extraction owing to device-related infection has a low success rate and shows a higher rate of re-infection than that observed in patients who undergo CRT implantation for the first time. Further, patients whose blood cultures are positive for S. aureus show a particularly poor outcome.
- Open Access
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i179
139-01: Wireless LV endocardial pacing for CRT, SELECT-LV Study: Ischaemic patients
Purpose: Pts implanted with conventional CRT (CRT) do not always benefit. Inability to place the CS lead, lead instability, and lack of clinical response to CRT are a few causes. Left Ventricular (LV) endocardial pacing has been proposed as a potential solution. The SELECT-LV study assessed the safety and performance of the novel Wireless Stimulation of the Endocardium System, (WiSE), to provide endocardial LV stimulation. This substudy has looked at the outcomes for the ischaemic patients, a difficult group to treat effectively with CRT. Methods: The SELECT-LV Study is a non-randomised EU study of CRT-indicated pts with either a failure of CRT, or requiring an upgrade but unsuitable for CRT. The WiSE System includes a leadless pacing electrode implanted on the LV free wall. A submuscular ultrasonic transmitter synchronised to the RV pacing pulse of a co-implanted pacer/ICD activates the electrode. The primary efficacy endpoint was successful BiV pacing, verified by ECG, at 1 m. Secondary endpoints were performance at 6m together with preliminary efficacy assessment. Summary of results: 15 (44%) of 34 total pts had ischaemic cardiomyopathy; all were successfully implanted. Baseline data: age 68 ± 7 yrs, 13 male, EF 24.1 ± 5.6 %, NYHA 2.7 ± 0.6 and baseline intrinsic QRS 168 ± 32 ms. One pt had a revision of battery and transmitter, 1 pt had a CVA, which resolved, after failing to follow the prescribed anticoagulation regimen and another had a groin aneurysm. Consistent BiV pacing was demonstrated in 15 (100%) pts at 1 and 6 m. Reductions in QRS duration from intrinsic baseline at 1 and 6m were 44 and 39 ms, and from the baseline RV paced QRS were 54 and 42 ms. The increase in EF at 6m was 6.4 ± 8.6% with 64.2% pts having ≥5% increase. NYHA class decreased to 1.8 ± 0.8. LV end systolic volume decrease was 15.4 ± 27.8 ml, with 45% and 55% of pts experiencing a 15% and 10% reduction respectively. Clinical composite score, including death, HF hospitalisation and global assessment, improved in 87% (13 pts), was unchanged in 6.6% (1 pt) and worsened in 6.6% (1 pt). Conclusion: Difficult to treat ischaemic pts implanted in the SELECT-LV study showed promising clinical outcomes.
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i179
Open Access139-01: Wireless LV endocardial pacing for CRT, SELECT-LV Study: Ischaemic patients
Purpose: Pts implanted with conventional CRT (CRT) do not always benefit. Inability to place the CS lead, lead instability, and lack of clinical response to CRT are a few causes. Left Ventricular (LV) endocardial pacing has been proposed as a potential solution. The SELECT-LV study assessed the safety and performance of the novel Wireless Stimulation of the Endocardium System, (WiSE), to provide endocardial LV stimulation. This substudy has looked at the outcomes for the ischaemic patients, a difficult group to treat effectively with CRT. Methods: The SELECT-LV Study is a non-randomised EU study of CRT-indicated pts with either a failure of CRT, or requiring an upgrade but unsuitable for CRT. The WiSE System includes a leadless pacing electrode implanted on the LV free wall. A submuscular ultrasonic transmitter synchronised to the RV pacing pulse of a co-implanted pacer/ICD activates the electrode. The primary efficacy endpoint was successful BiV pacing, verified by ECG, at 1 m. Secondary endpoints were performance at 6m together with preliminary efficacy assessment. Summary of results: 15 (44%) of 34 total pts had ischaemic cardiomyopathy; all were successfully implanted. Baseline data: age 68 ± 7 yrs, 13 male, EF 24.1 ± 5.6 %, NYHA 2.7 ± 0.6 and baseline intrinsic QRS 168 ± 32 ms. One pt had a revision of battery and transmitter, 1 pt had a CVA, which resolved, after failing to follow the prescribed anticoagulation regimen and another had a groin aneurysm. Consistent BiV pacing was demonstrated in 15 (100%) pts at 1 and 6 m. Reductions in QRS duration from intrinsic baseline at 1 and 6m were 44 and 39 ms, and from the baseline RV paced QRS were 54 and 42 ms. The increase in EF at 6m was 6.4 ± 8.6% with 64.2% pts having ≥5% increase. NYHA class decreased to 1.8 ± 0.8. LV end systolic volume decrease was 15.4 ± 27.8 ml, with 45% and 55% of pts experiencing a 15% and 10% reduction respectively. Clinical composite score, including death, HF hospitalisation and global assessment, improved in 87% (13 pts), was unchanged in 6.6% (1 pt) and worsened in 6.6% (1 pt). Conclusion: Difficult to treat ischaemic pts implanted in the SELECT-LV study showed promising clinical outcomes.
