AVAndras E. Vladar

Andras E. Vladar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andras E. Vladar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Limits of Resolutions in the Scanning Electron Microscope

    by András E Vladár, Kerim T Arat

    All forms of microscopy are being pushed by nanometer-scale science and technology to attain better and better resolution. The so-called resolution of the SEM, one of its key specified performance parameters, is an ill-defined entity, and various instrument manufacturers use different methods of calculating it. It may mean imaging or spatial resolution that is generally understood as the degree of small-size sample details, e.g., a gap made visible or an image sharpness metric, related to the slew rate of signal transitions at the edges of a suitable sample [ 1–4]. Resolution may also mean measurement resolution, which is the ability to quantitatively distinguish features or attributes of samples or measurands [ 5]. Measurement resolution can be significantly better than the spatial resolution. There are physics and engineering limits of resolutions and the ones posed by the performance of a SEM, its environment and the knowledge and skills of the user. These together determine what a SEM is capable of. To some extent these limitations can be optimized to achieve better spatial and measurement resolutions.


  • Electron Irradiation Cleaning of the SEM and its Samples

    by Andras Vladar, David Hoyle, Hosoya Kotaro

    Electron Irradiation Cleaning of the SEM and its Samples - Volume 27 Issue S1


  • Three-Dimensional (3D) Nanometrology Based on Scanning Electron Microscope (SEM) Stereophotogrammetry

    by Vipin N. Tondare, John S. Villarrubia, András E. Vladár

    Three-dimensional (3D) reconstruction of a sample surface from scanning electron microscope (SEM) images taken at two perspectives has been known for decades. Nowadays, there exist several commercially available stereophotogrammetry software packages. For testing these software packages, in this study we used Monte Carlo simulated SEM images of virtual samples. A virtual sample is a model in a computer, and its true dimensions are known exactly, which is impossible for real SEM samples due to measurement uncertainty. The simulated SEM images can be used for algorithm testing, development, and validation. We tested two stereophotogrammetry software packages and compared their reconstructed 3D models with the known geometry of the virtual samples used to create the simulated SEM images. Both packages performed relatively well with simulated SEM images of a sample with a rough surface. However, in a sample containing nearly uniform and therefore low-contrast zones, the height reconstruction error was ≈46%. The present stereophotogrammetry software packages need further improvement before they can be used reliably with SEM images with uniform zones.


  • Real-Time Scanning Charged-Particle Microscope Image Composition with Correction of Drift

    by Petr Cizmar, András E. Vladár, Michael T. Postek

    In this article, a new scanning electron microscopy (SEM) image composition technique is described, which can significantly reduce drift related image corruptions. Drift distortion commonly causes blur and distortions in the SEM images. Such corruption ordinarily appears when conventional image-acquisition methods, i.e., “slow scan” and “fast scan,” are applied. The damage is often very significant; it may render images unusable for metrology applications, especially where subnanometer accuracy is required. The described correction technique works with a large number of quickly taken frames, which are properly aligned and then composed into a single image. Such image contains much less noise than the individual frames, while the blur and deformation is minimized. This technique also provides useful information about changes of the sample position in time, which may be applied to investigate the drift properties of the instrument without a need of additional equipment.


  • On the Sub-Nanometer Resolution of Scanning Electron and Helium Ion Microscopes

    by András E Vladár, Michael T. Postek, Bin Ming

    All forms of microscopy are being pushed to the limit by nanotechnology. This is especially true for high-resolution scanning electron and helium ion microscopes, which are proving to be extremely useful for nanometer-scale imaging, characterization, and dimensional measurements. Excellent resolution is essential for imaging nanomaterials. Hence, there is a relentless quest to achieve better and better resolution with various electron and ion microscopes and to monitor and maintain these instruments to achieve the best possible performance levels.The ability to resolve fine details with a microscope has greatly improved over the past 20 years. The resolution achievable with the newest scanning electron microscopes (SEMs) can now be at or below 0.4 nm and for the scanning helium ion microscope (HeIM), 0.24 nm has been reported. To put this into perspective, the {111} crystal plane in silicon (Si) has 0.32 nm lattice spacing, so one cubic nanometer in the Si crystal contains only a few atoms. Therefore, an instrument must be performing at the highest level possible to resolve routinely the finest structures. Clearly, the instrument operator must also be functioning at a high level as well to achieve the best resolution and to prove that the instrument is capable of doing the work.


  • Open Access

    Nanotip electron gun for the scanning electron microscope

    by András E. Vladár, Zsolt Radi, Michael T. Postek, David C. Joy

    Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal‐to‐noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long‐lasting and stable for practical use. In this study, an older field‐emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a “sharp” tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two‐fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for highresolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters.


  • New method for the measurement of SEM stage vibrations

    by Bradley N. Damazo, Eranga C. Jayewardene, Andras E. Vladar, William J. Keery, Michael T. Postek

    The National Institute of Standards and Technology (NIST) has implemented a high bandwidth laser interferometer measurement system in a specialized metrology microscope. The purpose of the system is the certification of SEM magnification calibration samples by moving the sample under a finely focused stationary electron beam in the metrology electron microscope. Using a laser interferometer with displacement measurements traceable to basic wavelength standards, the motion is measured while recording the secondary or backscattered electron output signal. The recent upgrade to the laser measurement system enables a measurement bandwidth of 300 kHz to be achieved in the sampling of the X-Y position of a test sample, along with measuring the intensity of the secondary electron beam output signal. This high bandwidth stage position measurement capability becomes a tool to measure the effects of environmental vibrations on SEM measurements. This paper outlines this ongoing research and presents the current results along with details of the measurement possibilities based on this new technique.


  • Modification of a commercial SEM with a computer controlled cathode stabilized power supply

    by Michael T. Postek, William J. Keery, Andras E. Vladar