Laure-Lise Gras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laure-Lise Gras has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Sébastien Laporte
Arts et Métiers ParisTech, Institut de Biomécanique Humaine George Charpak, 151 bd de l’Hopital, 75013 Paris, France
5 shared publicationsS. Laporte
Arts et Métiers ParisTech, Institut de Biomécanique Humaine Georges Charpak, LBM, 151 bd de l(׳)Hôpital, 75013 Paris, France
4 shared publicationsDavid Mitton
Université de Lyon, F-69622, Lyon, France Université Claude Bernard Lyon 1, Villeurbanne, France IFSTTAR, UMR_T9406, LBMC Laboratoire de Biomécanique et Mécanique des Chocs, F-69675, Bron, France
3 shared publications- A. Roux
Arts et Métiers ParisTech, Institut de Biomécanique Humaine Georges Charpak, LBM, 151 bd de l(׳)Hôpital, 75013 Paris, France; Arts et Métiers ParisTech. I2M. Esplanade des Arts et Métiers, 33405 Talence, France
2 shared publications - Anthony Viste
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
2 shared publications Antoine Combes
2 shared publications
Latest Publications
- Open Access
- 4 May 2026
- Published by Elsevier in SSRN Electronic Journal
Ex Vivo Mechanical Characterization of the Human Iliotibial Band under Tensile and Shear Loadings
The iliotibial band (ITB) is a connective tissue that contributes to the stability of the hip and knee joints. ITB is mainly made of two or three layers of oriented collagen fibers. It has been previously shown that shear is an important strain mechanism inside the ITB during passive leg movement. However, few studies report shear tests on ITB samples. Therefore, ITB samples were submitted to uniaxial tests along the two natural main fiber directions, named longitudinal and transverse, and to a shear test: the bias extension test. Stiffness was higher in the longitudinal direction than in the transverse direction. Longitudinal samples also exhibited an auxetic response compared to the transverse ones, which may be explained by the microstructure of the tissue. In the bias extension test, an important shear angle variation was measured, as well as fiber extension. The bias extension test confirmed that fasciae can shear and thus authorize elongations in specific directions above the maximum elongations that fibers can withstand. These results further highlight the importance of accounting for shear when modeling the ITB, the potential of bias extension tests for studying biological materials, and the possibility of adapting existing models developed for textile reinforcements.
- 4 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEx Vivo Mechanical Characterization of the Human Iliotibial Band under Tensile and Shear Loadings
The iliotibial band (ITB) is a connective tissue that contributes to the stability of the hip and knee joints. ITB is mainly made of two or three layers of oriented collagen fibers. It has been previously shown that shear is an important strain mechanism inside the ITB during passive leg movement. However, few studies report shear tests on ITB samples. Therefore, ITB samples were submitted to uniaxial tests along the two natural main fiber directions, named longitudinal and transverse, and to a shear test: the bias extension test. Stiffness was higher in the longitudinal direction than in the transverse direction. Longitudinal samples also exhibited an auxetic response compared to the transverse ones, which may be explained by the microstructure of the tissue. In the bias extension test, an important shear angle variation was measured, as well as fiber extension. The bias extension test confirmed that fasciae can shear and thus authorize elongations in specific directions above the maximum elongations that fibers can withstand. These results further highlight the importance of accounting for shear when modeling the ITB, the potential of bias extension tests for studying biological materials, and the possibility of adapting existing models developed for textile reinforcements.
- 19 November 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (7) , 2215-2226
Anterior cruciate ligament reconstruction with short hamstring grafts: the choice of femoral fixation device matters in controlling overall lengthening
Purpose: The purpose was to conduct an independent biomechanical study comparing the main types of femoral fixation adapted to short hamstring grafts in anterior cruciate ligament (ACL) reconstruction surgery and to validate their performance.Methods: The ACLip® Femoral, ToggleLoc™ Ziploop (TLZ), and Tape Locking Screw (TLS®) implants were tested in tension in the following three different configurations: implant alone, implant fixed on the femur without graft, and implant fixed on the femur with graft. Grafts alone were also tested. The femurs and the 4‐strand semi‐tendinosus grafts were derived from porcine and human models, respectively. Each set‐up was subjected to the same protocol of creep (50 N for 30 s), cycling (1000 cycles between 50 and 250 N, 1 Hz), and load to failure (50 mm/min).Results: A total of 93 tests were performed (30 ACLip®, 30 TLZ, 20 TLS®, and 13 ST4 alone). For the implants tested with femur and graft, the mean ± standard deviation (SD) overall elongation at 250 N after cycling was 5.2 ± 0.2 mm, 8.4 ± 2.1 mm, and 5.3 ± 0.8 mm, the mean ± SD ultimate load to failure was 736 ± 116 N, 830 ± 204 N, and 640 ± 242 N, and the mean ± SD stiffness at the 1000th cycle was 185 ± 15 N/mm, 172 ± 19 N/mm, and 178 ± 21 N/mm for ACLip®, ToggleLoc™, and TLS® devices, respectively. There was no significant difference between the implants except for post‐cycling elongation between TLZ and the other two implants (p < 0.05).Conclusion: The choice of femoral fixation device plays a decisive role in controlling the overall lengthening of an ACL reconstruction using a short hamstring graft. All implants validated the specifications in terms of ultimate load to failure, the TLS® system had, however, a low performance limit. ToggleLoc™ with adjustable loop should no longer be used on the femur side; instead the other types of fixation should be used to improve the overall elongation control.
