Zhujun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhujun Zhang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Boquan Jin
Department of Immunology, The Fourth Military Medical University, Shaanxi, China
8 shared publications- Kun Yang
Department of Immunology, Air Force Medical University, No. 169, Changle West Road, Xi’an 710032, China
8 shared publications Liang Tao
Department of Immunology, The Fourth Military Medical University
8 shared publicationsXiaohua Li
School of Chemistry and Environmental Engineering, Shanxi Datong University, Datong, Shanxi, China
8 shared publicationsYuanjie Sun
Department of Immunology, The Fourth Military Medical University
7 shared publicationsChaojun Song
Department of Immunology, The Fourth Military Medical University, China.
4 shared publications
Latest Publications
- Open Access
- 7 September 2020
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 8, 802
Development of an Approach of High Sensitive Chemiluminescent Assay for Cystatin C Using a Nanoparticle Carrier
Cystatin C is an important cysteine protease inhibitor in the human body and is proposed as a new indicator of glomerular filtration rate for the detection of kidney damage. In this article, we report an ultra-sensitive, simple, and rapid chemiluminescence immunoassay method for cystatin C detection using functionalized mesoporous silica nanoparticles. After a three step hydrolysis, the amino-functionalized MSN encapsulating dye resulted in a hydrophobic environment for fixing the dye and amino groups for biological modification. The NaIO4 immobilization method maintained the activity of the antibody notably well. The sandwich immunoassay using two monoclonal antibodies was chosen for its selectivity. The analysis demonstrated that the detection upper was 0.0029 ng/mL and linear relationship within the range of 0.0035–0.5 ng/mL (R2 = 0.9936). The relative standard deviation (RSD) for 11 parallel measurements of 0.25 ng/mL CysC was 4.7%. The automated chemiluminescence analyzer could detect 96 wells continuously. The results demonstrated that this method is ultra-sensitive, simple, and rapid for detecting cystatin C.
- 7 September 2020
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 8, 802
Open AccessDevelopment of an Approach of High Sensitive Chemiluminescent Assay for Cystatin C Using a Nanoparticle Carrier
Cystatin C is an important cysteine protease inhibitor in the human body and is proposed as a new indicator of glomerular filtration rate for the detection of kidney damage. In this article, we report an ultra-sensitive, simple, and rapid chemiluminescence immunoassay method for cystatin C detection using functionalized mesoporous silica nanoparticles. After a three step hydrolysis, the amino-functionalized MSN encapsulating dye resulted in a hydrophobic environment for fixing the dye and amino groups for biological modification. The NaIO4 immobilization method maintained the activity of the antibody notably well. The sandwich immunoassay using two monoclonal antibodies was chosen for its selectivity. The analysis demonstrated that the detection upper was 0.0029 ng/mL and linear relationship within the range of 0.0035–0.5 ng/mL (R2 = 0.9936). The relative standard deviation (RSD) for 11 parallel measurements of 0.25 ng/mL CysC was 4.7%. The automated chemiluminescence analyzer could detect 96 wells continuously. The results demonstrated that this method is ultra-sensitive, simple, and rapid for detecting cystatin C.
- 10 November 2016
- Published by Wiley in Luminescence
- Vol. 32 (5) , 730-734
A rapid and high‐throughput method for the determination of serum uric acid based on microarray technology and nanomaterial
Serum uric acid (SUA) is a new therapeutic target for non‐alcoholic fatty liver disease (NAFLD). In this study, we introduced a chemiluminescence (CL) method combined with microarray technology and a simple fabrication procedure to obtain a highly sensitive SUA probe based on a mesoporous metal oxide nanomaterial. The high‐throughput method was based on the generation of H2O2 from SUA by immobilized uricase and its measurement by a CL reaction catalyzed by mesoporous metal oxide nanomaterials. The CL probe was designed for SUA The linear range of the uric acid concentration was 0.6–9 μM and the detection limit was 0.1 μM. In comparison with the other SUA detection techniques, this method has the advantages of a low detection limit, high sensitivity and simplicity. A new sensitive high‐throughput approach was obtained for the determination of SUA.
