JGJames F. Glockner

James F. Glockner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James F. Glockner has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Renal Fibrosis Using Magnetization Transfer Imaging at 1.5T and 3T in a Porcine Model of Renal Artery Stenosis

    by Deep B. Gandhi, Mina Al Saeedi, James D. Krier, Kai Jiang, James F. Glockner, Lilach O. Lerman

    Renal fibrosis is an important marker in the progression of chronic kidney disease, and renal biopsy is the current reference standard for detecting its presence. Currently, non-invasive methods have only been partially successful in detecting renal fibrosis. Magnetization transfer imaging (MTI) allows estimates of renal fibrosis but may vary with scanning conditions. We hypothesized that MTI-derived renal fibrosis would be reproducible at 1.5T and 3T MRI and over time in fibrotic kidneys. Fifteen pigs with unilateral renal artery stenosis (RAS, n = 9) or age-matched sham controls (n = 6) underwent MTI-MRI at both 1.5T and 3T 6 weeks post-surgery and again 4 weeks later. Magnetization transfer ratio (MTR) measurements of fibrosis in both kidneys were compared between 1.5T and 3T, and the reproducibility of MTI at the two timepoints was evaluated at 1.5T and 3T. MTR at 3T with 600 Hz offset frequency successfully distinguished between normal, stenotic, and contralateral kidneys. There was excellent reproducibility of MTI at 1.5T and 3T over the two timepoints and no significant differences between MTR measurements at 1.5T and 3T. Therefore, MTI is a highly reproducible technique which is sensitive to detect changes in fibrotic compared to normal kidneys in the RAS porcine model at 3T.

  • Magnetization Transfer Imaging Predicts Porcine Kidney Recovery After Revascularization of Renal Artery Stenosis

    by Mohsen Afarideh, Kai Jiang, Christopher M. Ferguson, John R. Woollard, James F. Glockner, Lilach O. Lerman

    Objectives: Magnetization transfer imaging is a novel noninvasive tool for the detection of kidney fibrosis, but its association with kidney function and hemodynamics is unclear. Renovascular disease (RVD) associated with metabolic derangements elicits renal fibrosis and is often unresponsive to percutaneous transluminal angioplasty (PTRA), but tools to predict therapeutic success are unavailable. We hypothesized that magnetization transfer imaging predicts kidney recovery after PTRA in swine with unilateral RVD. Materials and Methods: Stenotic kidney (STK) and contralateral kidney magnetization transfer ratios (MTRs; M t/M 0) were measured at 3.0-T magnetic resonance imaging, at offset frequencies of 600 and 1000 Hz, before and 1 month post-PTRA in 7 RVD pigs. Stenotic kidney MTR was correlated to renal perfusion, renal blood flow (RBF), and glomerular filtration rate (GFR), determined using multidetector computed tomography and with ex vivo renal fibrosis (trichrome staining). Untreated RVD (n = 6) and normal pigs (n = 7) served as controls. Results: Renovascular disease induced hypertension and renal dysfunction. Blood pressure and renal perfusion were unchanged post-PTRA, but GFR and RBF increased. Baseline cortical STK-MTR predicted post-PTRA renal perfusion and RBF, and MTR changes associated inversely with changes in perfusion and normalized GFR. Stenotic kidney MTR at 600 Hz showed closer association with renal parameters, but both frequencies predicted post-PTRA cortical fibrosis. Conclusions: Renal STK-MTR, particularly at 600 Hz offset, is sensitive to hemodynamic changes after PTRA in swine RVD and capable of noninvasively predicting post-PTRA kidney perfusion, RBF, and fibrosis. Therefore, STK-MTR may be a valuable tool to predict renal hemodynamic and functional recovery, as well as residual kidney fibrosis after revascularization in RVD.