- 19 November 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (7) , 2215-2226
Anterior cruciate ligament reconstruction with short hamstring grafts: the choice of femoral fixation device matters in controlling overall lengthening
Purpose: The purpose was to conduct an independent biomechanical study comparing the main types of femoral fixation adapted to short hamstring grafts in anterior cruciate ligament (ACL) reconstruction surgery and to validate their performance.Methods: The ACLip® Femoral, ToggleLoc™ Ziploop (TLZ), and Tape Locking Screw (TLS®) implants were tested in tension in the following three different configurations: implant alone, implant fixed on the femur without graft, and implant fixed on the femur with graft. Grafts alone were also tested. The femurs and the 4‐strand semi‐tendinosus grafts were derived from porcine and human models, respectively. Each set‐up was subjected to the same protocol of creep (50 N for 30 s), cycling (1000 cycles between 50 and 250 N, 1 Hz), and load to failure (50 mm/min).Results: A total of 93 tests were performed (30 ACLip®, 30 TLZ, 20 TLS®, and 13 ST4 alone). For the implants tested with femur and graft, the mean ± standard deviation (SD) overall elongation at 250 N after cycling was 5.2 ± 0.2 mm, 8.4 ± 2.1 mm, and 5.3 ± 0.8 mm, the mean ± SD ultimate load to failure was 736 ± 116 N, 830 ± 204 N, and 640 ± 242 N, and the mean ± SD stiffness at the 1000th cycle was 185 ± 15 N/mm, 172 ± 19 N/mm, and 178 ± 21 N/mm for ACLip®, ToggleLoc™, and TLS® devices, respectively. There was no significant difference between the implants except for post‐cycling elongation between TLZ and the other two implants (p < 0.05).Conclusion: The choice of femoral fixation device plays a decisive role in controlling the overall lengthening of an ACL reconstruction using a short hamstring graft. All implants validated the specifications in terms of ultimate load to failure, the TLS® system had, however, a low performance limit. ToggleLoc™ with adjustable loop should no longer be used on the femur side; instead the other types of fixation should be used to improve the overall elongation control.
- Open Access
- 27 August 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9, 732609
Corrigendum: Strain Assessment of Deep Fascia of the Thigh During Leg Movement: An in situ Study
Corrigendum: Strain Assessment of Deep Fascia of the Thigh During Leg Movement: An in situ Study
- 27 August 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9, 732609
Open AccessCorrigendum: Strain Assessment of Deep Fascia of the Thigh During Leg Movement: An in situ Study
Corrigendum: Strain Assessment of Deep Fascia of the Thigh During Leg Movement: An in situ Study
- Open Access
- 10 July 2020
- Published by EDP Sciences in SICOT-J
- Vol. 6, 27
Ilio-psoas impingement with a dual-mobility liner: an original case report and review of literature
Ilio-psoas impingement after total hip arthroplasty often occurs with the metallic rim of the acetabular cup. The main causes are poor cup anteversion or anterior wall defect. We firstly report here the case of a patient complaining of iliopsoas impingement due to contact with the liner of a dual-mobility device. Ultrasonography and Computed Tomographic scan clearly showed the direct mechanical contact of the dual-mobility liner with the iliopsoas tendon.
- 10 July 2020
- Published by EDP Sciences in SICOT-J
- Vol. 6, 27
Open AccessIlio-psoas impingement with a dual-mobility liner: an original case report and review of literature
Ilio-psoas impingement after total hip arthroplasty often occurs with the metallic rim of the acetabular cup. The main causes are poor cup anteversion or anterior wall defect. We firstly report here the case of a patient complaining of iliopsoas impingement due to contact with the liner of a dual-mobility device. Ultrasonography and Computed Tomographic scan clearly showed the direct mechanical contact of the dual-mobility liner with the iliopsoas tendon.
- Open Access
- 31 July 2019
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 13 (3) , 321-328
Distal biceps tendon repair via new knotless endobutton fixation: A biomechanical study
Background: Distal biceps tendon repair using endobutton fixation has shown the best biomechanical results in terms of pullout strength. Here, we compared Sethi’s enhanced tension adjustable endobutton technique known as the “tension slide technique” to a new knotless endobutton fixation technique without a post-fixation screw. Our new approach is as effective as the tension slide technique in terms of pullout strength and gapping after early mobilization. Methods: A biomechanical cadaveric study with 16 paired arms was performed. With the radius held in place, the distal biceps tendon was loaded at 100 N for 500 cycles and the load was then increased until failure. Gapping after loading cycles and maximum load to failure were recorded and compared. Results: Median bone-tendon gapping was 5.77 mm (interquartile range (IQR) 4.84–9.11) for tension slide technique and 4.72 mm (IQR 1.77–6.16) for the knotless fixation (p = 0.047). Median load to failure was 257.87 N (IQR 222.07–325.35) in the tension slide technique group and 407.78 N (IQR 358.54–485.20) in the knotless group (p = 0.047). Discussion: The knotless endobutton provides better pullout strength and elongation results compared to the tension slide technique without the use of an interference screw, allowing early mobilization in order to faster return to daily living activities. Level of evidence: Basic science study.