- 27 April 2016
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (6) , 523-531
Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure
Introduction: There are several unsolved limitations in delivering cardiac resynchronization therapy. 30-40% of patients fail to have any clinical benefit after 6 months caused by different reasons. Areas covered: Endocardial stimulation rather than conventional epicardial pacing has been shown to: be more physiologically, improve electrical stimulation of the left ventricular, give less dispersion of repolarisation and result in better resynchronization. The Wireless Cardiac Stimulation in Left Ventricle, WiCS-LV, system provides an option for wireless, left ventricular endocardial pacing triggered from a conventional right ventricular pacing spike from a co-implant. Expert commentary: The feasibility of the WiCS-LV system has been successfully demonstrated in a population of failed cardiac resynchronization patients, either failed implantation procedure of a conventional system, non-responder to conventional therapy or upgrade from pacemaker or defibrillator, where a conventional system was not an option. WiCS-LV is innovative technology with promising safety, performance and preliminary efficacy.
- 27 April 2016
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (6) , 523-531
Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure
Introduction: There are several unsolved limitations in delivering cardiac resynchronization therapy. 30-40% of patients fail to have any clinical benefit after 6 months caused by different reasons. Areas covered: Endocardial stimulation rather than conventional epicardial pacing has been shown to: be more physiologically, improve electrical stimulation of the left ventricular, give less dispersion of repolarisation and result in better resynchronization. The Wireless Cardiac Stimulation in Left Ventricle, WiCS-LV, system provides an option for wireless, left ventricular endocardial pacing triggered from a conventional right ventricular pacing spike from a co-implant. Expert commentary: The feasibility of the WiCS-LV system has been successfully demonstrated in a population of failed cardiac resynchronization patients, either failed implantation procedure of a conventional system, non-responder to conventional therapy or upgrade from pacemaker or defibrillator, where a conventional system was not an option. WiCS-LV is innovative technology with promising safety, performance and preliminary efficacy.
- 13 October 2015
- Published by Springer Nature in Herz
- Vol. 40 (7) , 966-971
Implantierbare hämodynamische Monitorsysteme
Heart failure is one of the most frequent diagnoses in hospital admissions in Germany. In the majority of these admissions acute decompensation of an already existing chronic heart failure is responsible. New mostly wireless and remote strategies for monitoring, titration, adaptation and optimization are the focus for improvement of the treatment of heart failure patients and the poor prognosis. The implantation of hemodynamic monitoring devices follows the hypothesis that significant changes in hemodynamic parameters occur before the occurrence of acute decompensation requiring readmission. Three different hemodynamic monitoring devices have so far been investigated in clinical trials employing right ventricular pressure, left atrial pressure and pulmonary artery pressure monitoring. Only one of these systems, the CardioMENS™ HF monitoring system, demonstrated a significant reduction of hospitalization due to heart failure over 6 months in the CHAMPION trial. The systematic adaptation of medication in the CHAMPION trial significantly differed from the usual care of the control arm over 6 months. This direct day to day management of diuretics is currently under intensive investigation; however, further studies demonstrating a positive effect on mortality are needed before translation of this approach into guidelines. Without this evidence a further implementation of pressure monitoring into currently used devices and justification of the substantial technical and personnel demands are not warranted.
- 13 October 2015
- Published by Springer Nature in Herz
- Vol. 40 (7) , 966-971
Implantierbare hämodynamische Monitorsysteme
Heart failure is one of the most frequent diagnoses in hospital admissions in Germany. In the majority of these admissions acute decompensation of an already existing chronic heart failure is responsible. New mostly wireless and remote strategies for monitoring, titration, adaptation and optimization are the focus for improvement of the treatment of heart failure patients and the poor prognosis. The implantation of hemodynamic monitoring devices follows the hypothesis that significant changes in hemodynamic parameters occur before the occurrence of acute decompensation requiring readmission. Three different hemodynamic monitoring devices have so far been investigated in clinical trials employing right ventricular pressure, left atrial pressure and pulmonary artery pressure monitoring. Only one of these systems, the CardioMENS™ HF monitoring system, demonstrated a significant reduction of hospitalization due to heart failure over 6 months in the CHAMPION trial. The systematic adaptation of medication in the CHAMPION trial significantly differed from the usual care of the control arm over 6 months. This direct day to day management of diuretics is currently under intensive investigation; however, further studies demonstrating a positive effect on mortality are needed before translation of this approach into guidelines. Without this evidence a further implementation of pressure monitoring into currently used devices and justification of the substantial technical and personnel demands are not warranted.