- 10 November 2016
- Published by Wiley in Luminescence
- Vol. 32 (5) , 730-734
A rapid and high‐throughput method for the determination of serum uric acid based on microarray technology and nanomaterial
Serum uric acid (SUA) is a new therapeutic target for non‐alcoholic fatty liver disease (NAFLD). In this study, we introduced a chemiluminescence (CL) method combined with microarray technology and a simple fabrication procedure to obtain a highly sensitive SUA probe based on a mesoporous metal oxide nanomaterial. The high‐throughput method was based on the generation of H2O2 from SUA by immobilized uricase and its measurement by a CL reaction catalyzed by mesoporous metal oxide nanomaterials. The CL probe was designed for SUA The linear range of the uric acid concentration was 0.6–9 μM and the detection limit was 0.1 μM. In comparison with the other SUA detection techniques, this method has the advantages of a low detection limit, high sensitivity and simplicity. A new sensitive high‐throughput approach was obtained for the determination of SUA.
- 31 May 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (16) , 4933-4940
Anti-CD155 and anti-CD112 monoclonal antibodies conjugated to a fluorescent mesoporous silica nanosensor encapsulating rhodamine 6G and fluorescein for sensitive detection of liver cancer cells
A novel method for sensitive detection of liver cancer cells using anti-CD155 and anti-CD112 monoclonal antibodies conjugated to ultrabright fluorescent mesoporous silica nanoparticles (FMSNs) encapsulating Rhodamine 6G and fluorescein was developed. The diameter of the obtained nanoparticles was 90 nm, and the quantum yield was 69%. Because the emission of fluorescein has a high degree of overlap with the excitation of Rhodamine 6G, and these two dyes were sufficiently close to each other on the nanoparticles, fluorescence resonance energy transfer can occur between these two dyes. This transfer not only maintains the original feature of the nanochannels and the skeletal network of the silica weakening the inner filtering of the dye, but also makes the excitation peak of the nanoparticles wider and increases the useful load amount of the dye. Because the wider Stokes shifts weaken the interference of excitation, the detection sensitivity is enhanced at the same time. The NaIO4 oxidation method does not use a cross-linker but rather uses covalent immobilization of the monoclonal antibodies on the FMSNs. This method can maintain the activity of the monoclonal antibodies more easily than the glutaraldehyde method. These advantages ensure that the nanosensor has high sensitivity and specificity for detecting liver cancer SMMC-7721 and HHCC cells. The in vivo imaging experiment also ensured that the biosensor can target tumor tissue in mice.
- 31 May 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (16) , 4933-4940
Anti-CD155 and anti-CD112 monoclonal antibodies conjugated to a fluorescent mesoporous silica nanosensor encapsulating rhodamine 6G and fluorescein for sensitive detection of liver cancer cells
A novel method for sensitive detection of liver cancer cells using anti-CD155 and anti-CD112 monoclonal antibodies conjugated to ultrabright fluorescent mesoporous silica nanoparticles (FMSNs) encapsulating Rhodamine 6G and fluorescein was developed. The diameter of the obtained nanoparticles was 90 nm, and the quantum yield was 69%. Because the emission of fluorescein has a high degree of overlap with the excitation of Rhodamine 6G, and these two dyes were sufficiently close to each other on the nanoparticles, fluorescence resonance energy transfer can occur between these two dyes. This transfer not only maintains the original feature of the nanochannels and the skeletal network of the silica weakening the inner filtering of the dye, but also makes the excitation peak of the nanoparticles wider and increases the useful load amount of the dye. Because the wider Stokes shifts weaken the interference of excitation, the detection sensitivity is enhanced at the same time. The NaIO4 oxidation method does not use a cross-linker but rather uses covalent immobilization of the monoclonal antibodies on the FMSNs. This method can maintain the activity of the monoclonal antibodies more easily than the glutaraldehyde method. These advantages ensure that the nanosensor has high sensitivity and specificity for detecting liver cancer SMMC-7721 and HHCC cells. The in vivo imaging experiment also ensured that the biosensor can target tumor tissue in mice.