  • Magnetic resonance imaging

    by James F. Glockner, Kazuhiro Kitajima, Akira Kawashima

    Magnetic resonance imaging (MRI) provides excellent anatomic detail and soft tissue contrast for the evaluation of patients with renal disease. MRI needs longer scan time than computed tomography (CT); however, no radiation is involved. Gadolinium-based contrast agents (GBCAs) are used to help provide additional image contrast during MRI. MRI is indicated for characterization of renal mass, staging of malignant renal neoplasms, and determination of vena cava involvement by the renal tumour. Magnetic resonance (MR) angiography is widely accepted as a non-invasive imaging work-up of renal artery stenosis. MR urography is an alternative to CT urography to assess the upper urinary tract but does not identify urinary calculi. Diffusion-weighted imaging is a functional MR technique being used to characterize parenchymal renal disease and renal tumours. Nephrogenic systemic fibrosis is a rare but debilitating and potentially life-threatening condition which has been linked to exposure of GBCAs in patients with severe renal insufficiency. The risk versus benefit must be assessed before proceeding.

  • Magnetic Resonance Imaging and Computed Tomography of Cardiac Masses and Pseudomasses in the Atrioventricular Groove

    by James F. Glockner

    The atrioventricular (AV) groove constitutes the anatomic space separating the atria and ventricles. The AV groove is often difficult to visualize at echocardiography, and suspected lesions can be further assessed with cardiac computed tomography or magnetic resonance imaging. AV groove lesions may originate from within the AV groove or extend into this space from adjacent structures. The differential diagnosis for AV groove lesions is often wide, but a precise diagnosis can sometimes be made. This pictorial essay illustrates the magnetic resonance imaging and computed tomography appearance of common and uncommon AV groove lesions, and attempts to provide a logical framework for differential diagnosis when confronted with a known or suspected lesion at cross-sectional imaging.


  • Open Access

    Magnetic Resonance Imaging of Perirenal Pathology

    by James F. Glockner, Christine U. Lee

    The perirenal space can be involved by a variety of neoplastic, inflammatory, infectious, and proliferative disorders. Magnetic resonance imaging is often an ideal technique for identification and staging of lesions arising within the perirenal space, with its superior soft tissue characterization as well as its ability to visualize extension into blood vessels and adjacent organs. This pictorial essay describes the magnetic resonance imaging appearance of a variety of pathologies which can arise from or involve the perirenal space, and provides a framework for categorization and differential diagnosis of these lesions.


  • MRI of common and uncommon pathologies involving the periportal space: a pictorial essay

    by Christine U. Lee, James F. Glockner

    Imaging detection and differential diagnoses of pathology involving the periportal space can be challenging. MRI is a useful technique for assessment of the periportal space since it readily distinguishes normal and abnormal vascular and biliary anatomy, and the excellent soft tissue discrimination allows for detection of subtle lesions. This pictorial essay describes the anatomy of the periportal space and illustrates the MRI appearance of a variety of pathologies that can affect this region.


  • Magnetic resonance imaging

    by Kazuhiro Kitajima, Akira Kawashima, James F. Glockner

    Magnetic resonance imaging (MRI) provides excellent anatomic detail and soft tissue contrast for the evaluation of patients with renal disease. MRI needs longer scan time than computed tomography (CT); however, no radiation is involved. Gadolinium-based contrast agents (GBCAs) are used to help provide additional image contrast during MRI. MRI is indicated for characterization of renal mass, staging of malignant renal neoplasms, and determination of vena cava involvement by the renal tumour. Magnetic resonance (MR) angiography is widely accepted as a non-invasive imaging work-up of renal artery stenosis. MR urography is an alternative to CT urography to assess the upper urinary tract but does not identify urinary calculi. Diffusion-weighted imaging is a functional MR technique being used to characterize parenchymal renal disease and renal tumours. Nephrogenic systemic fibrosis is a rare but debilitating and potentially life-threatening condition which has been linked to exposure of GBCAs in patients with severe renal insufficiency. The risk versus benefit must be assessed before proceeding.

  • Renal MR Angiography

    by James F. Glockner