Renze Bais
Research Subjects
Renze Bais has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Mauro Panteghini
Department of Laboratory Medicine , Nicolaus Copernicus University, Collegium Medicum , Bydgoszcz , Poland
3 shared publications Aaron D. Bossler
1 shared publicationAlan L. Rockwood
1 shared publicationAlan Shenkin
1 shared publication- Alan Thomas Remaley
Section of Lipoprotein Metabolism, Translational Vascular Medicine Branch, and
1 shared publication - Alex J. Rai
The Johns Hopkins University School of Medicine, Department of Pathology, Division of Clinical Chemistry, Baltimore, MD 21287-7065, USA
1 shared publication
Latest Publications
- 1 February 2014
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 60 (2) , 413-414
More on Lot-to-Lot Changes
- 1 February 2014
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 60 (2) , 413-414
More on Lot-to-Lot Changes
- 23 September 2013
- Published by Elsevier in Clinica Chimica Acta
- Vol. 424, 1-2
Two cardiac troponin assays not affected by hemolysis — A patient safety issue
- 23 September 2013
- Published by Elsevier in Clinica Chimica Acta
- Vol. 424, 1-2
Two cardiac troponin assays not affected by hemolysis — A patient safety issue
- 23 March 2013
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (5) , 973-979
Defining acceptable limits for the metrological traceability of specific measurands
Although manufacturers are compelled by the European IVD Directive, 98/79/EC, to have traceability of the values assigned to their calibrators if suitable higher order reference materials and/or procedures are available, there is still no equivalence of results for many measurands determined in clinical laboratories. The adoption of assays with metrological traceable results will have a significant impact on laboratory medicine in that results will be equivalent across different laboratories and different analytical platforms. The IFCC WG on Allowable Errors for Traceable Results has been formed to define acceptable limits for metrological traceability chains for specific measurands in order to promote the equivalence of patient results. These limits are being developed based on biological variation for the specific measurands. Preliminary investigations have shown that for some measurands, it is possible for manufacturers to assign values to assay calibrators with a measurement uncertainty that allows the laboratory enough combined uncertainty for their routine measurements. However, for other measurands, e.g., plasma sodium, current assays are too imprecise to fulfil limits based on biological variation. Although an alternative approach based on probability theory is being investigated, the most desirable approach would be for industry to improve measurement methods so that they meet clinical requirements.
- 23 March 2013
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (5) , 973-979
Defining acceptable limits for the metrological traceability of specific measurands
Although manufacturers are compelled by the European IVD Directive, 98/79/EC, to have traceability of the values assigned to their calibrators if suitable higher order reference materials and/or procedures are available, there is still no equivalence of results for many measurands determined in clinical laboratories. The adoption of assays with metrological traceable results will have a significant impact on laboratory medicine in that results will be equivalent across different laboratories and different analytical platforms. The IFCC WG on Allowable Errors for Traceable Results has been formed to define acceptable limits for metrological traceability chains for specific measurands in order to promote the equivalence of patient results. These limits are being developed based on biological variation for the specific measurands. Preliminary investigations have shown that for some measurands, it is possible for manufacturers to assign values to assay calibrators with a measurement uncertainty that allows the laboratory enough combined uncertainty for their routine measurements. However, for other measurands, e.g., plasma sodium, current assays are too imprecise to fulfil limits based on biological variation. Although an alternative approach based on probability theory is being investigated, the most desirable approach would be for industry to improve measurement methods so that they meet clinical requirements.
- 1 January 2012
- Published by Elsevier
Contributors