- 11 May 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (7) , 2163-2168
Sensitive chemiluminescence immunoassay for staphylococcal enterotoxin C1 based on the use of dye-encapsulated mesoporous silica nanoparticles
- 11 May 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (7) , 2163-2168
Sensitive chemiluminescence immunoassay for staphylococcal enterotoxin C1 based on the use of dye-encapsulated mesoporous silica nanoparticles
- 8 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (14) , 2923-2928
The development of a novel chemiluminescent glucose sensor using hydrophilic Co3O4@SiO2 mesoporous nanoparticles
The development of a novel chemiluminescent glucose sensor using hydrophilic Co3O4@SiO2 mesoporous nanoparticles.
- 8 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (14) , 2923-2928
The development of a novel chemiluminescent glucose sensor using hydrophilic Co3O4@SiO2 mesoporous nanoparticles
The development of a novel chemiluminescent glucose sensor using hydrophilic Co3O4@SiO2 mesoporous nanoparticles.
- 1 February 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 120, 67-71
Development a novel approach of chemiluminescent probe array
- 1 February 2014
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 120, 67-71
Development a novel approach of chemiluminescent probe array
- 2 July 2013
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 171 (1) , 63-71
A Chemiluminescence Microarray Based on Catalysis by CeO2 Nanoparticles and Its Application to Determine the Rate of Removal of Hydrogen Peroxide by Human Erythrocytes
In this work, cerium oxide nanoparticles are capable of strongly enhancing the chemiluminescence (CL) of the luminol–hydrogen peroxide (H2O2) system. Based on this, a microarray CL method for the determination of the removal rate constant of H2O2 by human erythrocytes has been developed. It is providing direct evidence for a H2O2-removing enzyme in human erythrocytes that acts as the predominant catalyst. A reaction mechanism is discussed. The proposed microarray CL method is sensitive, selective, simple and time-saving, and has good reproducibility and high throughput. Relative CL intensity is linearly related to the concentration of H2O2 in the range from 0.01 to 50 μM. The limit of detection is as low as 6.5 × 10−11 M (3σ), and the relative standard deviation is 2. 1 % at 1 μM levels of H2O2 (for n = 11).
- 2 July 2013
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 171 (1) , 63-71
A Chemiluminescence Microarray Based on Catalysis by CeO2 Nanoparticles and Its Application to Determine the Rate of Removal of Hydrogen Peroxide by Human Erythrocytes
In this work, cerium oxide nanoparticles are capable of strongly enhancing the chemiluminescence (CL) of the luminol–hydrogen peroxide (H2O2) system. Based on this, a microarray CL method for the determination of the removal rate constant of H2O2 by human erythrocytes has been developed. It is providing direct evidence for a H2O2-removing enzyme in human erythrocytes that acts as the predominant catalyst. A reaction mechanism is discussed. The proposed microarray CL method is sensitive, selective, simple and time-saving, and has good reproducibility and high throughput. Relative CL intensity is linearly related to the concentration of H2O2 in the range from 0.01 to 50 μM. The limit of detection is as low as 6.5 × 10−11 M (3σ), and the relative standard deviation is 2. 1 % at 1 μM levels of H2O2 (for n = 11).
- 12 February 2013
- Published by Wiley in Luminescence
- Vol. 28 (4) , 474-481
Nepem‐211 ion exchange conductive membrane immobilized tris(2,2´‐bipyridyl) ruthenium(II) electrogenerated chemiluminescence flow sensor for high‐performance liquid chromatography and its application
We developed a sensitive and robust electrogenerated chemiluminescence (ECL) flow sensor based on Ru(bpy)32+ immobilized with a Nepem‐211 perfluorinated ion exchange conductance membrane, which has robustness and stability under a wide range of chemical and physical conditions, good electrical conductivity, isotropy and a high exchange capacity for immobilization of Ru(bpy)32+. The flow sensor has been used as a post‐column detector in high‐performance liquid chromatography for determination of erythromycin and clarithromycin in honey and pork, and tricyclic antidepressant drugs in human urine. Under optimal conditions, the linear ranges were 0.03–26 ng/μL and 0.01–1 ng/μL for macrolides and tricyclic antidepressant drugs, respectively. The detection limits were 0.02, 0.01, 0.01, 0.06 and 0.003 ng/μL for erythromycin, clarithromycin, doxepin, amitriptyline and clomipramine, respectively. There is no post‐column reagent addition. In addition to the conservation expensive reagents, the experimental setup was simplified. The flow sensor was used for 2 years with high sensitivity and stability. Copyright © 2013 John Wiley & Sons, Ltd.