- 31 July 2019
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 13 (3) , 321-328
Open AccessDistal biceps tendon repair via new knotless endobutton fixation: A biomechanical study
Background: Distal biceps tendon repair using endobutton fixation has shown the best biomechanical results in terms of pullout strength. Here, we compared Sethi’s enhanced tension adjustable endobutton technique known as the “tension slide technique” to a new knotless endobutton fixation technique without a post-fixation screw. Our new approach is as effective as the tension slide technique in terms of pullout strength and gapping after early mobilization. Methods: A biomechanical cadaveric study with 16 paired arms was performed. With the radius held in place, the distal biceps tendon was loaded at 100 N for 500 cycles and the load was then increased until failure. Gapping after loading cycles and maximum load to failure were recorded and compared. Results: Median bone-tendon gapping was 5.77 mm (interquartile range (IQR) 4.84–9.11) for tension slide technique and 4.72 mm (IQR 1.77–6.16) for the knotless fixation (p = 0.047). Median load to failure was 257.87 N (IQR 222.07–325.35) in the tension slide technique group and 407.78 N (IQR 358.54–485.20) in the knotless group (p = 0.047). Discussion: The knotless endobutton provides better pullout strength and elongation results compared to the tension slide technique without the use of an interference screw, allowing early mobilization in order to faster return to daily living activities. Level of evidence: Basic science study.
- Open Access
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S172-S174
Assessment of the thigh skin and fascia strains during knee flexion-extension: an ex-vivo study
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S172-S174
Open AccessAssessment of the thigh skin and fascia strains during knee flexion-extension: an ex-vivo study
- 1 October 2018
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 22 (4) , 851-852
Fascia lata numerical model with discrete element method: relationship between micro and macroscale for tensile tests until rupture
- 1 October 2018
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 22 (4) , 851-852
Fascia lata numerical model with discrete element method: relationship between micro and macroscale for tensile tests until rupture
- Open Access
- 27 October 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (sup1) , S147-S148
Modelling of fascia lata rupture during tensile tests via the discrete element method
- 27 October 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (sup1) , S147-S148
Open AccessModelling of fascia lata rupture during tensile tests via the discrete element method
- Open Access
- 18 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0170377
Evaluation of 6 and 10 Year-Old Child Human Body Models in Emergency Events
Emergency events can influence a child’s kinematics prior to a car-crash, and thus its interaction with the restraint system. Numerical Human Body Models (HBMs) can help understand the behaviour of children in emergency events. The kinematic responses of two child HBMs–MADYMO 6 and 10 year-old models–were evaluated and compared with child volunteers’ data during emergency events–braking and steering–with a focus on the forehead and sternum displacements. The response of the 6 year-old HBM was similar to the response of the 10 year-old HBM, however both models had a different response compared with the volunteers. The forward and lateral displacements were within the range of volunteer data up to approximately 0.3 s; but then, the HBMs head and sternum moved significantly downwards, while the volunteers experienced smaller displacement and tended to come back to their initial posture. Therefore, these HBMs, originally intended for crash simulations, are not too stiff and could be able to reproduce properly emergency events thanks, for instance, to postural control.
- 18 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0170377
Open AccessEvaluation of 6 and 10 Year-Old Child Human Body Models in Emergency Events
Emergency events can influence a child’s kinematics prior to a car-crash, and thus its interaction with the restraint system. Numerical Human Body Models (HBMs) can help understand the behaviour of children in emergency events. The kinematic responses of two child HBMs–MADYMO 6 and 10 year-old models–were evaluated and compared with child volunteers’ data during emergency events–braking and steering–with a focus on the forehead and sternum displacements. The response of the 6 year-old HBM was similar to the response of the 10 year-old HBM, however both models had a different response compared with the volunteers. The forward and lateral displacements were within the range of volunteer data up to approximately 0.3 s; but then, the HBMs head and sternum moved significantly downwards, while the volunteers experienced smaller displacement and tended to come back to their initial posture. Therefore, these HBMs, originally intended for crash simulations, are not too stiff and could be able to reproduce properly emergency events thanks, for instance, to postural control.
- 1 December 2016
- Published by Elsevier in Revue de Chirurgie Orthopédique et Traumatologique
- Vol. 102 (8) , S275-S276
Comparaison biomécanique du comportement en fatigue de greffes quatre brins faufilées et non faufilées pour la reconstruction du ligament croisé antérieur
- 1 December 2016
- Published by Elsevier in Revue de Chirurgie Orthopédique et Traumatologique
- Vol. 102 (8) , S275-S276
Comparaison biomécanique du comportement en fatigue de greffes quatre brins faufilées et non faufilées pour la reconstruction du ligament croisé antérieur