- 12 February 2013
- Published by Wiley in Luminescence
- Vol. 28 (4) , 474-481
Nepem‐211 ion exchange conductive membrane immobilized tris(2,2´‐bipyridyl) ruthenium(II) electrogenerated chemiluminescence flow sensor for high‐performance liquid chromatography and its application
We developed a sensitive and robust electrogenerated chemiluminescence (ECL) flow sensor based on Ru(bpy)32+ immobilized with a Nepem‐211 perfluorinated ion exchange conductance membrane, which has robustness and stability under a wide range of chemical and physical conditions, good electrical conductivity, isotropy and a high exchange capacity for immobilization of Ru(bpy)32+. The flow sensor has been used as a post‐column detector in high‐performance liquid chromatography for determination of erythromycin and clarithromycin in honey and pork, and tricyclic antidepressant drugs in human urine. Under optimal conditions, the linear ranges were 0.03–26 ng/μL and 0.01–1 ng/μL for macrolides and tricyclic antidepressant drugs, respectively. The detection limits were 0.02, 0.01, 0.01, 0.06 and 0.003 ng/μL for erythromycin, clarithromycin, doxepin, amitriptyline and clomipramine, respectively. There is no post‐column reagent addition. In addition to the conservation expensive reagents, the experimental setup was simplified. The flow sensor was used for 2 years with high sensitivity and stability. Copyright © 2013 John Wiley & Sons, Ltd.
- 16 January 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (5) , 1596-1600
A novel microarray chemiluminescence method based on chromium oxide nanoparticles catalysis for indirect determination of the explosive triacetone triperoxide at the scene
Chromium oxide (Cr2O3) nanoparticles were found to greatly enhance the chemiluminescence (CL) of the luminol–hydrogen peroxide (H2O2) system. A novel microarray CL method was originally developed for the detection of triacetone triperoxide (TATP). The novel CL method was based on the outstanding catalytic effect of a Cr2O3 nanoparticle array on the CL reaction between lower concentrations of luminol and H2O2, which come from hydrolysis of TATP vapor. The calibration curve of H2O2 was linear over a range of 1.0 × 10−8 to 3.0 × 10−5 M with a detection limit of 1.6 × 10−9 M (R2 = 0.9992, n = 12). The CL method has the advantages of being sensitive, selective, simple, time-saving, high-throughput, and shows good reproducibility. Therefore, these merits would make it easily popular.
- 16 January 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (5) , 1596-1600
A novel microarray chemiluminescence method based on chromium oxide nanoparticles catalysis for indirect determination of the explosive triacetone triperoxide at the scene
Chromium oxide (Cr2O3) nanoparticles were found to greatly enhance the chemiluminescence (CL) of the luminol–hydrogen peroxide (H2O2) system. A novel microarray CL method was originally developed for the detection of triacetone triperoxide (TATP). The novel CL method was based on the outstanding catalytic effect of a Cr2O3 nanoparticle array on the CL reaction between lower concentrations of luminol and H2O2, which come from hydrolysis of TATP vapor. The calibration curve of H2O2 was linear over a range of 1.0 × 10−8 to 3.0 × 10−5 M with a detection limit of 1.6 × 10−9 M (R2 = 0.9992, n = 12). The CL method has the advantages of being sensitive, selective, simple, time-saving, high-throughput, and shows good reproducibility. Therefore, these merits would make it easily popular.
- 7 December 2012
- Published by Elsevier in Analytica Chimica Acta
- Vol. 761, 194-200
A fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle as a label for the ultrasensitive detection of cancer cells
- 7 December 2012
- Published by Elsevier in Analytica Chimica Acta
- Vol. 761, 194-200
A fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle as a label for the ultrasensitive detection of cancer cells